Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYDROGEN STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Predicting demand for hydrogen station fueling

Full function hydrogen stations are a reality; fuel cell electric vehicle drivers can pull up to commercial fueling stations and receive 3–5 kg in less than 5 min, for an approximately 300-mile range. The demand for hydrogen is increasing, driven by an increase in the fueling of public and private fuel cell vehicles. This study describes the development and value of a model that simulates stochastic future demand at a hydrogen filling station. The predictive hydrogen demand model described in this article is trained from mathematical models constructed from actual hydrogen fill count, amount, and frequency data. Future fill probabilities inform the hour-by-hour demand profile and the station state of either “available, ready to fill” or “available, filling”. For example, a prediction for a station generally dispensing 5,000 kg a week on a Friday afternoon at 4 p.m. is 16 fills, totaling 48.7 kg, with a 0.52 proportion of time spent in “available, filling” state yielding 31 min of filling time. This is a first-of-its kind, published study on predicting future hydrogen demand by the time of day (e.g., hour-by-hour intervals) and day of week. This study can be used for hydrogen station requirements and operation and maintenance strategies and to assess the impact of demand variations and scenarios. Finally, this article presents the current status of hydrogen demand, the model development methods, a set of sample results. Discussion and conclusions concentrate on the value and use of the proposed model.

08 HYDROGEN↗

Data Collection and Validation of Newport Beach Hydrogen Station Performance

The hydrogen fueling station located at 1600 Jamboree Road in Newport Beach, California was designed and built to refuel light duty fuel cell electric vehicles (FCEVs). The station features the on-site generation of hydrogen through a small scale natural gas steam methane reformer (SMR). All the hydrogen related equipment was added to an existing retail gasoline/diesel station. The station is an early demonstration of what the footprint and equipment arrangement of a retail on-site SMR facility might look like. Commercial customer FCEV leases have only just begun in the last two years or so. And, individual Original Equipment Manufacturer (OEM) vehicle lease fleets are relatively small. Only a few hundred FCEVs are on the road in California. As a result, hydrogen throughput is relatively low at the few early pre-commercial hydrogen stations that are currently open. Therefore the stations are underutilized. This project aims to collect additional station data to allow the operator to potentially adjust various operational parameters in order to improve the overall efficiency of the station and lower operation and maintenance costs and to help improve air quality and reduce greenhouse gas emissions. Due to unforeseen delays, technical challenges and personnel reassignments the project was delayed to the point that the award was allowed to expire.

08 HYDROGEN↗

Assuring pulsation-free flow in a directly pressurized fuel delivery at a retail hydrogen station

When a retail hydrogen station operates using booster compressors to directly fill cars, a need for an additional high-pressure buffer volume is present, in order to mitigate potential pressure pulsations in the system. Looking at the case of the Cal State LA Hydrogen Fueling Station, pulsations with a magnitude up to 6.7 MPa were observed with no buffer volume during 70 MPa fueling. Thus the focus was placed on determining the minimum buffer volume required to ensure pulsation free operation to the entire downstream system (booster compressors, piping and the vehicle hydrogen hardware). A mathematical model of volumes involved has been developed and compared to experimental measurements. The station configuration allows isolating one or more of the four high-pressure buffer tanks with which the station was upgraded to reduce pulsations. Each tank has a volume of 0.05 m 3 . A relatively simple model developed shows a strong correlation with the experiments in determining the maximum pulse and the minimum additional high-pressure buffer volume. Effectively, one buffer tank would have provided a proper operation of the station by keeping the pressure pulsation magnitude under 0.2 MPa.

08 HYDROGEN↗

DCFC + Hydrogen Station Design Optimization [Slides]

Both direct current fast charging (DCFC) and Hydrogen stations are working to create successful long-term business models; however, analyses for DCFC and hydrogen fueling infrastructure are almost always performed separately. This work provides a detailed exploration of the benefit of integrating DCFC and hydrogen stations to lower the total system cost from load balancing and equipment cost sharing. To achieve this we have adapted the REopt optimization framework to simultaneously optimize the design and operation of integrated DCFC and H2 fueling station. Results indicate that 1) combining hydrogen fueling and DCFC stations can significantly reduce lifetime costs compared to separated stations. 2) Co-location with additional site load reduces DCFC costs, however, integration of DCFC with hydrogen provides an even greater cost reduction. 3) Adding PV to combined stations further reduces the lifetime station cost. 4) Capital investments in station combination today can help reduce the cost of operating DCFC tomorrow and 5) product diversification acts as a hedge against variability and enables a more dynamic response to market changes.

08 HYDROGEN↗

Innovating High Throughput Hydrogen Stations: Cooperative Research and Development Final Report, CRADA Number CRD-18-00773

Hydrogen stations today serve the emerging market of light duty fuel cell vehicles, primarily in California with over 30 public retail locations. There has been a steady increase in the number of stations open and hydrogen dispensed, especially in the last two years. From 2015 to 2016, the annual amount of hydrogen dispensed increased from 27,400 kg to 109,200 kg, a nearly fourfold increase in just one year. One station dispensed nearly 12,000 kg in the second quarter of 2017. Despite the significant progress, gaps exist between current infrastructure capabilities and future requirements. For example, fuel cell vehicle applications such as buses, medium-duty, and heavy-duty trucks will gain market share and this must be considered as future customers at hydrogen stations. The expected number of light duty fuel cell vehicles in California alone are expected to grow from approximately 4,000 to over 13,000 by 2020, and 37,000 by 2023. To serve the multiple mobile fuel cell technologies and increased demand, hydrogen stations will have to increase output, decrease cost, and improve reliability. To address these challenges, the project team will demonstrate a hydrogen-focused integrated renewable energy production, storage, and transportation fuel distribution/retailing system. The proposed R&D tasks address key challenges related to light duty station/component reliability and development and validation of high flow rate system models for new applications like medium and heavy-duty truck fueling.

08 HYDROGEN↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗

Retail Hydrogen Station Reliability Status and Advances

One of the most vital emerging commercial markets for hydrogen is fuel cell-powered mobility including cars, trucks, and buses. These vehicles are refueled via a network of hydrogen fueling stations, with the highest number of U.S. stations being in California. The numbers of both fuel cell electric vehicles (FCEVs) and hydrogen stations have increased in the last two years, with anecdotal information from FCEV drivers indicating that station reliability is hurting the consumer acceptability of FCEV technologies. Therefore, this study benchmarks the current state of hydrogen station reliability in practice and presents on-going research that is investigating the failures that are contribute to hydrogen station reliability issues. This is accomplished with an analysis of operation, safety, and maintenance data from hydrogen stations and fuel cell electric vehicles to benchmark the maintenance and failure of hydrogen stations and their components. This analysis, of over 5,000 station maintenance events, presents the leading maintenance categories and failure rates, and is a prerequisite to the development of data-driven reliability improvement plans. We present a reliability growth analysis and on-going research into the root causes of failure for dispensers, a particularly failure-prone subsystem.

08 HYDROGEN↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Hydrogen Filling Station

Hydrogen is an environmentally attractive transportation fuel that has the potential to displace fossil fuels. The Freedom CAR and Freedom FUEL initiatives emphasize the importance of hydrogen as a future transportation fuel. Presently, Las Vegas has one hydrogen fueling station powered by natural gas. However, the use of traditional sources of energy to produce hydrogen does not maximize the benefit. The hydrogen fueling station developed under this grant used electrolysis units and solar energy to produce hydrogen fuel. Water and electricity are furnished to the unit and the output is hydrogen and oxygen. Three vehicles were converted to utilize the hydrogen produced at the station. The vehicles were all equipped with different types of technologies. The vehicles were used in the day-to-day operation of the Las Vegas Valley Water District and monitoring was performed on efficiency, reliability and maintenance requirements. The research and demonstration utilized for the reconfiguration of these vehicles could lead to new technologies in vehicle development that could make hydrogen-fueled vehicles more cost effective, economical, efficient and more widely used. In order to advance the development of a hydrogen future in Southern Nevada, project partners recognized a need to bring various entities involved in hydrogen development and deployment together as a means of sharing knowledge and eliminating duplication of efforts. A road-mapping session was held in Las Vegas in June 2006. The Nevada State Energy Office, representatives from DOE, DOE contractors and LANL, NETL, NREL were present. Leadership from the National hydrogen Association Board of Directors also attended. As a result of this session, a roadmap for hydrogen development was created. This roadmap has the ability to become a tool for use by other road-mapping efforts in the hydrogen community. It could also become a standard template for other states or even countries to approach planning for a hydrogen future. Project partners also conducted a workshop on hydrogen safety and permitting. This provided an opportunity for the various permitting agencies and end users to gather to share experiences and knowledge. As a result of this workshop, the permitting process for the hydrogen filling station on the Las Vegas Valley Water District’s land was done more efficiently and those who would be responsible for the operation were better educated on the safety and reliability of hydrogen production and storage. The lessons learned in permitting the filling station and conducting this workshop provided a basis for future hydrogen projects in the region. Continuing efforts to increase the working pressure of electrolysis and efficiency have been pursued. Research was also performed on improving the cost, efficiency and durability of Proton Exchange Membrane (PEM) hydrogen technology. Research elements focused upon PEM membranes, electrodes/catalysts, membrane-electrode assemblies, seals, bipolar plates, utilization of renewable power, reliability issues, scale, and advanced conversion topics. Additionally, direct solar-to-hydrogen conversion research to demonstrate stable and efficient photoelectrochemistry (PEC) hydrogen production systems based on a number of optional concepts was performed. Candidate PEC concepts included technical obstacles such as inefficient photocatalysis, inadequate photocurrent due to non-optimal material band gap energies, rapid electron-hole recombination, reduced hole mobility and diminished operational lifetimes of surface materials exposed to electrolytes. Project Objective 1: Design, build, operate hydrogen filling station Project Objective 2: Perform research and development for utilizing solar technologies on the hydrogen filling station and convert two utility vehicles for use by the station operators Project Objective 3: Increase capacity of hydrogen filling station; add additional vehicle; conduct safety workshop; develop a roadmap for hydrogen development; accelerate the development of photovoltaic components Project Objective 4: Perform research on the Proton Exchange membrane

08 HYDROGEN↗

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗

Next Generation Hydrogen Station Analysis

This presentation, part of the U.S. Department of Energy (DOE) Hydrogen Program 2022 Annual Merit Review and Peer Evaluation Meeting (AMR) in June 2022, discusses the project TA042, Next Generation Hydrogen Station Analysis.

DIRECT ENERGY CONVERSION,HYDROGEN↗

Performance of Existing Hydrogen Stations

In this presentation, the National Renewable Energy Laboratory presented aggregated analysis results on the performance of existing hydrogen stations, including performance, operation, utilization, maintenance, safety, hydrogen quality, and cost. The U.S. Department of Energy funds technology validation work at NREL through its National Fuel Cell Technology Evaluation Center (NFCTEC).

33 ADVANCED PROPULSION SYSTEMS↗

Hydrogen Infrastructure Market Readiness: Opportunities and Potential for Near-term Cost Reductions; Proceedings of the Hydrogen Infrastructure Market Readiness Workshop and Summary of Feedback Provided through the Hydrogen Station Cost Calculator

Recent progress with fuel cell electric vehicles (FCEVs) has focused attention on hydrogen infrastructure as a critical commercialization barrier. With major automakers focused on 2015 as a target timeframe for global FCEV commercialization, the window of opportunity is short for establishing a sufficient network of hydrogen stations to support large-volume vehicle deployments. This reportdescribes expert feedback on the market readiness of hydrogen infrastructure technology from two activities.

08 HYDROGEN↗

Next Generation Hydrogen Station Composite Data Products: Retail Stations (Data through Quarter 3 of 2019)

This publication includes 98 composite data products (CDPs) produced for next generation hydrogen stations, with data through the third quarter of 2019. These CDPs include data from retail stations only and represent the following analysis categories: deployment, safety, maintenance and reliability, performance, cost, utilization, hydrogen quality, and component energy.

08 HYDROGEN↗