Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydraulic Power Supplies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing IMAC-XL

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Evaluation of all-electric secondary power for transport aircraft

This report covers a study by Douglas Aircraft Company (DAC) of electrical power systems for advanced transport aircraft based upon an all-electric design concept. The concept would eliminate distributed hydraulic and pneumatic secondary power systems, and feature an expanded secondary electrical power system redesigned to supply power to the loads customarily supplied by hydraulic or pneumatic power. The initial study was based on an advanced 20-kHz electrical power transmission and distribution system, using a system architecture supplied by NASA-Lewis Research Center for twin-engine aircraft with many advanced power conversion concepts. NASA-LeRC later requested DAC to refocus the study on 400-Hz secondary power distribution. Subsequent work was based on a three-engine MD-11 aircraft, selected by DAC as a baseline system design that would provide data for the comparative cost/benefit analysis. The study concluded that the 20-kHz concept produced many expected benefits, and that the all-electric trijet weight savings on hardware redesign would be 2,304 pounds plus a 2.1-percent fuel reduction and resized for a total weight reduction of 11,000 pounds. Cost reductions for a fleet of 800 aircraft in a 15-year production program were estimated at $76.71 million for RDT&E; $2.74 million per aircrat for production; $9.84 million for nonrecurring expenses; $120,000 per aircraft for product support; and $300,000 per aircraft per year for operating and maintenance costs, giving a present value of $1.914 billion saved or a future value of $10.496 billion saved.

Murray, W. E.↗

The application of hydraulics in the 2,000 kW wind turbine generator

A 2000 kW turbine generator using hydraulic power in two of its control systems is being built under the management of NASA Lewis Research Center. The hydraulic systems providing the control torques and forces for the yaw and blade pitch control systems are discussed. The yaw-drive-system hydraulic supply provides the power for positioning the nacelle so that the rotary axis is kept in line with the direction of the prevailing wind, as well as pressure to the yaw and high speed shaft brakes. The pitch-change-mechanism hydraulic system provides the actuation to the pitch change mechanism and permits feathering of the blades during an emergency situation. It operates in conjunction with the overall windmill computer system, with the feather control permitting slewing control flow to pass from the servo valve to the actuators without restriction.

Onufreiczuk, S.↗

Space Shuttle Orbiter auxiliary power unit status

An overview of the United States Space Shuttle Orbiter APU, which provides power to the Orbiter vehicle hydraulic system, is presented. Three complete APU systems, each with its own separate fuel system, supply power to three dedicated hydraulic systems. These in turn provide power to all Orbiter vehicle critical flight functions including launch, orbit, reentry, and landing. The basic APU logic diagram is presented. The APU includes a hydrazine-powered turbine that drives a hydraulic pump and various accessories through a high-speed gearbox. The APU also features a sophisticated thermal management system designed to ensure safe and reliable operation in the various launch, orbit, reentry, and landing environments.

Reck, M.↗

Free-piston regenerative hot gas hydraulic engine

A displacer piston which is driven pneumatically by a high-pressure or low-pressure gas is included in a free-piston regenerative hydraulic engine. Actuation of the displacer piston circulates the working fluid through a heater, a regenerator and a cooler. The present invention includes an inertial mass such as a piston or a hydraulic fluid column to effectively store and supply energy during portions of the cycle. Power is transmitted from the working fluid to a hydraulic fluid across a diaphragm or lightweight piston to achieve a hydraulic power out-put. The displacer piston of the present invention may be driven pneumatically, hydraulically or electromagnetically. In addition, the displacer piston and the inertial mass of the present invention may be positioned on the same side of the diaphragm member or may be separated by the diaphragm member.

Beremand, D. G.↗

Design and test of a high power electromechanical actuator for thrust vector control

NASA-Marshall is involved in the development of electromechanical actuators (EMA) for thrust-vector control (TVC) system testing and implementation in spacecraft control/gimballing systems, with a view to the replacement of hydraulic hardware. TVC system control is furnished by solid state controllers and power supplies; a pair of resolvers supply position feedback to the controller for precise positioning. Performance comparisons between EMA and hydraulic TVC systems are performed.

Cowan, J. R.↗

Space Shuttle Upgrades Advanced Hydraulic Power System

Three Auxiliary Power Units (APU) on the Space Shuttle Orbiter each provide 145 hp shaft power to a hydraulic pump which outputs 3000 psi hydraulic fluid to 41 hydraulic actuators. A hydrazine fuel powered APU utilized throughout the Shuttle program has undergone many improvements, but concerns remain with flight safety, operational cost, critical failure modes, and hydrazine related hazards. The advanced hydraulic power system (AHPS), also known as the electric APU, is being evaluated as an upgrade to replace the hydrazine APU. The AHPS replaces the high-speed turbine and hydrazine fuel supply system with a battery power supply and electric motor/pump that converts 300 volt electrical power to 3000 psi hydraulic power. AHPS upgrade benefits include elimination of toxic hydrazine propellant to improve flight safety, reduction in hazardous ground processing operations, and improved reliability. Development of this upgrade provides many interesting challenges and includes development of four hardware elements that comprise the AHPS system: Battery - The battery provides a high voltage supply of power using lithium ion cells. This is a large battery that must provide 28 kilowatt hours of energy over 99 minutes of operation at 300 volts with a peak power of 130 kilowatts for three seconds. High Voltage Power Distribution and Control (PD&C) - The PD&C distributes electric power from the battery to the EHDU. This 300 volt system includes wiring and components necessary to distribute power and provide fault current protection. Electro-Hydraulic Drive Unit (EHDU) - The EHDU converts electric input power to hydraulic output power. The EHDU must provide over 90 kilowatts of stable, output hydraulic power at 3000 psi with high efficiency and rapid response time. Cooling System - The cooling system provides thermal control of the Orbiter hydraulic fluid and EHDU electronic components. Symposium presentation will provide an overview of the AHPS upgrade, descriptions of the four hardware elements, and a summary of development results to date.

Source record↗

Reduced-gravity two-phase flow experiments in the NASA KC-135

An adequate understanding is sought of flow and heat transfer behavior in reduced and zero gravity conditions. Microgravity thermal-hydraulic analysis capabilities were developed for application to space nuclear power systems. A series of reduced gravity two phase flow experiments using the NASA KC-135 were performed. The objective was to supply basic thermal hydraulic information that could be used in development of analytical tools for design of space power systems. The experiments are described. Two main conclusions were drawn. First, the tests demonstrate that the KC-135 is a suitable test environment for obtaining two phase flow and heat transfer data in reduced gravity conditions. Second, the behavior of two phase flow in low gravity is sufficiently different from that obtained in 1 g to warrant intensive investigation of the phenomenon if adequate analytical tools are to be developed for microgravity conditions.

Cuta, Judith M.↗

Design, fabrication and testing of two electrohydraulic vibration isolation systems for helicopter environments

Two electrohydraulic vibration isolation systems were designed and fabricated to reduce the vertical vibrations transmitted to the XH-51N research helicopter cabin at the blade passage frequency (18 Hz) and its first harmonic (36 Hz). Hydraulic power and electrical control are provided to two separate servoactuators from a common power supply and control electronics package located behind the pilot's seat. One servoactuator is installed between the cabin and fuselage and replaces an existing passive spring. A second servoactuator is mounted between the existing seat and cabin floor. Both servoactuators incorporate a mechanical failsafe design. The control electronics circuitry provides automatic tracking of the blade passage frequency. Results of laboratory, environmental and ground vibration tests employing an XH-51A stripped down helicopter fuselage show that the active cabin isolator reduces the vertical vibrations transmitted from the fuselage attachment point to the cabin attachment point at 18 and 36 Hz (or as an alternative, 6 Hz) by better than 90 percent.

Allen, R. E.↗

Automatic compression adjusting mechanism for internal combustion engines

Means for controlling the compression pressure in an internal combustion engine having one or more cylinders and subject to widely varying power output requirements are provided. Received between each crank pin and connecting rod is an eccentric sleeve selectively capable of rotation about the crank pin and/or inside the rod and for latching with the rod to vary the effective length of the connecting rod and thereby the clearance volume of the engine. The eccentric normally rotates inside the connecting rod during the exhaust and intake strokes but a latching pawl carried by the eccentric is movable radially outwardly to latch the rod and eccentric together during the compression and power strokes. A control valve responds to intake manifold pressure to time the supply of hydraulic fluid to move the latch-pawl outwardly, varying the effective rod length to maintain a substantially optimum firing chamber pressure at all intake manifold pressures.

Akkerman, J. W.↗

Space Transportation System solid rocket booster thrust vector control system

The Solid Rocket Booster, Thrust Vector Control (TVC) system was designed in accordance with the following requirements: self-contained power supply, failsafe operation, 20 flight uses after exposure to seawater landings, optimized cost, and component interchangeability. Trade studies were performed which led to the selection of a recirculating hydraulic system powered by Auxiliary Power Units (APU) which drive the hydraulic actuators and gimbal the solid rocket motor nozzle. Other approaches for the system design were studied in arriving at the recirculating hydraulic system powered by an APU. These systems must withstand the imposed environment and be usable for a minimum of 20 Space Transportation System flights with a minimum of refurbishment. The TVC system completed the required qualification and verification tests and is certified for the intended application. Substantiation data include analytical and test data.

Verble, A. J., Jr.↗

Space transportation system solid rocket booster thrust vector control system

The Solid Rocket Booster, Thrust Vector Control (TVC) system was designed in accordance with the following requirements: self-contained power supply, fail-safe operation, 20 flight uses after exposure to seawater landings, optimized cost, and component interchangeability. Trade studies were performed which led to the selection of a recirculating hydraulic system powered by Auxiliary Power Units (APU) which drive the hydraulic actuators and gimbal the solid rocket motor nozzle. Other approaches for the system design were studied in arriving at the recirculating hydraulic system powered by an APU. These systems must withstand the imposed environment and be usable for a minimum of 20 Space Transportation System flights with a minimum of refurbishment. The TVC system has completed the major portion of qualification and verification tests and is prepared to be cleared for the first Shuttle flight (STS-1). Substantiation data will include analytical and test data.

Verble, A. J., Jr.↗

A Cooling System for the EAPU Shuttle Upgrade

The Shuttle orbiter currently uses hydrazine-powered APU's for powering its hydraulic system pumps. To enhance vehicle safety and reliability, NASA is pursuing an APU upgrade where the hydrazine powered turbine is replaced by an electric motor pump and battery power supply. This EAPU (Electric APU) upgrade presents several thermal control challenges most notably the new requirement for moderate temperature control of high-power electron ics at 132 of (55.6 C). This paper describes how the existing Water Spray Boiler (WSB), which currently cools the hydraulic fluid and APU lubrication oil, is being modified to provide EAPU thermal management.

Tongue, Stephen↗

Compound hydraulic shear-modulated vortex amplifiers

A novel two-stage shear-modulated hydraulic vortex amplifier (U.S. patent 3,520,317) has been fabricated and put through preliminary steady-state testing at the 1000 psi supply pressure level with flows up to 15 gpm. The invention comprises a conventional fluidic vortex power stage and a shear-modulated pilot stage. In the absence of any mechanical moving parts, water may be used as the hydraulic medium thus opening the way to many underseas applications. At blocked load, a control input from 0 to 150 psi was required to achieve an output from 0 to 900 psi; at wide-open load, a control input of 0 to 120 psi was needed to achieve an output from 0 to 15 gpm. The power stage has been found unsuitable for the proportional control mode because of its nonlinear performance in the intermediate load range and because of strong pressure fluctuations (plus or minus 150 psi) in the intermediate control range. The addition of the shear-modulated pilot stage improves intermediate load linearity.

Goldschmied, F. R.↗

Preliminary design of an auxiliary power unit for the space shuttle: Component and system configuration screening analysis

The auxiliary power unit (APU) for the space shuttle is required to provide hydraulic and electrical power on board the booster and orbiter vehicles. Five systems and their associated components, which utilize hot gas turbines to supply horsepower at gearbox output pads, were studied. Hydrogen-oxygen and storable propellants were considered for the hot gas supply. All APU's were required to be self-contained with respect to dissipating internally generated heat. These five systems were evaluated relative to a consistent criteria. The system supplied with high pressure gaseous hydrogen and oxygen was recommended as the best approach. It included a two-stage pressure-compounded partial-admission turbine, a propellant conditioning system with recuperation, a control system, and a gearbox. The gearbox output used was 240 hp. At the close of the study a 400 hp level was considered more appropriate for meeting the prime shuttle vehicle needs, and an in-depth analysis of the system at the 400 hp output level was recommended.

Binsley, R. L.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 2: Component and system configuration screening analysis

The auxiliary power unit (APU) for the space shuttle is required to provide hydraulic and electrical power on board the booster and orbiter vehicles. Five systems and their associated components, which utilize hot gas turbines to supply horsepower at gearbox output pads, were studied. Hydrogen-oxygen and storable propellants were considered for the hot gas supply. All APU's were required to be self contained with respect to dissipating internally generated heat. These five systems were evaluated relative to a consistent criteria. The system supplied with high pressure gaseous hydrogen and oxygen was recommended as the best approach. It included a two-stage pressure-compounded partial-admission turbine, a propellant conditioning system with recuperation, a control system, and a gearbox. The gearbox output used was 240 HP. At the close of the study a 400 HP level was considered more appropriate for meeting the prime shuttle vehicle needs, and an in-depth analysis of the system at the 400 HP output level was recommended.

Burriss, W. L.↗