High-Resolution X-ray Photoelectron Spectroscopy of an IrO2(110) Film on Ir(100)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.
Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.
We present the first high-resolution spectroscopy of the black hole high-mass X-ray binary Cygnus X-1 with XRISM, including orbital-phase-resolved analyses and tentative evidence of short-term variability in the Fe K band on second timescales. Using data from the Performance Verification phase in 2024 April, we analyzed spectral variability across orbital phases with the Resolve microcalorimeter and the Xtend CCD imager. The unprecedented resolution of Resolve reveals variability in highly ionized Fe absorption lines. The absorption features show orbital-phase-dependent variability in column density, ionization state, and blueshifted velocity, suggesting structural variations in the focused stellar wind along the line of sight. We also find indications of subtle broadening of the neutral Fe emission profile. In addition, intensity-sorted spectroscopy during dip phases suggests possible variability on timescales of a few seconds in the absorption features, consistent with cooler, denser, and lower-ionized gas clumps. Although the statistical significance is limited, these results hint that the stellar wind and the X-rays from the accretion disk around the black hole may interact on timescales as short as a few seconds. These XRISM results constrain wind-fed accretion in Cyg X-1 and highlight Resolve’s capability to probe plasma environments in high-mass X-ray binaries.
In this work, we present an analysis of the first observation of the iconic High Mass X-ray Binary 4U 1700-37 with the Chandra High Energy Transmission Gratings during an X-ray eclipse. The goal of the observation was to study the structure/physical conditions in the clumpy stellar wind through high resolution spectroscopy. We find that: a) emission line brightness from K shell transitions, corresponding to near neutral species, directly correlates with continuum illumination. However, these lines do not greatly diminish during eclipse. This is readily explained if fluorescence Kα emission comes from the bulk of the wind. b) The highly ionised Fe xxv and Fe xxvi Lyα diminish during eclipse. Thus, they must be produced in the vicinity of the compact object where log ξ > 3. c) to describe the emission line spectrum, the sum of two self consistent photo ionisation models with low ionisation (log ξ ~ -1) and high ionisation (log ξ ~2.4) is required. From their emission measures, the clump-to-interclump density ratio can be estimated to be nc/ni ~ 300. To fit the complex He-like Si xiii profile, the plasma requires a broadening with vbulk ~ 840 km s-1. Reproducing the observed r ≈ f line fluxes requires the addition of a third collisionally ionised plasma. d) Emission lines widths appear unresolved at the hetg gratings resolution with exception of Silicon. There is no clear radial segregation between (quasi)neutral and ionised species, consistent with cold wind clumps interspersed in a hot rarefied interclump medium.
A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.
In this work, we present a ~130 ks observation of the prototypical wind-accreting, high-mass X-ray binary Vela X-1 collected with XMM-Newton at orbital phases between 0.12 and 0.28. A strong flare took place during the observation that allows us to investigate the reaction of the clumpy stellar wind to the increased X-ray irradiation. To examine the wind’s reaction to the flare, we performed both time-averaged and time-resolved analyses of the RGS spectrum and examined potential spectral changes. We focused on the high-resolution XMM-Newton RGS spectra and divided the observation into pre-flare, flare, and post-flare phases. We modeled the time-averaged and time-resolved spectra with phenomenological components and with the self-consistent photoionization models calculated via CLOUDY and XSTAR in the pre-flare phase, where strong emission lines due to resonant transitions of highly ionized ions are seen. In the spectra, we find emission lines corresponding to K-shell transitions in highly charged ions of oxygen, neon, magnesium, and silicon as well as radiative recombination continua (RRC) of oxygen. Additionally, we observe potential absorption lines of magnesium at a lower ionization stage and features identified as iron L lines. The, CLOUDY and XSTAR photoionization models provide contradictory results, either pointing towards uncertainties in theory or possibly a more complex multi-phase plasma, or both. We are able to demonstrate the existence of a plethora of variable narrow features, including the firm detection of oxygen lines and RRC that RGS enables to observe in this source for the first time. We show that Vela X-1 is an ideal source for future high-resolution missions, such as XRISM and Athena.
Abstract Cyclotron radiation emission spectroscopy (CRES) is an approach to measuring the energy of an electron trapped in an externally applied magnetic field. The bare electron can come from different interactions, including photoelectric absorption, Compton scatters, beta decay, and pair production. CRES relies on measuring the frequency of the electron’s cyclotron motion, and because the measurement times extend over 10 6 –10 7 cycles, the energy resolution is on the order of a single electronvolt. To date, CRES has only been performed on internal beta-emitting radioisotopes, but the technology can be applied to x-ray spectrometery through appropriate selection of a target gas and sufficient intensity of the distinct x-ray source. The applications of this technology range from high-precision measurements of atomic energy levels to calibrations of basic science experiments, to trace element identification. In this work we explore the use of CRES for x-ray spectroscopy within the rubric of measuring the energy levels of argon. Though the energy levels of argon are well established, we adopt this motivation as an example question around which a detector may be designed. The issues we explore include target material, density, electron trapping depth, noise levels, and overall efficiency. We also discuss spectral deconvolution and how the multiple peaks obtained from a single target/source pair can be used to enhance the robustness of the measurement.
is an open-source program to select asymmetric geometries of spherically bent crystal analyzers for X-ray spectroscopy, thus achieving improved energy resolution and operational flexibility.
Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.
Dynamics and parameters of gas-puff Z-pinch plasmas at stagnation were studied using x-ray spectroscopic diagnostics. In experiments on a 1 MA pulsed power generator, multilayer coaxial loads were made using a triple-nozzle gas-puff valve. High-luminosity spectrographs with spherically bent crystals made it possible to record spectra with high spatial resolution along the pinch axis and to record two-dimensional plasma images in separate spectral lines. Using various combinations of gases in the nozzles and adding small amounts of a gas tracer, the final structure and composition of the compressed plasma were determined. Furthermore, plasma parameters were estimated by modeling the spectra using the PrismSPECT program, but with the limitation that the spectra were time-integrated, so that spectra from different gases and at different positions may have been emitted at different times.
Advances in electrocatalysis research rely heavily on building a thorough mechanistic understanding of catalyst active sites under realistic operating conditions. Only recently have techniques emerged that enable sensitive spectroscopic data collection to distinguish catalytically relevant surface sites from the underlying bulk material under applied potential in the presence of an electrolyte layer. Here, we demonstrate that operando high-energy-resolution fluorescence detected X-ray absorption spectroscopy (HERFD-XAS) is a powerful spectroscopic method which offers critical surface chemistry insights in CO 2 electroreduction with sub-electronvolt energy resolution using hard X-rays. Combined with the high surface area-to-volume ratio of 5 nm copper nanoparticles, operando HERFD-XAS allows us to observe with clear evidence the breaking of chemical bonds between the ligands and the Cu surface as part of the ligand desorption process occurring under electrochemical potentials relevant for the CO 2 reduction reaction (CO 2 RR). In addition, the dynamic evolution of oxidation state and coordination number throughout the operation of the nanocatalyst was continuously tracked. With these results in hand, undercoordinated metallic copper nanograins are proposed to be the real active sites in the CO 2 RR. In conclusion, this work emphasizes the importance of HERFD-XAS compared to routine XAS in catalyst characterization and mechanism exploration, especially in the complicated electrochemical CO 2 RR.
To extract chemical information reliably, we propose a new data processing method based both on the creation of information vectors and on a vector base change. The originality of this method is the combination of the different core XPS peaks, Auger and/or valence bands in a single vector. We show that the measurement of a sample upon its progressive chemical change, such as accumulation of the adventitious carbon, allows us to create a new vector basis using linear algebra and Principal Component Analysis. In this work, we demonstrate the application of this method using adventitious carbon films on Au foil utilizing Au 4f, C 1s and O 1s spectral envelopes. This method expands the possibilities of XPS measured chemical environment analysis and is an operator-unbiased solution for materials for which the reference XPS spectra are not available. In this demonstration, the emphasis is placed on identifying changes in a C 1s peak assumed to be adventitious carbon and highlight uncertainties associated with calibrating the binding energy scale using a simple peak model to identify a component C 1s assumed to be saturated hydrocarbon in origin.
Electrocatalysis unfolds at the interface—where solids, liquids, and gases meet to exchange charge, transform molecules, and set the foundation for technologies like CO 2 conversion, and water splitting. These interfacial regions are inherently dynamic, chemically diverse, and structurally heterogeneous. How atoms rearrange, oxidize, coordinate ligands, or adsorb reaction intermediates under electro-chemical potential defines a catalyst’s performance. Furthermore, capturing these changes with element specificity and electronic sensitivity under operando conditions remains one of the most critical challenges in the field.
X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.
An extensive experimental and theoretical study of the Kα and Kβ high-resolution X-ray emission spectroscopy (XES) of sulfur-bearing systems is presented here. This study encompasses a wide range of organic and inorganic compounds, including numerous experimental spectra from both prior published work and new measurements. Employing a linear-response time-dependent density functional theory (LR-TDDFT) approach, strong quantitative agreement is found in the calculation of energy shifts of the core-to-core Kα as well as the full range of spectral features in the valence-to-core Kβ spectrum. The ability to accurately calculate the sulfur Kα energy shift supports the use of sulfur Kα XES as a bulk-sensitive tool for assessing sulfur speciation. The fine structure of the sulfur Kβ spectrum, in conjunction with the theoretical results, is shown to be sensitive to the local electronic structure including effects of symmetry, ligand type and number, and, in the case of organosulfur compounds, to the nature of the bonded organic moiety. This agreement between theory and experiment, augmented by the potential for high-access XES measurements with the latest generation of laboratory-based spectrometers, demonstrates the possibility of broad analytical use of XES for sulfur and nearby third-row elements. The effective solution of the forward problem, i.e., successful prediction of detailed spectra from known molecular structure, also suggests future use of supervised machine learning approaches to experimental inference, as has seen recent interest for interpretation of X-ray absorption near-edge structure (XANES).
The epitaxial development and characterization of metamorphic “GaSb-on-silicon” buffers as substrates for antimonide devices is presented. The approach involves the growth of a spontaneously and fully relaxed GaSb metamorphic buffer in a primary epitaxial reactor, and use of the resulting “GaSb-on-silicon” wafer to grow subsequent layers in a secondary epitaxial reactor. The buffer growth involves four steps—silicon substrate preparation for oxide removal, nucleation of AlSb on silicon, growth of the GaSb buffer, and finally capping of the buffer to prevent oxidation. This approach on miscut silicon substrates leads to a buffer with negligible antiphase domain density. The growth of this buffer is based on inducing interfacial misfit dislocations between an AlSb nucleation layer and the underlying silicon substrate, which results in a fully relaxed GaSb buffer. A 1 μm thick GaSb layer buffer grown on silicon has ~9.2 × 10 7 dislocations/cm 2 . The complete lack of strain in the epitaxial structure allows subsequent growths to be accurately lattice matched, thus making the approach ideal for use as a substrate. Here we characterize the GaSb-on-silicon wafer using high-resolution x-ray diffraction and transmission electron microscopy. The concept’s feasibility is demonstrated by growing interband cascade light emitting devices on the GaSb-on-silicon wafer. The performance of the resulting LEDs on silicon approaches that of counterparts grown lattice matched on GaSb.