SEARCH · Search NASA
Results for “Heating Augmentation”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Assessment of NuScale SMR Steam Heat Augmentation for Chemical Plant Decarbonization
Nearly 50% of the total energy consumed by the industrial sector in the United States is used to produce process steam with natural gas and coal-fired boilers1 . This project conducts a technoeconomic assessment of a NuScale Small Modular Reactor (SMR) coupled with a chemical plant as an Integrated Energy System (IES) where nuclear produces steam and electric power to meet the requirements of a large chemical plant. In a 2020 study, ORNL evaluated the feasibility of using advanced SMRs, including the NuScale design, to supply energy to the Eastman Chemical Plant. However, since that report was published, NuScale received NRC approval for its uprated 77 MWe design with 56% more power and has also introduced a high-temperature, high pressure, steam heat-augmentation system, a key focus of the new study. The new study also benefits from revised capital costs, a 10-day refueling outage time, reduced plant staffing, higher capacity factors, and a site boundary Emergency Planning Zone methodology. The study consists of a techno-economic assessment of two possible energy sources (nuclear and natural gas) in a number of steam and power generation configurations (NuScale Power Modules (NPMs), boilers and combinations of both) to satisfy the steam and power demand with the most reliable and cost competitive system. A total of 2,947.3 klb/hr of steam and 72.5 MWe of electricity are required for the demonstration case. A range of scenarios and solutions are explored, from a 12-NPM plant (3,000 MWth)—with excess capacity and redundancy, capable of supplying a significant amount of extra power to the grid—to a 4-NPM (1,000 MWth) plant—supplemented with existing boilers or grid power for redundancy. The study uses historical steam and power data from a chemical plant and examines the sensitivity to natural gas and grid power cost variations. Scenarios with up to two times gas and electricity costs were considered. Profitability in a 60-year time horizon was analyzed, consistent with NuScale’s design life specification. A steady-state site integration and reliability analysis was performed, and trade-offs were identified.
Heat pipe augmented passive solar heating system
A heat pipe augmented passive solar space heating system modulates the temperature inside a building structure, particular during heating seasons when the ambient temperature is below levels customarily associated with adequate room comfort, and in some embodiments comprises a solar absorber, a heat pipe surrounding wholly or partially by insulation, the heat pipe having three main sections which are an evaporator at one end proximal to the solar absorber, a condenser at the other end proximal to an interior room being heated, and a rubber adiabatic section between those. Additional aspects such as a mechanical valve in the adiabatic section are disclosed to limit unwanted thermal gains when cooling is needed because the ambient temperatures already exceed room comfort.
Heat transfer augmentation of natural convection heat sink through notched fin design
A novel notched fin heat sink with a central opening is proposed in the present study to augment the heat transfer performance of the natural convection heat sink under horizontal configuration. Thermal and airflow behavior in the heat sinks were studied using both experimental and numerical methods. The results showed that the performance of the conventional heat sink can be enhanced by optimizing its fin design. The basic heat sink model provided a 17% reduction in thermal resistance when its fin height and fin spacing were doubled, and it was accompanied by a 21% increase in surface area. The heat sink with a notched fin design with a less surface area offered a 13% lower thermal resistance compared to the basic model by entraining more airflow into the interior fin region. Providing a central opening in the notched fin heat sink can further reduce the thermal resistance by about 13%. Further, this study also analyzed the influence of emissivity of the heat sink on natural convection conditions. The findings demonstrated that the heat sink with an emissivity of 0.9 can reduce the thermal resistance by nearly 23% compared to one with an emissivity of 0.15.
Stagnation Region Heat Transfer Augmentation at Very High Turbulence Levels
A database for stagnation region heat transfer has been extended to include heat transfer measurements acquired downstream from a new high intensity turbulence generator. This work was motivated by gas turbine industry heat transfer designers who deal with heat transfer environments with increasing Reynolds numbers and very high turbulence levels. The new mock aero-combustor turbulence generator produces turbulence levels which average 17.4%, which is 37% higher than the older turbulence generator. The increased level of turbulence is caused by the reduced contraction ratio from the liner to the exit. Heat transfer measurements were acquired on two large cylindrical leading edge test surfaces having a four to one range in leading edge diameter (40.64 cm and 10.16 cm). Gandvarapu and Ames [1] previously acquired heat transfer measurements for six turbulence conditions including three grid conditions, two lower turbulence aero-combustor conditions, and a low turbulence condition. The data are documented and tabulated for an eight to one range in Reynolds numbers for each test surface with Reynolds numbers ranging from 62,500 to 500,000 for the large leading edge and 15,625 to 125,000 for the smaller leading edge. The data show augmentation levels of up to 136% in the stagnation region for the large leading edge. This heat transfer rate is an increase over the previous aero-combustor turbulence generator which had augmentation levels up to 110%. Note, the rate of increase in heat transfer augmentation decreases for the large cylindrical leading edge inferring only a limited level of turbulence intensification in the stagnation region. The smaller cylindrical leading edge shows more consistency with earlier stagnation region heat transfer results correlated on the TRL (Turbulence, Reynolds number, Length scale) parameter. The downstream regions of both test surfaces continue to accelerate the flow but at a much lower rate than the leading edge. Bypass transition occurs in these regions providing a useful set of data to ground the prediction of transition onset and length over a wide range of Reynolds numbers and turbulence intensity and scales.
Stagnation region heat transfer augmentation at very high turbulence levels
Current land-based gas turbines are growing in size producing higher approach flow Reynolds numbers at the leading edge of turbine nozzles. These vanes are subjected to high intensity large scale turbulence. This present paper reports on the research which significantly expands the parameter range for stagnation region heat transfer augmenta-tion due to high intensity turbulence. Heat transfer measurements were acquired over two constant heat flux test surfaces with large diameter leading edges (10.16 cm and 40.64 cm). The test surfaces were placed downstream from a new high intensity (17.4%) mock combustor and tested over an eight to one range in approach flow Reynolds number for each test surface. Stagnation region heat transfer augmentation for the smaller (Re D = 15,625–125,000) and larger (Re D = 62,500–500,000) leading edge regions ranged from 45% to 81% and 80% to 136%, respectively. Furthermore, these data also include heat transfer distributions over the full test surface compared with the earlier data acquired at six additional inlet turbulence conditions. These surfaces exhibit continued but more moderate acceleration downstream from the stagnation regions and these data are expected to be useful in testing bypass transition predictive approaches. This database will be useful to gas turbine heat transfer design engineers. [DOI: 10.1115/1.4032677]
System Modeling of Gas Engine Driven Heat Pump
To improve the system performance of the GHP, modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated by using ORNL Modulating Heat Pump Design Software, which is used to predict steady-state heating and cooling performance of variable-speed vapor compression air-to-air heat pumps for a wide range of operational variables. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using desiccant system regenerated by waste heat from engine, the SHR can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% in rated operating conditions.
System Modeling and Building Energy Simulations of Gas Engine Driven Heat Pump
To improve the system performance of a gas engine driven heat pump (GHP) system, an analytical modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system the sensible heat ratio (SHR- sensible heat ratio) can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion,using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of GHP in sixteen US cities, and the performances are compared to a baseline unit, which has a electrically-driven air conditioner with the seasonal COP of 4.1 for space cooling and a gas funace with 90% fuel efficiency for space heating.
Investigation of heat pump technologies for high-temperature applications above 250 °C
This paper examines heat pump (HP) technologies to achieve heat supply temperatures above 250 °C, referred to as ultra-high-temperature heat pump (UHTHP). UHTHP, as a low-carbon heat delivery and heat augmentation technology, can offer an alternative to traditional combustion heating for decarbonizing high-temperature industrial processes. However, the heat supply temperature of over 250 °C surpasses the temperature range typically covered in the high-temperature HP literature and existing capabilities of commercial HP systems. This paper reviews HP technologies with the potential to evolve into UHTHP. Additionally, UHTHP studies in the literature are analyzed to compare the pros, cons, and technical potentials of various HPs using different thermodynamic cycles and fluids. Furthermore, we then pinpoint the technical gaps and challenges that have hindered widespread adoption of UHTHP in industry, explore potential improvements and solutions, and discuss the feasibility. Current efforts aim to lay the ground for future research, development, and commercial deployment for UHTHP.
Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump
Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.
Experimental and Numerical Analysis of Additively Manufactured Inconel 718 Coupons With Lattice Structure
Abstract In the present paper, two lattice geometries suitable for near surface and double wall cooling were developed and tested. The first type of unit cell consisted of six ligaments of 0.5 mm diameter joined at a common vertex near the middle. The second type of unit cell was derived from the first type by adding four mutually perpendicular ligaments in the middle plane. Two lattice configurations, referred to as L1 and L2, respectively, were obtained by repeating the corresponding unit cell in streamwise and spanwise directions in an inline fashion. Test coupons consisting of these lattice geometries embedded inside rectangular cooling channel with dimensions of 2.54 mm height, 38.07 mm width, and 38.1 mm in length were fabricated using Inconel 718 powder and selective laser sintering (SLS) process. The heat transfer and pressure drop performance was then evaluated using steady-state tests with constant wall temperature boundary condition and for channel Reynolds number ranging from 2800 to 15,000. The lattices depicted a higher heat transfer compared with a smooth channel and both the heat transfer and pressure drop increased with a decrease in the porosity from L1 to L2. Steady-state conjugate numerical results revealed formation of prominent vortical structures in the inter-unit cell spaces, which diverted the flow toward the top end wall and created an asymmetric heat transfer between the two end walls. In conclusion, these lattice structures provided an augmented heat transfer while favorably redistributing the coolant within channel.
Gas Engine-Driven Heat Pump with Desiccant Dehumidification
About 40% of total U.S. energy consumption was consumed in residential and commercial buildings. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. This paper describes the development of an innovative natural gas, propane, LNG or bio-gas IC engine-driven heat pump (GHP) with desiccant dehumidification (GHP/DD). This integrated system has higher overall efficiencies than conventional equipment for space cooling, addresses both new and existing commercial buildings, and more effectively controls humidity in humid areas. Waste heat is recovered from the GHP to provide energy for regenerating the desiccant wheel and to augment heating capacity and efficiency. By combining the two technologies, an overall source COP of greater that 1.5 (hot, humid case) can be achieved by utilizing waste heat from the engine to reduce the overall energy required to regenerate the desiccant. Moreover, system modeling results show that the sensible heat ratio (SHR- sensible heat ratio) can be lowered to less 60% in a dedicated outdoor air system application with hot, humid cases.
Control of Ion Distortion in Field Asymmetric Waveform Ion Mobility Spectrometry via Variation of Dispersion Field and Gas Temperature
Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as an analytical tool of broad utility, especially in conjunction with mass spectrometry. Of particular promise is the use of FAIMS and 2-D ion mobility methods that combine it with conventional IMS to resolve and characterize protein and other macromolecular conformers. However, FAIMS operation requires high electric fields and ions are inevitably heated by above-thermal collisions with buffer gas molecules. This may induce ion isomerization and dissociation that distort separation properties determined by FAIMS and subsequent stages and/or reduce instrumental sensitivity. As FAIMS employs a periodic waveform, the ion temperature can be characterized at the maximum or average field intensity (E). Which method is most applicable to temperature sensitive ions, such as protein ions, has been debated. Here we address this issue by measuring the unfolding of compact ubiquitin ion geometries as a function of waveform amplitude (dispersion field, ED) and gas temperature, T. The field heating is quantified by matching the dependences of structural transitions on ED and T. Increasing ED from 12 to 16 or from 16 to 20 kV/cm is equivalent to heating the (N2) gas by ~15 - 25 oC. The magnitude of field heating for any E can be calculated using the two-temperature theory, and raising ED by 4 kV/cm augments heating by ~15 - 30 oC for maximum and ~4 - 8 oC for average E in the FAIMS cycle. Hence, isomerization of ions in FAIMS appears to be governed by the maximum internal temperature at waveform peaks.
Cold Climate Heat Pumps Using Tandem Compressors
In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.
Improved Heat Transfer and Volume Scaling through Novel Heater Design
In 2014, the University of California, Berkeley, Nuclear Engineering Thermal Hydraulics Laboratory completed construction of the Compact Integral Effects Test (CIET) facility, a scaled thermal hydraulics scaled integral effects test facility designed to model the Mark-1 pebble-bed fluoride-salt-cooled high-temperature reactor (Mk1 PB-FHR or simply Mk1). CIET uses an organic simulant fluid, Dowtherm A, to match the Prandtl, Reynolds, Froude, and Grashof numbers of important fluoride salt candidates for molten salt reactors, such as flibe. The FHR reactor core is simulated using a resistively heated tube, which heats the oil flowing through the annulus between the heated tube and a non-heated inner tube. However, the volume fraction of the coolant in the CIET heater was dramatically lower than the volume fraction of the primary coolant in the Mk1 PB-FHR design (3% in CIET vs. 17% in Mk1) because the CIET heater was initially scaled to match an earlier FHR design. Also, the maximum core heater power in CIET is limited by the melting point of Teflon components in CIET, approximately 330 deg. C. For conservatism, the CIET heater power is limited to keep the maximum surface temperature of the heater below 250 deg. C. At the nominal mass flow rate of 0.18 kg/s, this power was about 5 kW. A higher heat transfer coefficient from the heater wall to the oil was needed to increase the effective power delivered to the oil. In order to alleviate these two limitations, a new heater insert was designed and constructed for CIET. This new heater insert uses a twisted tape to augment heat transfer. The twisted tape is supported inside a perforated inner tube that has the same diameter as the original inner tube of the heater, in order to make it compatible with CIET's original heater design. The heat transfer and pressure drop properties of the new heater insert designs were tested in CIET and compared to the previous design in terms of pressure drop and convective heat transfer coefficient. The new heater inserts are intended to increase the range of power levels and mass flow rates that can be tested in CIET in order to augment understanding of FHR thermal hydraulic phenomena. Also, obtaining different data points for CIET response dynamics under different heater coolant residence times will be valuable in evaluating the Mk1 design.
Heat transfer enhancement due to cold cap motion from bubbling in a waste glass melter
In this study, a computational fluid dynamics (CFD) model was developed to model the motion of a solid cold cap in a waste glass melter. Forced convection bubblers at the base of the melter release air into the molten glass, which forms large bubbles that travel upwards to the cold cap and augment heat transfer from the glass to the cold cap. The CFD model employs the Navier- Stokes equations to solve for the fluctuating flowfield using a rigid body motion dynamic fluid body interaction module. This allows for movement of the floating body in response to the bubbling forces calculated at each time step. Further, the heat flux delivered to the cold cap by the convective bubbling is studied as a function of the bubbling rate. Results for the moving cold cap are compared with the computed heat flux trends for a stationary cold cap. The heat flux delivered to the cold cap from the glass is 25% higher for the case with the moving cold cap. The heat flux was found to be proportional to v0.6 as opposed to v0.9 (where v is the normalized bubbling rate) for the stationary cold cap.
Sweeping Jet Film Cooling on a Turbine Vane
The cooling performance of sweeping jet film cooling was studied on a turbine vane suction surface in a low-speed linear cascade wind tunnel. The sweeping jet holes consist of fluidic oscillators with an aspect ratio (AR) of unity and a hole spacing of Pd/D = 6. Infrared (IR) thermography was used to estimate the adiabatic film effectiveness at several blowing ratios and two different freestream turbulence levels (Tu = 0.3% and 6.1%). Convective heat transfer coefficient was measured by a transient IR technique, and the net heat flux benefit was calculated. The total pressure loss due to sweeping jet film cooling was characterized by traversing a total pressure probe at the exit plane of the cascade. Tests were performed with a baseline shaped hole (SH) (777-shaped hole) for comparison. The sweeping jet hole showed higher adiabatic film effectiveness than the 777-shaped hole in the near hole region. Although the unsteady sweeping action of the jet augments heat transfer, the net positive cooling benefit is higher for sweeping jet holes compared to 777 hole at particular flow conditions. The total pressure loss measurement showed a 12% increase in total pressure loss at a blowing ratio of M = 1.5 for sweeping jet hole, while 777-shaped hole showed a 8% total pressure loss increase at the corresponding blowing ratio.
Impact of Additive Manufacturing on Internal Cooling Channels With Varying Diameters and Build Directions
Abstract The use of additive manufacturing (AM) processes, such as direct metal laser sintering, provides the design freedom required to incorporate complex cooling schemes in gas turbine components. Additively manufactured turbine components have a range of cooling feature sizes and, because of the inherent three-dimensionality, a wide range of build angles. Previous studies have shown that AM built directions influence internal channel surface roughness that, in turn, augment heat transfer and pressure loss. This study investigates the impact of AM on channel feature size and builds direction relative to tolerance, surface roughness, pressure losses, and convective cooling. Multiple AM coupons were built from Inconel 718 consisting of channels with different diameters and a variety of build directions. An experimental rig was used to measure pressure drop to calculate friction factor and was used to impose a constant surface temperature boundary condition to collect Nusselt number over a range of Reynolds numbers. Significant variations in surface roughness and geometric deviations from the design intent were observed for distinct build directions and channel sizes. These differences led to notable impacts in friction factor and Nusselt number augmentations, which were a strong function of build angle.