Search NASA⌕ Search

SEARCH · Search NASA

Results for “High vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deployable Element Ultra-High Vacuum Pump

Advancing Ultra High Vacuum (UHV) Pumping Technology: The deployable UHV pump team has designed a theoretical model to boost efficiency in high vacuum environments. Traditional systems face challenges with random molecular motion. The innovative windmill design, using titanium sublimation technology, reduces randomness by deploying a gettering surface that actively captures particles. This marks a notable advancement in UHV pumping technology.

43 PARTICLE ACCELERATORS↗

Quantum control and Berry phase of electron spins in rotating levitated diamonds in high vacuum

Levitated diamond particles in high vacuum with internal spin qubits have been proposed for exploring macroscopic quantum mechanics, quantum gravity, and precision measurements. The coupling between spins and particle rotation can be utilized to study quantum geometric phase, create gyroscopes and rotational matter-wave interferometers. However, previous efforts in levitated diamonds struggled with vacuum level or spin state readouts. To address these gaps, we fabricate an integrated surface ion trap with multiple stabilization electrodes. This facilitates on-chip levitation and, for the first time, optically detected magnetic resonance measurements of a nanodiamond levitated in high vacuum. The internal temperature of our levitated nanodiamond remains moderate at pressures below 10 -5 Torr. We have driven a nanodiamond to rotate up to 20 MHz (1.2 × 10 9 rpm), surpassing typical nitrogen-vacancy (NV) center electron spin dephasing rates. Using these NV spins, we observe the effect of the Berry phase arising from particle rotation. In addition, we demonstrate quantum control of spins in a rotating nanodiamond. These results mark an important development in interfacing mechanical rotation with spin qubits, expanding our capacity to study quantum phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗

Ultra-High Vacuum Outgassing Characterization of Thermally Processed Low-Carbon Steel for Advanced Particle Accelerator and Gravitational Wave Detector Applications

This dissertation investigated AISI 1020 low-carbon steel as an alternative vacuum chamber material to conventional stainless steel for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications. After a 400 °C/48 h bake, AISI 1020 tube chambers achieved a hydrogen outgassing rate of 2.4 × 10¿¹6 Torr·L·s¿¹·cm¿², approximately 2,300 times lower than the prebaked 316L stainless-steel comparator, among the lowest hydrogen outgassing rates ever reported for an uncoated metallic vacuum chamber. Bare and magnetite-coated AISI 1020 chambers were then compared using throughput and rate-of-rise methods. The magnetite coating yielded 5× lower water outgassing at room temperature, but this advantage disappeared after 80 °C baking. After full thermal conditioning (400 °C/48 h prebake followed by 150 °C/96 h and 200 °C/110 h), bare steel achieved 25× lower hydrogen outgassing than the magnetite-coated chamber (9.6 × 10¿¹6 Torr·L·s¿¹·cm¿²) and >99% H2 purity with carbon species below RGA detection. Monte Carlo molecular flow simulations of a CEBAF photogun beamline (96 scenarios) showed that replacing 304L stainless steel with AISI 1020 reduces equilibrium H2 pressure by a factor of 833; a single 304L electrode contributes 98.8% of the gas load despite occupying only 9.1% of the internal surface area. A 500-m Einstein Telescope beampipe screening showed that corrugated bellows contribute 18% of the gas load from only 0.7% of the surface area. A five-model adsorption isotherm framework applied to 22 pumpdown datasets (164 fits with AR(1)-GLS correction) established that the experimental protocol, not the material, controls isotherm identifiability: Dubinin–Radushkevich wins isothermal pipe pumpdowns; Langmuir wins thermally dominated chamber bakes. Cross-dataset joint fitting of the AISI 1020 pipe pumpdowns yielded an H2 diffusion activation energy Ed = 7.24 ± 1.28 kcal·mol¿¹, consistent with trap dominated diffusion in commercial low-carbon steels. Two companion innovations were developed: a Variable Conductance Device (VCD, patent pending IDF-00723) for XHV outgassing measurement, and VacuumDesignerPro (VDP), a MATLAB-based design tool validated against LIGO benchmarks.

Al-Allaq, Aiman H [Old Dominion University]↗

Passively pumped, polycrystalline ceramic high and ultra-high vacuum chambers

A sealed, passively pumped, polycrystalline ceramic vacuum chamber and method for fabricating the chamber are disclosed. The body of the vacuum chamber is made from a polycrystalline ceramic, for example, alumina. The vacuum chamber includes one or more windows made from a transparent ceramic, for example, sapphire, to accommodate optical access, while remaining amorphous-glass free to minimize or eliminate helium permeation. The vacuum chamber components are joined via laser welding or furnace brazing and the completed chamber is bakeable at temperatures up to 400° C. The vacuum chamber can operate at high or ultra-high vacuum pressures for an extended period through the use of one or more getter-based pumps. The vacuum chamber may include one or more atomic sources depending upon the application.

Walker, Charles A.↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

Extreme high vacuum for polarized electron sources

Nuclear physics experiments often require highly polarized electron beams to do precise measurements of the structure and size of nucleons and the nucleus, as well as for searches for physics beyond the standard model. Jefferson Lab?s electron source, with polarization near 90%, has been providing polarized electron beams for CEBAF for over two decades. Development is underway for polarized electron sources at MESA at Mainz and the Electron Ion Collider at Brookhaven National Lab, and there is potential for polarized electron beam in the future at facilities including the International Linear Collider, an electron upgrade at CERN, and the SuperKEKB collider in Japan. At Jefferson Lab there are even plans to make use of polarized electrons to make a polarized positron source for experimental nuclear physics. High polarization electron beams are generated using photoemission from strained superlattice GaAs based photocathodes, and photocathode lifetime is limited by the ionization of residual gas in the system, which is then accelerated into the photocathode. Extreme high vacuum (near 1x10-10 Pa) is required to operate the Jefferson Lab polarized electron source with an acceptable lifetime, and the upcoming projects will need various combinations of higher current, higher bunch charge and longer photocathode lifetimes. To meet the vacuum requirements for polarized electron sources, every component for a polarized electron source must be optimized, including chamber materials, pumps, bakeout procedure and the high voltage electrode geometry and processing. Each change in these components must be evaluated offline before being used in the accelerator, and effects on pressure are difficult to evaluate even using XHV-optimized hot filament ionization gauges. In fact, we do not get a final evaluation of system modifications until an electron source is built, installed and lifetime measurements are made over the course of months or years of operation. I will be discussing the evolution of vacuum in the Jefferson Lab polarized source system toward XHV pressures and discuss the characterization and limitations measured for commercially available XHV vacuum gauges. Finally, I?ll present the effect of system pressure on photocathode lifetime and highlight how XHV pressure standards can benefit the ongoing efforts to improve vacuum for the next generation of polarized electron sources.

Stutzman, Marcy↗

A modular ultra-high vacuum millikelvin scanning tunneling microscope

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our design is to achieve a high level of modularity by partitioning the STM system into a set of easily separable, interchangeable components. This naturally segregates the UHV needs of STM instrumentation from the typically non-UHV construction of a dilution refrigerator, facilitating the usage of non-UHV materials while maintaining a fully bakeable UHV chamber that houses the STM. Here, the modular design also permits speedy removal of the microscope head from the rest of the system, allowing for repairs, modifications, and even replacement of the entire microscope head to be made at any time without warming the cryostat or compromising the vacuum. Without using cryogenic filters, we measured an electron temperature of 184 mK on a superconducting Al(100) single crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Degradation of Ta 2 O 5 / SiO 2 dielectric cavity mirrors in ultra-high vacuum

In order for optical cavities to enable strong light-matter interactions for quantum metrology, networking, and scalability in quantum computing systems, their mirrors must have minimal losses. However, high-finesse dielectric cavity mirrors can degrade in ultra-high vacuum (UHV), increasing the challenges of upgrading to cavity-coupled quantum systems. We observe the optical degradation of high-finesse dielectric optical cavity mirrors after high-temperature UHV bake in the form of a substantial increase in surface roughness. We provide an explanation of the degradation through atomic force microscopy (AFM), X-ray fluorescence (XRF), selective wet etching, and optical measurements. We find the degradation is explained by oxygen reduction in Ta 2 O 5 followed by growth of tantalum sub-oxide defects with height to width aspect ratios near ten. We discuss the dependence of mirror loss on surface roughness and finally give recommendations to avoid degradation to allow for quick adoption of cavity-coupled systems.

Optics↗

Corrosion of 304 stainless steel in static liquid lithium under high vacuum

To study the compatibility especially the corrosion characteristic of structural material stainless steel (SS) with liquid lithium (Li) is an important factor for the simultaneous application of liquid Li and SS as a blanket material or potential plasma facing material (PFM) in future fusion devices. Here, the corrosion behaviors of 304SS exposed to liquid Li at 700 K for 1320 hr under high vacuum were investigated. After exposure to liquid Li, 304SS produces non-uniform corrosion which includes corrosion products and grain boundary corrosion. Compared with the corrosion behaviors at 600 K and 640 K, temperature plays an important role in the corrosion behaviors of 304SS in static liquid Li. The weight loss, corrosion depth and corrosion products of 304SS specimens increase with the corrosion temperature. In general, the compatibility between 304SS and static liquid Li is relatively good under the experimental conditions. And besides, it is unexpectedly found that the compatibility of copper with Li is not good.

304SS↗

One-dimensional heterocyclic carbene–Au metal–organic frameworks bridging ultra-high vacuum models and scalable liquid-phase growth

The controlled design of molecule–metal interfaces is central to the development of functional nanomaterials for catalysis, sensing, and molecular electronics. Here we show that the adsorption of a Janus-type diimidazolium precursor on gold yields one-dimensional (1D) N-heterocyclic carbene (NHC)–Au–NHC metal organic frameworks (MOFs) featuring positively charged gold nodes. Using synchrotron X-ray photoemission spectroscopy (XPS), near edge X-ray adsorption fine structure (NEXAFS) spectroscopy and scanning tunnelling microscopy (STM), we demonstrate that thermal activation promotes counterion removal and drives the formation of extended 1D arrays, characterized by ∼1.0 nm Au–Au spacing and adatom densities up to 0.6 atom nm −2 (∼4% of surface atoms). Importantly, we translate this ultra-high vacuum (UHV) benchmark into a scalable solution-phase protocol in ethanol, enabling 1D-MOF growth under mild, base-free, open-air conditions. The resulting films retain structural and electronic signatures of UHV-grown systems, bridging model studies and practical synthesis. This approach establishes NHC–metal frameworks as accessible, tunable platforms for catalysis and materials design.

Gold adatoms↗

Preparation of a membrane-sealed cell for studying catalyst nanoparticles in flowing gas with high vacuum x-ray photoelectron spectrometer

Here a sealing-style x-ray photoelectron spectroscopy study of the surface of a 1.0 wt. %Ni/TiO2 nanoparticle catalyst in a flowing mixture of CO and O2 at 1 bar was performed with a graphene membrane-sealed Si3N4 window-based miniature cell. We report the details on how a commercial Si3N4 window is modified before assembling a graphene membrane, how single-layer graphene membranes are transferred from their metal supports to the modified Si3N4 window, how a modified Si3N4 window covered with a double-layer graphene membrane is assembled onto a blank cell cap, how a nanoparticle catalyst is introduced to the cell cap and then the cell cap is installed onto a cell body to form a complete reaction cell, and how a complete cell is interfaced with a high vacuum chamber of an XPS system before an XPS study of 1.0 wt. %Ni/TiO2 catalyst surface in a flowing mixture for 0.2 bar CO and 0.8 bar O2 is performed. How the characterization of a catalyst using this type of graphene membrane-sealed Si3N4 window-based miniature cell is relevant to the finding of the actual surface chemistry of a catalyst during catalysis is discussed.

Instruments & Instrumentation↗

High Temperature High Vacuum Mechanical Property Assessment of Zirconium Nuclear Fuel Cladding

This report presents the mechanical characterization of a specific Zry-4 cladding batch serving as the foundation for a diverse range of fuel performance research at Oak Ridge National Laboratory (ORNL). This effort supports research needs for the U.S. Department of Energy (DOE), particularly regarding evaluating accident tolerant fuel (ATF) cladding coating concepts, expanding understanding of cladding response to loss-of-coolant accidents (LOCA) transients, refining post-critical heat flux (CHF) limits (t@T), and upcoming irradiation campaigns. The central objective was to define the baseline performance of the substrate Zircaloy-4 (Zry-4) material leveraged across ORNL Advanced Fuel Campaign (AFC) efforts through controlled high-temperature vacuum tensile testing. This work begins to address gaps in existing models where implementation based on nominal heat-treatment labels, such as stress relief annealed (SRA), often fail to capture the interplay of recovery, recrystallization, and grain growth. To quantify this, data was benchmarked against the Pacific Northwest National Laboratory (PNNL) stress strain model to determine where this material falls in comparison to assumed values for materials in the same heat treatment regime. Analysis of the tensile data revealed that this specific SRA batch exhibits a transitional microstructural state best described by an effective cold-work (CW) parameter of 0.09, diverging from the previous estimation of 0.5 for SRA materials. Additionally, comparative testing of Cr coated specimens demonstrated no distinct difference in axial strength relative to the bare substrate. This suggests that the strengthening benefits of Cr coatings observed in burst scenarios are driven by residual stress mechanisms acting solely in the hoop direction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion trap with in-vacuum high numerical aperture imaging for a dual-species modular quantum computer

Photonic interconnects between quantum systems will play a central role in both scalable quantum computing and quantum networking. Entanglement of remote qubits via photons has been demonstrated in many platforms; however, improving the rate of entanglement generation will be instrumental for integrating photonic links into modular quantum computers. We present an ion trap system that has the highest reported free-space photon collection efficiency for quantum networking. We use a pair of in-vacuum aspheric lenses, each with a numerical aperture of 0.8, to couple 10(1)% of the 493 nm photons emitted from a 138Ba+ ion into single-mode fibers. We also demonstrate that proximal effects of the lenses on the ion position and motion can be mitigated.

Instruments & Instrumentation↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗