Evaluating Performance, Power, and Cooling in High Performance Computing (HPC) Data Centers

This chapter explores current research focused on developing our understanding of the interrelationships involved with HPC performance and energy management. The first section explores data center instrumentation, measurement, and performance analysis techniques, followed by a section focusing on work in data center thermal management and resource allocation. This is followed by an exploration of emerging techniques to identify application behavioral attributes that can provide clues and advice to HPC resource and energy management systems for the purpose of balancing HPC performance and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

TUE, a New Energy-Efficiency Metric Applied at ORNL’s Jaguar. In: ISC 2013: Supercomputing. Lecture Notes in Computer Science

The metric, Power Usage Effectiveness (PUE), has been successful in improving energy efficiency of data centers, but it is not perfect. One challenge is that PUE does not account for the power distribution and cooling losses inside IT equipment. This is particularly problematic in the HPC (high performance computing) space where system suppliers are moving cooling and power subsystems into or out of the cluster. This paper proposes two new metrics: ITUE (IT-power usage effectiveness), similar to PUE but “inside” the IT and TUE (total-power usage effectiveness), which combines the two for a total efficiency picture. We conclude with a demonstration of the method, and a case study of measurements at ORNL’s Jaguar system. TUE provides a ratio of total energy, (internal and external support energy uses) and the specific energy used in the HPC. TUE can also be a means for comparing HPC site to HPC site.

data center↗

Development of the Sandia Cooler

This report describes an FY13 effort to develop the latest version of the Sandia Cooler, a breakthrough technology for air-cooled heat exchangers that was developed at Sandia National Laboratories. The project was focused on fabrication, assembly and demonstration of ten prototype systems for the cooling of high power density electronics, specifically high performance desktop computers (CPUs). In addition, computational simulation and experimentation was carried out to fully understand the performance characteristics of each of the key design aspects. This work culminated in a parameter and scaling study that now provides a design framework, including a number of design and analysis tools, for Sandia Cooler development for applications beyond CPU cooling.

97 MATHEMATICS AND COMPUTING↗

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING↗

Parallel Multivariate Spatio-Temporal Clustering of Large Ecological Datasets on Hybrid Supercomputers

A proliferation of data from vast networks of remote sensing platforms (satellites, unmanned aircraft systems (UAS), airborne etc.), observational facilities (meteorological, eddy covariance etc.), state-of-the-art sensors, and simulation models offer unprecedented opportunities for scientific discovery. Unsupervised classification is a widely applied data mining approach to derive insights from such data. However, classification of very large data sets is a complex computational problem that requires efficient numerical algorithms and implementations on high performance computing (HPC) platforms. Additionally, increasing power, space, cooling and efficiency requirements has led to the deployment of hybrid supercomputing platforms with complex architectures and memory hierarchies like the Titan system at Oak Ridge National Laboratory. The advent of such accelerated computing architectures offers new challenges and opportunities for big data analytics in general and specifically, large scale cluster analysis in our case. Although there is an existing body of work on parallel cluster analysis, those approaches do not fully meet the needs imposed by the nature and size of our large data sets. Moreover, they had scaling limitations and were mostly limited to traditional distributed memory computing platforms. We present a parallel Multivariate Spatio-Temporal Clustering (MSTC) technique based on k-means cluster analysis that can target hybrid supercomputers like Titan. We developed a hybrid MPI, CUDA and OpenACC implementation that can utilize both CPU and GPU resources on computational nodes. We describe performance results on Titan that demonstrate the scalability and efficacy of our approach in processing large ecological data sets.

Sreepathi, Sarat↗

COOLR: A New System for Dynamic Thermal-Aware Computing

Extreme-scale systems need to walk a fine line between the amount of cooling they receive and the thermal-induced performance and reliability degradation they can sustain. System managers are extremely motivated to battle cooling-energy cost: the largest line item in their total operating cost. On the other hand, pushing the nodes to peak performance in tightened cooling regimes places the burden on the dynamic thermal management (DTM) to protect the hardware. DTM schemes throttle performance to relieve heat accumulation within nodes when cooling cannot mitigate the problem. These interventions prevent fatal failures but introduce inevitable performance degradations and variations. Such variations can have drastic consequences on the performance of extreme-scale systems. Furthermore, distribution of heat across different system nodes depends not only on the amount of workload. Even if a strictly equal share of computational load is assigned to all nodes, there are physical attributes and topological features of each system that inherently cause uneven accumulation of heat. These can cause one subcomponent to trigger DTM prematurely and penalize the overall system. Our goal in this project is to create a holistic thermal-aware view of the system, capturing both inherent physical attributes and dynamic system state. We developed COOLR, a dynamic system with the ability to evaluate the interplay between management of computation, data, power dissipation, and thermal state. Thereby, COOLR will achieve higher overall performance at the same energy and cooling cost. First, we performed a systematic power and thermal modeling and of high performance computing architectures. Analytical and empirical techniques were blended to generate a light-weight thermal model of target systems. Second, we developed a thermal-aware OS and runtime system. Policies for managing resources and schedules for processes has been designed to co-optimize the thermal state and performance of the system. The main outcome of our proposed thermal-aware dynamic computing system are scheduling and allocation of processes and memory accesses leading to an appropriately “skewed” distribution of activity across the system. The ultimate result of this new arrangement resulted in reduced occurrences of hotspots and reduced episodes of DTM intervention, leading to improvements in performance. The overall thermal characterization and modeling methodology (thermal instrumentation techniques, model building, and systematic model reduction) resulting from this project can be applied to systems beyond our immediate scope and will be applicable to future scaling. The thermal-aware dynamic computing paradigm will impact the efficiency of extreme-scale systems. The gained “thermal slack” can be given back to further tighten the cooling budget, benefiting the management cost of next generation extreme-scale systems.

97 MATHEMATICS AND COMPUTING↗

Long Term Per-Component Power and Thermal Measurements of the OLCF Summit System

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data

97 MATHEMATICS AND COMPUTING↗

HPC Digital Twins for Evaluating Scheduling Policies, Incentive Structures and their Impact on Power and Cooling

Schedulers are critical for optimal resource utilization in high-performance computing. Traditional methods to evaluate sched- ulers are limited to post-deployment analysis, or simulators, which do not model associated infrastructure. In this work, we present the first-of-its-kind integration of scheduling and digital twins in HPC. This enables what-if studies to understand the impact of parameter configurations and scheduling decisions on the physical assets, even before deployment, or regarching changes not easily realizable in production. We (1) provide the first digital twin framework extended with scheduling capabilities, (2) integrate various top-tier HPC systems given their publicly available datasets, (3) implement extensions to integrate external scheduling simulators. Finally, we show how to (4) implement and evaluate incentive structures, as- well-as (5) evaluate machine learning based scheduling, in such novel digital-twin based meta-framework to prototype scheduling. Our work enables what-if scenarios of HPC systems to evaluate sustainability, and the impact on the simulated system.

Maiterth, Matthias [ORNL] (ORCID:000000018698460X)↗

A simple modern correctness condition for a space-based high-performance multiprocessor

A number of U.S. national programs, including space-based detection of ballistic missile launches, envisage putting significant computing power into space. Given sufficient progress in low-power VLSI, multichip-module packaging and liquid-cooling technologies, we will see design of high-performance multiprocessors for individual satellites. In very high speed implementations, performance depends critically on tolerating large latencies in interprocessor communication; without latency tolerance, performance is limited by the vastly differing time scales in processor and data-memory modules, including interconnect times. The modern approach to tolerating remote-communication cost in scalable, shared-memory multiprocessors is to use a multithreaded architecture, and alter the semantics of shared memory slightly, at the price of forcing the programmer either to reason about program correctness in a relaxed consistency model or to agree to program in a constrained style. The literature on multiprocessor correctness conditions has become increasingly complex, and sometimes confusing, which may hinder its practical application. We propose a simple modern correctness condition for a high-performance, shared-memory multiprocessor; the correctness condition is based on a simple interface between the multiprocessor architecture and a high-performance, shared-memory multiprocessor; the correctness condition is based on a simple interface between the multiprocessor architecture and the parallel programming system.

Probst, David K.↗

Exascale Computing Facility Modification (ECFM) Project Requirements Document

The objective of the project is to modify and upgrade the civil, structural, architectural, mechanical, and electrical systems of B453 and an adjacent approximately 3.5 acres of previously developed site. These modifications and upgrades would allow for continued use of B453 to support the increasing demands of the next generation high-performance computers. These modifications and upgrades would also provide enhanced power and cooling for the current and future ATS computers.

42 ENGINEERING↗

OLCF Summit Supercomputer GPU Snapshots During Double-Bit Errors and Normal Operations

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide double-bit errors using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). The dataset relies on Nvidia XID records internally collected by GPU firmware at the time of failure occurrence, on the reboot-time logs of each Summit node, on node-level job scheduler records collected after each job termination, and on a 1Hz data rate from the baseboard management controllers (BMCs) of each Summit compute node using the OpenBMC event subscription protocol. Technical details can be found in the paper Oles et. al “Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study” ICS’24 (https://doi.org/10.1145/3650200.3656615).

97 MATHEMATICS AND COMPUTING↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Water Quality for High Performance Computing

To support future generations of high performance computers, the Advanced Simulation and Computing Program has a mission need for 80MW of peak power and cooling. Currently the water for the cooling towers at the Strategic Computing Complex (SCC) are cooled by the LANL waste water treated Sanitary Effluent Recovery Facility (SERF) or potable water from the county. The SCC cooling towers currently operate by cycling water between 2-3 cycles of concentration (COC), which is less than the ideal 6 cycles for maximizing water usage. SERF is the ideal water supplier, however when it’s not available potable water is used. The amount of water that the SCC needs nominally is around 45 Million-Gallons/Year (MGY). The future super computer infrastructure (FSI) will need around 125 MGY nominally. SERF is approaching its production limit for reclaimed water. In order to avoid using 100% potable water for the FSI, the option of using non-potable reuse water from Los Alamos County (LAC) was analyzed. This project scope is to focus on the water quality needed for the new super computer cooling towers. Once water quality needs are established, the ideal treatment process needs to be determined. Due to high silica content in water at Los Alamos, emphasis has been placed on treatment processes to remove silica. SERF’s current and future ability to treat water was assessed, as well as the cost of running a SERF like facility or alternative.

97 MATHEMATICS AND COMPUTING↗

SystemBurn: Principles of Design and Operation Release 2.1

As high performance computing technology progresses toward the progressively more extreme scales required to address critical computational problems of both national and global interest, power and cooling for these extreme scale systems is becoming a growing concern. A standardized methodology for testing system requirements under maximal system load and validating system environmental capability to meet those requirements is critical to maintaining system stability and minimizing power and cooling risks for high end data centers. Moreover, accurate testing permits the high end data center to avoid issues of under- or over-provisioning power and cooling capacity saving resources and mitigating hazards. Previous approaches to such testing have employed an ad hoc collection of tools, which have been anecdotally perceived to produce a heavy system load. In this report, we present SystemBurn, a software tool engineered to allow a system user to methodically create a maximal system load on large scale systems for the purposes of testing and validation.

99 GENERAL AND MISCELLANEOUS↗

DCDM1: Lessons Learned from the World's Most Energy Efficient Data Center

This presentation discusses the holistic approach to design the world's most energy-efficient data center, which is located at the U.S. Department of Energy National Renewable Energy Laboratory (NREL). This high-performance computing (HPC) data center has achieved a trailing twelve-month average power usage effectiveness (PUE) of 1.04 and features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. We provide details of the demonstrated PUE and energy reuse effectiveness (ERE) and lessons learned during four years of production operation. Recent efforts to dramatically reduce the water footprint will also be discussed. Johnson Controls partnered with NREL and Sandia National Laboratories to deploy a thermosyphon cooler (TSC) as a test bed at NREL's HPC data center that resulted in a 50% reduction in water usage during the first year of operation. The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device with an open cooling tower.

97 MATHEMATICS AND COMPUTING↗