Search NASA⌕ Search

SEARCH · Search NASA

Results for “Head Movements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

MgADP Promotes Myosin Head Movement toward Actin at Low [Ca 2+ ] to Increase Force Production and Ca 2+ -Sensitivity of Contraction in Permeabilized Porcine Myocardial Strips

Myosin cross-bridges dissociate from actin following Mg 2+ -adenosine triphosphate (MgATP) binding. Myosin hydrolyses MgATP into inorganic phosphate (P i ) and Mg 2+ -adenosine diphosphate (ADP), and release of these hydrolysis products drives chemo-mechanical energy transitions within the cross-bridge cycle to power muscle contraction. Some forms of heart disease are associated with metabolic or enzymatic dysregulation of the MgATP-MgADP nucleotide pool, resulting in elevated cytosolic [MgADP] and impaired muscle relaxation. We investigated the mechanical and structural effects of increasing [MgADP] in permeabilized myocardial strips from porcine left ventricle samples. Sarcomere length was set to 2.0 µm at 28 °C, and all solutions contained 3% dextran T-500 to compress myofilament lattice spacing to near-physiological values. Under relaxing low [Ca 2+ ] conditions (pCa 8.0, where pCa = -log 10 [Ca 2+ ]), tension increased as [MgADP] increased from 0-5 mM. Complementary small-angle X-ray diffraction measurements show that the equatorial intensity ratio, I 1,1 /I 1,0 , also increased as [MgADP] increased from 0 to 5 mM, indicating myosin head movement away from the thick-filament backbone towards the thin-filament. Ca 2+ -activated force-pCa measurements show that Ca 2+ -sensitivity of contraction increased with 5 mM MgADP, compared to 0 mM MgADP. These data show that MgADP augments tension at low [Ca 2+ ] and Ca 2+ -sensitivity of contraction, suggesting that MgADP destabilizes the quasi-helically ordered myosin OFF state, thereby shifting the cross-bridge population towards the disordered myosin ON state. Together, these results indicate that MgADP enhances the probability of cross-bridge binding to actin due to enhancement of both thick and thin filament-based activation mechanisms.

60 APPLIED LIFE SCIENCES↗

SU-E-T-603: Analysis of Optical Tracked Head Inter-Fraction Movements Within Masks to Access Intracranial Immobilization Techniques in Proton Therapy

Purpose: We present a quantitative methodology utilizing an optical tracking system for monitoring head inter-fraction movements within brain masks to assess the effectiveness of two intracranial immobilization techniques. Methods and Materials: A 3-point-tracking method was developed to measure the mask location for a treatment field at each fraction. Measured displacement of mask location to its location at first fraction is equivalent to the head movement within the mask. Head movements for each of treatment fields were measured over about 10 fractions at each patient for seven patients; five treated in supine and two treated in prone. The Q-fix Base-of-Skull head frame was used in supine while the CIVCO uni-frame baseplate was used in prone. Displacements of recoded couch position of each field post imaging at each fraction were extracted for those seven patients. Standard deviation (S.D.) of head movements and couch displacements was scored for statistical analysis. Results: The accuracy of 3PtTrack method was within 1.0 mm by phantom measurements. Patterns of head movement and couch displacement were similar for patients treated in either supine or prone. In superior-inferior direction, mean value of scored standard deviations over seven patients were 1.6 mm and 3.4 mm for the head movement and the couch displacement, respectively. The result indicated that the head movement combined with a loose fixation between the mask-to-head frame results large couch displacements for each patient, and also large variation between patients. However, the head movement is the main cause for the couch displacement with similar magnitude of around 1.0 mm in anterior-posterior and lateral directions. Conclusions: Optical-tracking methodology independently quantifying head movements could improve immobilization devices by correctly acting on causes for head motions within mask. A confidence in the quality of intracranial immobilization techniques could be more efficient by eliminating the need for frequent imaging.

60 APPLIED LIFE SCIENCES↗

Evaluating the Impact of Head Rotation Amplification on Virtual Reality Training Effectiveness

Virtual reality (VR) systems have been proposed for use in numerous training scenarios, such as room clearing, which require the trainee to maintain spatial awareness. But many VR training systems lack a fully surrounding display, requiring trainees to use a combination of physical and virtual turns to view the environment, thus decreasing spatial awareness. One solution to this problem is to amplify head rotations, such that smaller physical turns are mapped to larger virtual turns, allowing trainees to view the surrounding environment with head movements alone. For example, in a multi-monitor system covering only a 90-degree field of regard, head rotations could be amplified four times to allow the user to see the entire 360-degree surrounding environment. This solution is attractive because it can be used with lower-cost VR systems and does not require virtual turning. However, the effects of amplified head rotations on spatial awareness and training transfer are not well understood. We hypothesized that small amounts of amplification might be tolerable, but that larger amplifications might cause trainees to become disoriented and to have decreased task performance and training transfer. In this paper, we will present our findings from an experiment designed to investigate these hypotheses. The experiment placed users in a virtual warehouse and asked them to move from room to room, counting objects placed around them in space. We varied the amount of amplification applied during these trials, and also varied the type of display used (head-mounted display or CAVE). We measured task performance and spatial awareness. We then assessed training transfer in an assessment environment with a fully surrounding display and no amplification. The results of this study will inform VR training system developers about the potential negative effects of using head rotation amplification and contribute to more effective VR training system design.

3D interaction↗

Advances in the Dynallax solid-state dynamic parallax barrier autostereoscopic visualization display system.

A solid-state dynamic parallax barrier autostereoscopic display mitigates some of the restrictions present in static barrier systems such as fixed view-distance range, slow response to head movements, and fixed stereo operating mode. By dynamically varying barrier parameters in real time, viewers may move closer to the display and move faster laterally than with a static barrier system, and the display can switch between 3D and 2D modes by disabling the barrier on a per-pixel basis. Moreover, Dynallax can output four independent eye channels when two viewers are present, and both head-tracked viewers receive an independent pair of left-eye and right-eye perspective views based on their position in 3D space. The display device is constructed by using a dual-stacked LCD monitor where a dynamic barrier is rendered on the front display and a modulated virtual environment composed of two or four channels is rendered on the rear display. Dynallax was recently demonstrated in a small-scale head-tracked prototype system. This paper summarizes the concepts presented earlier, extends the discussion of various topics, and presents recent improvements to the system.

97 MATHEMATICS AND COMPUTING↗

General Anesthesia Versus Conscious Sedation in Acute Stroke Treatment: The Importance of Head Immobilization

PurposeWhile today mechanical thrombectomy is an established treatment option for main branch occlusions in anterior circulation stroke, there is still an ongoing debate on the kind of anesthesia to be preferred. Introducing a simple method for head stabilization, we analyzed safety and duration of endovascular recanalization procedures under general anesthesia (GA) and conscious sedation (CS).MethodsWe retrospectively identified 84 consecutive patients who underwent mechanical thrombectomy owing to acute anterior circulation stroke. Fifty-three were treated under GA and 31 under CS equipped with a standard cervical collar to reduce head movement. We evaluated recanalization results, in-house time to start recanalization, procedure times, technical and clinical complication rates, and conversion rates from CS to GA.ResultsRecanalization of mTICI ≥2b was achieved in 80 % under CS and in 81 % under GA. Median in-house time to start recanalization for CS was 60 min (IQR 28; 44–72) and 77 min (IQR 23; 68–91) for GA (P = 0.001). Median procedure time under CS was 35 min (IQR 43; 69–25) and 41 min (IQR 43; 66–23) for GA (P = 0.9). No major complications such as ICH occurred in either group, and no conversions from CS to GA were necessary.ConclusionMechanical thrombectomy can be performed faster and safely under CS in combination with simple head immobilization using a standard cervical collar.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concept of an upright wearable positron emission tomography imager in humans

Abstract Background Positron Emission Tomography ( PET ) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_ PET ) and conducted tests in phantoms and four human volunteers. Methods Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET / CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET / CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROI s. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

60 APPLIED LIFE SCIENCES↗

Structural determinants of protocadherin-15 mechanics and function in hearing and balance perception

The vertebrate inner ear, responsible for hearing and balance, is able to sense minute mechanical stimuli originating from an extraordinarily broad range of sound frequencies and intensities or from head movements. Integral to these processes is the tip-link protein complex, which conveys force to open the inner-ear transduction channels that mediate sensory perception. Protocadherin-15 and cadherin-23, two atypically large cadherins with 11 and 27 extracellular cadherin (EC) repeats, are involved in deafness and balance disorders and assemble as parallel homodimers that interact to form the tip link. Here we report the X-ray crystal structure of a protocadherin-15 + cadherin-23 heterotetrameric complex at 2.9-Å resolution, depicting a parallel homodimer of protocadherin-15 EC1-3 molecules forming an antiparallel complex with two cadherin-23 EC1-2 molecules. In addition, we report structures for 10 protocadherin-15 fragments used to build complete high-resolution models of the monomeric protocadherin-15 ectodomain. Molecular dynamics simulations and validated crystal contacts are used to propose models for the complete extracellular protocadherin-15 parallel homodimer and the tip-link bond. Steered molecular dynamics simulations of these models suggest conditions in which a structurally diverse and multimodal protocadherin-15 ectodomain can act as a stiff or soft gating spring. These results reveal the structural determinants of tip-link–mediated inner-ear sensory perception and elucidate protocadherin-15’s structural and adhesive properties relevant in disease.

59 BASIC BIOLOGICAL SCIENCES↗

Cusps enable line attractors for neural computation

Here, line attractors in neuronal networks have been suggested to be the basis of many brain functions, such as working memory, oculomotor control, head movement, locomotion, and sensory processing. In this paper, we make the connection between line attractors and pulse gating in feed-forward neuronal networks. In this context, because of their neutral stability along a one-dimensional manifold, line attractors are associated with a time-translational invariance that allows graded information to be propagated from one neuronal population to the next. To understand how pulse-gating manifests itself in a high-dimensional, nonlinear, feedforward integrate-and-fire network, we use a Fokker-Planck approach to analyze system dynamics. We make a connection between pulse-gated propagation in the Fokker-Planck and population-averaged mean-field (firing rate) models, and then identify an approximate line attractor in state space as the essential structure underlying graded information propagation. An analysis of the line attractor shows that it consists of three fixed points: a central saddle with an unstable manifold along the line and stable manifolds orthogonal to the line, which is surrounded on either side by stable fixed points. Along the manifold defined by the fixed points, slow dynamics give rise to a ghost. We show that this line attractor arises at a cusp catastrophe, where a fold bifurcation develops as a function of synaptic noise; and that the ghost dynamics near the fold of the cusp underly the robustness of the line attractor. Understanding the dynamical aspects of this cusp catastrophe allows us to show how line attractors can persist in biologically realistic neuronal networks and how the interplay of pulse gating, synaptic coupling, and neuronal stochasticity can be used to enable attracting one-dimensional manifolds and, thus, dynamically control the processing of graded information.

59 BASIC BIOLOGICAL SCIENCES↗

Awake animal SPECT: Overview and initial results

A SPECT / X-ray CT system configured at Johns Hopkins University to image the biodistribution of radiopharmaceuticals in unrestrained, un-anesthetized mice has been constructed and tested on awake mice. The system was built by Thomas Jefferson National Accelerator Facility and Oak Ridge National Laboratory. SPECT imaging is accomplished using two gamma cameras, 10 cm × 20 cm in size based on a 2 × 4 array of Hamamatsu H8500 flat panel position sensitive photomultiplier tubes. A real-time optical tracking system utilizing three infrared cameras provides time stamped pose data of an awake mouse head during a SPECT scan. The six degrees of freedom (three translational and three rotational) pose data are used for motion correction during 3-D tomographic list-mode iterative image reconstruction. SPECT reconstruction of awake, unrestrained mice with motion compensation for head movement has been accomplished.

43 PARTICLE ACCELERATORS↗

Coincidence Anticipation Timing Responses with Head Tracking and Eye Tracking

Head tracking movements are common in interceptive tasks. The benefits of these movements are unclear. The purpose of this study was to compare coincidence anticipation timing (CAT) responses for a simulated approaching object when the eyes were used in tracking the object and when the head was used in tracking the object.A total of 29 subjects participated. A Bassin Anticipation Timer consisting of a track of sequentially illuminated lights was used to simulate an approaching object at velocities of 223 cm · s -1 to 894 cm · s -1 . Each velocity was used 10 times under 2 conditions. In one condition, subjects were told to turn the eyes with the stimulus. In the other condition, subjects viewed the stimulus through apertures and were told to turn the head with the stimulus. Subjects pushed a button to coincide with illumination of the final light on the track. Signed CAT errors, unsigned CAT errors, and variable CAT errors were compared between the head movement (HM) and eye movement (EM) conditions. No significant differences were noted for the signed errors (mean signed error at 894 cm · s -1 ; 10.3 ± 75.4 ms (HM), -16.1 ± 51.0 ms (EM). However, the unsigned and variable errors were significantly larger at some stimulus velocities in the head movement condition [mean unsigned error at 894 cm · s -1 : 82.6.0 ± 45.9 ms (HM), 59.0 ± 22.4 ms (EM); mean variable error at 894 cm · s -1 ; 78.0 ± 37.8 ms (HM), 49.2 ± 17.1ms (EM)]. DISCUSSION: Head movement did not result in improved CAT performance compared to eye movements. Further work will be required to determine whether these results are generalizable to situations where head tracking is required but apertures are not worn.

Biophysics↗

SU-C-210-07: Assessment of Intra-/Inter-Fractional Internal Tumor and Organ Movement in Radiotherapy of Head and Neck Cancer Using On-Board Cine MRI

Purpose: Head and neck (H&N) internal organ motion has previously been determined with low frequency and temporary nature based on population-based pre- and post-treatment studies. Using immobilization masks and adding a 4–6 mm planning-tumor-volume margin, geometric uncertainties of patients are routinely considered clinically inconsequential in H&N radiotherapy. Using the first commercially-available MR-IGRT system, we conducted the first quantitative study on inter-patient, intra- and inter-fractional H&N internal motion patterns to evaluate the necessity of individualized asymmetric internal margins. Methods: Ninety cine sagittal MR image sequences were acquired during the entire treatment course (6–7 weeks) of three H&N cancer patients using the ViewRay™ MR-IGRT system. The images were 5 mm thick and acquired at 4 frames/per second. One of the patients had a tracheostomy tube. The cross-sectional H&N airway (nasopharynx, oropharynx, and laryngopharynx portions) movement was analyzed comprehensively using in-house developed motion detection software. Results: Large inter-patient variations of swallowing frequency (0–1 times/per fraction), swallowing duration (1–3 seconds), and pharyngeal cross-sectional area (238–2516 mm2) were observed. Extensive pharyngeal motion occurred during swallowing, while nonzero and periodic change of airway geometry was observed in resting. For patient 1 with tracheostomy tube replacement, 30.3%, 30.0%, 48.7% and 0.3% of total frames showed ≥ 4 mm displacements in the anterior, posterior, inferior, and superior airway boundaries, respectively; similarly, (5.7%, 0.0%, 0.0%, 0.3%) and (23.3%, 0.0%, 35.7%, 1.7%) occurred for patients 2 and 3. Area overlapping coefficients with respect to the first frame were 76.3+/−6.4%, 90.3+/−0.6%, and 92.3+/−1.2% for the three patients, respectively. Conclusion: Both the resting and swallowing motions varied in frequency and amplitude among the patients and across fractions of a patient’s treatment. Patients receiving surgery that alters their respiratory and swallowing behavior can have significant intra-fractional internal motion. Patient-specific organ/tumor motion analysis may yield individualized asymmetric internal margins and improve the therapeutic ratio.

60 APPLIED LIFE SCIENCES↗

Reverse actin sliding triggers strong myosin binding that moves tropomyosin

Actin/myosin interactions in vertebrate striated muscles are believed to be regulated by the 'steric blocking' mechanism whereby the binding of calcium to the troponin complex allows tropomyosin (TM) to change position on actin, acting as a molecular switch that blocks or allows myosin heads to interact with actin. Movement of TM during activation is initiated by interaction of Ca{sup 2+} with troponin, then completed by further displacement by strong binding cross-bridges. We report x-ray evidence that TM in insect flight muscle (IFM) moves in a manner consistent with the steric blocking mechanism. We find that both isometric contraction, at high [Ca{sup 2+}], and stretch activation, at lower [Ca{sup 2+}], develop similarly high x-ray intensities on the IFM fourth actin layer line because of TM movement, coinciding with x-ray signals of strong-binding cross-bridge attachment to helically favored 'actin target zones.' Vanadate (Vi), a phosphate analog that inhibits active cross-bridge cycling, abolishes all active force in IFM, allowing high [Ca{sup 2+}] to elicit initial TM movement without cross-bridge attachment or other changes from relaxed structure. However, when stretched in high [Ca{sup 2+}], Vi-'paralyzed' fibers produce force substantially above passive response at pCa {approx} 9, concurrent with full conversion from resting to active x-ray pattern, including x-ray signals of cross-bridge strong-binding and TM movement. This argues that myosin heads can be recruited as strong-binding 'brakes' by backward-sliding, calcium-activated thin filaments, and are as effective in moving TM as actively force-producing cross-bridges. Such recruitment of myosin as brakes may be the major mechanism resisting extension during lengthening contractions.

59 BASIC BIOLOGICAL SCIENCES↗

Compact and mobile high resolution PET brain imager

A brain imager includes a compact ring-like static PET imager mounted in a helmet-like structure. When attached to a patient's head, the helmet-like brain imager maintains the relative head-to-imager geometry fixed through the whole imaging procedure. The brain imaging helmet contains radiation sensors and minimal front-end electronics. A flexible mechanical suspension/harness system supports the weight of the helmet thereby allowing for patient to have limited movements of the head during imaging scans. The compact ring-like PET imager enables very high resolution imaging of neurological brain functions, cancer, and effects of trauma using a rather simple mobile scanner with limited space needs for use and storage.

47 OTHER INSTRUMENTATION↗

Bayesian State-Space Modeling Framework for Understanding and Predicting Golden Eagle Movements Using Telemetry Data

Predicting raptor movements through a wind power plant under given atmospheric and topographical conditions is a crucial first step in the overall goal of quantifying the risk of turbine-related collisions and mortalities. Extracting behavioral traits of golden eagles (Aquila chrysaetos) from telemetry data requires the fusion of noisy and sparse movement data (location, heading, velocity) with a stochastic mathematical representation of the eagles' decision-making processes. In this study, we framed this problem in a Bayesian state-space framework where both observations and decision-making are assumed to be stochastic processes connected through hidden states (mode of flight, intent), and the unknown model parameters are assumed to be random variables that are calibrated using the available telemetry data. This framework allowed for rigorous consideration of underlying uncertainties while allowing for both data and prior biological knowledge to contribute to a probabilistic and predictive agent-based movement model. We implemented and applied the Bayesian framework to understand movement behavior of 23 GPS-tagged golden eagles travelling in the western US for years 2019 and 2020. Our preliminary findings show that the Bayesian state-space framework provides a robust inverse modeling apparatus to decode eagle behavioral characteristics from telemetry data. This study was primarily aimed at verifying and validating the framework with selected golden eagle tracks (both long- and short-ranged), with future research aimed at extending the framework to include multi-mode flight, consideration of atmospheric data and uplift mechanisms, eagle-to-eagle interaction, and eagle-to-turbine interaction.

Bayesian modeling↗

Assessing the Impact of Mirror Technology on Driver Perception and Safety: Traditional vs. Camera-Based Systems

Camera-based mirror systems (CBMS) are being adopted by commercial fleets based on the potential improvements to operational efficiency through improved aerodynamics, resulting in better fuel economy, improved maneuverability, and the potential improvement for overall safety. Until CBMS are widely adopted it will be expected that drivers will be required to adapt to both conventional glass mirrors and CBMS which could have potential impact on the safety and performance of the driver when moving between vehicles with and without CBMS. To understand the potential impact to driver perception and safety, along with other human factors related to CBMS, laboratory testing was performed to understand the impact of CBMS and conventional glass mirrors. Drivers were subjected to various, nominal driving scenarios using a truck equipped with conventional glass mirrors, CBMS, and both glass mirrors and CBMS, to observe the differences in metrics such as head and eye movement, reaction time, and perception of distance. The finds from this study will serve as the baseline measurements for future research regarding off-nominal driving scenarios and hardware failures of CBMS, as well as inform potential future policy regarding CBMS for the use in commercial vehicles in lieu of conventional glass mirrors.

Siekmann, Adam [ORNL] (ORCID:0000000284653935)↗

Awake Animal Imaging Motion Tracking Software

The Awake Animal Motion Tracking Software code calculates the 3D movement of the head motion of a live, awake animal during a medical imaging scan. In conjunction with markers attached to the head, images acquired from multiple cameras are processed and marker locations precisely determined. Using off-line camera calibration data, the 3D positions of the markers are calculated along with a 6 degree of freedom position and orientation (pose) relative to a fixed initial position. This calculation is performed in real time at frame rates up to 30 frames per second. A time stamp with microsecond accuracy from a time base source is attached to each pose measurement.

Goddard, James↗