Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hot Salt Tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Hypothesis of Hot Tank Failure

Work has begun on a Design Basis Document / Owner’s Technical Specification for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. A principal topic of recent interest is the failures of the hot salt tanks in central receiver projects. The paper outlines a hypothesis for the source of the failures, and discusses a range of possible solutions.

14 SOLAR ENERGY↗

Modeling of Stress Distribution in Molten Salt Thermal Energy Storage Tanks for In-Service Central Receiver Power Plants

Failures in molten nitrate salts thermal energy storage tanks (TES) have been occurring in several concentrating solar power (CSP) plants around the world after a few months or years of operation. These failures are mainly related to a combination of high stress, corrosion, large deformation, and thermal cycling. Most of these failures are a consequence of the infancy of this technology; technical standards for design, fabrication, implementation, and operation of molten salt tanks operating at temperatures up to 565 degrees Celsius do not exist and most of current in-service tanks have been designed using the recommendations from the American Petroleum Institute (API) 650 and the American Society of Mechanical Engineers ASME section II standards, which are applicable for TES tanks operating at lower temperatures. We have developed a 3-dimensional model of a representative molten salt hot tank design that uses typical CSP plant operation conditions and allows determining the temperature and stress distribution in the tank. The model also considers the initial floor residual stresses and distortion after its welding fabrication. We have identified critical thermal gradients in the tank floor and shell and locations in the tank where the stresses are high and could become susceptible points for failure.

concentrating solar power↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Mechanical Failure Risk Management for In-Service CSP Nitrate Hot Tanks

The hot thermal energy storage tanks in many operating (Gen2) concentrating solar power plants are designed to contain molten nitrate solar salt at 565 Degrees Celsius and are constructed from 347H stainless steel (SS). From previous work, it is known that 347H SS weldments are potentially susceptible to stress-relaxation cracking (SRC), particularly in the heat-affected zone above 540 Degrees Celsius when no post-weld heat-treatment (PWHT) is performed. However, residual stresses can be reduced when weldments receive PWHT, while at the same time a crack-resistant microstructure is being generated. The overarching goal of this project was to optimize cost-effective, thickness-dependent, localized PWHT procedures and to investigate for feasible non-destructive evaluation (NDE) at commercial scale for hot tanks in Gen2 CSP using 347H SS.

14 SOLAR ENERGY↗

Understanding failure in austenitic steels: Key considerations for molten salt storage in CSP applications

Owing to their excellent properties, austenitic stainless steels are extensively used in boilers, furnaces, molten salt tanks, and other applications that are subjected to extreme mechanical loads and high-temperature conditions. Their high corrosion and creep resistance make them suitable for high-temperature operating environments. Additionally, good fatigue resistance and favorable mechanical and visual properties are essential. However, the premature failure of several components at elevated temperatures has been previously reported. Although the failure analysis of components in service is complex, processes such as cold work and welding have been identified as contributing factors to the performance degradation of these steels. This study aims to analyze the various documented failure modes and mechanisms in austenitic steels, including creep, cracking, stress relaxation cracking, and fatigue, to better understand the multi-objective design requirements for these alloys as structural materials for high-temperature molten salt tanks in Concentrating Solar Power (CSP) plants. Stabilized austenitic grades, such as AISI 347H, demonstrate superior resistance to creep and corrosion-related degradation when compared to non-stabilized grades like AISI 316L at temperatures relevant to concentrated solar power (CSP) applications. In contrast, nickel-based alloys offer enhanced corrosion resistance, albeit at a higher cost. This review underscores that creep, stress relaxation cracking, and thermo-mechanical fatigue are the predominant long-term failure risks in CSP hot tanks.

14 SOLAR ENERGY↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗