Search NASA⌕ Search

SEARCH · Search NASA

Results for “High-density city”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Data-driven model for cross ventilation potential in high-density cities based on coupled CFD simulation and machine learning

Effective urban ventilation through decent urban planning and building design can alleviate the deterioration of the urban built environment. Furthermore, natural ventilation requirements and guidelines in current building codes and standards are either qualitative or quantitative but subject to an absolute indoor airspeed threshold without considering the outdoor wind environment. To fill this gap, this paper develops an urban-scale coupled indoor and outdoor computational fluid dynamics (CFD) model and defines a novel ventilation index to assess natural ventilation potential. The index considers wind environments of both indoor and outdoor spaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relationship Between Radiation Dose and Markers of Insulin Resistance and Inflammation in Atomic Bomb Survivors

Abstract Context In recent studies of childhood cancer survivors, diabetes has been considered a late effect associated with high therapeutic doses of radiation therapy. Our recent study of atomic bomb (A-bomb) survivors also suggested an association between radiation dose and diabetes incidence, with exposure city and age at exposure as radiation dose effect modifiers. Insulin resistance mediated by systemic inflammation and abnormal body composition has been suggested as a possible primary mechanism for the incidence of diabetes after total body irradiation; however, no studies have examined low to moderate radiation exposure (<4 Gy) and insulin resistance in A-bomb survivors. Objective To examine the association between radiation dose and markers of inflammation and insulin resistance. Methods This study investigated 3152 survivors who underwent a health examination between 2008 and 2012 and who were younger than 15 years at exposure. Multivariate linear regression analyses were used to evaluate the radiation effects on levels of markers of inflammation and insulin resistance. Results Radiation dose was significantly and positively associated with levels of C-reactive protein, triglycerides, homeostasis model assessment of β-cell function (HOMA-β), and HOMA of insulin resistance (HOMA-IR) after adjustment for relevant covariates including sex, city, and age at exposure. Adiponectin and high-density lipoprotein cholesterol levels were also associated significantly and negatively with radiation dose. However, city was not a dose modifier of the radiation response on these markers of inflammation and insulin resistance. Conclusion Insulin resistance might be a possible factor in radiation-related diabetes incidence in A-bomb survivors.

Endocrinology & Metabolism↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effectiveness of nature-based solutions to reduce flooding in Quad Cities Metro Area (QCMA) using SWMM-HEC based flood model

Nature-based solutions (NbS) have gained significant attention as strategies for addressing urban environmental challenges, particularly since the establishment of the UN Sustainable Development Goals (SDGs) for 2030. However, the current research on NbS for urban flood management lacks comprehensive methodological approaches for identifying suitable areas and evaluating their effectiveness across different urban settings. Here, this study attempts to fill this gap by proposing a methodological framework integrating multi-criteria analysis with a SWMM-HEC-based hydrologic and hydraulic (HH) model to assess the suitability of NbS for the Quad Cities Metro Area (QCMA), consisting of Davenport, Bettendorf, Moline, and Rock Island. Eight NbS options-green roofs, rain gardens, infiltration trenches, permeable pavements, vegetative swales, dry detention basins, retention ponds, and rain barrels/cisterns - were considered based on volumetric efficiency and runoff reduction efficiency. The study reveals that implementing the proposed NbS could have substantially reduced flood depths in key historical flood events by 21% in 1993, 15% in 2008, 16% in 2011, 23% in 2014, 40% in 2019, and 10% in 2023. The findings highlight a critical trade-off between peak runoff and NbS implementation: while NbS effectively reduce flood impacts, they also enhance volumetric efficiency by approximately 43%. In high-density areas of the QCMA, flood depth reductions of around 20% suggest that NbS are a viable solution for dense urban environments with limited space. This shows the potential for integrating NbS into existing infrastructure, offering a promising approach for cities facing increasing flooding risks. The proposed methodology provides a practical framework for incorporating NbS into urban stormwater management, addressing gaps in optimizing NbS performance, and offering a pathway to scale their application in other urban areas with various environmental and social contexts.

CMIP6↗

Computational investigation of water glasses using machine-learning potentials

The molecular origins of water’s anomalous properties have long been a subject of scientific inquiry. The liquid–liquid phase transition hypothesis, which posits the existence of distinct low-density and high-density liquid states separated by a first-order phase transition terminating at a critical point, has gained increasing experimental and computational support and offers a thermodynamically consistent framework for many of water’s anomalies. However, experimental challenges in avoiding crystallization near the postulated liquid–liquid critical point have focused attention to water’s canonical glassy states: low-density and high-density amorphous ice. Here, we use two Deep Potential machine-learning models, trained on the Strongly Constrained and Appropriately Normed density functional and the highly accurate Many-Body Polarizable potential, to conduct an investigation of water’s glassy phenomenology based on quantum mechanical calculations. Despite not being explicitly trained on amorphous ices, both models accurately capture the structure and transformation of the water glasses, including their interconversion along different thermodynamic paths. Isobaric quenching of liquid water at various pressures generates a continuum of intermediate amorphous ices and density fluctuations increase near the liquid–liquid critical pressure. The glass transition temperatures of the amorphous ices produced at different pressures exhibit two distinct branches, corresponding to low-density and high-density amorphous ice behaviors, consistent with experiment and the liquid–liquid transition hypothesis. Extrapolating transformation pressures from isothermal compressions to experimental compression rates brings our simulations into excellent agreement with data. Our findings demonstrate that machine-learning potentials trained on equilibrium phases can effectively model nonequilibrium glassy behavior and pave the way for studying long-timescale, out-of-equilibrium processes with quantum mechanical accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dust-void evolution driven by turbulent dust flux can induce runaway migration of Earth-mass planets

Torques from asymmetric dust structures (so-called dust-void and filamentary structures) formed around low-mass planets embedded in a nonturbulent dust-gas disk can exceed the torques produced by the gas disk component and then go on to dominate the planet’s orbital dynamics. Here, we investigate how these structures (hence the dust torque) change when the effect of turbulent dust diffusion and dust feedback are included, along with the direct implications on the migration of Earth-like planets. Using the FARGO3D code, we performed 2D and 3D multifluid hydrodynamic simulations, focusing on a non-migrating planet with a mass of M p = 1.5 M ⊕ in 2D and on migrating planets with M p ∈ [1.5, 12] M ⊕ in 3D. We varied the δ-dimensionless diffusivity parameter in the range [0, 3 × 10 −3 ] and considered three different Stokes numbers, St = {0.04, 0.26, 0.55}, which are representative of the gas-dominated, the transitional, and the gravity-dominated regimes, respectively. In our 2D models, we find that turbulent diffusion of dust prevents the formation of the dust-void and filamentary structures when δ > 3 × 10 −4 . Otherwise, dust structures survive turbulent diffusion flow. However, dust and total torques become positive only in transitional and gravity-dominated regimes. In our 3D models, we find that the dust-void is drastically modified and the high-density ring-shaped barrier delineating the dust-void disappears if δ ≳ 10 −4 , due to the effect of dust turbulent diffusion along with the back-reaction of the dust. For all values of δ, the filament in front of the planet is replaced by a low-density trench. Remarkably, as we have allowed the planets to migrate, the evolving dust-void can drive either runaway migration or outward (inward) oscillatory-torque migration. Our study thus suggests that low-mass Earth-like planets can undergo runaway migration in dusty disks.

79 ASTRONOMY AND ASTROPHYSICS↗