Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hot-Humid Climate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the energy equity benefits of energy storage solutions

Safety, reliability, efficiency, and affordability are no longer the sole tenets of electric grid planning. The evolving social and policy climate have placed new explicit requirements on the electric grid, including resilience, decarbonization, and energy equity and justice. Integrating energy equity strategies into modern grid design is intended to achieve a fair and just distribution of benefits within the energy system. This study aims to characterize the energy equity and community benefits of energy storage systems (ESS) under the following three use-case models: utility ESS that are operated within the distribution system; community-owned ESS; and behind-the-meter ESS that are customer-owned to serve the household. The goal of this energy equity analysis is to characterize the environmental, economic, and social benefits of ESS through applied metrics such as energy burden, energy poverty, energy vulnerability, job creation, and more. A 13.8 kV, 265 node representative feeder corresponding to the hot-humid climate of Louisiana, chosen for its high energy burden, frequent hurricanes and outage events, was used to perform a storage adequacy analysis for six different outage scenarios to determine energy storage access for each use-case. The results of this analysis are then used to characterize both the grid and equity benefits of storage solutions to inform a prioritization framework matching community needs with system preferences for utility planning processes, market regulations, and the wider network of energy system stakeholders.

Energy Equity, energy justice, equity, reliability↗

Potential induced degradation in c-Si glass-glass modules after extended damp heat stress

Traditional Glass-Backsheet (GB) photovoltaic (PV) modules have been the industry standard for a long time, but the Glass-Glass (GG) modules are quickly rising in popularity. PV modules installed in hot-humid climates with high string voltages can undergo potential induced degradation (PID). So far, to the best of our knowledge, only fresh modules with strong interfacial adhesion have been investigated for PID. However, in reality, the PV modules have weak interfacial adhesion after a few years of field exposure. Therefore, it is essential to evaluate PV modules with weakened interfaces. In this study, we investigated the PID susceptibility of PV modules with weakened interfaces after subjecting them to 2000 hours of damp heat (DH2000) at 85°C/85% relative humidity (RH) in an accelerated environmental chamber. Fresh GG modules were also stressed for PID to compare with PID degradation of DH-stressed modules. Pre- and post-characterization tests were done before, between, and after each stress method to determine the changes in electrical performance, cell metallization properties, and hotspot properties. It is observed that fresh GG modules showed little/no degradation (less than 1%) in maximum power (Pmax), whereas the GG modules that underwent sequential DH and PID degraded by 11% to 12%. Potential mechanisms for these degradations are also presented. Furthermore, the results presented in this study are critical for the industry, considering that the bifacial modules with GG construction will be dominant in the next 10 years.

14 SOLAR ENERGY↗

Enhanced surface urban heat islands due to divergent urban-rural greening trends

Abstract Satellite observations show that the surface urban heat island intensity (SUHII) has been increasing over the last two decades. This is often accompanied by an increased urban-rural contrast of vegetation greenness. However, the contribution of uneven vegetation trends in urban and rural areas to the trend of SUHII is unclear, due to the confounding effects of climate change and changes in man-made infrastructures and anthropogenic heat sources. Here we use a data-model fusion approach to quantify such contributions during the peak growing season. We show that the LAI dif (the urban-rural difference of leaf area index) is increasing ( P < 0.05) in 189 of the selected 228 global megacities. The increasing trend of LAI dif from 2000 to 2019 accounts for about one quarter of the trend in satellite-derived SUHII, and the impact is particularly evident in places with rapid urbanization and rural cropland intensification. The marginal sensitivity of SUHII to LAI dif is the strongest in hot-humid megacities surrounded by croplands and in hot-dry megacities surrounded by mixed woody and herbaceous vegetation. Our study highlights the role of long-term vegetation trends in modulating the trends of urban-rural temperature differences.

54 ENVIRONMENTAL SCIENCES↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗