Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat-pipe Integrated Thermal Battery (HITB)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High-Temperature Latent Heat Storage System using Transportable Heat Pipes for Versatile Integration with Emerging Microreactors

With the growing interest in the development of micro nuclear reactors and their application to microgrid, high-temperature thermal energy storage (TES) has also been receiving great attention as a technology to reinforce the energy utilization and profitability of this class of reactors. Given the importance and research needs of the TES technology, a research project is underway at Idaho National Laboratory (INL) to develop high-temperature TES that can be easily interfaced with emerging micro nuclear reactors. Currently under development is the Heat pipe-Integrated Thermal Battery (HITB), a novel latent heat storage design that enables flexible and robust integration with any design of currently considered micro nuclear reactors. The development of detailed design based on the proposed TES concept, HITB, requires not only development and validation of modeling and simulation capabilities, but also research that spans thermal performance analysis, component- and system-scale design optimization, and experimental demonstrations including high-temperature feasibility testing. The current research efforts (and plans) are divided into the following four areas: (i) Thermal and structural modeling and analysis at both system- and component-scales for evaluating performance and conducting design optimization, (ii) Small-scale experimental demonstrations for the key components of the proposed HITB design, (iii) Modelica-based dynamic model development for developing a control strategy under dynamic operation within integrated energy systems configuration, (iv) Integrated experimental testing and demonstration. This paper introduces the overall research efforts that have been and are being conducted to develop and demonstrate the novel design of the high-temperature latent heat storage device, HITB. The key design features, ongoing research efforts including the development of modeling and simulation capabilities, small-scale demonstrations of the HITB’s key functionalities prior to scaled-up experimental demonstration, are discussed. Then, this paper concludes with a remark on the future research plans for this project.

25 ENERGY STORAGE↗

Development of Numerical Model of Metal Foam with PCM for the Estimation of Effective Thermal Conductivity

Global warming due to climate change is a threat to humankind. Nuclear energy is one of the promising solutions to reduce fossil fuel usage. Nuclear energy can handle the base load, compensating for the volatility of renewable energy. If nuclear energy could achieve load following capability, the combination with renewable energy would be more suitable. Thermal energy storage (TES) is one of the options for enabling load following of nuclear reactors. The TES makes it possible to store surplus nuclear thermal energy and release it later as needed. In Idaho National Laboratory (INL), a new concept of latent heat TES integrated with high-temperature heat pipe has been proposed and is under development, which is called Heat pipe-Integrated Thermal Battery (HITB). HITB exchanges thermal energy between the reactor system and TES via heat pipe. The heat transferred to TES medium, made of phase change material (PCM), stores energy as sensible heat and/or latent heat. As PCM typically has poor thermal conductivity, however, various heat transfer enhancement techniques are required to achieve a rapid charging cycle. There are many techniques to enhance the heat transfer ability of TES medium such as disk, fin, and metal foam. Among them, metal foam is an appropriate option to enhance the heat transfer because it maximizes the heat transfer area through metal wicks. Metal foam is a lightweight metal structure that has a high porosity of over 0.9. The typical materials for metal foam are Aluminum, Copper, Nickel, and Silicon Carbide (SiC). Metal foam not only enhances heat transfer via conduction but also increases contact surface area. In the HITB design , the metal foam is being considered as one of the options to enhance the heat transfer of TES medium (PCM) [1]. To predict the enhanced thermal performance of TES, one should properly estimate the effective thermal conductivity of metal foam combined with PCM material or calculate heat transfer in distributed model. There are many experimental works that provides effective thermal conductivity of metal foam with various PCM [2,3]. Also, many theoretical models were developed based on the unit cell model of metal foam [4,5]. With a distributed model, on the other hand, detail heat transfer characteristics between metal foam and PCM material can be analyzed considering the geometry or buoyancy effect. However, due to the complex geometry of metal foam pores, the computational cost for three-dimensional modeling highly increases. Therefore, if metal foam structure can be modeled in simple and repetitive design, the computational cost would decrease Among the various metal foam models [2], lattice model is one of the simple and extendable design. The porosity and pores per inch (PPI) can be characterized by the size and spatial distance of lattice structure. If the three-dimensional metal foam model consists of lattice structure could properly estimate the heat transfer, which is characterized by effective thermal conductivity, it would be a good option to assess the thermal performance of metal foam with PCM. In this study, a three-dimensional numerical model was developed to simulate conductive heat transfer between metal foam and PCM. The three-dimensional lattice structure of square pillars was selected as a basic structure of the metal foam. The calculation result was characterized by the effective thermal conductivity of the whole domain. A sensitivity study was conducted for mesh size, domain size, and PPI to check whether the calculation result gives a converged result or not. Lastly, the effective thermal conductivity from the lattice model was compared with existing experimental data to validate the model result

25 ENERGY STORAGE↗

Corrosion evaluation of metal foams in eutectic molten salts for high temperature latent heat energy storage application

High-temperature Thermal Energy Storage (TES) has drawn great attention as a technology that can increase the role and profitability of micro nuclear reactors in the decentralized clean energy market. Various research needs have been proposed by Idaho National Laboratory (INL) in "the Integrated Energy Systems: 2020 Roadmap" with the goal of utilizing the high temperature of 550 degrees or more generated in the 4th generation reactor to industrial purposes from the standpoint of integrated energy systems [1]. With the recent development of the 4th generation nuclear power plant, including micro nuclear reactor, there is a great deal of interest in researching how to efficiently couple a heat source to an industrial process through thermal processing. Texas A&M University (TAMU) and INL are currently collaborating to develop a novel latent heat storage design called HITB (Heat pipe-Integrated Thermal Battery). As part of the small-scale experimental demonstration research for HITB, a study for storage medium selection was conducted at TAMU. Eutectic salts have attracted interest as high-temperature heat storage medium for HITB. Especially, chloride molten salts and fluoride molten salts are considered promising candidates due to their high melting temperature, thermal stability, and high latent heat of fusion. Since eutectic salts have poor thermal conductivity in general, it is critical to distribute materials with high thermal conductivity evenly to facilitate the charging and discharging of heat. In this study, metal foam was considered in the HITB system to overcome the poor heat transfer characteristics of eutectic salts. In order to improve heat transfer, it is necessary to study materials with high thermal conductivity, corrosion resistant to molten salts, such as fins, extended surfaces, particles, microcapsulation, or foam structure. Porous structure of copper or aluminum can increase heat transfer area, form a thermal transfer network, and increase the effective thermal conductivity of thermal storage medium [2]. Since the melting temperature is required to be at least 450? in the current HITB design, various eutectic salts are being considered. FLiNaK and FLiBe, which are famous for fluoride salts, are good candidates, but due to the sharp rise in the price of LiF recently, they are excluded for economic reasons to be applied to large-capacity thermal energy storage. On the other hand, chloride salts are very cheap and easy to obtain, have a high melting temperature, and have a high latent heat of fusion, so they are recently in the spotlight as a phase change material. However, because of the hygroscopic nature of chloride salts, HCl gas due to impurity is easy to be released and is particularly vulnerable to corrosion. Chloride eutectic salts have been tested and suggested for metal alloys that are particularly resistant to corrosion, such as SS304, SS316, Hastelloy, Inconel 625, Incoloy 800H, which has low thermal conductivity, and is very expensive [3-6]. Porous materials with high thermal conductivity such as copper and aluminum have been tested for stability in fluids such as paraffin or water as metal foam or metal fin structures, but high temperature corrosion tests were not performed on various eutectic salts yet. Therefore, this study investigated the high temperature corrosion characteristics of metal alloys, such as C10100 foam, C10100 plate, 6101 alloy foam, and SS316 plate, while immersed in the candidate eutectic salts. A total of 20 tests for SS316 coupons and 10 tests for C10100 coupons were performed to ensure the repeatability of the present measurements. Since it is difficult to completely remove the salt inside metal foam due to the complex inner structure of the metal foam, only the surface condition was observed with a microscopy and scanning electron microscopy (SEM) image, except for measuring the corrosion rate and average mass loss.

25 ENERGY STORAGE↗