Model-based approach to investigate equipment-induced error in pressure-waveform derived hemodynamic measurements

Advanced hemodynamic monitoring systems have provided less invasive methods for estimating pressure-derived measurements such as pressure-derived cardiac output (CO) measurements. These devices apply algorithms to arterial pressure waveforms recorded via pressure recording components that transmit the pressure signal to a pressure monitor. While standards have been developed for pressure monitoring equipment, it is unclear how the equipment-induced error can affect secondary measurements from pressure waveforms. We propose an approach for modelling different components of a pressure monitoring system and use this model-based approach to investigate the effect of different pressure recording configurations on pressure-derived hemodynamic measurements. The proposed model-based approach is a three-step process. (1) Modelling the response of pressure recording components using bench tests; (2) verifying the identified models through nonparametric equivalence tests; and (3) assessing the effects of pressure recording components on pressure-derived measurements. To delineate the application of this approach, we performed a series of model-based analyses to quantify the combined effect of a wide range of tubing configurations with various damping ratios and natural frequencies and monitors with different bandwidths on pressure waveforms and CO measurements by six pulse contour algorithms. Model-based results show the error in pressure-derived CO measurements because of tubing configurations with different natural frequencies and damping ratios. Tubing configurations with low natural frequencies (<23 Hz) altered characteristics of pressure waveforms in a way that affected the CO measurement, some by as much as 20%. Our method can serve as a tool to quantify the performance of pressure recording systems with different dynamic properties. In conclusion, this approach can be applied to investigate the effects of physiologic signal recording configurations on various pressure-derived hemodynamic measurements.

42 ENGINEERING↗

Magnetic resonance flow velocity and temperature mapping of a shape memory polymer foam device

Background: Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheterdelivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. Methods: A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Results: Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Conclusions: Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

42 ENGINEERING↗

Magnetic Resonance Flow Velocity and Temperature Mapping of a Shape Memory Polymer Foam Device

Interventional medical devices based on thermally responsive shape memory polymer (SMP) are under development to treat stroke victims. The goals of these catheter-delivered devices include re-establishing blood flow in occluded arteries and preventing aneurysm rupture. Because these devices alter the hemodynamics and dissipate thermal energy during the therapeutic procedure, a first step in the device development process is to investigate fluid velocity and temperature changes following device deployment. A laser-heated SMP foam device was deployed in a simplified in vitro vascular model. Magnetic resonance imaging (MRI) techniques were used to assess the fluid dynamics and thermal changes associated with device deployment. Spatial maps of the steady-state fluid velocity and temperature change inside and outside the laser-heated SMP foam device were acquired. Though non-physiological conditions were used in this initial study, the utility of MRI in the development of a thermally-activated SMP foam device has been demonstrated.

42 ENGINEERING↗

Shear stress induces cell apoptosis via a c-Src-phospholipase D-mTOR signaling pathway in cultured podocytes

The glomerular capillary wall, composed of endothelial cells, the glomerular basement membrane and the podocytes, is continually subjected to hemodynamic force arising from tractional stress due to blood pressure and shear stress due to blood flow. Exposure of glomeruli to abnormal hemodynamic force such as hyperfiltration is associated with glomerular injury and progressive renal disease, and the conversion of mechanical stimuli to chemical signals in the regulation of the process is poorly understood in podocytes. By examining DNA fragmentation, apoptotic nuclear changes and cytochrome c release, we found that shear stress induced cell apoptosis in cultured podocytes. Meanwhile, podocytes exposed to shear stress also stimulated c-Src phosphorylation, phospholipase D (PLD) activation and mammalian target of rapamycin (mTOR) signaling. Using the antibodies against c-Src, PLD{sub 1}, and PLD{sub 2} to perform reciprocal co-immunoprecipitations and in vitro PLD activity assay, our data indicated that c-Src interacted with and activated PLD{sub 1} but not PLD{sub 2}. The inhibition of shear stress-induced c-Src phosphorylation by PP{sub 2} (a specific inhibitor of c-Src kinase) resulted in reduced PLD activity. Phosphatidic acid, produced by shear stress-induced PLD activation, stimulated mTOR signaling, and caused podocyte hypertrophy and apoptosis.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of Heterogeneous GPU Programming Frameworks for Hemodynamic Simulations

Preparing for the deployment of large scientific and engineering codes on upcoming exascale systems with GPU-dense nodes is made challenging by the unprecedented diversity of device architectures and heterogeneous programming models. In this work, we evaluate the process of porting a massively parallel, fluid dynamics code written in CUDA to SYCL, HIP, and Kokkos with a range of backends, using a combination of automated tools and manual tuning. We use a proxy application along with a custom performance model to inform the results and identify additional optimization strategies. At scale performance of the programming model implementations are evaluated on pre-production GPU node architectures for Frontier and Aurora, as well as on current NVIDIA device-based systems Summit and Polaris. Real-world workloads representing 3D blood flow calculations in complex vasculature are assessed. Our analysis highlights critical trade-offs between code performance, portability, and development time.

Martin, Aristotle↗

Multimodality Imaging for the Assessment of Pericardial Diseases

Purpose of Review: The diagnosis of pericardial syndromes, while occasionally straightforward, includes a wide range of pathologies and is often a well-recognized clinical challenge. The aim of this review is to highlight the key role of the various imaging modalities for the diagnosis and management of the spectrum of pericardial diseases. Recent Findings: Cardiac imaging has become an integral part of the diagnostic process often beginning with echocardiography and supported by advanced imaging modalities including computed tomography, magnetic resonance imaging, and positive emission tomography. These modalities go beyond the simple identification of the pericardium, to identifying increased pericardial thickness, active pericardial edema and inflammation, and its effect on cardiac hemodynamics. Summary: Multimodality imaging has significantly facilitated the diagnosis and long-term management of patients with pericardial diseases. The role of these imaging modalities in overall prognosis and prevention remains to be investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Smoking, COPD and 3-Nitrotyrosine Levels of Plasma Proteins

BACKGROUND: Nitric oxide is a physiologically regulator of endothelial function and hemodynamics. Oxidized products of nitric oxide can form nitrotyrosine, which is a marker of nitrative stress. Cigarette smoking decreases exhaled nitric oxide, and the underlying mechanism may be important in the cardiovascular toxicity of cigarette smoke, although it is not clear if this effect results from decreased nitric oxide production or oxidation of nitric oxide to reactive, nitrating, species. These processes would be expected to have opposite effects on nitrotyrosine levels, a marker of nitrative stress. OBJECTIVE: In this study, we determine the effects of smoking and chronic obstructive pulmonary disease (COPD) on circulating levels of nitrotyrosine, and thereby gain insight into the processes regulating nitrotyrosine formation. METHODS: A custom antibody microarray platform was used to analyze the levels of 3-nitrotyrosine modifications on 24 proteins in plasma. Plasma samples from 458 individuals were analyzed. RESULTS: Nitrotyrosine levels in circulating proteins were uniformly reduced in smokers but increased in COPD patients. We also observed a persistent suppression of nitrotyrosine in former smokers. CONCLUSIONS: Smoking broadly suppresses the levels of 3-nitrotyrosine in plasma proteins, suggesting that cigarette smoke suppresses endothelial nitric oxide production. In contrast, the increase in nitrotyrosine levels in COPD patients most likely results from inflammatory processes. This study provides the first evidence that smoking has irreversible effects on endothelial production of nitric oxide, and provides insight into how smoking could induce a loss of elasticity in the vasculature and a long-term increase in the risk of cardiovascular disease.

59 BASIC BIOLOGICAL SCIENCES↗

Poster — Thur Eve — 44: Linearization of Compartmental Models for More Robust Estimates of Regional Hemodynamic, Metabolic and Functional Parameters using DCE-CT/PET Imaging

Quantitative analysis of dynamic positron emission tomography (PET) data usually involves minimizing a cost function with nonlinear regression, wherein the choice of starting parameter values and the presence of local minima affect the bias and variability of the estimated kinetic parameters. These nonlinear methods can also require lengthy computation time, making them unsuitable for use in clinical settings. Kinetic modeling of PET aims to estimate the rate parameter k{sub 3}, which is the binding affinity of the tracer to a biological process of interest and is highly susceptible to noise inherent in PET image acquisition. We have developed linearized kinetic models for kinetic analysis of dynamic contrast enhanced computed tomography (DCE-CT)/PET imaging, including a 2-compartment model for DCE-CT and a 3-compartment model for PET. Use of kinetic parameters estimated from DCE-CT can stabilize the kinetic analysis of dynamic PET data, allowing for more robust estimation of k{sub 3}. Furthermore, these linearized models are solved with a non-negative least squares algorithm and together they provide other advantages including: 1) only one possible solution and they do not require a choice of starting parameter values, 2) parameter estimates are comparable in accuracy to those from nonlinear models, 3) significantly reduced computational time. Our simulated data show that when blood volume and permeability are estimated with DCE-CT, the bias of k{sub 3} estimation with our linearized model is 1.97 ± 38.5% for 1,000 runs with a signal-to-noise ratio of 10. In summary, we have developed a computationally efficient technique for accurate estimation of k{sub 3} from noisy dynamic PET data.

60 APPLIED LIFE SCIENCES↗

The Amplatzer Vascular Plug: A Review of the Device and its Clinical Applications

The Amplatzer Vascular Plug (AVP) is an established embolic device that can be an excellent alternative to coils or detachable balloons to embolize medium to large vessels with high flow. The device is easy to use and can be precisely deployed in the target vessel with high resistance to migration and a low recanalization rate. The technical success of this device is high, indications for use are expanding, and no absolute contraindications have been reported. Since its introduction, the AVP has grown from a single device to a group of 4 models (AVP, AVP II, AVP III, and AVP 4). Each model has a unique design and features that fit different vascular anatomies, hemodynamic situations, and clinical scenarios. Therefore, the new models cannot simply be treated as replacements for older ones. Unpredictable occlusion time remains a major shortcoming for the new models of the AVP. Large vessel size, high flow status, and coagulopathy can prolong the occlusion time, which can offset the cost benefit, reduced procedure time, and reduced radiation dose typically seen with use of the AVP alone. Coils or multiple AVPs can be used to expedite the occlusion process, and large Gelfoam particles also can be used as an adjunct to achieve rapid and reliable occlusion with minimal cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flow characteristics in narrowed coronary bypass graft

Tortuous saphenous vein graft (SVG) hemodynamics was investigated using computational fluid dynamics (CFD) techniques. Computed tomography (CT) technology is used for non-invasive bypass graft assessment 7 days after surgery. CT investigation shown two regions with severe shape remodelling first is an elbow type contortion and second is a severe curvature with tortuous area reduction. In conclusion, the helical flow induced by vessel torsion may stabilize the blood flow in the distal part of the SVG, reducing the flow disturbance and suppressing the flow separation, but in the distal end of the graft, promote the inflammatory processes in the vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

60 APPLIED LIFE SCIENCES↗

Farnesoid-X-receptor expression in monocrotaline-induced pulmonary arterial hypertension and right heart failure

Objective: The farnesoid-X-receptor (FXR) is a metabolic nuclear receptor superfamily member that is highly expressed in enterohepatic tissue and is also expressed in the cardiovascular system. Multiple nuclear receptors, including FXR, play a pivotal role in cardiovascular disease (CVD). Pulmonary arterial hypertension (PAH) is an untreatable cardiovascular system disease that leads to right heart failure (RHF). However, the potential physiological/pathological roles of FXR in PAH and RHF are unknown. We therefore compared FXR expression in the cardiovascular system in PAH, RHF and a control. Methods and results: Hemodynamic parameters and morphology were assessed in blank solution-exposed control, monocrotaline (MCT)-exposed PAH (4 weeks) and RHF (7 weeks) Sprague–Dawley rats. Real-time reverse transcription polymerase chain reaction (real-time RT-PCR), Western blot (WB), immunohistochemistry (IHC) analysis and immunofluorescence (IF) analysis were performed to assess FXR levels in the lung and heart tissues of MCT-induced PAH and RHF rats. In normal rats, low FXR levels were detected in the heart, and nearly no FXR was expressed in rat lungs. However, FXR expression was significantly elevated in PAH and RHF rat lungs but reduced in PAH and RHF rat right ventricular (RV) tissues. FXR expression was reduced only in RHF rat left ventricular (LV) tissues. Conclusions: The differential expression of FXR in MCT-induced PAH lungs and heart tissues in parallel with PAH pathophysiological processes suggests that FXR contributes to PAH. - Highlights: • FXR was expressed in rat lung and heart tissues. • FXR expression increased sharply in the lung tissues of PAH and RHF rats. • FXR expression was reduced in PAH and RHF rat RV tissue. • FXR expression was unaltered in PAH LV but reduced in RHF rat LV tissue. • FXR expression was prominent in the neovascularization region.

60 APPLIED LIFE SCIENCES↗

Toward Smart, Automated Junctional Tourniquets—AI Models to Interpret Vessel Occlusion at Physiological Pressure Points

Hemorrhage is the leading cause of preventable death in both civilian and military medicine. Junctional hemorrhages are especially difficult to manage since traditional tourniquet placement is often not possible. Ultrasound can be used to visualize and guide the caretaker to apply pressure at physiological pressure points to stop hemorrhage. However, this process is technically challenging, requiring the vessel to be properly positioned over rigid boney surfaces and applying sufficient pressure to maintain proper occlusion. As a first step toward automating this life-saving intervention, we demonstrate an artificial intelligence algorithm that classifies a vessel as patent or occluded, which can guide a user to apply the appropriate pressure required to stop flow. Neural network models were trained using images captured from a custom tissue-mimicking phantom and an ex vivo swine model of the inguinal region, as pressure was applied using an ultrasound probe with and without color Doppler overlays. Using these images, we developed an image classification algorithm suitable for the determination of patency or occlusion in an ultrasound image containing color Doppler overlay. Separate AI models for both test platforms were able to accurately detect occlusion status in test-image sets to more than 93% accuracy. In conclusion, this methodology can be utilized for guiding and monitoring proper vessel occlusion, which, when combined with automated actuation and other AI models, can allow for automated junctional tourniquet application.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-05: PET-Guided Delivery Quality Evaluation of Yttrium-90 Microsphere Radioembolizaton for Hepatocellular Carcinoma Patients: The Optimal Sequence of Radioembolizaton and Chemoembolization Treatments

Purpose: Selective-internal-radiation-therapy (SIRT) and transarterial-chemoembolization (TACE) are commonly used for treatment of liver tumors. The use of TACE, which is macroembolic, prior to SIRT may cause hemodynamic changes in tumor vasculature that impair yttrium-90 (90Y) microsphere delivery to the targeted lesions. This work aims to quantify dosimetric tumor coverage using 90Y positron emission tomography (PET) dosimetry after SIRT alone compared to TACE followed by SIRT. Methods: A total of 40 consecutive hepatocellular carcinoma (HCC) SIRT patients who had a post-SIRT 90Y PET/CT scan were evaluated. The patient-specific-3D-dose was reconstructed from the PET images. Patients were categorized into two groups: patients received TACE prior SIRT procedure (n=18) and patient received SIRT alone (n=22). The lesions and liver were delineated by a senior radiologist. We evaluated both the lesion-specific dose-volume-histogram (DVH) and the selectivity index (SI) defined as the ratio of the average dose inside the total lesion(s) and the average dose of the normal liver. The SI values of patients were compared based on whether TACE was previously used. Results: A wide spectrum was observed in the lesion-specific DVH-evaluation and SI appeared to be suitable of evaluating the quality of each SIRT infusion. The average SI of the entire patient group was 3.0, i.e. targeted lesion receiving three times higher dose than normal liver. The average SI was 1.8 for patients who had prior TACE and 3.9 for patients who did not have prior TACE (p=0.008). 85% of the patients with prior TACE demonstrated poor 90Y-microsphere delivery (SI <2) while none demonstrated excellent delivery (SI >4). On the other hand, the incidence SI >4 among patients with no prior TACE was 37%. Conclusion: 3D dose evaluation using post-SIRT PET suggests that 90Y microsphere delivery to liver tumors is impaired among patients who received prior TACE compared to those who receive SIRT alone.

60 APPLIED LIFE SCIENCES↗

Using flow information to support 3D vessel reconstruction from rotational angiography

For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here, we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 deg. . As a standard c-arm can rotate 205 deg., typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗