Search NASA⌕ Search

SEARCH · Search NASA

Results for “Helicity Injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Formation of closed flux surfaces in spheromaks sustained by steady inductive helicity injection

The helicity injected torus with steady inductive helicity injection device is a simply-connected toroidal device that forms and sustains axisymmetric spheromak equilibria through the use of steady inductive helicity injection, which inject magnetic helicity through the inductive drive of non-axisymmetric currents on the edge of the plasma. Simulations of high-gain scenarios, using the NIMROD code and based on models validated with low gain experimental operations, indicate the formation of closed flux surfaces at current amplifications of six. Despite the helicity injection scheme adding magnetic perturbations of order δb/B ~ 10%, these closed flux equilibria are able to persist for as long as 20 injector periods (1.3 ms) before breaking apart due to other plasma generated instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak

Open field line currents are intrinsic to DC helicity injection plasma startup and pose a challenge for inferring the plasma equilibrium with standard reconstruction analysis. Local helicity injection (LHI) is a type of DC helicity injection which uses small, modular current sources to drive force-free current along helical field lines to produce tokamak plasmas. MHD modeling and magnetic measurements during LHI indicate the injected current streams remain coherent as helical structures on the outboard edge of a core toroidal plasma that is tokamak-like in a toroidally averaged sense. To extract core plasma equilibrium properties, external magnetic diagnostics corrected for contributions from the injected current streams are fitted by a standard Grad-Shafranov equilibrium code. An iterative approach for estimating and subtracting the stream contributions from the diagnostic signals is described and applied to a model equilibrium database to reduce systematic errors introduced by the streams. Convergence is usually attained with 2 to 4 iterations, with derived equilibrium parameters matching the prescribed axisymmetric core values to within estimated experimental uncertainties. Accurate recovery of core parameters occurs when the ratio of the net toroidal windup current from the streams to the core plasma current is less than 0.2, which is typically satisfied in most experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initiation and sustainment of tokamak plasmas with local helicity injection as the majority current drive

Local helicity injection (LHI) is a non-solenoidal current drive capable of achieving high- I p tokamak startup with non-invasive current injectors in the plasma scrape-off layer. The choice of injector location within the edge region is flexible but has a profound influence on the nature of the current drive in LHI discharges. New experiments on the Pegasus ST with injection in the high-field-side, lower divertor region produce plasmas dominated by helicity injection current drive, static plasma geometry, and negligible inductive drive. Peak plasma current up to 200 kA, and a sustained plasma current of 100 kA for up to 18 ms, is demonstrated. Maximum achievable plasma current is found to scale approximately linearly with the effective loop voltage from LHI. A newly-observed MHD regime for LHI-driven plasmas in which large-amplitude n = 1 fluctuations at 20–50 kHz are abruptly reduced on the outboard side results in improved current drive. In conclusion, a simultaneous increase in high frequency fluctuations (>400 kHz) inside the plasma edge suggests short wavelength turbulence as an important current drive mechanism during LHI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advancing local helicity injection for non-solenoidal tokamak startup

Experiments on the A ~ 1 PEGASUS ST are advancing the physics and technology basis of Local Helicity Injection (LHI). LHI injects helicity with relatively intense electron current sources in the plasma edge. It creates high toroidal current, toroidally-averaged tokamak-like plasmas that have been efficiently transitioned to Ohmically driven tokamak plasmas. Tradeoffs between physics and engineering goals are tested with LHI systems on the low-field-side and the high-field-side of PEGASUS, producing plasmas predominantly driven by non-solenoidal induction and DC helicity drive, respectively. An extensive LHI source development campaign comparing active arc sources, passive and gas-effused electrode sources lead to the selection of active arc sources for present and next-step LHI deployments. LHI plasmas with net toroidal current I p =0.225 MA, T e >100 eV, and n e ~ 10 19 m -3 are attained to date. A predictive 0D power-balance model describes experimental I p (t) and partitions the active current drive sources. High-frequency MHD activity is found to be present during LHI current drive, in addition to n=1 modes previously found in NIMROD simulation and experiment. A new system of reduced MHD activity was detected where n=1 activity is suppressed, LHI CD efficiency improves, and long-pulse plasmas are sustained with V IND ~ 0.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Public Data Set: Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak

This public data set contains openly-documented, machine readable digital research data corresponding to figures published in J.D. Weberski et al., 'Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak,' Journal of Fusion Energy 43, 72 (2024).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Global-Scale Consequences of Magnetic-Helicity Injection and Condensation on the Sun

In the recent paper of Antiochos, a new concept for the injection of magnetic helicity into the solar corona by small-scale convective motions and its condensation onto polarity inversion lines (PILs) has been developed. We investigate this concept through global simulations of the Sun's photospheric and coronal magnetic fields and compare the results with the hemispheric pattern of solar filaments. Assuming that the vorticity of the cells is predominately counter-clockwise/clockwise in the northern/southern hemisphere, the convective motions inject negative/positive helicity into each hemisphere. The simulations show that: (i) On a north-south orientated PIL, both differential rotation and convective motions inject the same sign of helicity which matches that required to reproduce the hemispheric pattern of filaments. (ii) On a high latitude east-west orientated polar crown or sub-polar crown PIL, the vorticity of the cells has to be approximately 2-3 times greater than the local differential rotation gradient in order to overcome the incorrect sign of helicity injection from differential rotation. (iii) In the declining phase of the cycle, as a bipole interacts with the polar field, in some cases helicity condensation can reverse the effect of differential rotation along the East-West lead arm, but not in all cases. The results show that this newly developed concept of magnetic helicity injection and condensation is a viable method to explain the hemispheric pattern of filaments in conjunction with the mechanisms used in Yeates et al. (2008). Future observational studies should focus on determining the vorticity component within convective motions to determine, both its magnitude and latitudinal variation relative to the differential rotation gradient on the Sun.

magnetic fields↗

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,↗

Plasma density injection and flow during coaxial helicity injection in a tokamak

Whole device, resistive MHD simulations of spheromaks and tokamaks have used a large diffusion coefficient that maintains a nearly constant density throughout the device. In the present work, helicity and plasma are coinjected into a low-density plasma in a tokamak with a small diffusion coefficient. As in previous simulations [Hooper et al., Phys. Plasmas 20, 092510 (2013)], a flux bubble is formed, which expands to fill the tokamak volume. The injected plasma is non-uniform inside the bubble. The flow pattern is analyzed; when the simulation is not axisymmetric, an n = 1 mode on the surface of the bubble generates leakage of plasma into the low-density volume. Closed flux is generated following injection, as in experiments and previous simulations. The result provides a more detailed physics analysis of the injection, including density non-uniformities in the plasma that may affect its use as a startup plasma [Raman et al., Phys. Rev. Lett. 97, 175002 (2006)].

Hooper, E. B. (ORCID:0000000251197451)↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A power-balance model for local helicity injection startup in a spherical tokamak

A 0D circuit model for predicting I p ( t ) in Local Helicity Injection (LHI) discharges is developed. Analytic formulas for estimating the surface flux of finite-A plasmas developed are modified and expanded to treat highly shaped, ultralow-A tokamak geometry using a database of representative equilibria. Model predictions are compared to sample LHI discharges in the A ~ 1 Pegasus spherical tokamak, and are found to agree within 15% of experimental I p ( t ). High performance LHI discharges are found to follow the Taylor relaxation current limit for approximately the first half of the current ramp, or I p ≲ 75 kA. The second half of the current ramp follows a limit imposed by power-balance as plasmas expand from high- A to ultralow- A . Here, this shape evolution generates a significant drop in external plasma inductance, effectively using the plasma’s initially high inductance to drive the current ramp and provide > 70% of the current drive V-s. Projections using this model indicate the relative influences of higher helicity input rate and injector current on the attainable total plasma current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helicity Injected Torus (HIT): Sustainment of Stable Equilibria Through Self-organization

This is the Final Progress Report of the Helicity Injected Torus (HIT) program covering May 2016 through December 2020. During this final period the HIT program continued to make advancements in computational modeling, theory, and experimental studies of global self-organization and inductively sustained spheromaks. This included many valuable contributions to the fusion, plasma and physics community, through peer-reviewed publications, PhD theses and conference presentations and posters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Test of Point-Source Helicity Injection for Non-Solenoidal Startup in NSTX

This grant supported research activity focused on the development of Local Helicity Injection (LHI) as a technique for initiation and growth of spherical tokamak plasmas without the use of a traditional ohmic solenoid for magnetic induction. The LHI technique consists of injection of high-density current streams into a vacuum magnetic field consisting of toroidal and vertical fields. Under appropriate conditions, these streams become unstable and support magnetic reconnection to allow the system to reconfigure itself into a tokamak-like plasma magnetic configuration. This research program focused on three aspects of this plasma startup technique: 1) development and tests of appropriate electron current sources that provide sufficiently high injection currents into the near-plasma edge without strongly contaminating the resultant tokamak plasma with impurities; 2) development and validation of a 0-D power balance model to describe the evolution of the plasma current I p (t) during this startup process; and 3) initial estimates of I p levels achievable with this technique in NSTX-U scale plasmas. The 0-D model development included extremely low aspect ratio corrections to analytical formulae for the plasma inductances that produce voltages due to rapid changes in plasma size and location. Applications of this model to sample plasmas in the Pegasus ultra-low aspect ratio tokamak confirms the expectation that I p (t) is dominated by these induced voltages when injection occurs from the outer low-field side of the plasma. Conversly, I p (t) is dominated by an effective toroidal loop voltage arising from helicity conservation when injectors are placed in the inner high-field side divertor region. The activities pursued here, combined with more general research on LHI followed by the Pegasus experiment group, provide the tools needed for initial consideration of a MA-level plasma startup capability for the NSTX-U experiment. Simplified modeling for LHI on NSTX-U indicates that no showstoppers exist, and ~ 0.8MA appears accessible using a moderate current injection facility. However, many issues remain to be resolved to address extrapolating this technique to the larger sizes and magnetic field strengths of NSTX-U and larger fusion-grade tokamaks. These include, among others: I p scaling with helicity drive input; extending current injector technology; understanding electron confinement and the resulting helicity dissipation processes that determine the achievable I p ; the role of plasma stability in controlling the current evolution; and controlling plasma-material interactions and impurity content. These open issues will be further explored in a future experiment dedicated to integrated studies of non-solenoidal startup at higher magnetic fields and plasma currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional plasmoid-mediated reconnection and the effect of toroidal guide field in simulations of coaxial helicity injection

Physics of three-dimensional plasmoid-mediated magnetic reconnection during transient Coaxial Helicity Injection (CHI) plasma start-up is explored using nonlinear MHD simulations in a spherical tokamak. We numerically examine (i) the role of three-dimensional magnetic fluctuations arising from current-sheet instabilities on the formation of plasmoid-mediated closed flux surfaces, and (ii) the effect of toroidal guide field on the MHD stability during transient CHI. Here, we find that even in the presence of nonaxisymmetric edge magnetic fluctuations, current-carrying axisymmetric (n = 0) plasmoids are rapidly formed while twisted open field lines are being injected and are merged to form a large current-carrying magnetic bubble for plasma startup in a tokamak. Additionally, it is discovered that the 3-D physics response is drastically different for simulations at a higher toroidal field, and complete stabilization of nonaxisymmetric fluctuations was achieved at a higher toroidal flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extension of Local Helicity Injection Startup Studies to the Urania Experiment (Final Technical Report)

Initiating high-current plasma in a spherical tokamak (ST) without a central solenoid is a critical issue for the development of the ST configuration. The goal of the research funded through this grant was focused on addressing this challenge by demonstrating scalable startup to high plasma current (I p ), while developing a physical understanding and predictive models for non-solenoidal tokamak plasma startup using Local Helicity Injection (LHI). A major objective of this research and development activity was to use scaling experiments to validate a physics understanding that will support deployment of high-current (~1 MA) startup techniques to fusion-scale facilities such as NSTX-U and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of multi-pulse coaxial helicity injection in the Sustained Spheromak Physics Experiment

Nonlinear, numerical computation with the NIMROD code is used to explore magnetic self-organization during multi-pulse coaxial helicity injection in the Sustained Spheromak Physics eXperiment. We describe multiple distinct phases of spheromak evolution, starting from vacuum magnetic fields and the formation of the initial magnetic flux bubble through multiple refluxing pulses and the eventual onset of the column mode instability. Experimental and computational magnetic diagnostics agree on the onset of the column mode instability, which first occurs during the second refluxing pulse of the simulated discharge. Our computations also reproduce the injector voltage traces, despite only specifying the injector current and not explicitly modeling the external capacitor bank circuit. Furthermore, the computations demonstrate that global magnetic evolution is fairly robust to different transport models and, therefore, that a single fluid-temperature model is sufficient for a broader, qualitative assessment of spheromak performance. Although discharges with similar traces of normalized injector current produce similar global spheromak evolution, details of the current distribution during the column mode instability impact the relative degree of poloidal flux amplification and magnetic helicity content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Erratum: “Initial characterization of electron temperature and density profiles in PEGASUS spherical tokamak discharges driven solely by local helicity injection” [Phys. Plasmas 28, 102504 (2021)]

Here, this article describes errata in 'Initial characterization of electron temperature and density profiles in PEGASUS spherical tokamak discharges driven solely by local helicity injection,' Phys. Plasmas 28, 102504 (2021) that correct reported electron temperature values and their implications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗