Search NASASearch

SEARCH · Search NASA

Results for “Helium-4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Helium-4 gravitational form factors: Exchange currents

We evaluate the leading exchange corrections to the helium-4 gravitational form factors (GFFs) to momenta of the order of the nucleon mass. We use both the K-harmonic method with simple pair nucleon potential, and a Jastrow trial function using the Argonne 𝑣 14 potential, to evaluate the helium-4 GFFs. The exchange current contributions include the pair interaction, plus the seagull and the pion exchange interactions, modulo the recoil corrections. To estimate the off-shellness of the pion nucleon coupling in this momenta range, we discuss the results using either the pseudoscalar (PS) or pseudovector (PV) pion-nucleon couplings. When the PV coupling is used, the pair diagram contribution is higher order in the nonrelativistic expansion. The results for the helium-4 A-GFF are comparable to those given by the impulse approximation, especially for the PS coupling using both the K-harmonic method and variational method. The exchange current contributions with the PS coupling for the charge form factor of helium-4, yield better agreement with the existing data over a broad range of momenta, especially when the Argonne 𝑣 14 potential including the D-wave admixture is used.

A ≤ 5

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]

Thermophysical properties of helium-4 from 4 to 3000 R with pressures to 15000 psia

Data on many of the properties of helium commonly used in engineering calculations are compiled over as wide a temperature and pressure range as is practical. These properties are presented in a form which is convenient to the engineer. All of these properties have been critically evaluated and represent the best values for that property at this time.

Mccarty, R. D.

Threshold photoproduction of 𝐽/Ψ off light nuclei

Here, we analyze threshold photoproduction of heavy mesons off a deuteron and helium-4, using the QCD factorization method. Assuming large skewness, the production amplitude is dominated by the leading twist-2 gluonic energy-momentum tensor. We use our recent results for the gluonic gravitational form factors of light nuclei in the impulse approximation, to estimate the differential cross sections for 𝐽/Ψ production off a deuteron and helium-4 at current electron facilities.

few-body systems

Helium Release During Fracture and Granular Fragmentation of Rocks

Geogenic Helium-4 ( 4 He) in-situ increases locally in regions of large deformation generated naturally or anthropogenically. This gas release by deformation is a potential geochemical precursor signal for subsurface deformation. To evaluate the applicability of 4 He degassing for correlating deformation in different lithologies, we conducted high force crush tests, up to 97,800 N axial load, to assess the total 4 He released during fragmentation of the rocks. We observed that the highest 4 He released occurred in the sedimentary rocks and that release correlated strongly with lithologic age and U/Th content. Microstructural changes of the pre- and post-test rocks indicate that the degree of grain size reduction relates directly to the total 4 He released during crushing. The range of in-place 4 He was calculated based XRF measurements of uranium and thorium in each lithology, with the results indicating that the majority of the trapped 4 He was not released. However, the 4 He released by deformation depended upon how the each rock deformed during deformation and the degree of grain size reduction. We postulate that 4 He precursor signals can be used to understand subsurface deformation only if geomechanical and geochemical conditions for 4 He enrichment in a lithology are met.

Deformation signals

New bounds on heavy QCD axions from big bang nucleosynthesis

We study big bang nucleosynthesis (BBN) constraints on heavy QCD axions. BBN offers a powerful probe of new physics that modifies the neutron-to-proton ratio during the process, thanks to the precisely measured primordial Helium-4 abundance. A heavy QCD axion provides an attractive target for this probe, because not only is it a well-motivated hypothetical particle by the strong 𝐶⁢𝑃 problem, but also it dominantly decays to hadrons if kinematically allowed. A range of its lifetime is thus excluded where the hadronic decays would significantly alter the neutron-to-proton ratio. We compute axion-induced modification of the neutron-to-proton ratio, and obtain robust upper bounds on the axion lifetimes, as low as 0.017 s for the axion mass higher than 300 MeV. Remarkably, this is stronger than projected future cosmic microwave background bounds via 𝑁 eff . Our bounds are largely insensitive to uncertainties in hadronic cross sections and the axion’s branching fractions into various hadrons, as well as to the precise value of the initial axion abundance. We also incorporate, for the first time, several key improvements, such as scattering processes by energetic 𝐾 𝐿 and secondary hadrons, that can also be important for studying general hadronic injections during BBN, not limited to those from axion decays.

Axions

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)

SpinQuest Polarized Target System

The SpinQuest experiment at Fermilab uses a solid-state polarized ammonia target held at a magnetic field of 5 T, immersed in liquid helium-4, which is held at approximately 1K by the evaporation refrigerator. The refrigerator provides the required cooling power during the dynamic nuclear polarization (DNP) process and the high intensity interaction with the 120 GeV proton beam from the Fermilab main injector. The refrigerator was designed in compliance with the American Society of Mechanical Engineers (ASME) to operate safely at Fermilab. The high pumping capacity ($17,000 \:m^3/h$) roots stack provides the required pumping speed during DNP production data taking and a custom-made radiation hard flow control valve regulates the refrigerator temperature during the thermal equilibrium calibration measurements. The frequency of the microwave generator, an Extended Interaction Oscillator (EIO), is automated to keep the maximum polarization while the (Nuclear Magnetic Resonance) NMR system continuously measures the polarization of the target material. In this talk, an overview of the SpinQuest polarized target system will be presented as well as a brief report of recent commissioning activities and target performance during the early production runs in 2024.

Bandara, Vibodha [Colombo U.]

Elastic scattering of 600-MeV protons from H, D, He-3, and He-4.

Study of the elastic scattering of 600-MeV protons from light nuclei. Differential cross sections have been obtained for the scattering of protons from hydrogen, deuterium, helium-3, and helium-4. Polarization was measured for deuterium and He-4 nuclei. The p-p cross-section data are in excellent agreement with the predictions from the Livermore phase shifts. Small-angle p-D, p-He-3 elastic scattering data are compared with calculations based on the multiple-scattering theories of Watson and Glauber.

Boschitz, E. T.

Solar flare accelerated isotopes of hydrogen and helium

Measurements of solar flare hydrogen, deuterium, tritium, helium-3, and helium-4 in the energy range approximately 10 to 50 MeV per nucleon obtained with instrumentation on the IMP-4 and IMP-5 satellites are reported and studies based on these results which place several constraints on theories of solar flare particle acceleration are discussed. A brief review of previous work and the difficulties in studying the rare isotopes of hydrogen and helium is also included. Particular emphasis is placed on the fact that the information to be obtained from the solar flare products of high energy interactions is not available through either solar wind observations where both the acceleration mechanism and the coronal source of the nuclear species are different, or optical measurements of solar active regions.

Anglin, J. D.

Magnetospheric particle composition experiment

Thin foils of aluminum and platinum were mounted on the exterior of the Skylab spacecraft where they were bombarded by particles that penetrate to the 400-km spacecraft altitude, including auroral particles precipitating from the earth magnetosphere. These foils have a high trapping efficiency for both charged and neutral particles above 1 keV and a decreasing but appreciable efficiency below that energy. Some sections of the foils were double layered to obtain an estimate of the energy of the entrapped particles. The foils were retrieved and returned for analysis in an ultrahigh-vacuum mass spectrometer. So far, the noble gas components of the entrapped particles have been analyzed in selected sections of two foils. Helium-4, helium-3, neon-20, and neon-22 have been detected.

Geiss, J.

A small gas inlet system for orbital mass-spectrometer calibrations

A gas inlet system is described for generating precise gas pressures that are to be used as calibration references for the mass spectrometers aboard the dual air density Explorer satellites. This gas inlet system was developed as an inflight calibration technique in which a known amount of onboard gas is released in the satellite cavity and is detected by the mass spectrometer. Although several flight mass spectrometer experiments have been proposed, none make use of the inflight calibration technique described in this report. Laboratory measurements and calibration of the metering leak technique for the gas inlet systems are discussed. The systems tested have metering leak rates between 2 and 4 microliters/sec at 298 K for argon-40, and they produce molecular flow up to 100 torr, which is the highest test pressure in this experiment. Test data show that metering leak rates are reproducible within 1 percent of established means for helium-3, helium-4, and argon-40.

Smith, A.

Evaluation of composite bolometers at 0.4 Kelvin

Composite bolometer structures have provided the most sensitive IR detectors for operation at helium-4 temperatures of 1.5K. Below 1.5K the electrical and thermal properties change significantly and the performance characteristics cannot be accurately extrapolated for composite bolometers at helium-3 temperatures of 0.4K. The paper deals with experimentally assessed performance of composite bolometers at 0.4K. It is found that sensitivity estimates derived from electrical or load curve properties can overestimate the responsivity to radiation by several orders of magnitude depending upon a particular material behavior. For many near-millimeter applications background power levels are several nanowatts and the associated photon noise plus Johnson and phonon noise components impose a fundamental detection limit of about 5 x 10 to the -15thW/Hz to the -1/2. We have successfully fabricated composite bolometers which at 0.4 K and millimeter wavelengths achieve a noise equivalent power of 7 x 10 to the -15thW/Hz to the -1/2 coupled with a large absorbing area (0.3 sq cm) and a fast response time (2 msec.).

El-Ataway, S.

Helium on Venus - Implications for uranium and thorium

Helium is removed at an average rate of 10 to the 6th atoms per square centimeter per second from Venus's atmosphere by the solar wind following ionization above the plasmapause. The surface source of helium-4 on Venus is similar to that on earth, suggesting comparable abundances of crustal uranium and thorium.

Prather, M. J.