Calculation of molecular formulas in high-resolution mass spectrometry
Algorithm, decimal weights, and molecular formulas calculated by computer for high-resolution mass spectrometry application
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Algorithm, decimal weights, and molecular formulas calculated by computer for high-resolution mass spectrometry application
Complex organic compounds analysis by fast- electrical-scanning high resolution mass spectrometry and gas chromatography
Mass spectrometric analysis of major modes of decomposition of sesquiterpenol widdrol
Basic nitrogenous compounds isolated from extracts of Green River Formation oil shale were analyzed. The major homologous constituents found were the compositional types - namely, quinolines, tetrahydrequinolines with minor amounts of pyridines and indoles series and traces of more aromatized nitrogen compounds. These results are correlated with nitrogen compounds isolated from Green River Formation retort oil and are a survey of the unaltered nitrogen compounds indigeneous to the shale.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The presence, origin and implications of carbynes in meteorites are investigated. A sample of the Allende meteorite was pyrolyzed at temperatures from 25 to 750 C and examined by solid probe time-of-flight mass spectrometry and high-resolution mass spectrometry. Fragments released upon heating at 250 to 330 C are found to be composed of macromolecules containing triply bonded carbon units and cyanoacetylenes, as well as some methyl- and phenylacetylenes. Although carbynes are well known to form from the condensation of carbon vapors above 2600 K or by shock greater than 600 kbar, which would be unlikely in Allende, it is found that carbynes rather than graphite are formed metastably by the disproportionation of CO at low temperatures when chromite is present as a catalyst. Results imply that metastable formation mechanisms may be the principal source of interstellar polycyanoacetylenes and meteoritic and terrestrial carbynes.
Electron-impact induced fragmentations of o-, m-, and p-hydroxyalkylphenones and their trimethylsilyl (TMS) ethers are studied by means of high-resolution mass spectrometry, metastable defocusing, and deuterium labeling of the TMS ether derivatives. A markedly increased methyl radical loss from the o-TMS ether is attributed to a proximity effect. Minor fragmentation was observed with m- and p-isomers. Significantly intense doubly-charged ions were formed from ketonic cleavage and by the loss of a TMS methyl radical. The sequence of fragmentation was found to depend on the size of the alkyl group attached to the ketone carbonyl.
The mass spectra of twenty alkyl carbamates derived from primary, secondary, and tertiary alcohols are investigated, using deuterium labeling and high-resolution mass spectrometry. Several of the primary and secondary alcohol derivatives are found to yield an ion formally equivalent to the product ion of a McLafferty rearrangement. Deuterium labeling, however, revealed a lack, in these carbamate derivatives, of the usual site specificity associated with the McLafferty rearrangement. A double hydrogen rearrangement process was observed in the mass spectra of several carbamates derived from tertiary alcohols.
As part of the U.S. EPA Dioxin Reassessment Program, the 2,3,7,8-chlorine-substituted dibenzo-p-dioxins and furans were measured at part per trillion (ppt) levels in beef fat collected from slaughter facilities in the United States. This is the first statistically designed national survey of these compounds in the U.S. beef supply. Analyte concentrations were determined by high-resolution gas chromatography/high-resolution mass spectrometry, using isotope dilution methodology. Method limits of detection on a whole weight basis were 0.05 ppt for TCDD and 0.10 ppt for TCDF, 0.50 ppt for the pentas (PeCDDs/PeCDFs)/hexas (HxCDDs/HxCDFs)/heptas (HpCDDs/HpCDFs), and 3.00 ppt for the octas (OCDD/OCDF). Method detection and quantitation limits were established on the basis of demonstrated performance criteria utilizing fortified samples rather than by conventional signal-to-noise or variability of response methods. The background subtraction procedures developed for this study minimized the likelihood of false positives and increased the confidence associated with reported values near the detection limits. Mean and median values for each of the 2,3,7,8-Cl-substituted dioxins and furans are reported, along with the supporting information required for their interpretation. The mean toxic equivalence values for the samples are 0.35 ppt (nondetects = 0) and 0.89 ppt (nondetects = 1/2 LOD).
Evaluating the distribution and diversity of solvent-soluble organic molecules in extraterrestrial materials provide information about the physicochemical environments where prebiotic chemistry occurred and is essential for assessing the inventory of prebiotic compounds available to the early Earth. In this work, we conducted a comprehensive molecular characterization of solvent-soluble organic compounds in a homogenized aggregate sample (ID: OREX-800107-128) of unsorted regolith from asteroid (101955) Bennu returned by NASA’s OSIRIS-REx mission. Using two-dimensional gas chromatography coupled with high-resolution time-of-flight mass spectrometry (GC×GC-HRMS), we identified 87 organic compounds across several molecular classes, including alkanes, polycyclic aromatic hydrocarbons, and nitrogen-, oxygen-, and sulfur-bearing species. Comparison with the organic inventory of CI (Orgueil), C2-ungrouped (Tagish Lake and Tarda), and CM2 (Murchison) carbonaceous chondrites revealed that Bennu sample OREX-800107-128 is most similar to Tagish Lake and Tarda yet compositionally distinct from all of these meteorites. This Bennu sample exhibits a relatively high abundance of low-molecular-weight aromatics (e.g., toluene), pyridine derivatives, and sulfur species such as dimethyl sulfite, consistent with episodic low-temperature aqueous alteration. The presence of these organic compounds suggests that this material experienced chemically diverse processes in the parent body conducive to complex organic synthesis, including aldol condensation reactions responsible for N- and O-bearing compounds. We also compared the molecular distributions of this Bennu sample and previously analyzed samples from (162173) Ryugu to assess potential common origins between these two carbonaceous asteroids. Bennu shows more chemically diverse and nitrogen-rich organic materials than Ryugu. While both asteroids share broadly similar primitive compositions, the observed chemical differences indicate distinct evolutionary histories within a likely common formation environment though whether Bennu and Ryugu derive from a single compositionally heterogeneous parent body or from multiple closely related progenitors remains unresolved. Further detailed comparative analyses of material from Bennu, Ryugu, and specific carbonaceous meteorites (e.g., Tagish Lake and Tarda) will provide new insights into how the N-rich molecular profile observed in Bennu samples was formed and evolved in the outer Solar System.
Understanding the behaviour of siderophile elements during cooling of iron meteorites can lead to insight into the general thermal histories of the meteorites as well as their respective parent bodies. Traditionally trace element analyses in meteorites have been done using techniques that only measure the average concentration in each phase. With these methods, all of the spatial information with respect to the distribution of an element within one phase is lost. Measuring concentration profiles of trace elements in meteorites is now possible, with the advent of high-resolution analytical techniques such as laser ablation, inductively coupled plasma mass spectrometry (LA-ICP-MS) with spatial resolution <20 microns. [e.g. 1,2] and secondary ion mass spectrometry [3]. These profiles can give more insight into both the partitioning and diffusive behavior of siderophile elements in metal systems relevant to iron meteorites, as well as parent body cooling rates.
It is believed that Earth, Venus, and Mars were formed by the same rocky and icy planetesimals, which resembled meteorites and comets in their composition, respectively. These planets are thus expected to have initially had the same chemical and isotope composition. Scaling the mass of the terrestrial ocean by the planetary mass ratio, the expected initial H2O abundance on Mars is a layer of about 1 km thick. Scaling the abundance of CO2 on Venus, the expected initial CO2 abundance on Mars is 15 bars. Evidently, significant parts of the initial H2O and CO2 abundances have been lost. Intense meteorite impact erosion and hydrodynamic escape of hydrogen (which could drag to escape more heavy species) were dominant loss processes in the first 0.8 Byr. Later, atmospheric sputtering by O+ ions resulted in the dissociation of CO2 and massive losses of O, C, and H. Formation of carbonates also reduced CO2 to its present abundance which currently exists in the atmosphere, on the polar caps, and is absorbed by regolith. Water loss is currently due to thermal escape of H and nonthermal escape of O, both formed by photodissociation of H2O. All loss processes resulted in fractionation of the H, O, and C isotopes. Therefore, the current isotope ratios in H2O and CO2 are clues to the history of volatiles on Mars. There are three tools to study H2O and CO2 isotopes in the martian atmosphere: (i) mass spectrometry from landing probes, (ii) analyses of Mars' gases trapped in the SNC meteorites which were ejected from Mars, and (iii) high-resolution spectroscopy of the H2O andCO2 bands. Method (i) is the best but is the most expensive. Mass spectrometers to be used should be designed for high-precision isotope measurements. Method (ii) makes it possible to reach an uncertainty +/- 0.1%. However, the obtained results are affected by some uncontrolled interactions: isotope fractionations of (1) trapped gases and (2) those released in pyrolysis, (3) contribution of the impactor, isotope exchanges (4) in the terrestrial environment and (5) with the host rock during pyrolysis. Therefore, the spectroscopic data are of great interest, though their formal accuracy is lower. High-resolution spectroscopy is also a tool to study the current atmosphere of Mars by mapping of some photochemically important species and searching for some minor constituents and their variations. Additional information is contained in the original extended abstract.
The primary goal of our research in this program is to develop new techniques for the analysis of volatile trace elements in very small samples using inductively coupled plasma mass spectrometry (ICP-MS) in preparation for samples returned by the Stardust mission. The instrument that will serve as the basis of our experiments is the ELEMENT2 high-resolution ICP-MS. We have spent the past year designing the laboratory to house this instrument as well as space to store and prepare samples returned by the Stardust mission. Unfortunately, the location that we had initially selected for the instrument turned out to be insufficient for our needs. This was determined almost eight months into the first year of our funding cycle, after extensive work including the production of engineering drawings. However, during this time the Lunar and Planetary Laboratory was selected to lead Phoenix, the first Mars Scout mission. As a result of this award LPL purchased a new, 50,000 square foot building. We have acquired 1400 square feet of laboratory space in this new facility. Four-hundred square feet will be used for a class-100 clean room. This area is designated for storage and preparation of extraterrestrial materials. The additional 1000 square feet will house the ELEMENT2 ICP-MS and peripheral devices. This is an enormous amount of space for this instrument, but it provides plenty of room for expansion in the future. The ICP-MS and the clean room facilities have been purchased. The instrument has been delivered. The startup time for this instrument is relatively short and we expect to be collecting our first data by mid-summer.
Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.
A minature quadrupole mass-spectrometer array consisting of 16 rods in a 4X4 array is reported.
The volatile organic components in the spacecraft cabin atmosphere of Skylab 4 were trapped on a solid adsorbent at various times during the mission. In post-flight analyses, more than 300 compounds in concentrations from less than 1 ppb up to 8000 ppb could be detected by high-resolution gas chromatography. In the samples of the 11th, 47th, and 77th day of the mission, approximately 100 components in the molecular weight range from 58 to 592 were identified by mass spectrometry. Besides components known from other environments, such as alkanes, alkenes, and alkylated aromatic hydrocarbons, components typical of the human metabolism, such as ketones and alcohols, were found. Other typical components in the spacecraft atmosphere included fluorocarbons and various silicone compounds, mostly normal and cyclic methylsiloxanes.