Search NASA⌕ Search

SEARCH · Search NASA

Results for “HYGROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Aircraft water vapor measurements utilizing an aluminum oxide hygrometer

A hygrometer for water vapor measurements from an aircraft has been developed. An aluminum oxide hygrometer mounted in an aircraft Rosemount air temperature scoop was flown on NASA and USAF aircraft. Water vapor measurements were conducted up to 40,000 feet with penetration into the stratosphere. Good agreement was obtained with simultaneously flown remote sounders of water vapor. During transcontinental flights the hygrometer demonstrated adequate response to measure the natural variability of water vapor near the tropopause. Rapid response was demonstrated in pursuit of the jet wake of an F-104 at 35,000 feet.

Hilsenrath, E.↗

Aircraft water vapor measurements utilizing an aluminum oxide hygrometer

A hygrometer for water vapor measurements from an aircraft was developed. An aluminum oxide hygrometer mounted in an aircraft Rosemount air temperature scoop was flown on the NASA Convair 990 and on a USAF B-57 aircraft. Water vapor measurements from the Convair 990 were conducted up to 40,000 ft with penetration into the stratosphere. Good agreement was obtained with simultaneously flown remote sounders of water vapor. During transcontinental flights the hygrometer demonstrated adequate response to measure the natural variability of water vapor near the tropopause. Rapid response was demonstrated in pursuit of the jet wake of an F-104 at 35,000 ft.

Hilsenrath, E.↗

High-Performance Miniature Hygrometer

Relatively inexpensive hygrometer that occupies volume less than 4 in.(3) measures dewpoints as much as 100 degrees C below ambient temperatures, with accuracy of 0.1 degrees C. Field tests indicate accuracy and repeatability identical to those of state-of-the-art larger dewpoint hygrometers. Operates up to 100 times as fast as older hygrometers, and offers simplicity and small size needed to meet cost and performance requirements of many applications.

Van Zandt, Thomas R.↗

Use of an electrical resistance hygrometer to measure human sweat rates

The application of the resistance hygrometer as a tool to measure the localized sweat rate from the human body in both the active and passive sweat regions was studied. It was found that the physiological function of the skin membrane and fluid carrier transport phenomena from the outer skin have an indistinguishable effect on the observed findings from the instrument. The problems associated with the resistance hygrometer technique are identified and the usage of the instrument in the physiological experimentation from the engineering standpoint is evaluated.

Suga, T.↗

On the Accuracy of In Situ Water Vapor Measurements in the Troposphere and Lower Stratosphere with the Harvard Lyman-Alpha Hygrometer

In an effort to better constrain atmospheric water vapor mixing ratios and to understand the discrepancies between different measurements of water vapor in the stratosphere and troposphere, we have carefully examined data from the Harvard Lyman-alpha photofragment fluorescence hygrometer, which has flown on the NASA ER-2 aircraft from 1992 through 1998. The instrument is calibrated in the laboratory before and after each deployment, and the calibration is checked by direct absorption measurements in the troposphere. On certain flights, the ER-2 flew level tracks during which water vapor varied by up to 80 ppmv, under nearly constant atmospheric conditions. These flights provide a stringent test of our calibration via direct absorption and indicate agreement to within 3%. During the 1997 Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) mission, our Lyman-alpha instrument was compared with a new diode laser hygrometer from the Jet Propulsion Laboratory. Overall agreement was 5% during the June/July deployment and 1% for potential temperatures of 490 to 540 K. The accuracy of our instrument is shown to be +/-5 %, with an additional offset of at most 0.1 ppmv. Data from this instrument, combined with simultaneous measurements of CH4, and H2, are therefore ideal for studies of the hydrogen budget of the lower stratosphere.

Hintsa, Eric J.↗

Calibration and Data Retrieval Algorithms for the NASA Langley/Ames Diode Laser Hygrometer for the NASA Trace-P Mission

This paper describes the procedures and algorithms for the laboratory calibration and the field data retrieval of the NASA Langley / Ames Diode Laser Hygrometer as implemented during the NASA Trace-P mission during February to April 2000. The calibration is based on a NIST traceable dewpoint hygrometer using relatively high humidity and short pathlength. Two water lines of widely different strengths are used to increase the dynamic range of the instrument in the course of a flight. The laboratory results are incorporated into a numerical model of the second harmonic spectrum for each of the two spectral window regions using spectroscopic parameters from the HITRAN database and other sources, allowing water vapor retrieval at upper tropospheric and lower stratospheric temperatures and humidity levels. The data retrieval algorithm is simple, numerically stable, and accurate. A comparison with other water vapor instruments on board the NASA DC-8 and ER-2 aircraft is presented.

Podolske, James R.↗

Seasonal to Decadal Variations of Water Vapor in the Tropical Lower Stratosphere Observed with Balloon-Borne Cryogenic Frost Point Hygrometers

We investigated water vapor variations in the tropical lower stratosphere on seasonal, quasi-biennial oscillation (QBO), and decadal time scales using balloon-borne cryogenic frost point hygrometer data taken between 1993 and 2009 during various campaigns including the Central Equatorial Pacific Experiment (March 1993), campaigns once or twice annually during the Soundings of Ozone and Water in the Equatorial Region (SOWER) project in the eastern Pacific (1998-2003) and in the western Pacific and Southeast Asia (2001-2009), and the Ticosonde campaigns and regular sounding at Costa Rica (2005-2009). Quasi-regular sounding data taken at Costa Rica clearly show the tape recorder signal. The observed ascent rates agree well with the ones from the Halogen Occultation Experiment (HALOE) satellite sensor. Average profiles from the recent five SOWER campaigns in the equatorial western, Pacific in northern winter and from the three Ticosonde campaigns at Costa Rica (10degN) in northern summer clearly show two effects of the QBO. One is the vertical displacement of water vapor profiles associated with the QBO meridional circulation anomalies, and the other is the concentration variations associated with the QBO tropopause temperature variations. Time series of cryogenic frost point hygrometer data averaged in a lower stratospheric layer together with HALOE and Aura Microwave Limb Sounder data show the existence of decadal variations: The mixing ratios were higher and increasing in the 1990s, lower in the early 2000s, and probably slightly higher again or recovering after 2004. Thus linear trend analysis is not appropriate to investigate the behavior of the tropical lower stratospheric water vapor.

Fujiwara, M.↗

Polymeric electrolytic hygrometer

An improved flow-through electrolytic hygrometer is described which utilizes a long lasting oxidation-resistant, hollow fiber formed from persulfonic acid substituted polytetrafluoroethylene having closely spaced noble metal electrodes in contact with the inner and outer surfaces of the fiber. The fiber is disposed within a chamber so that the moisture-bearing gas passes in contact with at least one surface of the fiber. The electrodes are connected in series to a dc voltage supply and an ammeter. As the gas passes through the chamber, moisture absorbed into the wall of the fiber is electrolyzed to hydrogen and oxygen by the closely spaced electrodes. The amount of electricity required for electrolysis is proportional to the absorbed moisture and is observed on the ammeter.

Lawson, D. D.↗

Polymeric Electrolytic Hygrometer For Harsh Environments

Design of polymeric electrolytic hygrometer improved to meet need for reliable measurements of relative humidity in harsh environments of pulpmills and papermills. Redesigned sensor head features shorter, more-rigidly-held sensing element, less vulnerable than previous version to swell and loss of electrical contact. Useful for control of batch dryers in food and pharmaceutical industries.

Lawson, Daniel D.↗

Upper tropospheric water vapor: A field campaign of two Raman lidars, Airborne hygrometers, and Radiosondes

Water vapor in the atmosphere plays an important role in radiative transfer and the process of radiative balance so critical for understanding global change. It is the principal ingredient in cloud formation, one of the most difficult atmospheric processes to model, and the most variable component of the Earth-atmosphere albedo. And as a free molecule, it is the most active infrared absorber and emitter, thus, the most important greenhouse gas. The radiative impact of water vapor is important at all levels of the atmosphere. Even though moisture decreases by several orders-of-magnitude from the Earth's surface to the tropopause, recent research has shown that, from a radiative standpoint, a small percentage change in water vapor at any level is nearly equivalent. Therefore accurate and precise measurements of this important atmospheric constituent are needed at all levels to evaluate the full radiative impact. The need for improved measurements in the upper troposphere is particularly important because of the generally hostile (very dry and cold) conditions encountered. Because of the importance of water vapor to the understanding of radiative transfer, the Department of Energy's Atmospheric Radiation Measurements (ARM) program initiated a series of measurement campaigns at the Cloud And Radiation Testbed (CART) site in Oklahoma, especially focused on atmospheric water vapor. Three water vapor intensive observation period (water vapor IOP) campaigns were planned. Two of the water vapor IOP campaigns have been completed: the first IOP was held during the fall of 1996 with a focus on boundary layer water vapor measurements, and the second was conducted during the fall of 1997 with a focus on both boundary layer moisture e and moisture in the upper troposphere. This paper presents a review of the intercomparisons of water vapor measurements in the upper troposphere aquired during the second water vapor IOP. Data to be presented include water vapor measurements ements from: two Raman Lidars, the NASA Goddard Scanning Raman Lidar (SRL) and the CART Raman Lidar (CARL), a number of Vaisala radiosondes launched during the IOP campaign, and a dew point hygrometer flown on the University of North Dakota Cessna Citation Aircraft.

Melfi, S. Harvey↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Comparison of Upper Tropospheric Water Vapor from AIRS and Cryogenic Frostpoint Hygrometers

Upper tropospheric water vapor (UTWV) from the Atmospheric Infrared Sounder (AIRS) experiment on NASA's Aqua spacecraft has the potential of addressing several important climate questions. The specified AIRS system measurement uncertainty for water vapor is 20 percent absolute averaged over 2 km layers. Cryogenic frostpoint hygrometers (CFH) are balloon-borne water vapor sensors responsive from the surface into the lower stratosphere. Several dozen coincident, collocated CFH profiles have been obtained for AlRS validation. The combination of CFH sensitivity and sample size offers a statistically compelling picture of AIRS UTWV measurement capability. We present a comparison between CFH observations and AlRS retrievals. We focus on the altitude range from the middle troposphere up to heights at the limits of AlRS sensitivity to water vapor, believed to be around 100-1 50 hPa.

validation↗