Search NASA⌕ Search

SEARCH · Search NASA

Results for “Humanoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Remotely Teleoperating a Humanoid Robot to Perform Fine Motor Tasks with Virtual Reality - 18446

In this paper, we describe our ongoing work to develop cooperative control of NASA's R5 Valkyrie humanoid robot for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. These tasks can be physically demanding and provide some element of risk to the operator when done by a person in situ. For example, if a glove is ruptured, the operator could be exposed to radioactive material. In many cases, the operator has low visibility and is unable to reach the entire task space, requiring the use of additional tools located inside the glovebox. Such tasks include cleaning particulate from inside the glovebox via sweeping or vacuuming, separating a specific amount of a compound to be weighed on a scale, or grasping and manipulating objects inside the glovebox. There is potential to move the operator to a nearby, safe location and instead place a humanoid robot in the potentially hazardous environment. However, teleoperating a humanoid robot to perform dexterous tasks at a comparable level to a human hand remains a difficult problem. Previous work for controlling humanoid robots often involves one or more operators using a standard 2D display with a mouse and keyboard as controllers. Successful interfaces use sensor fusion to provide information to the operator for increased situation awareness, but these designs have limitations. Gaining proper situation awareness by visualizing 3D information on a 2D screen requires time and increases the cognitive load on the user. Instead, if the operator is able to visualize and control the robot properly in three dimensions, it can increase situation and task awareness, reduce task time, reduce the chance of mistakes, and increase the likelihood of overall task success. We propose a two-part system that combines an HTC Vive virtual reality headset with either the Vive handheld controllers, or the Manus VR wearable gloves as the primary control. The operator wears the headset in a remote location and can visualize a reconstruction of the glovebox, created live by sensor scans from the robot and with sensors located inside the glovebox for a perspective traditionally unavailable to operators. By using the controllers or gloves to control the humanoid robots hands directly, they can plan actions in the virtual reconstruction. When the operator is satisfied with the plan, the actions are sent to the real robot. To test this system we have created a mockup of a glovebox that is accessible by Valkyrie, as well as several tasks that are a subsample of the tasks that might be required when working in a real glovebox. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CRCNS21 Computational Models of Multisensory Integration by Upper Limb in Humanoids and Amputees

This international collaborative research project between Johns Hopkins University (JHU) and the Technical University of Munich (TUM) investigated how the human brain processes and integrates multiple types of sensory information, such as touch and force, with the goal of improving prosthetic limbs for amputees and advancing sensory capabilities in humanoid robots. The research advanced our understanding of how the brain responds to sensory feedback in upper-limb amputees. Through experiments in which amputees received electrical stimulation while performing phantom hand movements, we demonstrated that sensory feedback activates the cortical sensorimotor and multisensory regions, and that these regions communicate dynamically during stimulation. Experiments with intact-limb participants explored the integration of visual, haptic, and force feedback, as well as in virtual reality motor training, further showing how the brain processes multimodal sensory information. In addition, this research inspired work on examining the reliability of where amputees perceive sensations over time, which contributed to a successful doctoral fellowship for continued investigation. Our collaborators at TUM improved multimodal sensor technology combining tactile and thermal feedback for humanoid robots, demonstrating the feasibility of integrating multiple sensor types into a unified system for detecting and responding to environmental stimuli. The experimental methods and analysis techniques developed across both teams, including functional network analysis and multimodal sensor integration, provide a foundation for future research in prosthetics and robotics. This research benefits the public by generating knowledge about how amputees process restored sensory information. Advances in humanoid sensing contribute to safer human-robot interaction. The project also fostered international collaboration and cross-disciplinary training: one TUM doctoral student spent a summer at JHU working on multimodal sensor integration, while two JHU students traveled to TUM to host workshops on neuromorphic sensory encoding and sensory integration.

42 ENGINEERING↗

Combining gait optimization with passive system to increase the energy efficiency of a humanoid robot walking movement

There are several approaches to create the Humanoid robot gait planning. This problem presents a large number of unknown parameters that should be found to make the humanoid robot to walk. Optimization in simulation models can be used to find the gait based on several criteria such as energy minimization, acceleration, step length among the others. The energy consumption can also be reduced with elastic elements coupled to each joint. The presented paper addresses an optimization method, the Stretched Simulated Annealing, that runs in an accurate and stable simulation model to find the optimal gait combined with elastic elements. Final results demonstrate that optimization is a valid gait planning technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom

Purpose: To avoid complications in total body irradiation (TBI), it is important to achieve a homogeneous dose distribution throughout the body and to deliver a correct dose to the lung which is an organ at risk. The purpose of this work was to validate the TBI dose protocol and to check the accuracy of the 3D dose calculations of the treatment planning system. Methods: Dosimetry based on alanine/electron paramagnetic resonance (EPR) was used to measure dose at numerous locations within an anthropomorphic phantom (Alderson) that was irradiated in a clinical TBI beam setup. The alanine EPR dosimetry system was calibrated against water calorimetry in a Co-60 beam and the absorbed dose was determined by the use of ''dose-normalized amplitudes'' A{sub D}. The dose rate of the TBI beam was checked against a Farmer ionization chamber. The phantom measurements were compared to 3D dose calculations from a treatment planning system (Pinnacle) modeled for standard dose calculations. Results: Alanine dosimetry allowed accurate measurements which were in accordance with ionization chamber measurements. The combined relative standard measurement uncertainty in the Alderson phantom was U{sub r}(A{sub D})=0.6%. The humanoid phantom was irradiated to a reference dose of 10 Gy, limiting the lung dose to 7.5 Gy. The ratio of the average measured dose midplane in the craniocaudal direction to the reference dose was 1.001 with a spread of {+-}4.7% (1 sd). Dose to the lung was measured in 26 locations and found, in average, 1.8% lower than expected. Lung dose was homogeneous in the ventral-dorsal direction but a dose gradient of 0.10 Gy cm{sup -1} was observed in the craniocaudal direction midline within the lung lobe. 3D dose calculations (Pinnacle) were found, in average, 2% lower compared to dose measurements on the body axis and 3% lower for the lungs. Conclusions: The alanine/EPR dosimetry system allowed accurate dose measurements which enabled the authors to validate their TBI dose protocol. Dose calculations based on a collapsed cone convolution dose algorithm modeled for regular treatments are accurate within 3% and can further be improved when the algorithm is modeled for TBI.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards Cooperative Control of Humanoid Robots for Handling High-Consequence Materials in Gloveboxes - 17291

In this paper, we describe our ongoing work with NASA's Valkyrie humanoid robot and present preliminary results on cooperative control of Valkyrie's hands for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. First, we discuss our human-supervised robot control framework which is based on optimization-based whole-body motion and manipulation controllers. A key aspect of this approach is perception based grasping. We develop a grasping control module for realizing the grasps corresponding to sample tasks such as power, ball, key, pinch, and open palm grasps and their variations. Next, we introduce the notion of motion template library in order to develop generalizable robot grasping and manipulation. Motion template library stores the constraint setting information for the constrained motion planning methods and a framework which can implement the motion template library on different types of robots for accomplishing similar tasks. Motion templates are defined only based on the task requirements. As a result, they can be easily ported to different robot platforms. Lastly, we discuss our multi-modal interfaces designs which include a visual display for improved situational awareness as well as a tactile glove for robot hand control and feedback. Our goal is for the person tele-operating the Valkyrie robot to have better sensing and control than what he or she would have if actually standing at the glovebox doing the work. This improved sensing is comprised of the ability to 'see through' the robot's arms and hands in the gloves and to have an improved sense of touch. The paper concludes with a discussion of our validation strategy. Our success metrics are derived from the completion of a relatively complex experiment to be performed in the glovebox. We evaluate various realistic experiments and use them for task validation and demonstration with Valkyrie. We use speed, time of completion, accuracy, repeatability and reliability rates as success metrics by designing replicable experiments. (authors)

42 ENGINEERING↗

Integrating Risk in Humanoid Robot Control for Applications in the Nuclear Industry - 18230

This paper discuss the integration of risk into a robot control framework for decommissioning applications in the nuclear industry. Our overall objective is to allow the robot to evaluate a risk associated with several methods of completing the same task by combining a set of action sequences. If the environment is known and in the absence of sensing errors each set of actions would successfully complete the task. In this paper, instead of attempting to model the errors associated with each sensing system in order to compute an exact solution, a set of solutions are obtained along with a prescribed risk index. The risk associated with each set of actions can then be compared to possible payoffs or rewards, for instance task completion time or power consumption. This information is then sent to a high level decision planner, for instance a human teleoperator, who can then make a more informed decision regarding the robots actions. In order to illustrate the concept, we introduce three specific risk measures, namely, the collision risk and the risk of toppling and failure risk associated with grasping an object. We demonstrate the results from this foundational study of risk-aware compositional robot autonomy in simulation using NASA's Valkyrie humanoid robot, and the grasping simulator HAPTIX. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Achieving Versatile Energy Efficiency With the WANDERER Biped Robot

Legged humanoid robots promise revolutionary mobility and effectiveness in environments built for humans. However, inefficient use of energy significantly limits their practical adoption. The humanoid biped walking anthropomorphic novelly-driven efficient robot for emergency response (WANDERER) achieves versatile, efficient mobility, and high endurance via novel drive-trains and passive joint mechanisms. Results of a test in which WANDERER walked for more than 4 h and covered 2.8 km on a treadmill, are presented. Results of laboratory experiments showing even more efficient walking are also presented and analyzed in this article. WANDERER's energetic performance and endurance are believed to exceed the prior literature in human-scale humanoid robots. This article describes WANDERER, the analytical methods and innovations that enable its design, and system-level energy efficiency results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An online x-ray based position validation system for prostate hypofractionated radiotherapy

Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images. Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition

Purpose: A common approach for dose assessment during cone beam computed tomography (CBCT) acquisition is to use thermoluminescent detectors for skin dose measurements (on patients or phantoms) or ionization chamber (in phantoms) for body dose measurements. However, the benefits of a daily CBCT image acquisition such as margin reduction in planning target volume and the image quality must be weighted against the extra dose received during CBCT acquisitions. Methods: The authors describe a two-dimensional reference dosimetry technique for measuring dose from CBCT scans using the on-board imaging system on a Varian Clinac-iX linear accelerator that employs the XR-QA radiochromic film model, specifically designed for dose measurements at low energy photons. The CBCT dose measurements were performed for three different body regions (head and neck, pelvis, and thorax) using humanoid Rando phantom. Results: The authors report on both surface dose and dose profiles measurements during clinical CBCT procedures carried out on a humanoid Rando phantom. Our measurements show that the surface doses per CBCT scan can range anywhere between 0.1 and 4.7 cGy, with the lowest surface dose observed in the head and neck region, while the highest surface dose was observed for the Pelvis spot light CBCT protocol in the pelvic region, on the posterior side of the Rando phantom. The authors also present results of the uncertainty analysis of our XR-QA radiochromic film dosimetry system. Conclusions: Radiochromic film dosimetry protocol described in this work was used to perform dose measurements during CBCT acquisitions with the one-sigma dose measurement uncertainty of up to 3% for doses above 1 cGy. Our protocol is based on film exposure calibration in terms of ''air kerma in air,'' which simplifies both the calibration procedure and reference dosimetry measurements. The results from a full Monte Carlo investigation of the dose conversion of measured XR-QA film dose at the surface into dose to water (or water kerma) at the surface of the phantom indicate that, for typical beam qualities used in CBCT, this conversion can be approximated by simple mass-energy absorption coefficient ratios water-to-air.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-G-TeP2-15: Feasibility Study of Fiber-Optic Cerenkov Radiation Sensors for in Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

Purpose: To evaluate the possibility of a fiber-optic Cerenkov radiation sensor (FCRS) for in vivo dose verification in proton therapy. Methods: The Cerenkov radiation due to the proton beam was measured using a homemade phantom, consisting of a plastic optical fiber (POF, PGSCD1001-13-E, Toray, Tokyo, Japan) connected to each channel of a multianode photomultiplier tube (MAPMT:H7546, Hamamatsu Photonics, Shizuoka, Japan). Data were acquired using a multi-anode photomultiplier tube with the NI-DAQ system (National Instruments Texas, USA). The real-time monitoring graphic user interface was programmed using Labview. The FCRS was analyzed for its dosimetrics characteristic in proton beam. To determine the accuracy of the FCRS in proton dose measurements, we compared the ionization chamber dose measurements using a water phantom. We investigated the feasibility of the FCRS for the measurement of dose distributions near the superficial region for proton plans with a varying separation between the target volume and the surface of 3 patients using a humanoid phantom. Results: The dose-response has good linearity. Dose-rate and energy dependence were found to be within 1%. Depth-dose distributions in non-modulated proton beams obtained with the FCRS was in good agreement with the depth-dose measurements from the ionization chamber. To evaluate the dosimetric accuracy of the FCRS, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the FCRS was within 3%. With in vivo dosimetry using the humanoid phantom, the calculated surface doses overestimated measurements by 4%–8% using FCRS. Conclusion: In previous study, our results indicate that the performance of the array-type FCRS was comparable to that of the currently used a multi-layer ion chamber system. In this study, we also believe that the fiber-optic Cerenkov radiation sensor has considerable potential for use with in vivo patient proton dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy

To develop a quality assurance (QA) of XVI cone beam system (XVIcbs) for its optimal imaging-guided radiotherapy (IGRT) implementation, and to construe prostate tumor margin required for intensity-modulated radiation therapy (IMRT) if IGRT is unavailable. XVIcbs spatial accuracy was explored with a humanoid phantom; isodose conformity to lesion target with a rice phantom housing a soap as target; image resolution with a diagnostic phantom; and exposure validation with a Radcal ion chamber. To optimize XVIcbs, rotation flexmap on coincidency between gantry rotational axis and that of XVI cone beam scan was investigated. Theoretic correlation to image quality of XVIcbs rotational axis stability was elaborately studied. Comprehensive QA of IGRT using XVIcbs has initially been explored and then implemented on our general IMRT treatments, and on special IMRT radiotherapies such as head and neck (H and N), stereotactic radiation therapy (SRT), stereotactic radiosurgery (SRS), and stereotactic body radiotherapy (SBRT). Fifteen examples of prostate setup accounted for 350 IGRT cone beam system were analyzed. IGRT accuracy results were in agreement {+-} 1 mm. Flexmap 0.25 mm met the manufacturer's specification. Films confirmed isodose coincidence with target (soap) via XVIcbs, otherwise not. Superficial doses were measured from 7.2-2.5 cGy for anatomic diameters 15-33 cm, respectively. Image quality was susceptible to rotational stability or patient movement. IGRT using XVIcbs on general IMRT treatments such as prostate, SRT, SRS, and SBRT for setup accuracy were verified; and subsequently coordinate shifts corrections were recorded. The 350 prostate IGRT coordinate shifts modeled to Gaussian distributions show central peaks deviated off the isocenter by 0.6 {+-} 3.0 mm, 0.5 {+-} 4.5 mm in the X(RL)- and Z(SI)-coordinates, respectively; and 2.0 {+-} 3.0 mm in the Y(AP)-coordinate as a result of belly and bladder capacity variations. Sixty-eight percent of confidence was within {+-} 4.5 mm coordinates shifting. IGRT using XVIcbs is critical to IMRT for prostate and H and N, especially SRT, SRS, and SBRT. To optimize this modality of IGRT, a vigilant QA program is indispensable. Prostate IGRT reveals treatment accuracy as subject to coordinates' adjustments; otherwise a 4.5-mm margin is required to allow for full dose coverage of the clinical target volume, notwithstanding toxicity to normal tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Case Study on Pathogen Transport, Deposition, Evaporation and Transmission: Linking High-Fidelity Computational Fluid Dynamics Simulations to Probability of Infection

A high-fidelity, low-Mach computational fluid dynamics simulation tool that includes evaporating droplets and variable-density turbulent flow coupling is well-suited to ascertain transmission probability and supports risk mitigation methods development for airborne infectious diseases such as COVID-19. A multi-physics large-eddy simulation-based paradigm is used to explore droplet and aerosol pathogen transport from a synthetic cough emanating from a kneeling humanoid. For an outdoor configuration that mimics the recent open-space social distance strategy of San Francisco, maximum primary droplet deposition distances are shown to approach 8.1 m in a moderate wind configuration with the aerosol plume transported in excess of 15 m. In quiescent conditions, the aerosol plume extends to approximately 4 m before the emanating pulsed jet becomes neutrally buoyant. A dose–response model, which is based on previous SARS coronavirus (SARS-CoV) data, is exercised on the high-fidelity aerosol transport database to establish relative risk at eighteen virtual receptor probe locations.

59 BASIC BIOLOGICAL SCIENCES↗

Reference dosimetry during diagnostic CT examination using XR-QA radiochromic film model

Purpose: The authors applied 2D reference dosimetry protocol for dose measurements using XR-QA radiochromic film model during diagnostic computed tomography (CT) examinations carried out on patients and humanoid Rando phantom. Methods: Response of XR-QA model GAFCHROMIC film reference dosimetry system was calibrated in terms of Air-Kerma in air. Four most commonly used CT protocols were selected on their CT scanner (GE Lightspeed VCT 64), covering three anatomical sites (head, chest, and abdomen). For each protocol, 25 patients ongoing planned diagnostic CT examination were recruited. Surface dose was measured using four or eight film strips taped on patients' skin and on Rando phantom. Film pieces were scanned prior to and after irradiation using Epson Expression 10000XL document scanner. Optical reflectance of the unexposed film piece was subtracted from exposed one to obtain final net reflectance change, which is subsequently converted to dose using previously established calibration curves. Results: The authors' measurements show that body skin dose variation has a sinusoidal pattern along the scanning axis due to the helical movement of the x-ray tube, and a comb pattern for head dose measurements due to its axial movement. Results show that the mean skin dose at anterior position for patients is (51 {+-} 6) mGy, (29 {+-} 11) mGy, (45 {+-} 13) mGy and (38 {+-} 20) mGy for head, abdomen, angio Abdomen, and chest and abdomen protocol (UP position), respectively. The obtained experimental dose length products (DLP) show higher values than CT based DLP taken from the scanner console for body protocols, but lower values for the head protocol. Internal dose measurements inside the phantom's head indicate nonuniformity of dose distribution within scanned volume. Conclusions: In this work, the authors applied an Air-Kerma in air based radiochromic film reference dosimetry protocol for in vivo skin dose measurements. In this work, they employed green channel extracted from the scanned RGB image for dose measurements in the range from 0 to 200 mGy. Measured skin doses and corresponding DLPs were higher than DLPs provided by the CT scanner manufacturer as they were measured on patients' skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques

Purpose: Dosimetric accuracy in radiation treatment of breast cancer is critical for the evaluation of cosmetic outcomes and survival. It is often considered that treatment planning systems (TPS) may not be able to provide accurate dosimetry in the buildup region. This was investigated in various treatment techniques such as tangential wedges, field-in-field (FF), electronic compensator (eComp), and intensity-modulated radiotherapy (IMRT). Methods: Under Institutional Review Board (IRB) exemption, radiotherapy treatment plans of 111 cases were retrospectively analyzed. The distance between skin surface and 95% isodose line was measured. For measurements, Gafchromic EBT2 films were used on a humanoid unsliced phantom. Multiple layers of variable thickness of superflab bolus were placed on the breast phantom and CT scanned for planning. Treatment plans were generated using four techniques with two different grid sizes (1 Multiplication-Sign 1 and 2.5 Multiplication-Sign 2.5 mm{sup 2}) to provide optimum dose distribution. Films were placed at different depths and exposed with the selected techniques. A calibration curve for dose versus pixel values was also generated on the same day as the phantom measurement was conducted. The DICOM RT image, dose, and plan data were imported to the in-house software. On axial plane of CT slices, curves were drawn at the position where EBT2 films were placed, and the dose profiles on the lines were acquired. The calculated and measured dose profiles were separated by check points which were marked on the films before irradiation. The segments of calculated profiles were stretched to match their resolutions to that of film dosimetry. Results: On review of treatment plans, the distance between skin and 95% prescribed dose was up to 8 mm for plans of 27 patients. The film measurement revealed that the medial region of phantom surface received a mere 45%-50% of prescribed dose. For wedges, FF, and eComp techniques, region around the nipple received approximately 80% of prescribed dose, although only IMRT showed inhomogeneous dose profile. At deeper depths mainly (6-11 mm depths), film dosimetry showed good agreement with the TPS calculation. In contrast, the measured dose at a 3-mm depth was higher than TPS calculation by 15%-30% for all techniques. For the tangential and IMRT techniques, 1 Multiplication-Sign 1 mm{sup 2} grid size showed a smaller difference than that with a 2.5 Multiplication-Sign 2.5 mm{sup 2} grid size compared to the measurements. Conclusions: In general, TPS even with advanced algorithms do not provide accurate dosimetry in the buildup region, as verified by EBT2 film for all treatment techniques. For all cases, TPS and measured doses were in agreement from 6 mm in depth but differed at shallower depths. Grid size plays an important role in dose calculation. For accurate dosimetry small grid size should be used where differences are lower between TPS and measurements.

60 APPLIED LIFE SCIENCES↗

Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty

Purpose: Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis.Methods: Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients.Results: For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4–146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10{sup −5} to 837.4 × 10{sup −5} depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2–541.0) × 10{sup −5}. The probability of bladder cancer development was more than 113.7 × 10{sup −5} and 110.3 × 10{sup −5} for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003–68.5) × 10{sup −5}.Conclusions: The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ site in respect to treatment volume and patient's gender and age. The presented risk estimates may be useful in the follow-up studies of irradiated patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-58: Dosimetric Verification of Metal Artifact Effects: Comparison of Dose Distributions Affected by Patient Teeth and Implants

Purpose: Implant-supported dentures seem particularly appropriate for the predicament of becoming edentulous and cancer patients are no exceptions. As the number of people having dental implants increased in different ages, critical dosimetric verification of metal artifact effects are required for the more accurate head and neck radiation therapy. The purpose of this study is to verify the theoretical analysis of the metal(streak and dark) artifact, and to evaluate dosimetric effect which cause by dental implants in CT images of patients with the patient teeth and implants inserted humanoid phantom. Methods: The phantom comprises cylinder which is shaped to simulate the anatomical structures of a human head and neck. Through applying various clinical cases, made phantom which is closely allied to human. Developed phantom can verify two classes: (i)closed mouth (ii)opened mouth. RapidArc plans of 4 cases were created in the Eclipse planning system. Total dose of 2000 cGy in 10 fractions is prescribed to the whole planning target volume (PTV) using 6MV photon beams. Acuros XB (AXB) advanced dose calculation algorithm, Analytical Anisotropic Algorithm (AAA) and progressive resolution optimizer were used in dose optimization and calculation. Results: In closed and opened mouth phantom, because dark artifacts formed extensively around the metal implants, dose variation was relatively higher than that of streak artifacts. As the PTV was delineated on the dark regions or large streak artifact regions, maximum 7.8% dose error and average 3.2% difference was observed. The averaged minimum dose to the PTV predicted by AAA was about 5.6% higher and OARs doses are also 5.2% higher compared to AXB. Conclusion: The results of this study showed that AXB dose calculation involving high-density materials is more accurate than AAA calculation, and AXB was superior to AAA in dose predictions beyond dark artifact/air cavity portion when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-208: Incidence Cancer Risk From the Radiation Treatment for Acoustic Neuroma Patient

Purpose: The present study aimed to compare the incidence risk of a secondary cancer from therapeutic doses in patients receiving intensitymodulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). Methods: Four acoustic neuroma patients were treated with IMRT, VMAT, or SRS. Their incidnece excess relative risk (ERR), excess absolute risk (EAR), and lifetime attributable risk (LAR) were estimated using the corresponding therapeutic doses measured at various organs by radio-photoluminescence glass dosimeters (RPLGD) placed inside a humanoid phantom. Results: When a prescription dose was delivered in the planning target volume of the 4 patients, the average organ equivalent doses (OED) at the thyroid, lung, normal liver, colon, bladder, prostate (or ovary), and rectum were measured. The OED decreased as the distance from the primary beam increased. The thyroid received the highest OED compared to other organs. A LAR were estimated that more than 0.03% of AN patients would get radiation-induced cancer. Conclusion: The tyroid was highest radiation-induced cancer risk after radiation treatment for AN. We found that LAR can be increased by the transmitted dose from the primary beam. No modality-specific difference in radiation-induced cancer risk was observed in our study.

60 APPLIED LIFE SCIENCES↗

Breast dosimetry in transverse and longitudinal field MRI-Linac radiotherapy systems

Purpose: In the framework of developing the integration of a MRI-Linac system, configurations of MRI-Linac units were simulated in order to improve the dose distribution in tangential breast radiotherapy using transverse and longitudinal magnetic field geometries of Lorentz force for both medial and lateral tangential fields. Methods: In this work, the GEANT4 Monte Carlo (MC) code was utilized to compare dose distributions in breast radiotherapy for Linac-MR systems in the transverse and longitudinal geometries within humanoid phantoms across a range of magnetic field strengths of 0.5 and 1.5 T. The dose increment due to scattering from the coils was investigated for both geometries as well. Computed tomography images of two patients were used for MC simulations. One patient had intact breast while the other was mastectomized. In the simulations, planning and methods of chest wall irradiation were similar to the actual clinical planning. Results: In a longitudinal geometry, the magnetic field is shown to restrict the lateral spread of secondary electrons to the lung, heart, and contralateral organs, which reduced the mean dose of the ipsilateral lung and heart by means of 17.2% and 6% at 1.5 T, respectively. The transverse configuration exhibits a significant increase in tissue interface effects, which increased dose buildup in the entrance regions of the lateral and medial tangent beams to the planning target volume (PTV) and improved dose homogeneity within the PTV. The improved relative average homogeneity index for two patients to the PTV at magnetic field strength of 1.5 T with respect to no magnetic field case evaluated was 11.79% and 34.45% in the LRBP and TRBP geometries, respectively. In both geometries, the simulations show significant mean dose reductions in the contralateral breast and chest wall skin, respectively, by a mean of 16.6% and 24.9% at 0.5 T and 17.2% and 28.1% at 1.5 T in the transverse geometry, and 10.56% and 14.6% at 0.5 T and 11.3% and 16.3% at 1.5 T in the longitudinal geometry. Considering the scattered photons which reflected from the coils, the average relative dose of each voxel is slightly increased by 0.53% and 0.32% in the LRBP and TRBP geometries, respectively. Conclusions: Orienting the B0 magnetic field parallel to the photon beam axis, LRBP geometry, tends to restrict the radial spread of secondary electrons which resulted in dose reduction to the lung. Dosimetry issues observed in both Linac-MR geometries, such as changes to the lateral dose distribution, significantly exhibited dose reduction in the contralateral organs on a representative breast plan. Further, the results show sharper edge dose volume histogram curves at 1.5 T for both geometries, especially in the LRBP configuration.

60 APPLIED LIFE SCIENCES↗