Search NASASearch

SEARCH · Search NASA

Results for “Helium-4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Helium-4 gravitational form factors: Exchange currents

We evaluate the leading exchange corrections to the helium-4 gravitational form factors (GFFs) to momenta of the order of the nucleon mass. We use both the K-harmonic method with simple pair nucleon potential, and a Jastrow trial function using the Argonne 𝑣 14 potential, to evaluate the helium-4 GFFs. The exchange current contributions include the pair interaction, plus the seagull and the pion exchange interactions, modulo the recoil corrections. To estimate the off-shellness of the pion nucleon coupling in this momenta range, we discuss the results using either the pseudoscalar (PS) or pseudovector (PV) pion-nucleon couplings. When the PV coupling is used, the pair diagram contribution is higher order in the nonrelativistic expansion. The results for the helium-4 A-GFF are comparable to those given by the impulse approximation, especially for the PS coupling using both the K-harmonic method and variational method. The exchange current contributions with the PS coupling for the charge form factor of helium-4, yield better agreement with the existing data over a broad range of momenta, especially when the Argonne 𝑣 14 potential including the D-wave admixture is used.

A ≤ 5

Multi-Differential Semi-Inclusive Charged-Current Muon Neutrino Cross Sections on Helium-4 in MINERvA and the Helium-to-CH Target Cross Section Ratio

A comprehensive international effort has been underway to elucidate the properties and behaviors of neutrinos. A major source of systematic uncertainties in studying neutrino-induced interactions comes from neutrino-nucleus cross-section models, highlighting the need for more precise statistical measurements. MINERvA, an on-axis neutrino-nucleus scattering experiment located at the Fermi National Accelerator Laboratory, was established to produce neutrino cross-section measurements with many different nuclei. The helium target is the lightest nucleus to be measured by MINERvA. Using the NuMI medium energy muon neutrino data set, we present preliminary results and summarize the extraction of the charged current (CC) muon neutrino - helium-4 semi-inclusive ($\nu_{\mu}$+$^{4}\textrm{He}$$\rightarrow$$\mu^{-}$+N$\pi$+M$\textit{p}$) multi-differential cross-section extraction as a function of transverse ($P_{T}$) and longitudinal ($P_{L}$) muon momentum with respect to the neutrino beamline. We define the final state topology as CC-N$\pi$M$\textit{p}$, with at least two reconstructed tracks: a muon and a combination of N protons and M pions, where $N + M > 0$. To probe the dependence on the size of the nucleus in neutrino-induced interaction phenomena we present a differential cross-section ratio of helium-4 to MINERvA's hydrocarbon target (\textrm{CH}) as a function of transverse muon momentum.

Nguyen, Christian

An ASME-Compliant Helium-4 Evaporation Refrigerator for the SpinQuest Experiment

This paper presents the design, safety basis, and commissioning results of a 1 K liquid helium-4 (4He) evaporation refrigerator developed for the Fermilab SpinQuest Experiment (E1039). The system represents the first high power helium evaporation refrigerator operated in a fixed target scattering experiment at Fermilab and was engineered to comply with the Fermilab ES&H Manual (FESHM) requirements governing pressure vessels, piping, cryogenic systems, and vacuum vessels. The design is mapped to ASME B31.3 (Process Piping) and the ASME Boiler and Pressure Vessel Code (BPVC) for pressure boundary integrity and overpressure protection, with documented compliance to FESHM Chapters 5031 (Pressure Vessels), 5031.1 (Piping Systems), and 5033 (Vacuum Vessels). This work documents the methodology used to reach compliance and approval for the 4He evaporation refrigerator at Fermilab which the field lacks. Design considerations specific to the high radiation target-cave environment including remotely located instrumentation approximately 20 m from the cryostat are summarized, together with the relief-system sizing methodology used to accommodate transient heat loads from dynamic nuclear polarization microwaves and the high-intensity proton beam. Commissioning data from July 2024 confirms that the system satisfies all thermal performance and safety objectives.

Roberts, Jordan D. [Virginia U.]

Threshold photoproduction of 𝐽/Ψ off light nuclei

Here, we analyze threshold photoproduction of heavy mesons off a deuteron and helium-4, using the QCD factorization method. Assuming large skewness, the production amplitude is dominated by the leading twist-2 gluonic energy-momentum tensor. We use our recent results for the gluonic gravitational form factors of light nuclei in the impulse approximation, to estimate the differential cross sections for 𝐽/Ψ production off a deuteron and helium-4 at current electron facilities.

few-body systems

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Helium Release During Fracture and Granular Fragmentation of Rocks

Geogenic Helium-4 ( 4 He) in-situ increases locally in regions of large deformation generated naturally or anthropogenically. This gas release by deformation is a potential geochemical precursor signal for subsurface deformation. To evaluate the applicability of 4 He degassing for correlating deformation in different lithologies, we conducted high force crush tests, up to 97,800 N axial load, to assess the total 4 He released during fragmentation of the rocks. We observed that the highest 4 He released occurred in the sedimentary rocks and that release correlated strongly with lithologic age and U/Th content. Microstructural changes of the pre- and post-test rocks indicate that the degree of grain size reduction relates directly to the total 4 He released during crushing. The range of in-place 4 He was calculated based XRF measurements of uranium and thorium in each lithology, with the results indicating that the majority of the trapped 4 He was not released. However, the 4 He released by deformation depended upon how the each rock deformed during deformation and the degree of grain size reduction. We postulate that 4 He precursor signals can be used to understand subsurface deformation only if geomechanical and geochemical conditions for 4 He enrichment in a lithology are met.

Deformation signals

Isotope effects and Alfvén eigenmode stability in JET H, D, T, DT, and He plasmas

While much about Alfvén eigenmode (AE) stability has been explored in previous and current tokamaks, open questions remain for future burning plasma experiments, especially regarding exact stability threshold conditions and related isotope effects; the latter, of course, requiring good knowledge of the plasma ion composition. In the JET tokamak, eight in-vessel antennas actively excite stable AEs, from which their frequencies, toroidal mode numbers, and net damping rates are assessed. The effective ion mass can also be inferred using measurements of the plasma density and magnetic geometry. Thousands of AE stability measurements have been collected by the Alfvén Eigenmode Active Diagnostic in hundreds of JET plasmas during the recent Hydrogen, Deuterium, Tritium, DT, and Helium-4 campaigns. In this novel AE stability database, spanning all four main ion species, damping is observed to decrease with increasing Hydrogenic mass, but increase for Helium, a trend consistent with radiative damping as the dominant damping mechanism. These data are important for confident predictions of AE stability in both non-nuclear (H/He) and nuclear (D/T) operations in future devices. In particular, if radiative damping plays a significant role in overall stability, some AEs could be more easily destabilized in D/T plasmas than their H/He reference pulses, even before considering fast ion and alpha particle drive. Active MHD spectroscopy is also employed on select HD, HT, and DT plasmas to infer the effective ion mass, thereby closing the loop on isotope analysis and demonstrating a complementary method to typical diagnosis of the isotope ratio.

Alfvén eigenmodes

New bounds on heavy QCD axions from big bang nucleosynthesis

We study big bang nucleosynthesis (BBN) constraints on heavy QCD axions. BBN offers a powerful probe of new physics that modifies the neutron-to-proton ratio during the process, thanks to the precisely measured primordial Helium-4 abundance. A heavy QCD axion provides an attractive target for this probe, because not only is it a well-motivated hypothetical particle by the strong 𝐶⁢𝑃 problem, but also it dominantly decays to hadrons if kinematically allowed. A range of its lifetime is thus excluded where the hadronic decays would significantly alter the neutron-to-proton ratio. We compute axion-induced modification of the neutron-to-proton ratio, and obtain robust upper bounds on the axion lifetimes, as low as 0.017 s for the axion mass higher than 300 MeV. Remarkably, this is stronger than projected future cosmic microwave background bounds via 𝑁 eff . Our bounds are largely insensitive to uncertainties in hadronic cross sections and the axion’s branching fractions into various hadrons, as well as to the precise value of the initial axion abundance. We also incorporate, for the first time, several key improvements, such as scattering processes by energetic 𝐾 𝐿 and secondary hadrons, that can also be important for studying general hadronic injections during BBN, not limited to those from axion decays.

Axions

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)

Evaluation of Getters for Helium Purification

• Helium-3 is a vital commodity in both medical and defense applications • Ultra-low cryogenic coolant (MRI imaging, etc.) • Neutron detectors • Being investigated as possible fusion fuel • Managed and distributed by DOE-OS • New PDRD project exploring helium isotope separation • Limited supply • Only available from tritium decay • Prohibitively difficult to separate from helium-4 • SRS Tritium Facility provides a steady source

Angelette, Lucas M.

SpinQuest Polarized Target System

The SpinQuest experiment at Fermilab uses a solid-state polarized ammonia target held at a magnetic field of 5 T, immersed in liquid helium-4, which is held at approximately 1K by the evaporation refrigerator. The refrigerator provides the required cooling power during the dynamic nuclear polarization (DNP) process and the high intensity interaction with the 120 GeV proton beam from the Fermilab main injector. The refrigerator was designed in compliance with the American Society of Mechanical Engineers (ASME) to operate safely at Fermilab. The high pumping capacity ($17,000 \:m^3/h$) roots stack provides the required pumping speed during DNP production data taking and a custom-made radiation hard flow control valve regulates the refrigerator temperature during the thermal equilibrium calibration measurements. The frequency of the microwave generator, an Extended Interaction Oscillator (EIO), is automated to keep the maximum polarization while the (Nuclear Magnetic Resonance) NMR system continuously measures the polarization of the target material. In this talk, an overview of the SpinQuest polarized target system will be presented as well as a brief report of recent commissioning activities and target performance during the early production runs in 2024.

Bandara, Vibodha [Colombo U.]

Characterizing Al quasiparticle diffusion using a positionable laser (Final Technical Report)

This Career Award accomplished most of its goals, in demonstrating for the first time a low- threshold nuclear recoil detector based on the quantum evaporation of helium-4. Through this work, we trained several PhD students and evolved this niche R&D topic into a central pillar of the DOE-funded TESSERACT project, which now plans to take underground helium data in 2028.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS