Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Pathways of clean energy heating electrification programs for reducing carbon emissions in Northwest China

We report clean energy heating electrification programs provide a promising way to reduce carbon emissions from fossil fuel combustion and consumption. This work studies the cost competitiveness of clean energy heating technologies under three dynamic mechanisms: investment costs, subsidy policies, and operating costs with real data. It provides key insights into the cost competitiveness of the different heating technologies deployed in different areas, as well as their sensitivity to the three dynamic mechanisms. The results show that currently, the distinct heating programs are more cost-efficient in the urban area with existing heating networks. The average payback period of all district clean energy heating programs in the urban area is 14.9 years, while that of the individual clean heating programs is 24.7 years. The individual heating programs are becoming increasingly cost-competitive with the incentive mechanisms, especially the electricity pricing mechanisms. Moreover, individual heating technologies present remarkable advantages on flexibility and sustainability in the long run. According to the technology diffusion model proposed in this paper, the individual clean heating programs will occupy more than 50% of the market share in 2050 under the comprehensive effect of CAPEX, government subsidies, and OPEX. The real-world results and analysis render references to shape the pathway of clean energy heating electrification in Northwest China and other regions with a similar situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗

Hydrogel-Salt Hydrate Composite for Highly Stable Heat Energy Storage with Reduced Supercooling

Phase change materials (PCM) have potential for use in thermal energy storage in buildings, medical devices, and water heat pumps. Sodium sulfate hydrate (SSD) is appealing due to its high energy storage capability and affordability. However, SSD has issues including high supercooling (> 15°C) and low thermal cyclic stability. In this study, we introduced an ionic molecular nucleating agent that decreases the supercooling temperature to under 2°C. When this SSD was combined with a hydrogel, it maintained its thermal energy storage capacity for over 100 cycles without any decline. The success is attributed to the polymer confining the SSD crystals, preventing large-scale phase separation and the nucleating agent which resulted in nucleation of many small SSD crystals at small undercoolings rather than a small number of larger crystals. As a proof-of-application, we synthesized this composite at a kg scale and demonstrated its properties in a close to real-world demonstration.

chemical composition, thermodynamics↗

Corrosion evaluation of metal foams in eutectic molten salts for high temperature latent heat energy storage application

High-temperature Thermal Energy Storage (TES) has drawn great attention as a technology that can increase the role and profitability of micro nuclear reactors in the decentralized clean energy market. Various research needs have been proposed by Idaho National Laboratory (INL) in "the Integrated Energy Systems: 2020 Roadmap" with the goal of utilizing the high temperature of 550 degrees or more generated in the 4th generation reactor to industrial purposes from the standpoint of integrated energy systems [1]. With the recent development of the 4th generation nuclear power plant, including micro nuclear reactor, there is a great deal of interest in researching how to efficiently couple a heat source to an industrial process through thermal processing. Texas A&M University (TAMU) and INL are currently collaborating to develop a novel latent heat storage design called HITB (Heat pipe-Integrated Thermal Battery). As part of the small-scale experimental demonstration research for HITB, a study for storage medium selection was conducted at TAMU. Eutectic salts have attracted interest as high-temperature heat storage medium for HITB. Especially, chloride molten salts and fluoride molten salts are considered promising candidates due to their high melting temperature, thermal stability, and high latent heat of fusion. Since eutectic salts have poor thermal conductivity in general, it is critical to distribute materials with high thermal conductivity evenly to facilitate the charging and discharging of heat. In this study, metal foam was considered in the HITB system to overcome the poor heat transfer characteristics of eutectic salts. In order to improve heat transfer, it is necessary to study materials with high thermal conductivity, corrosion resistant to molten salts, such as fins, extended surfaces, particles, microcapsulation, or foam structure. Porous structure of copper or aluminum can increase heat transfer area, form a thermal transfer network, and increase the effective thermal conductivity of thermal storage medium [2]. Since the melting temperature is required to be at least 450? in the current HITB design, various eutectic salts are being considered. FLiNaK and FLiBe, which are famous for fluoride salts, are good candidates, but due to the sharp rise in the price of LiF recently, they are excluded for economic reasons to be applied to large-capacity thermal energy storage. On the other hand, chloride salts are very cheap and easy to obtain, have a high melting temperature, and have a high latent heat of fusion, so they are recently in the spotlight as a phase change material. However, because of the hygroscopic nature of chloride salts, HCl gas due to impurity is easy to be released and is particularly vulnerable to corrosion. Chloride eutectic salts have been tested and suggested for metal alloys that are particularly resistant to corrosion, such as SS304, SS316, Hastelloy, Inconel 625, Incoloy 800H, which has low thermal conductivity, and is very expensive [3-6]. Porous materials with high thermal conductivity such as copper and aluminum have been tested for stability in fluids such as paraffin or water as metal foam or metal fin structures, but high temperature corrosion tests were not performed on various eutectic salts yet. Therefore, this study investigated the high temperature corrosion characteristics of metal alloys, such as C10100 foam, C10100 plate, 6101 alloy foam, and SS316 plate, while immersed in the candidate eutectic salts. A total of 20 tests for SS316 coupons and 10 tests for C10100 coupons were performed to ensure the repeatability of the present measurements. Since it is difficult to completely remove the salt inside metal foam due to the complex inner structure of the metal foam, only the surface condition was observed with a microscopy and scanning electron microscopy (SEM) image, except for measuring the corrosion rate and average mass loss.

25 ENERGY STORAGE↗

Characterization of Inlet Guide Vane Performance for Discharge Compressor Operation near the Dome of an sCO 2 Pumped Heat Energy Storage

Southwest Research Institute® (SwRI®) developed and tested a Variable Inlet Guide Vane (IGV herein) assembly on an integrally-geared sCO 2 compressor (IGC) to demonstrate compressor operation at both the compressor design point and near the dome and to define the operating limits of the compressor by monitoring for two-phase flow, flow turbulence from the IGVs, and compressor choke and surge as the CO 2 inlet temperature is varied. Performance testing was conducted on an existing integrally-geared, two-stage main compressor designed for near-critical-point operation with CO 2 . This testing campaign validated the IGV design and operation, as well as improved the understanding and confidence in operating compressors and predicting performance characteristics near the critical point where fluid properties change rapidly with temperature. In addition to improving the robust operating limits of an sCO 2 compressor, the development of an IGV for the IGC system improved off-design compressor efficiency by 12%.

25 ENERGY STORAGE↗

Heat exchanger(s) for recovering water and/or heat energy from turbine engine combustion products

A turbine engine is provided that includes a fan section, a turbine engine core and a recovery system. The turbine engine core is configured to power the fan section. The turbine engine core includes a core compressor section, a core combustor section and a core turbine section. A centerline axis of the turbine engine core is offset from a centerline axis of the turbine engine. The recovery system includes an evaporator module and a condenser module. A core flowpath extends sequentially through the core compressor section, the core combustor section, the core turbine section, the evaporator module and the condenser module from an inlet into the core flowpath to an exhaust from the core flowpath.

Sobanski, Jon E.↗

Development of an Integrated Thermal Energy Storage Heat Exchanger for Concentrating Solar Power

In this design and development effort a latent-heat energy storage heat exchanger was designed for a 10MW e sCO 2 power plant as a basis for detailed design and testing of a new phase-change heat exchanger technology. High efficiency thermal conductors of graphite foam or folded copper were employed within chloride salt phase-change volumes bounded by alternating high density compact plate-fin heat exchange cells in this new heat exchanger technology. Test articles were constructed at Brayton Energy and tested at Argonne National Laboratory. Copper-conducting samples were constructed and tested at Brayton Energy.

14 SOLAR ENERGY↗

MODEL DEVELOPMENT AND VERIFICATION OF A 1,350°C AIR RECEIVER TEST SYSTEM

Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multicycle power plants. A novel additively manufactured (AM) silicon carbide (SiC), ceramic matrix composite (CMC) volumetric receiver was developed that consisted of a lattice structure, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous receiver was transferred to heated ambient air. The receiver acted as a convective heat exchanger, transferring heat to the fluid through convection. Engineering was facilitated to develop a high-temperature air receiver test bed at Sandia national Laboratories (SNL) capable of demonstrating a 50kWth open-loop volumetric SiC air receiver module developed by General Electric Aerospace Research (GE Aerospace). This paper presents the development of the high temperature AM SiC-CMC air receiver, the test bed, and the first testing operations of this device, which was experimentally demonstrated to achieve 1,350°C for over 3.5 hours of operation, based on input flux levels of 67–91 W/cm2 0.5-2.5 kg/s flow rates. From the test campaign results, based on the measured convective heat transfer to the airflow and bounded radiative-loss assumptions, the solar-thermal efficiency of HOTSSTAR test module was estimated to be approximately as high as 74% for representative test conditions.

14 SOLAR ENERGY↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska, set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is energy-efficient home heating technologies such as ductless air- source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined together to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 other energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs, which will help inform future heat pump deployment efforts in the area.

air source heat pump↗

Ductless Heat Pump Energy Monitoring in a Cold Climate

In 2018, the City and Borough of Juneau, Alaska set the goal of reaching 80% renewable energy for heating and transportation by 2045. An important factor to help reach this goal is finding energy efficiency home heating technologies such as ductless air source heat pumps (DHPs), which rely on the local hydropower electric grid to provide space heating for an entire home or a main living area. To help residents reduce energy costs and move toward the community renewable energy goal, a team of local, state, and national partners joined to run Thermalize Juneau 2021, an energy campaign that provided education, a simplified installation process, and a bulk purchase discount. Overall, the campaign enrolled 165 participants, resulting in 75 DHP installations and over 30 energy efficiency improvements. To evaluate the reliability and energy use of the DHPs installed during the Thermalize Juneau campaign, researchers installed energy monitors on heat pumps of 14 participants and conducted interviews with homeowners. Data from two heating seasons (2021-2022 and 2022-2023) has allowed researchers to examine the accuracy of pre-campaign energy savings predictions, establish energy savings for a small group of households, and provide insights on the energy use and occupant satisfaction of DHPs which will help to inform future heat pump deployment efforts in the area.

air source heat pump↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

A buffering heat exchanger/thermal energy storage system for desalination applications

A buffering heat exchanger/thermal energy storage (BHXTES) system was designed using a fast-response phase-change material/graphite foam (PCM/GF) medium for desalination and potentially other industrial applications. Unlike a store-now-and-use-later TES system, this study focused on developing a dynamically balanced, continuously used, system that optimized three functions. A lab-scale prototype was designed and fabricated with a PureTemp 151/GF storage medium. The experimental data showed excellent thermal performance repeatability indicating minimal effects of PCM expansion and contraction on the GF as well as negligible PCM redistribution effects. The experimental data also served as a validation of the numerical model of the BHXTES system, after which optimization of the BHXTES system was conducted through numerical simulations for both PureTemp 151/GF and solar salt/GF as the storage medium. The results show that, with a Therminol 55 heat transfer fluid, continuous operation of the system can be realized with a solar energy source through cycles of 8-h changing for desalination and energy storage with the supplied heat followed by 16-h discharging for desalination with the stored energy. As a result, the working fluid outlet temperatures are generally in the ranges of approximately 128–160 °C for a PureTemp 151/GF medium and 198–220 °C for a solar salt/GF medium.

Buffering↗