BY-110 Headspace Sampling Comparison Test: Volume 1

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BY-110 Headspace Sampling Comparison Test: Volume 2: Raw Data

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗

GNS Castor V/21 Headspace Gas Sampling 2014

Prior to performing an internal visual inspection, samples of the headspace gas of the GNS Castor V/21 cask were taken on June 12, 2014. These samples were taken in support of the CREIPI/Japanese nuclear industry effort to validate fuel integrity without visual inspection by measuring the 85 Kr content of the cask headspace

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

Low Molecular Weight Volatile Organic Compounds Indicate Grazing by the Marine Rotifer Brachionus plicatilis on the Microalgae Microchloropsis salina

Microalgae produce specific chemicals indicative of stress and/or death. The aim of this study was to perform non-destructive monitoring of algal culture systems, in the presence and absence of grazers, to identify potential biomarkers of incipient pond crashes. Here, we report ten volatile organic compounds (VOCs) that are robustly generated by the marine alga, Microchloropsis salina, in the presence and/or absence of the marine grazer, Brachionus plicatilis. We cultured M. salina with and without B. plicatilis and collected in situ volatile headspace samples using thermal desorption tubes over the course of several days. Data from four experiments were aggregated, deconvoluted, and chromatographically aligned to determine VOCs with tentative identifications made via mass spectral library matching. VOCs generated by algae in the presence of actively grazing rotifers were confirmed via pure analytical standards to be pentane, 3-pentanone, 3-methylhexane, and 2-methylfuran. Six other VOCs were less specifically associated with grazing but were still commonly observed between the four replicate experiments. Through this work, we identified four biomarkers of rotifer grazing that indicate algal stress/death. This will aid machine learning algorithms to chemically define and diagnose algal mass production cultures and save algae cultures from imminent crash to make biofuel an alternative energy possibility.

headspace sampling↗

Comparing π‐complexation capabilities of ionic liquids containing silver(I) and copper(I) ions by headspace single drop microextraction in combination with high‐performance liquid chromatography

Selective π‐complexation capabilities of silver(I) and copper(I) ions can be effectively facilitated in ionic liquids. To understand the effects of environmental factors that influence the π‐complexation of these metal ions with analytes, techniques that employ small volumes of ionic liquid that can be readily analyzed are desired. In this study, headspace single drop microextraction coupled with HPLC is used to investigate a diverse set of environmental factors on the metal ion‐mediated complexation with aromatic compounds in ionic liquid media. Silver(I) and copper(I) bis[(trifluoromethyl)sulfonyl]imide salts were both studied by dissolving them in the 1‐decyl‐3‐methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ionic liquid and employing the mixture as extraction media for aromatic compounds. Water and acetonitrile within the sample solution were observed to interfere with the complexation of silver(I) ions and aromatic compounds, while ethylene glycol and triethylene glycol did not. The temperature and extraction times were optimized to fully facilitate the π‐complexation capabilities of metal ions in ionic liquid media. Partition coefficients between the sample headspace and metal ion were determined using a three‐phase equilibria model. Although no discernable difference in analyte partitioning between the headspace and ionic liquid solvent was observed, analyte partition coefficients to silver(I) ion tended to be greater compared to copper(I) ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Design of an Online Electrochemical Mass Spectrometry System to Study Gas Evolution from Cells with Lean and Volatile Electrolytes

Gas evolution in high-energy Li-ion batteries remains a pervasive problem for a multitude of chemistries, jeopardizing the electrochemical performance and safety for consumers of electric vehicles. Many electrode–electrolyte degradation processes evolve gasses that may be detected in-situ with online electrochemical mass spectrometry (OEMS). In this work, details are provided for the setup and validation of an OEMS system that operates well under lean and volatile electrolyte conditions. Quite notably, the OEMS cells with only 40 µL of electrolyte and intermittent headspace sampling exhibit comparable electrochemical performance to flooded coin-cells. It is demonstrated that the onset time, shape, and magnitude of the gas evolution profiles calculated from mass spectrometer measurements match well to a known pressure reference through the use of an empirically determined fraction of removal. The off-gassing characteristics from a set of layered-oxide materials, NMC532, NMC811, and LNO, are used to further validate the OEMS setup against the literature. It is shown that many of the features present in the OEMS curves for equivalent systems from other groups are captured by this OEMS system. Finally, at an upper cut-off voltage of 4.4 V, LNO exhibits an intense release of CO 2 , O 2 , and CO gas relative to NMC532 and NMC811.

25 ENERGY STORAGE↗

Proton Transfer Time-of-Flight Mass Spectrometer

The Proton Transfer Reaction Mass Spectrometer (PTRMS) measures gas-phase compounds in ambient air and headspace samples before using chemical ionization to produce positively charged molecules, which are detected with a time-of-flight (TOF) mass spectrometer. This ionization method uses a gentle proton transfer reaction method between the molecule of interest and protonated water, or hydronium ion (H 3 O + ), to produce limited fragmentation of the parent molecule. The ions produced are primarily positively charged with the mass of the parent ion, plus an additional proton. Ion concentration is determined by adding the number of ions counted at the molecular ion’s mass-to-charge ratio to the number of air molecules in the reaction chamber, which can be identified according to the pressure levels in the reaction chamber. The PTRMS allows many volatile organic compounds in ambient air to be detected at levels from 10–100 parts per trillion by volume (pptv). The response time is 1 to 10 seconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alviso Weekly Update -- November 2018

Compare two different vial septa for possible use in irradiation aging of materials sensitive to flame or heat and to allow for in-situ headspace sampling.

36 MATERIALS SCIENCE↗

Cryo-GCMS Outgassing Screening: Thermal Filler Materials

A study was conducted to investigate the outgassing characteristics of four thermal filler materials. The purpose of this screening was to identify any outgassing products that might be considered reactive, specifically compounds that could result in corrosion in the systems where these materials are used. A range of compounds was observed in the sample headspaces, though most do not stand out as being known reactive species of concern. However, several halogenated compounds and sulfurous compounds- classes compounds known to facilitate corrosion reactions under certain conditions- were observed in low concentrations. The TFLEX 760 exhibited the highest total outgassing, while the GR130 had the lowest. Therm-a-Gap75 and the Si thermal grease exhibited very similar outgassing profiles. It is difficult to predict the extent to which any given compound observed in an analysis of this type might pose a risk in an actual system; factors such as temperature, system geometry, concentration, and gas conductance all play a role in the kinetics governing chemical reactions. It is recommended that the results of these analyses are shared with pertinent materials SMEs familiar with the system(s) in question to evaluate potential risks.

36 MATERIALS SCIENCE↗

Magnetically-induced solid-phase microextraction fiber actuation system for quantitative headspace and liquid sampling

A magnetically-induced SPME fiber actuation system includes a SPME fiber holder and a SPME fiber holder actuator, for holding and magnetically actuating a SPME fiber assembly. The SPME fiber holder has a plunger with a magnetic material to which the SPME fiber assembly is connected, and the magnetic SPME fiber holder actuator has an elongated barrel with a loading chamber for receiving the SPME fiber assembly-connected SPME fiber holder, and an external magnet which induces axial motion of the magnetic material of the plunger to extend/retract the SPME fiber from/into the protective needle of the SPME fiber assembly.

47 OTHER INSTRUMENTATION↗

Peroxide-modified titanium dioxide: a chemical analog of putative Martian soil oxidants

Hydrogen peroxide chemisorbed on titanium dioxide (peroxide-modified titanium dioxide) is investigated as a chemical analog to the putative soil oxidants responsible for the chemical reactivity seen in the Viking biology experiments. When peroxide-modified titanium dioxide (anatase) was exposed to a solution similar to the Viking labeled release (LR) experiment organic medium, CO2 gas was released into the sample cell headspace. Storage of these samples at 10 degrees C for 48 hr prior to exposure to organics resulted in a positive response while storage for 7 days did not. In the Viking LR experiment, storage of the Martian surface samples for 2 sols (approximately 49 hr) resulted in a positive response while storage for 141 sols essentially eliminated the initial rapid release of CO2. Heating the peroxide-modified titanium dioxide to 50 degrees C prior to exposure to organics resulted in a negative response. This is similar to, but not identical to, the Viking samples where heating to approximately 46 degrees C diminished the response by 54-80% and heating to 51.5 apparently eliminated the response. When exposed to water vapor, the peroxide-modified titanium dioxide samples release O2 in a manner similar to the release seen in the Viking gas exchange experiment (GEx). Reactivity is retained upon heating at 50 degrees C for three hours, distinguishing this active agent from the one responsible for the release of CO2 from aqueous organics. The release of CO2 by the peroxide-modified titanium dioxide is attributed to the decomposition of organics by outer-sphere peroxide complexes associated with surface hydroxyl groups, while the release of O2 upon humidification is attributed to more stable inner-sphere peroxide complexes associated with Ti4+ cations. Heating the peroxide-modified titanium dioxide to 145 degrees C inhibited the release of O2, while in the Viking experiments heating to this temperature diminished but did not eliminated the response. Although the thermal stability of the titanium-peroxide complexes in this work is lower than the stability seen in the Viking experiments, it is expected that similar types of complexes will form in titanium containing minerals other than anatase and the stability of these complexes will vary with surface hydroxylation and mineralogy.

Review↗

Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

Davis, Morgan P.↗

Scientific Value of Including an Atmospheric Sample as Part of Mars Sample Return (MSR)

The Perseverance rover is meant to collect samples of the martian surface for eventual return to Earth. The headspace gas present over the solid samples within the sample tubes will be of significant scientific interest for what it reveals about the interactions of the solid samples with the trapped atmosphere and for what it will reveal about the martian atmosphere itself. However, establishing the composition of the martian atmosphere will require other dedicated samples. The headspace gas as the sole atmospheric sample is problematic for many reasons. The quantity of gas present within the sample tube volume is insufficient for many investigations, and there will be exchange between solid samples, headspace gas, and tube walls. Importantly, the sample tube materials and preparation were not designed for optimal Mars atmospheric gas collection and storage as they were not sent to Mars in a degassed evacuated state and have been exposed to both Earth's and Mars' atmospheres. Additionally, there is a risk of unconstrained seal leakage in transit back to Earth, which would allow fractionation of the sample (leak-out) and contamination (leak-in). The science return can be improved significantly (and, in some cases, dramatically) by adding one or more of several strategies listed here in increasing order of effectiveness and difficulty of implementation: (1) Having Perseverance collect a gas sample in an empty sample tube, (2) Collecting gas in a newly-designed, valved, sample-tube-sized vessel that is flown on either the Sample Fetch Rover (SFR) or the Sample Retrieval Lander (SRL), (3) Adding a larger (50-100 cc) dedicated gas sampling volume to the Orbiting Sample container (OS), (4) Adding a larger (50-100 cc) dedicated gas sampling volume to the OS that can be filled with compressed martian atmosphere.

Timothy D. Swindle↗

Headspace analysis of foams and fixatives

In the process of decontaminating and decommissioning (D&D) older nuclear facilities, special precautions must be taken with removable or airborne contamination. One possible strategy utilizes foams and fixatives to affix these loose contaminants. Many foams and fixatives are already commercially available, either generically or sold specifically for D&D. However, due to a lack of revelant testing in a radioactive environment, additional verification is needed to confirm that these products not only affix contamination to their surfaces, but also will function in a D&D environment. Several significant safety factors, including flammability and worker safety, can be analyzed through the process of headspace analysis, a technique that analyzes the off gas formed before or during the curing process of the foam/fixative, usually using gas chromatography-mass spectrometry (GC-MS). This process focuses on the volatile components of a chemical, which move freely between the solid/liquid form within the sample and the gaseous form in the area above the sample (the headspace). Between possibly hot conditions in a D&D situation and heat created in a foaming reaction, the volatility of many chemicals can change, and thus different gasses can be released at different times throughout the reaction. This project focused on analysis of volatile chemicals involved in the process of using foams and fixatives to identify any potential hazardous or flammable compounds.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗