Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYDRAZINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Theoretical performance of liquid ammonia, hydrazine and mixture of liquid ammonia and hydrazine as fuels with liquid oxygen biflouride as oxidant for rocket engines : I-mixture of liquid ammonia and hydrazine

Theoretical performance for mixture of 36.3 percent liquid ammonia and 63.7 percent hydrazine with liquid oxygen bifluoride as rocket propellant was calculated on assumption of equilibrium composition during expansion for a wide range of fuel-oxidant and expansios ratios. Parameters included were specific impulse, combustion-chamber temperature, nozzle exit temperature, composition mean molecular weight, characteristic velocity, coefficient of thrust and ratio of nozzle-exit area to throat area. For chamber pressure of 300 pounds per square inch absolute and expansion to 1 atmosphere, maximum specific impulse was 295.8 pound-seconds per pound. Five percent by weight of water in the hydrazine lowered specific impulse from about one to three units over a wide range of weight-percent fuel.

Huff, Vearl N↗

Cross‐Coupling between Hydrazine and Aryl Halides with Hydroxide Base at Low Loadings of Palladium by Rate‐Determining Deprotonation of Bound Hydrazine

Abstract Reported here is the Pd‐catalyzed C–N coupling of hydrazine with (hetero)aryl chlorides and bromides to form aryl hydrazines with catalyst loadings as low as 100 ppm of Pd and KOH as base. Mechanistic studies revealed two catalyst resting states: an arylpalladium(II) hydroxide and arylpalladium(II) chloride. These compounds are present in two interconnected catalytic cycles and react with hydrazine and base or hydrazine alone to give the product. The selectivity of the hydroxide complex with hydrazine to form aryl over diaryl hydrazine was lower than that of the chloride complex, as well as the catalytic reaction. In contrast, the selectivity of the chloride complex closely matched that of the catalytic reaction, indicating that the aryl hydrazine is derived from this complex. Kinetic studies showed that the coupling process occurs by rate‐limiting deprotonation of a hydrazine‐bound arylpalladium(II) chloride complex to give an arylpalladium(II) hydrazido complex.

Wang, Justin Y.↗

Cross‐Coupling between Hydrazine and Aryl Halides with Hydroxide Base at Low Loadings of Palladium by Rate‐Determining Deprotonation of Bound Hydrazine

Abstract Reported here is the Pd‐catalyzed C–N coupling of hydrazine with (hetero)aryl chlorides and bromides to form aryl hydrazines with catalyst loadings as low as 100 ppm of Pd and KOH as base. Mechanistic studies revealed two catalyst resting states: an arylpalladium(II) hydroxide and arylpalladium(II) chloride. These compounds are present in two interconnected catalytic cycles and react with hydrazine and base or hydrazine alone to give the product. The selectivity of the hydroxide complex with hydrazine to form aryl over diaryl hydrazine was lower than that of the chloride complex, as well as the catalytic reaction. In contrast, the selectivity of the chloride complex closely matched that of the catalytic reaction, indicating that the aryl hydrazine is derived from this complex. Kinetic studies showed that the coupling process occurs by rate‐limiting deprotonation of a hydrazine‐bound arylpalladium(II) chloride complex to give an arylpalladium(II) hydrazido complex.

Wang, Justin Y.↗

Developing a New Sampling And Analysis Method For Hydrazine And Monomethyl Hydrazine: Using a Derivatizing Agent With Solid Phase Microextraction

Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCI), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.

Allen, John↗

Developing A New Sampling and Analysis Method for Hydrazine and Monomethyl Hydrazine

Solid phase microextraction (SPME) will be used to develop a method for detecting monomethyl hydrazine (MMH) and hydrazine (Hz). A derivatizing agent, pentafluorobenzoyl chloride (PFBCl), is known to react readily with MMH and Hz. The SPME fiber can either be coated with PFBCl and introduced into a gaseous stream containing MMH, or PFBCl and MMH can react first in a syringe barrel and after a short equilibration period a SPME is used to sample the resulting solution. These methods were optimized and compared. Because Hz and MMH can degrade the SPME, letting the reaction occur first gave better results. Only MMH could be detected using either of these methods. Future research will concentrate on constructing calibration curves and determining the detection limit.

Allen, John R.↗

A Portable Electronic Nose For Hydrazine and Monomethyl Hydrazine Detection

The Space Program and military use large quantities Hydrazine (Hz) and monomethyl hydrazine (MMI-I) as rocket propellant. These substances are very toxic and are suspected human carcinogens. The American Conference of Governmental Industrial Hygienist set the threshold limit value to be 10 parts per billion (ppb). Current off-the-shelf portable instruments require 10 to 20 minutes of exposure to detect 10 ppb concentration. This shortcofriing is not acceptable for many operations. A new prototype instrument using a gas sensor array and pattern recognition software technology (i.e., an electronic nose) has demonstrated the ability to identify either Hz or MM}{ and quantify their concentrations at 10 parts per billion in 90 seconds. This paper describes the design of the portable electronic nose (e-nose) instrument, test equipment setup, test protocol, pattern recognition algorithm, concentration estimation method, and laboratory test results.

Young, Rebecca C.↗

Putting chromium on the map for N 2 reduction: production of hydrazine and ammonia. A study of cis -M(N 2 ) 2 (M = Cr, Mo, W) bis(diphosphine) complexes

The first complete structurally and spectroscopically characterized series of isostructural Group 6 N 2 complexes is reported in this paper. Protonolysis experiments on cis-[M(N 2 ) 2 (P Et N R P Et ) 2 ] (M = Cr, Mo, W; R = 2,6-difluorobenzyl) reveal that only Cr affords N 2 H 5 + and NH 4 + from the reduction of the N 2 ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three Methods of Detection of Hydrazines

Three proposed methods for measuring trace quantities of hydrazines involve ionization and detection of hydrazine derivatives. These methods are intended to overcome the limitations of prior hydrazine- detection methods. Hydrazine (Hz), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH) are hypergolic fuels and are highly reactive, toxic, and corrosive. A capability to measure concentrations of hydrazines is desirable for detecting leaks and ensuring safety in aerospace settings and in some industrial settings in which these compounds are used. One of the properties (high reactivity) that make it desirable to detect trace amounts of hydrazines also makes it difficult to detect hydrazines and measure their concentrations accurately using prior methods: significant amounts are lost to thermal and catalytic decomposition prior to detection. Further complications arise from the sticky nature of hydrazines: Sample hydrazine molecules tend to become irreversibly adsorbed onto solid surfaces with which they come into contact during transport to detectors, giving rise to drift in detector responses. In each proposed method, the reactive, sticky nature of hydrazines would be turned to advantage by providing a suitably doped substrate surface with which the hydrazines would react. The resulting hydrazine derivatives would be sufficiently less sticky and sufficiently more stable so that fewer molecules would be lost to decomposition or adsorption during transport. Consequently, it would be possible to measure concentration with more sensitivity and less error than in prior techniques. The first proposed method calls for the use of a recently developed technique known as desorption electrospray ionization (DESI), in which a pneumatically assisted micro -electrospray at ambient pressure is directed at a surface of interest. In this case, the surface of interest would be that of a substrate described above.

Griffin, Timothy↗