Search NASA⌕ Search

SEARCH · Search NASA

Results for “Helium-3 superfluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Statistics and sensitivity of axion wind detection with the homogeneous precession domain of superfluid helium-3

The homogeneous precession domain (HPD) of superfluid He 3 has recently been identified as a detection medium which might provide sensitivity to the axion-nucleon coupling g a N N competitive with, or surpassing, existing experimental proposals. In this work, we make a detailed study of the statistical and dynamical properties of the HPD system in order to make realistic projections for a full-fledged experimental program. We include the effects of clock error and measurement error in a concrete readout scheme using superconducting qubits and quantum metrology. This work also provides a more general framework to describe the statistics associated with the axion gradient coupling through the treatment of a transient resonance with a nonstationary background in a time-series analysis. Incorporating an optimal data-taking and analysis strategy, we project a sensitivity approaching g a N N ∼ 10 − 12 GeV − 1 across a decade in axion mass. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrable model of topological SO(5) superfluidity

Assisted by general symmetry arguments and a many-body invariant, we introduce a phase of matter that constitutes a topological SO(5) superfluid. Key to this finding is the realization of an exactly solvable model that displays some similarities with a minimal model of superfluid 3 He. We study its quantum phase diagram and correlations, and find exotic superfluid as well as metallic phases in the repulsive sector. At the critical point separating trivial and nontrivial superfluid phases, our Hamiltonian reduces to the globally SO(5)-symmetric Gaudin model with a degenerate ground manifold that includes quartet states. Most importantly, the exact solution permits uncovering of an interesting non-pair-breaking mechanism for superfluids subject to external magnetic fields. Furthermore, nonintegrable modifications of our model lead to a strong-coupling limit of our metallic phase with a ground-state manifold that shows an extensive entropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detector Assembly and the Ultralow-Temperature Refrigerator for XRS

The X-ray spectrometer (XRS) on the Japanese Astro-E Spacecraft is the first ultra low temperature space borne instrument. The system utilizes a 900g Ferric Ammonium Alum (FAA) Adiabatic Demagnetization Refrigerator (ADR) with a helium-3 gas gap heat switch to cool the detector assembly to 0.060K. The system operates in a "single shot" configuration allowing the system to remain at its operating temperature for about 40 hours in the lab. The on-orbit performance is expected to be about 35 hours with a 97% duty cycle. The detector assembly for XRS consists of a 32 channel microcalorimeter array bias electronics, thermometry, and an anti-coincidence detector that are attached to the cold stage of the ADR. To thermally Isolate the detector system from the superfluid helium reservoir, the detector system is suspended by Kevlar cords and electrical connection in made by L30, 17-micron diameter, tensioned NbTi leads. The detectors are read out in a source-follower arrangement using FET amplifiers operating at 130K mounted in multiply-thermally-isolated assemblies that also use Kevlar and stainless steel wiring. The design and thermal performance of this system will be discussed and compared to the theoretical limits.

Porter, F. S.↗

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aggregation of solutes in bosonic versus fermionic quantum fluids

Quantum fluid droplets made of helium-3 ( 3 He) or helium-4 ( 4 He) isotopes have long been considered as ideal cryogenic nanolabs, enabling unique ultracold chemistry and spectroscopy applications. The droplets were believed to provide a homogeneous environment in which dopant atoms and molecules could move and react almost as in free space but at temperatures close to absolute zero. Here, we report ultrafast x-ray diffraction experiments on xenon-doped 3 He and 4 He nanodroplets, demonstrating that the unavoidable rotational excitation of isolated droplets leads to highly anisotropic and inhomogeneous interactions between the host matrix and enclosed dopants. Superfluid 4 He droplets are laced with quantum vortices that trap the embedded particles, leading to the formation of filament-shaped clusters. In comparison, dopants in 3 He droplets gather in diffuse, ring-shaped structures along the equator. The shapes of droplets carrying filaments or rings are direct evidence that rotational excitation is the root cause for the inhomogeneous dopant distributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A review of the NASA/OAST cryogenic coolers technology program

Low and ultra low temperature cryogenic cooler systems for future space missions include mechanical, solid cryogen, gas adsorption, superfluid helium, helium-3, and magnetic (adiabatic demagnetization) coolers. Operating lifetimes required vary from a few weeks for a Shuttle/Spacelab mission to as long as nine years for missions to the outer planets. Temperature requirements vary from tens to tenths of kelvin. At the higher temperature, cooling loads for detectors, instruments and associated shields may be as high as 15 watts. The general requirements for low and ultra low temperature and techniques that can be employed to achieve these temperatures at expected heat loads are discussed. The NASA Centers involved in the R & T efforts and the type of cooler systems on which they are focusing their effort are considered as well as the thrust of R & T effort for each cooler type. Projected missions that will use the technology are identified.

Lundholm, J. G., Jr.↗

NASA low and ultralow temperature cryogenic cooler systems for space missions

The paper describes the NASA research program to provide low and ultralow temperature cryogenic cooler systems for future space missions. These include mechanical, solid cryogen, superfluid helium, helium-3, and helium-3/helium-4 dilution coolers, and all systems must function in the zero gravity environment of space. The temperatures produced range from tens of kelvin down to a few millikelvin; at higher temperatures cooling loads for sensors or detectors and associated sun shields may range up to a few watts. At the ultralow temperature end, cooling loads must be limited to tens of microwatts.

Lundholm, J. G., Jr.↗

A helium-3/helium-4 dilution cryocooler for operation in zero gravity

This research effort covered the development of He-3/He-4 dilution cryocooler cycles for use in zero gravity. The dilution cryocooler is currently the method of choice for producing temperatures below 0.3 Kelvin in the laboratory. However, the current dilution cryocooler depends on gravity for their operation, so some modification is required for zero gravity operation. In this effort, we have demonstrated, by analysis, that the zero gravity dilution cryocooler is feasible. We have developed a cycle that uses He-3 circulation, and an alternate cycle that uses superfluid He-4 circulation. The key elements of both cycles were demonstrated experimentally. The development of a true 'zero-gravity' dilution cryocooler is now possible, and should be undertaken in a follow-on effort.

Hendricks, John B.↗