Search NASA⌕ Search

SEARCH · Search NASA

Results for “High latent heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗

Concept evaluation of four thermal utility systems for low orbit spacecraft

Attention is given to the design features and comparative performance of four two-phase heat transport systems under consideration by NASA as long term space mission devices for the collection, transportation and rejection of waste heat from spacecraft components over the zero-100 C temperature range. The system types are: a mechanically pumped two-phase loop, a capillary pumped loop, an osmotic pumped loop, and a loop employing a biomorph pump. The principal advantage of a capillary pumped loop is that it is a passive system with few moving parts that inherently possesses high reliability. The working fluid recommended for use in such a thermal utility is NH3, which has the requisite combination of high latent heat of vaporization and high surface tension.

Peterson, G. P.↗

Superheat in magma oceans

The existence of 'totally molten' planets implies the existence of a superheat (excess of heat) in the magma reservoirs since the heat buffer (i.e., presence of crystals having high latent heat of fusion) does not exist in a large, completely molten reservoir. Any addition of impacting material results in increase of the temperature of the melt and under favorable circumstances heat is stored. The behavior of superheat melts is little understood; therefore, we experimentally examined properties and behavior of excess heat melts at atmospheric pressures and inert gas atmosphere. Highly siliceous melts (70 percent SiO2) were chosen for the experiments because of the possibility of quenching such melts into glasses, the slow rate of reaction in highly siliceous composition, and the fact that such melts are present in terrestrial impact craters and impact-generated glasses. Results from the investigation are presented.

Jakes, Petr↗

Observed effects of landscape variability on convective clouds

A case is presented in which clouds are observed to form first over a mesoscale-size area (100 x 300 km) of harvested wheat in Oklahoma, where the ground temperature is warmer than adjoining areas dominated by growing vegetation. In addition, clouds are suppressed over relatively long bands downwind of small man-made lakes and areas characterized by heavy tree cover. The observed variability of cloud relative to landscape type is compared with that simulated with a one-dimensional boundary-layer model. Clouds form earliest over regions characterized by high, sensible heat flux, and are suppressed over regions characterized by high, latent heat flux during relatively dry atmospheric conditions. This observation has significance in gaining understanding of the feedback mechanisms of land modification on climate, as well as understanding relatively short-range weather forecasting.

Rabin, Robert M.↗

Development of a two-zone zero-dimensional mixing model for actively fueled prechamber engines

In this numerical work, a zero-dimensional, two-zone mixing model was developed and validated to capture the mixture preparation process of an actively fueled prechamber engine. The model was developed for ethanol-gasoline fuel blends but is applicable to various fuels of interest relevant to prechamber applications. The model was exercised to demonstrate the effects of boundary conditions, fuel composition, and residual content on the mixture stoichiometry predictions. The 0D model showed reasonable agreement in prechamber equivalence ratio predictions with higher fidelity computational fluid dynamics modeling, but the accuracy of model was constrained to the governing assumptions of the injection process. The modeling assumptions surrounding the non-dimensional injection of mass into the prechamber were scrutinized to identify key areas of model improvement. The results indicate heat transfer effects play a crucial role in the evaporation of the fuel within the confined auxiliary chamber, especially when considering fuels with high latent heat of vaporization. Additionally, the presence of fuel films that collect on the prechamber surfaces complicated the modeled evaporative cooling loses as the modeling suggests the films evaporate primarily by means of conduction from the boundary. Furthermore, the developed model serves as a simplified framework to generate calibration maps of prechamber fueling or run real time as an open loop control strategy such that desired prechamber mixture proportions are effectively targeted.

Zero-dimensional↗

Evaporation-Cooled Protective Suits for Firefighters

Suits cooled by evaporation of water have been proposed as improved means of temporary protection against high temperatures near fires. When air temperature exceeds 600 F (316 C) or in the presence of radiative heating from nearby sources at temperatures of 1,200 F (649 C) or more, outer suits now used by firefighters afford protection for only a few seconds. The proposed suits would exploit the high latent heat of vaporization of water to satisfy a need to protect against higher air temperatures and against radiant heating for significantly longer times. These suits would be fabricated and operated in conjunction with breathing and cooling systems like those with which firefighting suits are now equipped

Weinstein, Leonard Murray↗

Water Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft’s radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a “topper” to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. Studies conducted in this paper investigate utilizing water’s high latent heat of formation as a PCM, as opposed to traditional waxes, and corresponding complications surrounding freezing water in an enclosed volume. Work highlighted in this study is primarily visual and includes understanding ice formation, freeze front propagation, and the solidification process of water/ice. Various test coupons were constructed of copper to emulate the interstitial pin configuration (to aid in conduction) of the proposed water PCM HX design. Construction of a prototypic HX was also completed in which a flexible bladder material and interstitial pin configurations were tested. Additionally, a microgravity flight was conducted where three copper test articles were frozen continuously during microgravity and 2-g periods and individual water droplets were frozen during microgravity.

Hansen, Scott W.↗

Hot filament technique for measuring the thermal conductivity of molten lithium fluoride

Molten salts, such as lithium fluoride, are attractive candidates for thermal energy storage in solar dynamic space power systems because of their high latent heat of fusion. However, these same salts have poor thermal conductivities which inhibit the transfer of heat into the solid phase and out of the liquid phase. One concept for improving the thermal conductivity of the thermal energy storage system is to add a conductive filler material to the molten salt. High thermal conductivity pitch-based graphite fibers are being considered for this application. Although there is some information available on the thermal conductivity of lithium fluoride solid, there is very little information on lithium fluoride liquid, and no information on molten salt graphite fiber composites. This paper describes a hot filament technique for determining the thermal conductivity of molten salts. The hot filament technique was used to find the thermal conductivity of molten lithium fluoride at 930 C, and the thermal conductivity values ranged from 1.2 to 1.6 W/mK. These values are comparable to the slightly larger value of 5.0 W/mK for lithium fluoride solid. In addition, two molten salt graphite fiber composites were characterized with the hot filament technique and these results are also presented.

Jaworske, Donald A.↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Effect of NO on DME-Methanol HCCI Combustion Using a Reduced Chemical Kinetics Mechanism

Methanol is an attractive fuel for the maritime sector due to its wide availability. Its direct use as a fuel, however, is accompanied by challenges such as high latent heat of vaporization and low cetane number. A potential solution to overcome the ignition properties of methanol could be through on-board generation of dimethyl ether (DME) via catalytic dehydration of methanol. The resulting mixture from dehydration can be mixed in with the intake air to generate a homogenous charge compression ignition (HCCI) preburn for subsequent direct injection (DI) mixing controlled compression ignition (MCCI) of neat methanol. Within that context, complementary experimental work found that the influence of combustion residuals on the heat release rate (HRR) was significant, specifically for residual NO. This finding motivated the present computational and kinetic evaluation of the effects of NO on the low (LTHR) and high (HTHR) temperature heat release rates. The strong influence of small quantities of NO on the combustion process of a DME/methanol/H2O mixture (low catalyst or reactor efficiency) necessitated a kinetics-based investigation into this phenomenon. A mechanism sourced from the existing literature with NO had 172 species and 1375 reactions, making it computationally expensive for use. Hence, a mechanism reduction effort was implemented, and a rate constant (k) tuning effort based on sensitivity analysis was needed to validate experimental results using a zero-dimensional engine model in Cantera. The reduced mechanism was able to successfully capture the negligible influence of NO addition on DME HCCI combustion, whereas an advancement in LTHR and HTHR for a DME/methanol/H2O mixture was kinetically confirmed. Reaction pathway analysis showed that addition of NO chemically counteracted the OH sink created by alcohols like methanol, increasing the effectiveness of DME ignition.

Tyrewala, Daanish [ORNL] (ORCID:0000000208599324)↗

Effect of NO on DME-Methanol HCCI Experimental Observations

Methanol is an attractive fuel for the maritime sector due to its wide availability. Its direct use as a fuel, however, is accompanied by challenges such as high latent heat of vaporization and low cetane number. A potential solution to overcome the ignition properties of methanol could be through on-board generation of dimethyl ether (DME) via catalytic dehydration of methanol. The resulting mixture from dehydration can be mixed in with the intake air to generate a homogenous charge compression ignition (HCCI) preburn for subsequent direct injection (DI) and successful ignition methanol at diesel–like timescales. However, if the preburn species are treated separately from the complete methanol MCCI approach the preburn heat release rate (HRR) phasing and behavior do not replicate the preburn behavior of the complete approach. Thus, the presence of the main methanol mixing controlled compression ignition (MCCI) combustion event influences the DME/methanol preburn kinetics. Specifically, it was found that trapped residual temperature alone was insufficient alone to be responsible for the observed differences, and that trace species concentrations of NO in the trapped residual gas also influenced DME/methanol kinetics increasing low temperature heat release (LTHR) magnitude and advancing high temperature heat release (HTHR) phasing. NO is not present in HCCI combustion of neat DME or DME/methanol blends nor is elevated gas temperature in the trapped residuals; both of which result in failure to accurately predict the HCCI combustion of DME/methanol blends when coupled with subsequent DI methanol MCCI. This work experimentally explores the effect of trapped residual temperature and NO on DME and DME/methanol HCCI combustion.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗

A single-zone zero-dimensional study of HCCI combustion of methanol dehydration products to enable ignition of direct-injected methanol

Methanol is an alternative fuel gaining traction in the maritime sector. Its direct adoption, however, is accompanied by a unique set of technical challenges, such as low cetane number and high latent heat of vaporization. An approach to overcome these challenges is being developed at the US Department of Energy’s Oak Ridge National Laboratory, where onboard generation of dimethyl ether (DME) via catalytic dehydration of methanol can be used to assist in the mixing controlled combustion of direct-injected (DI) methanol. The generated mixture from this dehydration process can be premixed with intake air to condition the cylinder via. homogeneous charge compression ignition (HCCI) for subsequent DI methanol. In this preliminary work, various catalyst or reactor conversion efficiencies were simulated (using bottles) at constant DME and water flow at low load on a single-cylinder marine-variant of a CAT® C18 18 L engine with a 145 mm bore. To substantiate the experimental findings, a zero-dimensional engine model was developed in Cantera using a DME mechanism with 79 species and 658 reactions. Results presented include experimental and simulation heat release rate comparisons, species evolution information, and constant volume ignition delay (ID) for DI methanol with and without background species from HCCI of the premixed products from different reactor efficiencies. The results suggest that thermal effects dominate the DI methanol ignition process, and this work provides a chemical kinetic foundation or guideline for developing future control schemes.

Tyrewala, Daanish [ORNL] (ORCID:0000000208599324)↗

Impact of Cooling Rate and Thermal Mass on Supercooling in a Salt-Hydrogel Complex for Thermal Energy Storage

Glauber’s salt is a promising phase change material for building thermal management because of its high latent heat, acceptable melting temperature of 32.3 °C for indoor air1,2. Despite these advantages, the practical application of Glauber’s salt in thermal energy storage systems is still challenging due to supercooling and phase segregation1–3. Here, we report the impact of temperature ramp rate and thermal mass on the supercooling of Glauber’s salt through the DSC and T-history experiment. The ramp rate effect was studied with a wide range of ramp rates in 1 to 10 °C/min in DSC and 1 to 4 °C/min in the T-history experiment. The thermal mass effect was investigated by comparing DSC and T-history experiment. The latent heat was also analyzed for different ramp rates and thermal mass conditions. The melting temperatures of Glauber’s salt from the two techniques were identical while freezing temperatures were different because of the thermal mass effect. During freezing in the T-history experiment, the latent heat was reduced by around 75% to the latent heat in melting due to supercooling and phase segregation. To overcome this bottleneck, we developed a novel hydrogel complex that reduces the supercooling and prevents phase segregation to maintain volumetric energy density for 100 cycles. Thermodynamic analysis accounting for composition shows that a higher salt composition can further enhance the volumetric energy storage density. For example, a 10% increase in the weight percentage of salt leads to about 50% enhancement in volumetric energy storage density. References: 1. D. R. Biswas, Solar Energy. 19, 99–100 (1977). 2. S. M. Hasnain, Energy Conversion and Management. 39, 1127–1138 (1998). 3. Byung Chul Shin, Sang Done Kim, P. Won-Hoon, Energy. 14, 921–930 (1989).

inorganic, thermodynamics↗

Applications of fibrous substrates containing insolubilized phase change polymers

Incorporation of polyethylene glycols into fibrous substrates produces several improved functional properties when they are insolubilized by crosslinking with a methylolamide resin or by polyacetal formation by their reaction with glyoxal. The range of molecular weights of polyols that may be insolubilized is broad as are the curing conditions (0.25-10 min at 80-200C). Most representative fiber types and blends (natural and synthetic) and all types of fabric constructions (woven, nonwoven and knit) have been modified by incorporation of the bound polyols. The most novel property is the thermal adaptability of the modified substrates to many climatic conditions. This adaptability is due to the high latent heat of the crosslinked polyols that function as phase change materials, the hydrophilic nature of the crosslinked polymer and its enhanced thermal conductivity. Other enhanced properties imparted to fabrics include flex and flat abrasion, antimicrobial activity, reduced static charge, resistance to oily soils, resiliency, wind resistance and reduced lint loss. Applications commercialized in the U.S. and Japan include sportswear and skiwear. Several examples of electric sets of properties useful for specific end uses are given. In addition, other uses are biomedical horticultural, aerospace, indoor insulation, automotive interiors and components and packaging material.

Vigo, Tyrone L.↗

Approach for High Methanol Substitution by Energy with Conventional and Bio Pilot Fuels

Green methanol is emerging as a promising route to decarbonize the commercial marine industry. However, methanol is not a drop-in fuel in the compression ignition engines that dominate the marine industry because it is difficult to ignite due to its low cetane number and high latent heat of vaporization. The most straight-forward way to use methanol in the compression ignition engines is to premix the methanol, such as with port fuel injection during the intake stroke, and igniting the methanol with a diesel pilot injection. Because diesel fuel is still used in this strategy, it does not fully displace the petroleum diesel fuel. To completely displace the petroleum-derived diesel fuel, this investigation presents experimental results comparing diesel and biodiesel pilot ignition in a dual-fuel strategy with methanol in a marine-variant of a Cat® C18 18 L engine with a 145 mm bore. Engine performance and emissions characteristics are presented that include effects of diesel vs. biodiesel across a series of fuel injection timing and other operating parameters, including intake manifold pressure and engine load. Results presented include in-cylinder pressure and combustion-related findings about heat release, methanol fuel energy substitution rates greater than 75% from 1 to 18 bar BMEP on a single cylinder engine at 1800 RPM. Criteria pollutants including particulate matter, NOx (NO and NO2), unburned fuel, and formaldehyde, as well as the overall BSFC and FSN of the combustion process relative to the baseline diesel operation.

Splitter, Derek [ORNL] (ORCID:0000000174044047)↗

Influence of Operating Conditions on Ethanol Passive Prechamber Cold-start Operation

Cold-start operation in spark ignition engines is characterized by many drawbacks such as poor fuel vaporization, substantial wall film formation, and weak ignition which can result in unstable combustion and high concentrations of carbon monoxide (CO), nitrogen oxides (NOx), and unburnt hydrocarbons (UHC) prior to catalyst light-off. These challenges are particularly important for ethanol as the fuel’s high latent heat of vaporization and low vapor pressure can hinder reliable ignition during cold-start. In this context, passive prechamber ignition systems offer a viable pathway to improve ignitability by producing hot turbulent jets that can promote combustion in the main chamber. In this study, the influence of operating conditions on jet formation and combustion characteristics in an ethanol-fueled passive prechamber spark ignition engine is investigated. Two intake pressures (40 kPa and 60 kPa) and two engine speeds (450 and 600 rpm) are studied to represent various stages of the cold-start ramp-up. Results indicate that lower intake pressures lead to delayed and asymmetric turbulent jet formation, and lower peak heat release rates. Lower engine speeds, on the other hand, produced higher peak heat release and faster combustion due to greater residence time in the engine. This greater residence time also increases the likelihood of autoignition in the main chamber, potentially promoting quicker heat release for lower engine speeds. These results provide insight into the role of operating conditions on cold-start ramp-up of passive prechamber engines.

Banagiri, Shrikar [ORNL] (ORCID:0000000239745099)↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗