Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hodge decomposition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Imposing equilibrium on experimental 3-D stress fields using Hodge decomposition and FFT-based optimization

Here, we present a methodology to impose micromechanical constraints, i.e. stress equilibrium at grain and sub-grain scale, to an arbitrary (non-equilibrated) voxelized stress field obtained, for example, by means of synchrotron X-ray diffraction techniques. The method consists in finding the equilibrated stress field closest (in L 2 -norm sense) to the measured non-equilibrated stress field, via the solution of an optimization problem. The extraction of the divergence-free (equilibrated) part of a general (non-equilibrated) field is performed using the Hodge decomposition of a symmetric matrix field, which is the generalization of the Helmholtz decomposition of a vector field into the sum of an irrotational field and a solenoidal field. The combination of: a) the Euler–Lagrange equations that solve the optimization problem, and b) the Hodge decomposition, gives a differential expression that contains the bi-harmonic operator and two times the curl operator acting on the experimental stress field. These high-order derivatives can be efficiently performed in Fourier space. The method is applied to filter the non-equilibrated parts of a synthetic piecewise constant stress fields with a known ground truth, and stress fields in Gum Metal, a beta-Ti-based alloy measured in-situ using Diffraction Contrast Tomography (DCT). In both cases, the largest corrections were obtained near grain boundaries.

36 MATERIALS SCIENCE↗

Nonlinear beam kinematics by decomposition of the rotation tensor

A simple matrix expression is obtained for the strain components of a beam in which the displacements and rotations are large. The only restrictions are on the magnitudes of the strain and of the local rotation, a newly-identified kinematical quantity. The local rotation is defined as the change of orientation of material elements relative to the change of orientation of the beam reference triad. The vectors and tensors in the theory are resolved along orthogonal triads of base vectors centered along the undeformed and deformed beam reference axes, so Cartesian tensor notation is used. Although a curvilinear coordinate system is natural to the beam problem, the complications usually associated with its use are circumvented. Local rotations appear explicitly in the resulting strain expressions, facilitating the treatment of beams with both open and closed cross sections in applications of the theory. The theory is used to obtain the kinematical relations for coupled bending, torsion, extension, shear deformation, and warping of an initially curved and twisted beam.

Danielson, D. A.↗

Nonlinear Beam Kinematics by Decomposition of the Rotation Tensor

A simple matrix expression is obtained for the strain components of a beam in which the displacements and rotations are large. The only restrictions are on the magnitudes of the strain and of the local rotation, a newly-identified kinematical quantity. The local rotation is defined as the change of orientation of material elements relative to the change of orientation of the beam reference triad. The vectors and tensors in the theory are resolved along orthogonal triads of base vectors centered along the undeformed and deformed beam reference axes, so Cartesian tensor notation is used. Although a curvilinear coordinate system is natural to the beam problem, the complications usually associated with its use are circumvented. Local rotations appear explicitly in the resulting strain expressions, facilitating the treatment of beams with both open and closed cross sections in applications of the theory. The theory is used to obtain the kinematical relations for coupled bending, torsion extension, shear deformation, and warping of an initially curved and twisted beam.

Danielson, D. A.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗