SEARCH · Search NASA
Results for “Helium cooling”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Reversed Heat Flux Study of Impinging-Jet Water Cooling for Helium-Cooled Finger-Type Divertors
Not provided.
Preliminary Assessment of Additively Manufactured Cooling Channel Performance for Helium-Cooled Blanket Concepts
Sufficient cooling of the blanket first wall remains a critical challenge for the design and deployment of fusion power plants. Helium has been targeted as a potential blanket coolant due to its inertness and low neutron interactivity, among other advantages. However, the low thermal mass of helium creates a need for heat transfer enhancements in coolant channels to provide adequate cooling to the blanket’s first wall. Toward this end, a series of ribbed flow channels of various rib cross sections and configurations has been produced via additive manufacturing (AM) to study the efficacy of AM for first wall heat transfer enhancement and the optimization of heat transfer geometries. Helium cooling performance is studied in AM test articles at 4 MPa operating pressure, Reynolds numbers up to 197 000, and outer surface heat fluxes up to 42 kW/m 2 in the recently commissioned helium flow loop experiment (HFLE). Preliminary results of this study are presented herein. Heat transfer performance of nominally smooth (i.e., featureless) AM channels is quantified via measured Nusselt numbers and friction factors and compared to off-the-shelf smooth pipe experiments. Results are compared to existing correlations and used to discuss the effects of the AM processes on thermal-hydraulic performance. It is seen that the inherent roughness of the AM channels leads to an increase in both heat transfer coefficient and pressure drop when compared to the conventional pipe. In conclusion, recommendations are made for future studies based on these findings and additional considerations for the deployment of AM blanket cooling components.
Liquid helium-cooled MOSFET preamplifier for use with astronomical bolometer
A liquid helium-cooled p-channel enhancement mode MOSFET, the 3N167, is found to have sufficiently low noise for use as a preamplifier with helium-cooled bolometers that are used in infrared astronomy. Its characteristics at 300, 77, and 4.2 K are presented. It is also shown to have useful application with certain photoconductive and photovoltaic infrared detectors.
A methodology for accident analysis of fusion breeder blankets and its application to helium-cooled lead–lithium blanket
'Fusion for Energy' (F4E) is designing, developing, and implementing the European Helium-Cooled Lead-Lithium (HCLL) and Helium-Cooled Pebble-Bed (HCPB) Test Blanket Systems (TBSs) for ITER (Nuclear Facility INB-174). Safety demonstration is an essential element for the integration of these TBSs into ITER and accident analysis is one of its critical components. A systematic approach to accident analysis has been developed under the F4E contract on TBS safety analyses. F4E technical requirements, together with Amec Foster Wheeler and INL efforts, have resulted in a comprehensive methodology for fusion breeding blanket accident analysis that addresses the specificity of the breeding blanket designs, materials, and phenomena while remaining consistent with the approach already applied to ITER accident analyses. Furthermore, the methodology phases are illustrated in the paper by its application to the EU HCLL TBS using both MELCOR and RELAP5 codes.
An Experimental Reversed Heat Flux Investigation of the Helium-Cooled Modular Divertor with Multiple Jets
The Georgia Institute of Technology group has performed studies to characterize the thermal hydraulics of a single “finger” module of the helium-cooled modular divertor with multiple jets (HEMJ) proposed for long-pulse magnetic fusion reactors in a helium (He) loop designed with maximum mass flow rate of 10 g/s. However, testing divertor modules at prototypical heat fluxes and temperatures remains an engineering challenge. A new larger helium loop with a maximum mass flow rate of 100 g/s, suitable for evaluating helium-cooled divertors with larger surface areas such as a nine-finger HEMJ module, is currently being constructed. This work presents an experimental validation of a numerical model exploring the applicability of the “reversed heat flux approach,” which cools (versus heats) the plasma-facing surface of the divertor module to evaluate the helium-side heat transfer coefficient (HTC). The approach is to be used for performance evaluation of single and multiple modules of HEMJ in existing and future large helium loops. A cooling facility for producing a jet of water with a maximum mass flow rate of 1.4 kg/s at a maximum pressure of 0.4 MPa and temperature of 295 K (Re = 2.2 × 10 5 ) is described. Numerical and experimental results are presented for the heat flux and average helium impingement surface temperature over a range of water flow rates (0.5 to 1.4 kg/s) for heat fluxes as high as 5 MW/m 2 . The numerical model suggests that the HTC of the water impingement surface is comparable to or greater than that of the helium impingement surface. For given helium and water temperatures, the heat flux values are generally limited by conduction across the outer shell. These initial studies provide guidance on extending this approach to estimating the thermal-hydraulic performance of larger divertor module designs while reducing the challenges associated with studying such designs in the normal heating configuration at their extremely high prototypical temperatures and incident heat fluxes.
Helium-Cooled Black Shroud for Subscale Cryogenic Testing
This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.
A small helium-cooled infrared telescope for Spacelab 2
A helium cooled telescope of 15 cm aperture is being designed and constructed jointly by the University of Arizona, the Smithsonian Astrophysical Observatory and the Marshall Space Flight Center for high sensitivity infrared astronomical observations from Spacelab 2. A focal plane array of ten detectors provide a total field of view of 3 deg and cover the wavelength regions 4.5-8.5, 6-7, 9-16, 18-30 and 80-120 microns. A highly redundant all sky survey will be conducted by repeated scanning of the sky during many orbits of the spacecraft. High redundancy will allow discrimination among variable and constant celestial sources and several types of variable nearby sources. The principal astronomical result of the survey will be the absolute flux measurement of low surface brightness, large scale celestial infrared emissions but it will also extend existing IR sky surveys by a factor of 10 in point source sensitivity. The experiment will also make significant engineering measurements of contaminants in the Shuttle environment, test the technology of storage and utilization of large quantities of superfluid helium in space and test mechanical designs for future infrared telescopes for the Space Shuttle.
Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor
Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.
A large ultrahigh-vacuum environmental chamber with liquid-helium-cooled liner.
Ultrahigh vacuum chamber with liquid-helium-cooled liner for space environment simulation
Testing of Helium Cooled Metal Molybdenum Disk Target System
NorthStar Medical Radioisotopes LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through a photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess as high a tensile strength as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and the high thermal stress from beam heating.
A large ultra high vacuum environmental chamber with liquid helium cooled walls
Ultrahigh vacuum space simulator with liquid helium-cooled walls
Freeze range of a condensing gas propagating in a liquid helium-cooled tube
Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is crucial for maintaining the operational safety of these facilities. Previous experimental investigations on nitrogen gas propagation in both normal liquid helium (He I) and superfluid helium (He II) cooled copper tubes unveiled a nearly exponential deceleration of the gas propagation. A comprehensive theoretical model incorporating gas dynamics, heat transfer, and condensation mechanisms has been developed, which effectively reproduces various key experimental observations. An intriguing phenomenon uncovered in our model simulation is that the gas propagation appears to nearly stop beyond a certain distance from the location where condensation starts. We refer to this distance as the freeze range. In this paper, we present our systematic study of the freeze range at various inlet mass fluxes and tube diameters. We show that the results can be well described by a simple correlation. The underlying physical mechanism that supports this useful correlation is explained. Knowing the freeze range may allow accelerator engineers to develop protocols for controlling frost-layer contamination in the beamline tubes, which is of great practical importance.
A large ultrahigh-vacuum environmental chamber with liquid-helium-cooled liner.
Large ultrahigh-vacuum environmental chamber with liquid-helium-cooled liner for space simulation
A liquid helium cooled Fabry-Perot infrared spectrometer
A liquid-helium-cooled Fabry-Perot infrared spectrometer offering excellent performance in the middle infrared range has been constructed and tested. The spectrometer is based on newly developed superconducting actuators which control the alignment and tuning at 4.2 K with virtually no power dissipation within the instrument. Depending on the availability of high-quality etalons, this type of spectrometer should be useful in a wide range of infrared astronomical spectroscopy applications.
Testing of Helium-Cooled Metal Molybdenum Disk Target
NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.
Deep Burn: Development of Transuranic Fuel for High-Temperature Helium-Cooled Reactors- Monthly Highlights September 2010
The DB Program monthly highlights report for August 2010, ORNL/TM-2010/184, was distributed to program participants by email on September 17. This report discusses: (1) Core and Fuel Analysis - (a) Core Design Optimization in the HTR (high temperature helium-cooled reactor) Prismatic Design (Logos), (b) Core Design Optimization in the HTR Pebble Bed Design (INL), (c) Microfuel analysis for the DB HTR (INL, GA, Logos); (2) Spent Fuel Management - (a) TRISO (tri-structural isotropic) repository behavior (UNLV), (b) Repository performance of TRISO fuel (UCB); (3) Fuel Cycle Integration of the HTR (high temperature helium-cooled reactor) - Synergy with other reactor fuel cycles (GA, Logos); (4) TRU (transuranic elements) HTR Fuel Qualification - (a) Thermochemical Modeling, (b) Actinide and Fission Product Transport, (c) Radiation Damage and Properties; (5) HTR Spent Fuel Recycle - (a) TRU Kernel Development (ORNL), (b) Coating Development (ORNL), (c) Characterization Development and Support, (d) ZrC Properties and Handbook; and (6) HTR Fuel Recycle - (a) Graphite Recycle (ORNL), (b) Aqueous Reprocessing, (c) Pyrochemical Reprocessing METROX (metal recovery from oxide fuel) Process Development (ANL).