SEARCH · Search NASA
Results for “Heat exchanger fouling”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery
This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.
Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope
Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.
Flow assisted anti-fouling geometries for compact heat exchangers
A header for a heat exchanger and method for cleaning a heat exchanger in a loop without disconnecting loop components is provided. The header is in flow communication with the heat exchanger for distributing fluid through a plurality of adjacent channels. The header is connected between a main heat exchanger inlet nozzle and a channel flow distributor. A filter element is disposed within the header between the nozzle and channel flow distributor. Under normal operation, the filter element removes particulates and fouling material from the main flow stream before it enters the heat exchanger channels. During the cleaning process, fluid is injected on or through the filter element to remove particulates and fouling material through at least one outlet port. The header arrangement allows the filter element to be ‘cleaned in place’ without draining the system and disconnecting the heat exchanger or other components from the flow loop.
Fouling modeling and prediction approach for heat exchangers using deep learning
In this article, we develop a generalized and scalable statistical model for accurate prediction of fouling resistance using commonly measured parameters of industrial heat exchangers. This prediction model is based on deep learning where a scalable algorithmic architecture learns non-linear functional relationships between a set of target and predictor variables from large number of training samples. Here, the efficacy of this modeling approach is demonstrated for predicting fouling in an analytically modeled cross-flow heat exchanger, designed for waste heat recovery from flue-gas using room temperature water. The performance results of the trained models demonstrate that the mean absolute prediction errors are under 10 –4 KW –1 for flue-gas side, water side and overall fouling resistances. The coefficients of determination (R 2 ), which characterize the goodness of fit between the predictions and observed data, are over 99%. Even under varying levels of measurement noise in the inputs, we demonstrate that predictions over an ensemble of multiple neural networks achieves better accuracy and robustness to noise. We find that the proposed deep-learning fouling prediction framework learns to follow heat exchanger flow and heat transfer physics, which we confirm using locally interpretable model agnostic explanations around randomly selected operating points. Overall, we provide a robust algorithmic framework for fouling prediction that can be generalized and scaled to various types of industrial heat exchangers.
The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study
Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.
Advanced Anti-Fouling Coatings to Improve the Efficiency of Coal Power Plants
As the total cost of carbon to generate energy has become a global concern, operators are increasingly looking at all parts of the generation cycle to find areas where efficiency gains may be found. It has been long identified that fouling of heat exchangers is a persistent cause of up to 2.5% of global CO 2 emissions. Unfortunately, practice has also demonstrated that unless a powerful economic driver exists to encourage preemptive mitigation of fouling, there will always be a strong tendency for operators to minimize any form of intervention due to high costs and challenges in scheduling downtime. The objective of this proposed research effort was to demonstrate how existing power plants could lower their carbon emissions and significantly improve heat transfer efficiency using new surface treatment materials to control fouling in a variety of heat exchange equipment. The surface treatment material which was optimized and deployed in this effort is now known commercially as HeatX. It is a low-surface energy, water- and oil-repellent, abrasion resistant material which can be applied in-situ to a wide variety of previously worn/used/in-service substrates. Once applied, it provides a barrier against corrosion, scale deposit formation, and biofilm adhesion on the circulating water-containing tube-side. Alternatively, if applied to the tube exterior, the non-wetting nature of the surface was demonstrated to promote dropwise condensation, subsequently lowering condenser backpressure and increasing overall plant efficiency. As part of this cooperative effort, the Department of Energy’s support was crucial to de-risk and demonstrate the concept of HeatX, while validating both the performance and economic benefit in multiple pilot field studies. The HeatX material properties were optimized in this effort for full field applicability to heat exchangers and condensers, and Oceanit developed the necessary procedures and protocols to provide enough material to support extended length, multi-year demonstrations in the power generation, desalination, and refining industries, making this technology broadly applicable and ready for commercial transition. Field deployment case studies at thermal power plants have shown that the HeatX treatment can provide economic savings of up to $15,000 per day for an operator based on avoiding maintenance costs and lowering fuel usage. The complete mitigation of fouling effects can increase the efficiency of equipment by up to 7%, in a field where gains of 0.5% are generally seen as operationally significant. The HeatX treatment has also demonstrated exceptional lifetime and compatibility with a wide variety of seawater and hydrocarbon environments, further increasing both the return on investment and the effective emission reduction. Such efficiency improvements correlate to massive carbon savings. For every 1 GW of capacity, operators can see carbon emissions reductions of 300,000 tons of CO 2 per year. When looking at the bigger picture, improved condenser function across the U.S. has the potential to prevent 221.3 million tons of CO 2 emissions, equivalent to the sequestration capacity of 129 million acres of forest. If applied on a global scale, 1.26 billion metric tons of CO 2 could be averted from the atmosphere, the same amount of carbon sequestrated by 1.5 billion acres of forest annually or 262,000 wind turbines operating annually. As businesses across multiple industries take a more active role in focusing on environmental, social, and governance (ESG) solutions as part of their core business operations, HeatX will be an attractive technology for commercial investment.
Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling
Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.
Experimental Investigation of Polymer-Induced Fouling of Heater Tubes in the First-Ever Polymer Flood on Alaska North Slope Part II
A polymer flood pilot has been ongoing in the Schrader Bluff viscous oil reservoir at Milne Point on the Alaska North Slope. The results from the pilot are encouraging. However, a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This work applies a multiexperimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids to determine safe operating conditions. Dynamic scale loop (DSL) tests were conducted to study fouling due to polymer at different skin temperatures (165–350°F) in a dynamic state of fluid flow where the fluids’ flow mimics the residence time of fluids in the heat exchanger of the field pilot. Static deposit tests were also conducted at similar skin temperatures of 165–250°F using a novel experimental apparatus designed and built in-house. It was found that at higher skin temperatures of 250–350°F, tube blocking was observed in the DSL tests, whereas the tests at 165–200°F did not show any tube blocking, even in a more extended test period. The deposit test showed that the deposit rate generally increases with skin temperature, and the presence of polymer aggravates the fouling. The copper tube performs best when the skin temperatures are 165–200°F, while the stainless steel tube performs best at a skin temperature of 250°F. These experiments also manifested the influence of the cloudpoint of the solution as the deposit rate increased significantly when the skin temperature was higher than the solution cloudpoint. The study provides a source of practical guidance to the field operations.
System with a direct contact desublimating heat exchanger and temperature regulation
A process to prevent fouling using a desublimating heat exchanger is disclosed. An outlet stream from the desublimating heat exchanger may be split into a plurality of parallel streams. The parallel streams may be sent through a plurality of discrete unit operations, and the unit operations may change the temperature of at least one of the parallel streams. Parallel streams of differing temperature may emerge from the unit operations. The parallel streams which are of a similar temperature may be mixed to form a warm stream and a cool stream. The warm stream and the cool stream may be sent to a mixing chamber. A mixed stream of substantially uniform temperature may emerge from the mixing chamber, and the mixed stream may be recycled back to the desublimating heat exchanger. The mixing chamber may be separate from the desublimating heat exchanger, or the parallel streams of differing temperature may be mixed in the desublimating heat exchanger.
Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-ever Polymer Flood Pilot on Alaska North Slope
Polymer flooding has been validated in the lab and by successful applications in other countries, such as Canada and China, to be an effective EOR technique for heavy oil reservoirs. Currently, polymer flooding is being pilot tested for the first time in the Schrader Bluff viscous oil reservoir at Milne Point field on Alaska North Slope (ANS). One of the major concerns of the operator is the impact of polymer on the oil production system after polymer breakthrough, especially the polymer induced fouling issues in the heat exchanger. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. A unique experimental set-up was indigenously designed and developed to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Under each test condition, the test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution were heated from 77°F to 122°F to mimic field operating conditions. The heating time and fouling amount were recorded for each run. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It has been found that, in general, the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless steel surfaces at all tested skin temperatures (165°F, 250 °F and 350°F), but only higher skin temperatures of 250°F and 350°F could cause polymer induced fouling issues on the copper tube surface and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer induced fouling would not occur and only mineral scale deposited, but above which the polymer would obviously aggravate the fouling issue. The heating efficiency of the tube would be reduced gradually as more fouling material accumulates on its surface. The ESEM results indicate that if polymer precipitated and deposited on the surface, it would bond to the mineral crystals to form a stronger three- dimensional network structure, and that is why the polymer induced fouling was tougher and more difficult to be removed from the tube surface. The XRD analysis results confirm that the presence of polymer in the fluids can enhance the mineral scale propensity. Overall, the study results have provided practical guidance to the field operator for the ongoing polymer flooding pilot test on ANS. This study may also prove to be valuable for other chemical EOR projects around the world.
Investigation of fouling mechanisms for diesel engine exhaust heat recovery
The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.
Capabilities Development at the University of Texas at El Paso for Hydrogen Generation Research and Education
Gasification-based systems have recently received much attention due to their capability of converting wastes into useful fuels. The gasification of biomass, municipal solid waste (MSW), plastics, and other sustainable resources has shown promise in hydrogen production. When coupled to a CCU or CCS unit, these systems have the potential to achieve carbon neutrality or carbon-negative emissions. In addition, these systems have an edge over conventional incineration or landfill systems by reducing greenhouse gas emissions and recovering useful energy. However, the gasification of MSW and other wastes is still in its early stages. In particular, co-gasification of wastes with biomass has significant unknowns in optimizing the reaction kinetics, operability, design and performance improvements. Currently, Supercritical Water Gasifiers (SCWG) and Plasma Gasifiers are the major systems that are capable of producing high hydrogen amounts from Biomass and MSW, respectively. However, both systems have high capital and operating costs, adversely affecting efficiency and the hydrogen production cost. Additionally, due to lower temperatures, SCWGs are prone to tar formation and fouling in the heat exchangers. Hence, there is a need to look for alternative solutions for MSW and biomass gasifications, particularly in co-gasification. The current effort aims to develop a strategic plan to establish a sustainable gasification facility for hydrogen research at the University of Texas at El (UTEP). A major part of this effort involves an extensive literature survey to identify technological gaps and potential areas of interest. Several concepts were developed in accordance with the current demands from the literature survey. Based on the concepts, a center-wide capability assessment was conducted to measure the current capacity and feasibility of establishing hydrogen research. Afterward, a strategic research plan was developed, and a list of required resources was made for the expansion of hydrogen research at UTEP. In addition, successful partnerships with the local county and the city were developed to pursue hydrogen research. The strategic goal setting and planning of UTEP Aerospace Center resulted in securing $2.5 million in external support to expand the hydrogen research during the project performance period. In addition, during the project period, a course in Hydrogen Energy Systems was developed to expand the energy curriculum at the UTEP Aerospace and Mechanical Engineering Department. The course focused on hydrogen production, storage, supply and delivery and application. The cross-listed course was offered at both undergraduate and graduate levels during the Spring 2024 semester and had 27 enrolled students. Moreover, the students supported under this award were trained in gasification process modeling, CAD, CFD and FEA during the project period. The training enabled the students to move into new projects to support gasification design, integrated gasification combined cycle process plant analysis, gasifier structural and operational analysis, and digitally threading the systems.
PERFORMANCE ANALYSIS OF AN ENGINEERING SCALE HYDROTHERMAL LIQUEFACTION SYSTEM
This work evaluates the Modular Hydrothermal Liquefaction System (MHTLS), an engineering-scale, integrated continuous HTL plant operated at the Pacific Northwest National Laboratory (PNNL), for converting realistic wet wastes into energy-dense biocrudes. The production campaigns discussed here processed algae, sewage sludges, lignocellulosic blends, Industrial food waste, and engineered food-waste slurries at 350?°C and around 200?bar, with nominal feed rates of ~12?L?h?¹. We report biocrude yields and composition, establish mass and elemental (C, N) balances, and quantify energy performance via heater duties, heat-exchanger behavior, and system-level efficiencies. Biocrudes contained 76–80?wt?% C (dry, ash-free) with HHVs of 38-41?MJ?kg?¹, substantially higher than feed materials HHVs of 16.6–26.1?MJ?kg?¹ and approaching petroleum fuels. Dry, ash-free biocrude yields of 32–53?wt?% corresponded to 43–71?wt?% carbon yields, with 18–40?wt?% of feed carbon routed to the aqueous phase. Thermal efficiencies were 50-65%, and total energy efficiencies, including reactor heat input, were 35-55%. A counter-current tube-in-tube heat exchanger delivered U values of 200–450?W?m?²?K?¹, with fouling-induced declines impacting heat recovery and heater duty. The analysis highlights three priorities for the process intensification of HTL: robust, fouling-resistant heat recovery, hydrodynamically suitable reactor and heat-exchanger designs, simplified and predictable solids management, and biocrude-water separation.
Joining Study for Formed Plate Heat Exchangers (CRADA Final Report)
Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.
Joining Study for Formed Plate Heat Exchangers (Final Report)
Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.
Solvent-driven aqueous separations for hypersaline brine concentration and resource recovery
Solvent-driven separation processes can extract water and high-value minerals from high salinity or contaminated brines, simultaneously reducing the environmental impact of brine disposal and enabling resource recovery. The efficient dewatering of hypersaline brines is essential for the sustainable minimal and zero liquid discharge processing of industrial wastewaters. Fractional crystallization can selectively extract ions from contaminated waste streams, allowing critical materials to be recycled, including transition and lanthanide metals required for renewable energy generation and storage. Mass transfer in solvent-driven water extraction occurs across a liquid–liquid interface, eliminating the scaling and fouling of membrane and heat exchanger surfaces and limiting the need for extensive pretreatment. Solvent-driven fractional crystallization can leverage sequential treatment and control of process conditions to rapidly recover salts without requiring evaporation of water. Despite promising applications, the principles and potential of solvent-driven aqueous separations remain poorly understood. This critical review explores the opportunities presented by solvent-based aqueous separations from the molecular to process scale, evaluating the chemistry of solvation and system design in the broader context of desalination, resource recovery, water softening, and mineral production.