Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The interpretation of temperature and salinity variables in numerical ocean model output and the calculation of heat fluxes and heat content

Abstract. The international Thermodynamic Equation of Seawater 2010 (TEOS-10) defined the enthalpy and entropy of seawater, thus enabling the global ocean heat content to be calculated as the volume integral of the product of in situ density, ρ, and potential enthalpy, h0 (with reference sea pressure of 0 dbar). In terms of Conservative Temperature, Θ, ocean heat content is the volume integral of ρcp0Θ, where cp0 is a constant “isobaric heat capacity”. However, many ocean models in the Coupled Model Intercomparison Project Phase 6 (CMIP6) as well as all models that contributed to earlier phases, such as CMIP5, CMIP3, CMIP2, and CMIP1, used EOS-80 (Equation of State – 1980) rather than the updated TEOS-10, so the question arises of how the salinity and temperature variables in these models should be physically interpreted, with a particular focus on comparison to TEOS-10-compliant observations. In this article we address how heat content, surface heat fluxes, and the meridional heat transport are best calculated using output from these models and how these quantities should be compared with those calculated from corresponding observations. We conclude that even though a model uses the EOS-80, which expects potential temperature as its input temperature, the most appropriate interpretation of the model's temperature variable is actually Conservative Temperature. This perhaps unexpected interpretation is needed to ensure that the air–sea heat flux that leaves and arrives in atmosphere and sea ice models is the same as that which arrives in and leaves the ocean model. We also show that the salinity variable carried by present TEOS-10-based models is Preformed Salinity, while the salinity variable of EOS-80-based models is also proportional to Preformed Salinity. These interpretations of the salinity and temperature variables in ocean models are an update on the comprehensive Griffies et al. (2016) paper that discusses the interpretation of many aspects of coupled Earth system models.

54 ENVIRONMENTAL SCIENCES↗

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam↗

Power Plant Testing of Ultrasonic Measurements of Temperature Distributions and Heat Fluxes to Heat Exchange Surfaces

Extreme environmental conditions are common in energy conversion applications, in which the most hardened insertion sensors often do not perform reliably for long. On the other hand, ultrasonic measurements can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. This paper outlines the testing results of this approach applied to the temperature distribution measurements to a waterwall of a 500 MW power-plant utility boiler. The validation results obtained over the prolonged power plant test show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Walton, Kenneth↗

Contribution of the Two Types of Ekman Pumping Induced Eddy Heat Flux to the Total Vertical Eddy Heat Flux

Based on eddy-rich (0.1° horizontal resolution for ocean) Community Earth System Model simulations, we compute the Ekman pumping induced vertical eddy heat flux using two formulations: the classical and the Stern-Ekman pumping. The two mechanisms yield similar patterns in the eddy-induced vertical heat flux, showing strong upward heat flux in ocean frontal regions such as the western boundary current regions. Using the Gulf Stream Extension region as an example, we estimate (1) the Stern-Ekman pumping induced eddy heat flux is 23% and 12% of the total vertical eddy heat flux at 50 m depth during summer and winter, respectively; (2) the classical Ekman pumping accounts for 82% and 88% of the Stern-Ekman pumping induced eddy heat flux at 50 m during summer and winter, respectively. The second finding indicates eddy current feedback on wind stress is the primary cause for the upward eddy heat flux generated by Ekman pumping.

58 GEOSCIENCES↗

Band Heater Heat Flux Characterization Using Inverse Heat Conduction Problem Models

Abstract An experimental apparatus was constructed to correlate water flowrate and temperature rise under an external band heater. Due to the physical characteristics of the band heater, its transient heating behavior is unknown. This paper investigates the application of inverse heat conduction problem (IHCP) methods to characterize the heat flux from the band heater. Three experiments with different heating times (5, 10, and 20 s) and no flowrate were conducted to measure the transient temperature under the 400 W band heater. Type-T thermocouples measure surface temperature at the centerline of the band heater. The experimental results are computed with five different heat conduction models. The models are chosen to identify how the heat flux response varies from a simplified to a realistic model. Additionally, the results of the experimental heat flux are compared to the manufacturer band heater data (58.9 kW/m2) for each model. The minimum time needed for the heater to fully energize the system is from 10 to 12 s. The residuals for each model are analyzed and used to evaluate the appropriateness of the five different models. The results show that the use of simpler models can achieve results similar to those of complex models, with less time and computational cost.

Engineering↗

Boiling peak heat flux for steady inhomogeneous heat transfer in superfluid He 4

Superfluid helium-4 (He II) is a widely adopted coolant in scientific and engineering applications owing to its exceptional heat transfer capabilities. However, boiling can spontaneously occur on a heating surface in He II when the heat flux exceeds a threshold value $q^*$, referred to as the peak heat flux. While the parameter $q^*$ holds paramount importance in the design of He II based cooling systems, extensive research has primarily focused on its behavior in steady homogeneous heat transfer from a flat heating surface. For inhomogeneous heat transfer from curved surfaces, $q^*$ exhibits intricate dependance on parameters such as the He II bath temperature $T_b$, the immersion depth $h$, and the curvature radius $R_0$ of the heating surface. A comprehensive understanding on how $q^*$ depends on these parameters remains elusive. In this paper, we report our systematic study on $q^*$ for steady heat transfer from cylindrical and spherical heaters in He II. We compute $q^*$ for a wide range of parameter combinations $(T_b, h, R_0)$ by solving the He II two-fluid equations of motion. The generated data have allowed us to develop a robust correlation that accurately reproduces $q^*$ for all the parameter combinations we explored. Furthermore, our findings, particularly the establishment of the correlation, carry valuable implications for emergent applications that involve steady inhomogeneous heat transfer in He II systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Mechanisms of heat flux across the Southern Greenland continental shelf in 1/10° and 1/12° ocean/sea ice simulations

The increased presence of warm Atlantic water on the Greenland continental shelf has been connected to the accelerated melting of the Greenland Ice Sheet, particularly in the southwest and southeast shelf regions. Results from two high-resolution coupled ocean-sea ice simulations that utilized either the 1/10-degree Parallel Ocean Program (POP) or the 1/12-degree HYbrid Coordinate Ocean Model (HYCOM) are used to understand the flux of heat on and off the southern Greenland shelf. The analysis reveals that the region of greatest heat flux onto the shelf is southeast Greenland. On the southwestern shelf, heat is mainly exported from the shelf to the interior basins. We identify differences in the shelf break current structure and on-shelf heat content between the two simulations. Just south of the Denmark strait, there is a seasonally persistent pattern of multi-day variability in the cross-shelf heat flux in both simulations. In the POP simulation, this high-frequency signal results in net on-shore heat flux. In the HYCOM simulation, the signal is weaker and results in net off-shelf heat flux. This variability is consistent with Denmark Strait Overflow eddies traveling along the shelf break.

58 GEOSCIENCES↗

3D modeling of n = 1 RMP driven heat fluxes on the SPARC tokamak PFCs using HEAT

3D heat flux calculations at the lower outer divertor plate of SPARC using the HEAT code show that 3D fields generated from error field correction coils can lead to enhanced peak heat fluxes up to 15 times larger compared to the axisymmetric case. Previously employed to simulate axisymmetric heat flux on 3D plasma facing components, the HEAT code can now predict 3D heat flux generated by non-axisymmetric plasmas. This is achieved via a new HEAT module which leverages the 3D field line tracing capabilities of MAFOT starting from an M3D-C1 (MHD resistive code) perturbed equilibria. The resulting heat flux is assigned using the magnetic footprint and the heat flux layer model, an extension of the 2D heat flux model also known as the Eich, to 3D non-axisymmetric plasmas. For SPARC, the new capabilities of HEAT are used to calculate the 3D heat loads resulting from n = 1 perturbation fields (with n indicating the toroidal periodicity) applied through a toroidal array of six picture frame coils with different amplitude. The comparison with the unperturbed case shows significant changes in shape and intensity of the heat flux profile. The results show that the application of n = 1 3D field leads to a localized enhancement of the heat flux peak, influenced by the wetted area impacted by the magnetic footprint, and the appearance of a secondary heat flux peak, whose intensity depends on amplitude of the applied 3D field and toroidal location.

3D heat flux↗

Development and validation of non-axisymmetric heat flux simulations with 3D fields using the HEAT code

A new comprehensive module to simulate heat fluxes from three-dimensional (3D) magnetic fields has been implemented in the HEAT code. Especially compact tokamaks like SPARC require tools to predict and manage large heat fluxes. Existing release versions of HEAT can only simulate axisymmetric heat flux on 3D plasma facing components. The new module uses an M3D-C1 perturbed equilibrium and the MAFOT code to trace field lines of the perturbed 3D magnetic field. Heat flux is then assigned to the resulting footprints via a 3D layer model. The model distinguishes between the scrape-off layer, the magnetic lobes and the private flux region, and employs only 0D parameters like the layer width, diffusive spread and the last closed flux surface position in the perturbed edge to generate a heat flux profile. The magnitude is normalized to the total input power. Resulting heat flux simulations are compared and validated against infrared measurements in the DIII-D tokamak with applied 3D fields; good agreement is found for several cases. The new module can now be applied to the SPARC tokamak; a preliminary result for applied rotating 3D fields is shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Lithium Injection for a Real Time Control of the Divertor Heat Flux for Fusion Devices

When the local heat flux exceeds specified flux limit, tungsten PFC surfaces can be damaged, which is not acceptable for a reliable reactor operations. The divertor PFCs are typically designed for a specific heat flux limit usually assuming an average steady-state heat flux which is typically 5–10 MW/m 2 . However, in addition to steady-state heat flux, fusion reactor divertor PFCs could experience transient heat fluxes such as ELMs and/or other magnetic reconnection events which can deposit large transient heat fluxes onto the divertor PFCs. The transient divertor heat flux could be significantly larger than the steady-state heat flux which could damage the solid PFC surfaces. The divertor heat flux can be subjected to additional complications such as the uncertainties in the the divertor strike point heat flux projection. Moreover, there are additional experimental observations of non-axisymmetric power flux which can occur under non-axisymmetric magnetic perturbations. The liquid lithium (LL) PFCs is more resilient against such transient heat fluxes as they could evaporate LL as needed and the lost LL can be then replenished afterward. In this paper, we analyze a case for a transient divertor heat pulse of 1 MJ in 10 ms for a ITER-size reactor. This is a small perturbation (~ 0.1%) to the expected plasma stored energy compared to the previously analyzed case of 20 MJ heat pulse. Even with this relatively modest heat pulse, the LL surface undergoes ~ 100 °C temperature rise. However, the resulting LL surface heating without rapid cooldown mechanism could lead to excessive LL evaporation continuing well after the transient heat flux resulting in a significant Li injection of ~ 0.6 mol in about a 200 ms period. This amount of Li injection could cause plasma dilution and performance degradation. On the other hand, an active Li injection capability if optimized could prevent the LL surface temperature rise and thus reducing subsequent Li evaporation into the plasma by a factor of 7 compared to the passive LL PFC case. A crucial tool of active Li injection is a rapid response pellet injector which could inject light impurity pellets before the excessive heat flux could reach the divertor plate causing serious damage. A simple pellet ablation model suggests a favorable pellet deposition profile for smaller ~ 0.1 mm radius pellet with ~ 10–20 m/s velocity. Moreover, if it is possible to inject from the private flux region, the pellet injection efficiency into the high heat flux strike point region can be as high as 80% compared to ~ 50% for the injection from outer radius region. The pellet deposition efficiency can be further improved by designing a shell-pellet which can burst when a certain ablation fraction is reached. Finally, a possible implementation technique using an inductive pellet injector with a rapid time response of a few msec is proposed here which can be tested in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The importance of sub-meter-scale snow roughness on conductive heat flux of Arctic sea ice

Abstract The conductive heat flux through the snow and ice is a critical component of the mass and energy budgets in the Arctic sea ice system. We use high horizontal resolution (3–15 cm) measurements of snow topography to explore the impacts of sub-meter-scale snow surface roughness on heat flux as simulated by the Finite Element method. Simulating horizontal heat flux in a variable snow cover modestly increases the total simulated heat flux. With horizontal heat flux, as opposed to simple 1D-vertical heat flux modeling, the simulated heat flux is 10% greater than that for uniform snow with the same mean snow thickness for a 31.5 × 21 m region of sea ice (the largest region we studied). Vertical-only (1D) heat flux simulates just a 6% increase for the same region. However, this is highly dependent on observation resolution. Had we measured the snow cover at 1 m horizontal spacing or greater, simulating horizontal heat flux would not have changed the net heat flux from that simulated with vertical-only heat flux. These findings suggest that measuring and modeling snow roughness at sub-meter horizontal scales may be necessary to accurately represent horizontal heat flux on level Arctic sea ice.

Geology↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Non-linear dependence of ion heat flux on plasma density at the L–H transition of JET NBI-heated deuterium–tritium plasmas

Abstract Recent JET D–T campaigns opened the possibility of unique isotope studies to investigate the L–H transition physics in view of reactor plasmas and to study the origin of the observed power threshold minimum. In the present paper, we characterise L–H transitions in the low and high-density branches of JET NBI-heated D–T plasmas. As discussed in the paper, L–H transition has been hypothesised to be determined by the transport power losses of plasma ions, i.e. the so-called ion heat flux ( Q i ). We present the first power balance analysis of JET NBI-heated D–T plasmas to evaluate the ion heat flux at the transition. Due to the experimental setting being similar to previous JET D experiments, we also directly compare the results, discussing the isotope effect and similarities between datasets. First, we find an isotope effect between D and D–T Q i , with a lower Q i in D–T plasmas. We confirm that the ion heat flux deviates from density linearity compared to the linear trend observed in wave-heated D plasmas of other tokamaks. The deviation we observe in NBI-heated L–H transitions happens at an isotope-dependent density. Plasma edge rotation correlates with Q i deviation from density linearity in the low-density branch. However, further investigations would be required to assess the role of rotation on Q i and the power threshold minimum at JET. At low plasma density, NBI power dominates Q i , while increasing the density makes the equipartition power dominant. We finally compare our results with hypotheses proposed from evidence in other tokamaks to present a complete overview of ion heat flux analyses in D and D–T NBI-heated plasmas at JET.

Vincenzi, P. (ORCID:0000000251564354)↗

Impact of edge harmonic oscillations on the divertor heat flux in NSTX

Previously, ELM-free and inter-ELM divertor peak heat flux reduction induced by an edge harmonic oscillation (EHO) was observed in NSTX (K.F. Gan et al., 2017 Nucl. Fusion 57 126053). This paper introduces new analysis of the EHO impact on the divertor heat flux. It was found that enhanced edge turbulence significantly altered the divertor heat flux footprint in NSTX H-modes, relative to ELM-free discharges. When the background edge fluctuation level was low, the EHO significantly increased the heat flux width and decreased the divertor peak heat flux. When the background edge fluctuation level was high, the EHO actually increased the divertor peak heat flux. As a result, it was also found that the heat flux width increased with increasing frequency of the EHO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strong Red Noise Ocean Forcing on Atlantic Multidecadal Variability Assessed from Surface Heat Flux: Theory and Application

The role of ocean forcing on Atlantic multidecadal variability (AMV) is assessed from the (downward) heat flux–SST relation in the framework of a new stochastic climate theory forced by red noise ocean forcing. Previous studies suggested that atmospheric forcing drives SST variability from monthly to interannual time scales, with a positive heat flux–SST correlation, while heat flux induced by ocean processes can drive SST variability at decadal and longer time scales, with a negative heat flux–SST correlation. Here, first, we develop a theory to show how the sign of heat flux–SST correlation is affected by atmospheric and oceanic forcing with time scale. In particular, a red noise ocean forcing is necessary for the sign reversal of heat flux–SST correlation. Furthermore, this sign reversal can be detected equivalently in three approaches: the low-pass correlation at lag zero, the unfiltered correlation at long (heat flux) lead, and the real part of the heat flux–SST coherence. Second, we develop a new scheme in combination with the theory to assess the magnitude and time scale of the red noise ocean forcing for AMV in the GFDL SPEAR model (Seamless System for Prediction and Earth System Research) and observations. In both the model and observations, the ocean forcing on AMV is in general comparable with the atmospheric forcing, with a 90% probability greater than the atmospheric forcing in observations. In contrast to the white noise atmospheric forcing, the ocean forcing has a persistence time comparable or longer than a year, much longer than the SST persistence of ~3 months. This slow ocean forcing is associated implicitly with slow subsurface ocean dynamics.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Heat Flux Estimates of Seawater Foam for Low Wind Speeds

Laboratory experiments were conducted to measure the heat flux from seafoam continuously generated in natural seawater. Using a control volume technique, heat flux was calculated from foam and foam-free surfaces as a function of ambient humidity (ranged from 40% to 78%), air–water temperature difference (ranged from -9 °C to 0 °C), and wind speed (variable up to 3 m s-1). Water-surface skin temperature was imaged with a calibrated thermal infrared camera, and near-surface temperature profiles in the air, water, and foam were recorded. Net heat flux from foam surfaces increased with increasing wind speed and was shown to be up to four times greater than a foam-free surface. The fraction of the total heat flux due to the latent heat flux was observed for foam to be 0.75, with this value being relatively constant with wind speed. In contrast, for a foam-free surface the fraction of the total heat flux due to the latent heat flux decreased at higher wind speeds. Temperature profiles through foam are linear and have larger gradients, which increased with wind speed, while foam free surfaces show the expected logarithmic profile and show no variation with temperature. The radiometric surface temperatures show that foam is cooler and more variable than a foam-free surface, and bubble-resolving thermal images show that radiometrically transparent bubble caps and burst bubbles reveal warm foam below the cool surface layer, contributing to the enhanced variability.

54 ENVIRONMENTAL SCIENCES↗