Search NASASearch

SEARCH · Search NASA

Results for “Heat Transfer Coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

Cryogenic Flow Boiling in Microgravity: Effects of Reduced Gravity on Two-Phase Fluid Physics and Heat Transfer

With the growing interest in space exploration, cryogenic technologies involving two-phase flow and heat transfer are in high demand to successfully procure advanced space applications such as fuel depots and nuclear thermal propulsion (NTP) systems for deep space missions. However, the unique and extreme thermal properties of cryogenic fluids introduce distinct flow boiling fluid physics and energy transport phenomena, which differ significantly from those observed with conventional fluids. Understanding the unique two-phase physics in cryogenic flow boiling remains an ongoing challenge. Furthermore, the lack of readily available microgravity cryogenic steady-state heat transfer data hinders the assessment of gravitational effects on cryogenic flow boiling. This study aims to elucidate the gravitational effects on two-phase fluid physics and heat transfer by conducting the first-ever experimental measurement of cryogenic flow boiling performance using a steady-state heated method in a reduced gravity environment. Parabolic flight experiments were performed to acquire both heat transfer measurements and high-speed video of interfacial behaviors, under varying gravity levels (microgravity, hypergravity, Lunar gravity, and Martian gravity). The experiments involved flow boiling of liquid nitrogen (LN 2 ) with a near-saturated inlet along a circular heated tube of dimensions 8.5-mm inner diameter and 680-mm heated length. The operating parameters varied are mass velocity of 398.3 - 1342.8 kg/m2s, inlet quality of -0.08 to -0.01, and inlet pressure of 413.68 - 689.48 kPa. Captured microgravity flow patterns range from bubbly to annular, all having vapor structures that are larger than those under higher gravity levels. Under microgravity, absence of buoyancy yields symmetrical vapor structures without flow stratification, laying a physical foundation for the distinct two-phase heat transfer trends during LN 2 flow boiling in microgravity. Transient data collected during the flight parabolas exhibited decreasing heated wall temperature as the aircraft transitioned from hypergravity to microgravity phases. The temperature variation indicated an enhancement in flow boiling heat transfer with decreasing gravity levels and a reduction with increasing gravity levels. The effect of reduced gravity on cryogenic flow boiling heat transfer coefficient (HTC) is discussed based on steady state heat transfer analysis. Seminal HTC correlations are evaluated against the measured microgravity HTC data, of which one is identified for superior accuracy in predicting microgravity data. Finally, a new HTC correlation is proposed to improve accuracy of microgravity predictions, yet there still exists room for further improvement with future terrestrial flow boiling experiments at different flow orientations relative to Earth gravity.

Microgravity

CFD-Assisted Nodal Modeling of Sloshing in a Cryogenic Propellant Tank

During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.

Cryogenic Tank Sloshing

A GPU-based Approach for Turbomachinery Application

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Gas Turbine

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows

Transitional Flow in Thin Tubes for Space Station Freedom Radiator

A two dimensional finite volume method is used to predict the film coefficients in the transitional flow region (laminar or turbulent) for the radiator panel tubes. The code used to perform this analysis is CAST (Computer Aided Simulation of Turbulent Flows). The information gathered from this code is then used to augment a Sinda85 model that predicts overall performance of the radiator. A final comparison is drawn between the results generated with a Sinda85 model using the Sinda85 provided transition region heat transfer correlations and the Sinda85 model using the CAST generated data.

Patrick Loney

Metallurgical and Thermal Properties of 57Ni-40Ti-3Hf (wt%)

Selected properties of 57Ni-40Ti-3Hf (wt%) were measured to further develop this material for use in aerospace rolling-element bearings. The average grain size and microindentation hardness of the material at room temperature were 90 μm and 549 HV, respectively. From room temperature to 500 °C, electrical resistivity increased from 8.9×10–7 to 11.3×10–7 Ω⋅m, thermal expansion coefficients varied from 1.1×10–5 to 1.2×10–5 mm/mm⋅°C, specific heat increased from 0.44 to 0.53 W⋅sec/g⋅K, thermal diffusivity rose from approximately 0.003 to 0.005 cm2/sec and thermal conductivity increased from approximately 0.09 to 0.19 W/cm⋅K. The behavior of the material can be explained by well-known metallurgical theory. These results are expected to provide a basis for design and modeling of future aerospace components.

rule of mixtures

Decoupling Surface Topography from Gravitational Acceleration in Cryogenic Pool Boiling

Boiling heat transfer is governed by a complex interplay between surface conditions and gravitational acceleration. To isolate the sole effects of gravity, we investigated the pool boiling characteristics of liquid nitrogen on atomically smooth silicon dioxide (SiO 2 ) surfaces under terrestrial (1-g) and reduced gravity (0±0.02 g) conditions achieved via parabolic flight. Our results quantify a drastic reduction in the critical heat flux (CHF) in reduced gravity, decreasing from 16.15 W/cm 2 at 1-g to 5−6 W/cm 2 at μ-g due to the suppression of buoyancy. Conversely, we observed a distinct increase in the heat transfer coefficient (HTC) in the reduced gravity condition prior to CHF. By utilizing a surface with a maximum peak-to-valley height of ≈36.7 nm and low contact angle hysteresis (<10°), we confirm this HTC enhancement is an intrinsic response to the gravitational environment, decoupled from surface-defect-induced nucleation. These findings demonstrate that the influence of surface topography is significantly more prominent in reduced gravity than in terrestrial conditions, providing a critical baseline for rationalizing the design of cryogenic thermal management systems in space and quantum applications.

Liquid nitrogen

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

two-phase flow

Aerothermal Shape Optimization of Actively-Cooled Battery Packs Using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

heat transfer

Aerothermal Shape Optimization of Actively-Cooled Battery Packs using Conjugate Heat Transfer

Thermal management for battery is important for electric aircraft because battery temperature is critically important to vehicle safety, and it also has direct impact on the efficiency of the battery system. Because ambient air is a readily available resource for aircraft, this paper considers an active cooling concept with forced convection of ambient air through the battery pack. Conjugate heat transfer analysis is used to solve the coupled aero-thermal problem, which consists of a finite-volume computational fluid dynamics solver for the fluid domain, and a conduction heat transfer solver for the solid domain. A mixed Neumann and Dirichlet boundary condition is developed for the fluid-solid interface, which allows the solid domain to completely submerge in the fluid domain. A gradient-based optimization method is adopted, and the discrete adjoint approach implemented in DAFoam is used to efficiently compute the gradients. The aero-thermal coupling for primal analysis and gradient computation is handled using the OpenMDAO-based MPhys framework. A constant heat source is prescribed for the battery cells, and the battery shape (design variable) is optimized to minimize cooling pump power and battery weight (composite objective function) while keeping the battery temperature below a threshold (constraint). The optimized design achieves a 44.6% and 1.5% reduction in the cooling pump power and battery weight, respectively, and the maximal temperature constraint is satisfied. This work has the potential to reduce battery-pack weight, improve performance, and reduce the weight of thermal management systems for electric vertical take-off and landing aircraft.

thermal management

A Modular Conjugate Heat Transfer Optimization Framework for Thermal Management of Electric Aircraft

Conjugate heat transfer (CHT) analysis and optimization is a powerful method for improving thermal management, as it simultaneously resolves the temperature distribution in both fluid and solid domains. This paper presents a modular, discrete adjoint-based CHT optimization capability integrated within the OpenMDAO/MPhys framework. A unique feature of the proposed framework is its flexibility to extend to multidisciplinary optimization, including aero-structural-thermal applications. The fluid domain is modeled using a finite-volume Computational Fluid Dynamics (CFD) solver, and the solid domain with a conduction heat transfer solver. A mixed Neumann-Dirichlet boundary condition is developed to enable full submersion of the solid geometry within the fluid domain, while ensuring consistent temperature and heat flux coupling at the CHT interface. Gradient-based optimization is performed; the gradients are efficiently computed using the discrete adjoint solvers implemented in DAFoam. To demonstrate the method, this paper considers two cases related to electric aircraft thermal management: a U-bend heat exchanger and an actively cooled battery pack. The U-bend case aims to minimize pressure loss while maximizing heat flux by changing the pipe geometry. The optimized design reduces pressure loss by 52.7% and increases total heat flux by 2.3%. In the battery pack case, a 3-by-3 cell configuration is cooled by ambient airflow, with constant heat generation prescribed in the cells. The battery casing shape serves as the design variable, and the objective function is a weighted sum of pressure loss and pack weight, subject to a maximum temperature constraint. The optimized design achieves a 44.6% reduction in pressure loss and a 1.5% reduction in weight, while satisfying the thermal constraint. To ensure the reliability of the optimized designs, this study validates coarse-mesh, steady-state predictions against fine-mesh unsteady simulations, demonstrating consistency within acceptable errors. This work demonstrates the potential of the developed framework to enable rapid, high-fidelity design of thermal management systems for electric aircraft.

heat transfer

Cryogenic Spray Quenching of A Simulated Propellant Storage Tank Wall With Heat Transfer Enhancement By A Thin-Film Coating and Flow Pulsing in Microgravity

Human space exploration to the Moon, Mars, and possibly asteroids is NASA’s biggest challenge for the new millennium. One of the critical elements to this mission is the effective, sufficient, and reliable supply of cryogenic propellant fluids. Future lower-earth-orbiting (LEO) propellant fuel depots and human-carrying orbital transfer spacecraft flying to the moon and Mars will have to utilize the high thrust and high efficiency of liquid cryogenic chemical propulsion or nuclear thermal propulsion. Efficient in-space tank-to-tank propellant transfer (propellant fuel depot to orbital transfer spacecraft) of cryogenic propellants is an enabling technology for the planned Crewed Mars Surface Mission. The transfer of cryogenic propellants in space, however, has yet to be accomplished, solely due to the unavailability of cryogenic quenching heat transfer data during chilldown (quenching) and filling of the propellant receiver tank in reduced gravity and microgravity as liquid propellant cannot be stored in a required liquid state until the tank is quenched down to the liquid temperature. Therefore, highly energy efficient thermal-fluid management breakthrough concepts to conserve and minimize the cryogen consumption during propellant transfer have become the focus of research and engineering development, especially for the deep-space mission to Mars. In this paper, we introduce such concepts and demonstrate their feasibility for cryogenic storage tank chilldown in parabolic flights under a simulated space microgravity condition. In order to maximize the storage tank chilldown efficiency for the least amount of cryogen consumption, the technology adopted included cryogenic spray cooling, Teflon thin-film coating of the simulated tank surface, and spray flow pulsing. The completed flight experiments successfully demonstrated that spray cooling is the most efficient cooling method for the tank chilldown in microgravity. In microgravity, Teflon coating alone can improve the efficiency up to 72% and the efficiency can be improved up to 59% by flow pulsing alone. However, Teflon coating together with flow pulsing was found to substantially enhance the chilldown efficiency in microgravity for up to 113%.

spray

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit