Application of a Novel Heat Pump Model for Estimating Economic Viability and Barriers of Heat Pumps in Dairy Applications in the United States

Heat pumps represent an important opportunity for energy savings and decarbonization. This work investigates the techno-economic performance of high-temperature heat pumps (HTHPs) for use in the U.S. dairy industry. The studied heat pump performs a 50 °C temperature lift on a waste heat stream of cleaning water and applies the upgraded heat stream to a fluid milk pasteurization process. This work involved the creation of a HTHP model that estimated the coefficient of performance (COP), internal rate of return (IRR), net present value (NPV), and payback period (PBP), and emissions saved for a heat pump replacing a natural gas boiler. Capital costs, operations, and maintenance (O&M) cost, heat pump lifetime, electricity prices, natural gas prices, and a cost of carbon were varied to perform a parametric study on the factors affecting the break-even price of HTHPs. The results show that HTHP economics are highly sensitive to COP and energy price environment, and less sensitive to capital and O&M cost variance, leading to a large scatter of positive and negative NPVs based on U.S. location. PBPs demonstrate a defined threshold, based on energy price environment, below which favorable two-to-three-year PBPs predominate. This work is focused on the U.S. dairy industry, but international application in relation to fossil vs. electricity price regimes. Heat pumps have seen wider adoption in regions with a high ratio of fossil energy to electricity prices ($/MMBTU vs. $/kWh). The U.S. has plentiful natural gas resulting in lower fossil energy prices which has reduced heat pump adoption. This paper identifies potential first mover industries for HTHP adoption and their associated price regimes even in regions with lower ratios of fossil energy to electricity prices that exist many places globally.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

EnergyPlus Air Source Integrated Heat Pump Model

This report summarizes the development of the EnergyPlus air-source integrated heat pump model. It introduces its physics, sub-models, working modes, and control logic. In addition, inputs and outputs of the new model are described, and input data file (IDF) examples are given.

42 ENGINEERING↗

Improving Air-Conditioner and Heat Pump Modeling (Presentation made at the Building America Stakeholders Meeting) [Slides]

A new approach to modeling residential air conditioners and heat pumps allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted 'behind-the-scenes' without negatively impacting the reliability of energy simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Temperature Heat Pump Model Documentation and Case Studies

High temperature heat pumps (HTHPs) have the potential to serve two valuable functions in the U.S. industry. First, by valorizing and elevating waste heat streams, HTHPs can improve industrial energy efficiency. Second, by electrifying process heat generation, HTHPs can replace combustion technologies with less carbon-intensive sources of energy and reduce industrial greenhouse gas emissions. In certain applications, the combination of increased efficiency, cost savings, and emissions reduction makes HTHPs a promising component of strategies for industrial electrification and clean energy transition. Researchers at NREL have developed a HTHP model. This model has both a physics-based performance estimation component and an economic evaluation component designed to demonstrate the potential economic competitiveness of HTHPs. This document has three main sections. First, an overview of HTHPs is provided as a literature review of relevant information to provide the reader with state-of-the-art information. Second, a description of the HTHP model is provided along with detailed instructions about how to use the model. Third, case studies are provided to showcase the deployment of the HTHP model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Air-Conditioner and Heat Pump Modeling [Slides]

This presentation describes a new approach to modeling residential air conditioners and heat pumps, which allows users to model systems by specifying only the more readily-available SEER/EER/HSPF-type metrics. Manufacturer data was used to generate full sets of model inputs for over 450 heat pumps and air conditioners. A sensitivity analysis identified which inputs can be safely defaulted “behind-the-scenes” without negatively impacting the reliability of energy simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extending ORNL HPDM Capabilities for Design and Optimization of New Refrigerant Blends – FY19 1st Quarterly Milestone Report: Development of Heat Pump System Models (Space Heating) for HFO Blends

We recently published numerous heat pump system models at the HPDM website, in the category of “Space Heating”. The published system configurations include single-stage heat pumps using TXV for expansion or a short-tube fixed-orifice coupled with a suction line accumulator, a two-stage heat pump system putting two compressors in series, single state heat pump using two parallel compressors (tandem), vapor injection systems with a vapor injection compressor coupled with an intermediate economizer or a flash tank. These configurations should cover all the residential heat pump products on the market. Additionally, to accelerate the refrigerant transition and make thousands of existing compressor maps reusable by the new refrigerants, ORNL created a mathematical approach to scale typical vapor injection compressor maps, developed from one baseline refrigerant to be used by the new HFO refrigerants/blends.

42 ENGINEERING↗

Computer Modeling VRF Heat Pumps in Commercial Buildings using EnergyPlus

Variable Refrigerant Flow (VRF) heat pumps are increasingly used in commercial buildings in the United States. Monitored energy use of field installations have shown, in some cases, savings exceeding 30% compared to conventional heating, ventilating, and air-conditioning (HVAC) systems. A simulation study was conducted to identify the installation or operational characteristics that lead to energy savings for VRF systems. The study used the Department of Energy EnergyPlus? building simulation software and four reference building models. Computer simulations were performed in eight U.S. climate zones. The baseline reference HVAC system incorporated packaged single-zone direct-expansion cooling with gas heating (PSZ-AC) or variable-air-volume systems (VAV with reheat). An alternate baseline HVAC system using a heat pump (PSZ-HP) was included for some buildings to directly compare gas and electric heating results. These baseline systems were compared to a VRF heat pump model to identify differences in energy use. VRF systems combine multiple indoor units with one or more outdoor unit(s). These systems move refrigerant between the outdoor and indoor units which eliminates the need for duct work in most cases. Since many applications install duct work in unconditioned spaces, this leads to installation differences between VRF systems and conventional HVAC systems. To characterize installation differences, a duct heat gain model was included to identify the energy impacts of installing ducts in unconditioned spaces. The configuration of variable refrigerant flow heat pumps will ultimately eliminate or significantly reduce energy use due to duct heat transfer. Fan energy is also studied to identify savings associated with non-ducted VRF terminal units. VRF systems incorporate a variable-speed compressor which may lead to operational differences compared to single-speed compression systems. To characterize operational differences, the computer model performance curves used to simulate cooling operation are also evaluated. The information in this paper is intended to provide a relative difference in system energy use and compare various installation practices that can impact performance. Comparative results of VRF versus conventional HVAC systems include energy use differences due to duct location, differences in fan energy when ducts are eliminated, and differences associated with electric versus fossil fuel type heating systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock 2024.2 Dataset [Slides]

In the ResStock 2024.2 dataset, ResStock runs are used to create "what-if" scenarios including energy efficiency measures such as heat pumps, envelope improvements, and electrification of appliances. This dataset release includes 15 measure packages across two weather years and incorporates ResStock improvements in variable speed heat pump modeling, geothermal heat pump modeling, and housing characteristic data updates from RECS 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus

This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Verification of a VRF Heat Pump Computer Model in EnergyPlus

This paper provides verification results of the EnergyPlus variable refrigerant flow (VRF) heat pump computer model using manufacturer's performance data. The paper provides an overview of the VRF model, presents the verification methodology, and discusses the results. The verification provides quantitative comparison of full and part-load performance to manufacturer's data in cooling-only and heating-only modes of operation. The VRF heat pump computer model uses dual range bi-quadratic performance curves to represent capacity and Energy Input Ratio (EIR) as a function of indoor and outdoor air temperatures, and dual range quadratic performance curves as a function of part-load-ratio for modeling part-load performance. These performance curves are generated directly from manufacturer's published performance data. The verification compared the simulation output directly to manufacturer's performance data, and found that the dual range equation fit VRF heat pump computer model predicts the manufacturer's performance data very well over a wide range of indoor and outdoor temperatures and part-load conditions. The predicted capacity and electric power deviations are comparbale to equation-fit HVAC computer models commonly used for packaged and split unitary HVAC equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Split Heat Pump Using Low GWP Refrigerants

Conventional refrigerants, e.g. R-410A have high global warming potentials (GWP) > 1800. They are being phased out to protect the environment. The candidates to replace R-410A include R-32, R-452B, R-454B and R-466A for heat pump applications. These candidates are intended for drop-in replacement, i.e. having minimum modifications on existing systems. The paper investigates the low GWP refrigerants drop-in application via system simulations using a well-regarded, hardware-based heat pump model. A baseline heat pump having all fin-and-tube heat exchangers and a two-speed compressor was used. Cross-comparisons were made under rated conditions of ambient temperatures, compressor speeds, indoor air flow rates, respectively for cooling and heating operations. The seasonal performance indices, i.e. SEER and HSPF are presented.

Shen, Bo↗

System Modeling of Frost/Defrost Cycles in Heat Pumps

Accurately modeling frost/defrost cycles is crucial for guiding heat exchanger design, appropriately sizing the compressor, and quantifying seasonal energy consumption for heating. While previous modelling studies of frosting cycle have predominantly focused on the component level of fin-and-tube coils, there has been limited development of models for system defrosting cycles. This study enhances the existing knowledge by improving a detailed, segment-to-segment heat exchanger model to simulate frost/defrost cycles for both fin-and-tube coils and microchannel heat exchangers. Furthermore, it integrates this component-level model into a steady-state/quasi-steady-state system modeling framework to simulate complete frost/defrost processes, i.e. the ORNL Heat Pump Design Model (HPDM). This comprehensive approach will unveil differences in coil types, and their interactions with the outdoor fan. It will also predict energy consumption patterns and time intervals associated with these processes.

Shen, Bo↗

Heat Pump Clothes Dryer Model Development

A heat pump clothes dryer (HPCD) is an innovative appliance that uses a vapor compression system to dry clothes. Air circulates in a closed loop through the drum, so no vent is required. The condenser heats air to evaporate moisture out of the clothes, and the evaporator condenses water out of the air stream. As a result, the HPCD can achieve 50% energy savings compared to a conventional electric resistance dryer. We developed a physics-based, quasi-steady-state HPCD system model with detailed heat exchanger and compressor models. In a novel approach, we applied a heat and mass transfer effectiveness model to simulate the drying process of the clothes load in the drum. The system model is able to simulate the inherently transient HPCD drying process, to size components, and to reveal trends in key variables (e.g. compressor discharge temperature, power consumption, required drying time, etc.) The system model was calibrated using experimental data on a prototype HPCD. In the paper, the modeling method is introduced, and the model predictions are compared with experimental data measured on a prototype HPCD.

Heat Pump Clothes Dryer↗