Effect of Hygrothermal Ageing on PFSA ionomers’ Structure/Property Relationship
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Within building envelope science, the use of tools to model performance of the building envelope has evolved, and designers and scientists today have a myriad of tools available. Hygrothermal modeling is one such tool and, when used correctly, offers designers and forensic investigators important information about the movement of moisture within the building envelope. This traditional use of hygrothermal modeling is maturing as models are validated with field experience, creating a confidence in the modeling tools and their predictive capabilities. Based on this confidence, application of hygrothermal modeling to a more practical application is an evolution whose time has arrived. With changes in materials and methods, the performance of roofing systems can often times no longer be based on experience alone. Roofing contractors have been confounded by the unexplained and unplanned-for presence of moisture in roofing systems. Although hygrothermal modeling can be used to explain where the moisture came from, we propose that it should be used to prevent its occurrence. Unfortunately, more than 70 % of the roofing market is in reroofing, and oftentimes, a designer is not engaged in the roofing system design. Without the expertise of a designer and given that hygrothermal modeling is not well understood by the roofing industry, its adoption as a tool that can prevent problems has not been widely seen. This paper presents an extensive summary of hygrothermal modeling performed for roofing systems and then shows how the modeling can be used to create simple resources for roofing contractors to reduce the potential for moisture condensation at critical locations within a roofing system. The systems modeled have shown a propensity for moisture accumulation, and the use of hygrothermal modeling to eliminate these problems is a practical application of a building science tool that can greatly improve the durability of roofing systems.
Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.
Fiber-reinforced polymer composites have been highlighted as ideal candidates for structural applications in marine renewable energy devices, such as tidal turbines and wave energy converters. It is well understood that harsh marine environments can cause strength degradation of composite laminates, which has been extensively researched at the coupon scale; however, no research has investigated how this translates into larger-scale composite structures. This paper presents a subcomponent-scale study which investigates the effects of hygrothermal aging and subsequent static and fatigue characterization of thick composite T-bolt connections as part of a large, multilaboratory materials research effort. Of the glass-reinforced epoxy and vinylester-epoxy matrix composites tested, both showed measurable static strength degradation (4–36%) after being hygrothermally aged, even though the composite specimens were only partially saturated with water. Under tension–tension fatigue loading, the epoxy specimens performed very well in their dry states but exhibited significant degradation after hygrothermal aging. In comparison, the vinylester-epoxy specimens had much shorter fatigue lives in their dry states but exhibited no degradation after hygrothermal aging. Overall, this research demonstrates that hygrothermal aging can have significant effects on the ultimate strengths and fatigue lives of even partially saturated thick composite T-bolt connections, indicating that degradation of the outer plies on thick composite laminates can have pronounced effects on the whole structure. It discusses the challenges of building an understanding of the effects of harsh marine environments in large-scale composite structures.
Oak Ridge National Laboratory is developing a web tool, built on a rule-based expert system, that aids stakeholders in designing energy-efficient moisture-durable walls. Currently, the tool’s expert system database is mostly populated with expert opinion, but work is being done to incorporate durability assessment based on stochastic hygrothermal modeling. Chamber experiments have been conducted to validate the hygrothermal models. The measured temperature and humidity have been compared with those predicted by the hygrothermal model. Experiments and comparison to one-dimensional hygrothermal modeling results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The two walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The walls were sequentially exposed to different scenarios, including diffusion, wetting, air leakage and solar radiation. For the most part, the hygrothermal simulations can be successfully used to predict the performance of these wall systems for the moisture transport phenomenon. Errors between measured and simulated values decreased as measurements got closer to the interior side of the wall. The root mean square error was larger for relative humidity (up to 17.5%-RH for CMU) than for temperature (up to 4.5°C for CMU wall). The errors were larger for the CMU wall than the wood frame wall. The phenomenon, including liquid water, caused large discrepancies between measurement and simulation results, and simulated results showed slower drying of materials than measured results. The one-dimensional nature of the simulation model made simulating air leaks difficult but not impossible.
The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).
A shear deformation theory including residual thermal and moisture effects is developed for the analysis of either symmetric or unsymmetric laminates with mid-plane edge delamination under torsion loading. The theory is based on an assumed displacement field which includes shear deformation. The governing equations and boundary conditions are obtained from the principle of virtual work. The analysis of the (90/(+/- 45)(n)/(-/+ 45)(n)/90)(s) ECT mode 3 test lay-up indicates that there are no hygrothermal effects on the mode 3 strain energy release rate because the laminate, and both sublaminates above and below the delamination, are symmetric lay-ups. A further parametric study reveals that some other lay-ups can have negligible hygrothermal effects even when the sublaminates above and below the delamination are not symmetric about their own mid-planes. However, these lay-ups may suffer from distortion after the curing process. Another Interesting set of lay-ups investigated is a class of antisymmetric laminates with (+/-(theta/(theta -90)(2)/theta))(n) lay-ups. It is observed that when n takes on even numbers (2 and 4), both hygrothermal and mode 1 effects can be neglected. From this point of view, these lay-ups provide a way to determine the mode 3 toughness between two dissimilar layers. However, when n takes on odd numbers (1 and 3), both hygrothermal and mode 1 effects may be strong in these lay-ups. In particular, when theta equals 45 deg, the lay-ups are free from both hygrothermal and mode 1 effects irrespective of n.
Demands for engineering applications of high performance polymers, such as the polyaryletherketone families, have grown significantly in recent years. Fundamental knowledge on the mechanical behavior of such polymers, especially under harsh environments, is still lacking. In this study, the mechanical behavior and interfacial phenomena of a blend of polybenzimidazole (PBI) particles having sizes of about 50 μm and polyetheretherketone (PEEK) matrix at 50:50 weight ratio was characterized. PBI and PEEK are known to be incompatible with each other in the dry state. The possible influence of hygrothermal exposure on interfacial bonding between PEEK and PBI has been systematically studied. Under dry conditions, the PEEK matrix dominates the dynamic mechanical behavior, indicating no noticeable viscoelastic coupling between the two phases. After being exposed to hygrothermal conditions, the T g of the PEEK phase in the blend shifts to a lower temperature by as much as 26 °C. The extent of this shift is much greater than what is observed for neat PEEK alone under the same condition. Nanomechanical property mapping results indicate that the interfacial region is broadened after 288 °C hot water immersion treatment. The above finding strongly suggests the hygrothermal conditioning promotes apparent compatibility between PEEK and PBI. Likewise, the fracture behavior of the blend provides direct evidence that the interfacial adhesion is greater than the cohesive strength of either phase after water immersion. In the meantime, it is found that both fracture toughness and tensile strength of the blend are improved by water absorption at 60 °C, at the expense of a minor reduction in Young’s modulus. However, if the blend is exposed to hot water at 288 °C, all of the mechanical properties will deteriorate significantly. In conclusion, the possible causes of the mechanical property deterioration in the PEEK/PBI blend after hygrothermal treatment are discussed.
Abstract In this work, we have presented a comparison between effects of accelerated thermo-oxidative, hydrolytic and hygrothermal aging on the mechanical and chemical properties of a polyurethane based (PUB) adhesive. The adhesive is a flexible adhesive which is extensively used in automobile industry as a glass sealant. During service life it gets exposed to the hygrothermal environment and the integrity of matrix interface is most vulnerable. This study focuses on weighing and comparing effects of different aging environments on material behavior; and it shows that hygrothermal aging environment results as a competition between two sub-aging phenomena i.e., thermo-oxidation and hydrolytic aging. Samples were exposed to 0%RH, 80%RH and submerged condition in distilled water. Uni-axial tensile tests, and cross-link density analysis by swelling test were carried out on as-received and aged samples. The aging process was conducted at three different temperatures (60°C, 80°C and 95°C) and for four different exposure durations of 1, 10, 30, and 90 days. This work confirms that the effect of hygrothermal aging is a result of competition between thermo-oxidation and hydrolytic aging environments. The total mechanical and environmental damage incurred by specimens is a collaborative effect of all exposure environments involved i.e., aging time, temperature, oxygen, water and humidity. The results are in agreement with the chemical test outcomes as well.
The hygrothermal (heat and moisture) performance of buildings can be assessed by utilizing simulation tools. There are currently a number of available hygrothermal calculation tools available which vary in their degree of sophistication and runtime requirements. This report investigates three of the most commonly used models (WUFI, HAMT, and EMPD) to assess their limitations and potential to generate physically realistic results to prioritize improvements for EnergyPlus (which uses HAMT and EMPD). The outcome of the study shows that, out of these three tools, WUFI has the greatest hygrothermal capabilities. Limitations of these tools were also assessed including: WUFI’s inability to properly account for air leakage and transfer at surface boundaries; HAMT’s inability to handle air leakage, precipitationrelated moisture problems, or condensation problems from high relative humidity; and multiple limitations for EMPD as a simplified method to estimate indoor temperature and humidity levels and generally not used to estimate the hygrothermal performance of the building envelope materials. In conclusion, out of the three investigated simulation tools, HAMT has the greatest modeling potential, is open source, and we have prioritized specific features that can enable EnergyPlus to model all relevant heat and moisture transfer mechanisms that impact the performance of building envelope components.
Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.
Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.
Perfluorosulfonic-acid (PFSA) membranes are widely used as the solid electrolyte in electrochemical devices where their main functionalities are ion (proton) conduction and gas separation in a thermomechanically stable matrix. Due to prolonged operational requirements in these devices, PFSA membranes’ properties change with time due to hygrothermal aging. This paper studies the evolution of PFSA structure/property relationship changes during hygrothermal aging, including chemical changes leading to changes in ion-exchange capacity (IEC), nanostructure, water-uptake behavior, conductivity, and mechanical properties. Our findings demonstrate that with hygrothermal aging, the storage modulus increases, while IEC and water content decrease, consistent with the changes in nanostructure, that is, water- and crystalline-domain spacings inferred from small- and wide-angle X-ray scattering (SAXS/WAXS) experiments. In addition, the impact of aging is found to depend on the membrane's thermal prehistory and post-treatments, although universal correlations exist between nanostructural changes and water uptake. Lastly, the findings have impact on understanding lifetime, durability, and use of these and related polymers in various technologies.
This study investigates the hygrothermal aging behavior and thermomechanical properties of as-manufactured glass fiber-reinforced epoxy and thermoplastic composite tidal turbine blades. The blades were previously deployed in a marine environment and subsequently analyzed through a comprehensive suite of material characterization techniques, including hygrothermal aging, dynamic mechanical analysis (DMA), tensile testing and X-ray computed tomography (XCT). Hygrothermal aging experiments revealed that while thermoplastic composites exhibited lower overall water absorption (0.78% vs. 0.47%), they had significantly higher diffusion coefficients than epoxy (2.1 vs. 12.1 × 10 −13 m 2 s −1 ), suggesting faster saturation in operational environments. DMA results demonstrated that water ingress caused plasticization in epoxy matrices, reducing the glass transition temperature and increasing damping (112 °C to 104 °C), while thermoplastic composites showed more stable thermal behavior (87 °C glass transition temperature). Tensile testing revealed substantial reductions in ultimate strength (>40%) for both materials after prolonged water exposure, with minimal change in elastic modulus, highlighting the role of matrix degradation over fiber reinforcement. XCT image analysis showed that both composites were manufactured with high quality: no large voids or cracks were present, and the degree of misalignment was low. These findings inform future marine renewable energy composite designs by emphasizing the critical influence of moisture on long-term structural integrity and the need for optimized material systems in harsh marine environments. This work provides a rare real-world comparison of epoxy and recyclable thermoplastic tidal turbine blades, showing how laboratory aging tests and advanced imaging reveal the influence of material and manufacturing choices on long-term marine durability.
Abstract Glass fiber‐reinforced polymer composites are widely used in marine applications, including renewable energy devices and submarines, due to their strength‐to‐weight ratios and corrosion resistance. As sustainability becomes more important, recyclable thermoplastic composites are gaining attention in marine energy applications. These materials face harsh conditions such as high chloride water, UV radiation, pressurization, and thermal cycling, which can affect their durability and recyclability. This study examines the impact of hygrothermal aging on the recyclability of an Elium glass fiber (GF) composite. Samples were mechanically ground for recycling, and mechanical and thermal properties were compared between aged and unaged samples. After seawater aging, the tensile strength and modulus of the unaged composite dropped by 25% and 13% respectively, due to water ingress along the fiber‐matrix interface. The recycled composite showed reduced flexural strength as the long fiber composite was converted into short fibers during the process. Differential scanning calorimetry (DSC) revealed no change in glass transition temperature after aging. Weight loss (25%) was attributed to the thermal stability of the glass fibers. Dynamic mechanical analysis (DMA) showed that the storage modulus increased with aging, and fracture analysis confirmed a mixed mode of failure for aged composites. Highlights Hygrothermal aging lowers mechanical performance of Elium® GF composites. Failure mechanism tends to be matrix cracking and interface bonding. Glass transition temperature is not reduced by hygrothermal aging. Fractured composite was successfully recycled via thermoforming. Flexural strength of the recycled composite is lower.
The aeronautic structures normally operate under high levels of hygroscopic moisture from the surrounding environment at different temperature ranges while in service. Under such conditions, the behavior of laminate composite submitted to cyclic or static loadings can change drastically. In order to understand those effects in stitched fabrics, fatigue tests with open-hole specimens were carried out with a stress ratio of R = −1 and R = 0.1. The specimens were fatigue-tested as provided (environmental conditions) and after exposed to hygrothermal weathering conditions. Based on evidences from recent studies available in the open literature, e.g., effect of water diffusion on epoxy matrix, the overall results indicated a significant reduction in stiffness after the specimens are exposed to hygrothermal effects. The reduction in matrix stiffness, in this case, enhanced the fatigue strength in tension–tension load (R = 0.1) when compared to the specimens in normal conditions. The opposite occurs for the specimens loaded with stress ratio of R = −1, in which the delamination mechanisms changed during the loading reversion from tension to compression that promoted early delamination. Therefore, this process reduced the fatigue life of the specimens under hygrothermal condition. Then, by fractographic investigation, it was verified fracture patterns that regard to mode II damage in R = −1, in which mode II fracture toughness is known to decrease in the presence of water molecules.
Hygrothermal simulations provide insight into the energy performance and moisture durability of building envelope components under dynamic conditions. The inputs required for hygrothermal simulations are extensive, and carrying out simulations and analyses requires expert knowledge. An expert system, the Building Science Advisor (BSA), has been developed to predict the performance and select the energy-efficient and durable building envelope systems for different climates. The BSA consists of decision rules based on expert opinions and thousands of parametric simulation results for selected wall systems. The number of potential wall systems results in millions, too many to simulate all of them. We present how machine learning can help predict durability data, such as mold growth, while minimizing the number of simulations needed to run. The simulation results are used for training and validation of machine learning tools for predicting wall durability. We tested Artificial Neural Network (ANN) and Gradient Boosted Decision Trees (GBDT) for their applicability and model accuracy. Models developed with both methods showed adequate prediction performance (root mean square error of 0.195 and 0.209, respectively). Finally, we introduce how the information supports guidance for envelope design via an easy-to-use web-based tool that does not require the end-user to run hygrothermal simulations.
A variationally consistent theory is developed in order to derive the governing equations of anisotropic thin-walled beams with closed sections subjected to axial load, torsion, bending and hygrothermal loads. The theory is based on an asymptotical analysis of two-dimensional shell theory. Closed-form expressions for the beam stiffness coefficients, equivalent hygrothermal loads, stress and displacement fields are provided. The influence of material anisotropy and hygrothermal coefficients on the displacement field is identified. The analysis is applied to predict the response of composite beams under thermomechanical loading.