Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrogen Concentrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Control of hydrogen concentrations by microbial sulfate reduction in two contrasting anoxic coastal sediments

Introduction Molecular hydrogen is produced by the fermentation of organic matter and consumed by organisms including hydrogenotrophic methanogens and sulfate reducers in anoxic marine sediment. The thermodynamic feasibility of these metabolisms depends strongly on organic matter reactivity and hydrogen concentrations; low organic matter reactivity and high hydrogen concentrations can inhibit fermentation so when organic matter is poor, fermenters might form syntrophies with methanogens and/or sulfate reducers who alleviate thermodynamic stress by keeping hydrogen concentrations low and tightly controlled. However, it is unclear how these metabolisms effect porewater hydrogen concentrations in natural marine sediments of different organic matter reactivities. Methods We measured aqueous concentrations of hydrogen, sulfate, methane, dissolved inorganic carbon, and sulfide with high-depth-resolution and 16S rRNA gene assays in sediment cores with low carbon reactivity in White Oak River (WOR) estuary, North Carolina, and those with high carbon reactivity in Cape Lookout Bight (CLB), North Carolina. We calculated the Gibbs energies of sulfate reduction and hydrogenotrophic methanogenesis. Results Hydrogen concentrations were significantly higher in the sulfate reduction zone at CLB than WOR (mean: 0.716 vs. 0.437 nM H 2 ) with highly contrasting hydrogen profiles. At WOR, hydrogen was extremely low and invariant (range: 0.41–0.52 nM H 2 ) in the upper 15 cm. Deeper than 15 cm, hydrogen became more variable (range: 0.312–2.56 nM H 2 ) and increased until methane production began at ~30 cm. At CLB, hydrogen was highly variable in the upper 15 cm (range: 0.08–2.18 nM H 2 ). Ratios of inorganic carbon production to sulfate consumption show AOM drives sulfate reduction in WOR while degradation of organics drive sulfate reduction in CLB. Discussion We conclude more reactive organic matter increases hydrogen concentrations and their variability in anoxic marine sediments. In our AOM-dominated site, WOR, sulfate reducers have tight control on hydrogen via consortia with fermenters which leads to the lower observed variance due to interspecies hydrogen transfer. After sulfate depletion, hydrogen accumulates and becomes variable, supporting methanogenesis. This suggests that CLB’s more reactive organic matter allows fermentation to occur without tight metabolic coupling of fermenters to sulfate reducers, resulting in high and variable porewater hydrogen concentrations that prevent AOM from occurring through reverse hydrogenotrophic methanogenesis.

Microbiology↗

Changes in Hydrogen Concentration and Defect State Density at the Poly-Si/SiOx/c-Si Interface Due to Firing

We determined the density of defect states of poly-Si/SiOx/c-Si junctions featuring a wet chemical interfacial oxide from lifetime measurements using the MarcoPOLO model to calculate recombination and contact resistance in poly-Si/SiOx/c-Si-junctions. In samples that did not receive any hydrogen treatment, the Dit,cSi is about 2 × 1012 cm-2 eV1 before firing and rises to 3–7 × 1012 cm2 eV1 during firing at measured peak temperatures between 620 °C and 863 °C. To address the question of why AlOx/SiNy stacks in contrast to pure SiNy layers for hydrogenation during firing provides better passivation quality, we have measured the hydrogen concentrations at the poly-Si/SiOx/c-Si interface as a function of AlOx layer thickness and compared these to J0 and calculated Dit,c-Si values. We observe an increase of the hydrogen concentration at the SiOx/c-Si interface upon firing as a function of the firing temperature that exceeds the defect concentrations at the interface several times. However, the AlOx layer thickness appears to cause an increase in hydrogen concentration at the SiOx/c-Si interface in these samples rather than exhibiting a hydrogen blocking property.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The use of the ion probe mass spectrometer in the measurement of hydrogen concentration gradients in Monel K 500

The ion probe mass spectrometer was used to measure hydrogen concentration gradients in cathodically charged Monel K 500. Initial work with the ion probe involved the calibration of the instrument and the establishment of a suitable experimental procedure for this application. Samples of Monel K 500 were cathodically charged in a weak sulfuric acid solution. By varying the current density, different levels of hydrogen were introduced into the samples. Hydrogen concentration gradients were taken by ion sputtering on the surface of these samples and monitoring the behavior of the hydrogen mass peak as a function of time. An attempt was made to determine the relative amounts of hydrogen in the bulk and grain boundaries by analyzing a fresh fracture surface with a higher proportion of grain boundary area. It was found that substantially more hydrogen was detected in the grain boundaries than in the bulk, confirming the predictions of previous workers. A sputter rate determination was made in order to establish the rate of erosion.

Truhan, J. J., Jr.↗

Measuring Hydrogen Concentrations in Metals

Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.

Danford, M. D.↗

Scatter Removal using Black Body Grids and Determining the Minimum Resolvable Hydrogen Concentration at MARS

This dataset was used to develop and validate a scatter-correction pipeline for neutron radiographs acquired at the MARS beamline, based on the methodology of Carminati et al. (2019). Scatter removal was performed using 36 gadolinium black bodies to characterize and remove the spatially varying neutron scatter field that cannot be eliminated by conventional open-beam normalization. The dataset comprises eight samples - four single-crystal nickel and four polycrystalline austenitic 316L stainless steel. Within each material system, samples were pre-charged with hydrogen gas at four charging pressures (1.5, 5, 12.5, and 20 kpsi). Following scatter correction, the pipeline was applied to all radiographs to recover quantitative attenuation maps. After subtracting the known attenuation contribution of the metal matrix, spatial maps of the hydrogen attenuation coefficient were obtained for each sample. This data was then used to construct a calibration curve relating hydrogen attenuation to hydrogen concentration and to determine the minimum resolvable hydrogen concentration at the MARS beamline. The resulting dataset provides a pressure-resolved calibration standard for quantitative hydrogen mapping using neutron radiography.

36 MATERIALS SCIENCE↗

Bulk Insolation Models as Predictors for Locations for High Lunar Hydrogen Concentrations

In this study we consider the bulk effects of surface illumination on topography (insolation) and the possible thermodynamic effects on the Moon's hydrogen budget. Insolation is important as one of the dominant loss processes governing distributions of hydrogen volatiles on the Earth, Mars and most recently Mercury. We evaluated three types of high latitude > 65 deg., illumination models that were derived from the Lunar Observing Laser Altimetry (LOLA) digital elevation models (DEM)'s. These models reflect varying accounts of solar flux interactions with the Moon's near-surface. We correlate these models with orbital collimated epithermal neutron measurements made by the Lunar Exploration Neutron Detector (LEND). LEND's measurements derive the Moon's spatial distributions of hydrogen concentration. To perform this analysis we transformed the topographic model into an insolation model described by two variables as each pixels 1) slope and 2) slope angular orientation with respect to the pole. We then decomposed the illumination models and epithermal maps as a function of the insolation model and correlate the datasets.

Hydrogen Concentrations↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

Evaluation of Heat Recuperation in a Concentric Hydrogen Reduction Reactor

Heat recuperation in an ISRU reactor system involves the recovery of heat from a reacted regolith batch by transferring this energy into a batch of fresh regolith. One concept for a hydrogen reduction reactor is a concentric chamber design where heat is transferred from the inner, reaction chamber into fresh regolith in the outer, recuperation chamber. This concept was tested and analyzed to define the overall benefit compared to a more traditional single chamber batch reactor. Data was gathered for heat-up and recuperation in the inner chamber alone, simulating a single chamber design, as well as recuperation into the outer chamber, simulating a dual chamber design. Experimental data was also used to improve two analytical models, with good agreement for temperature behavior during recuperation, calculated mass of the reactor concepts, and energy required during heat-up. The five tests, performed using JSC-1A regolith simulant, also explored the effectiveness of helium gas fluidization, hydrogen gas fluidization, and vibrational fluidization. Results indicate that higher hydrogen volumetric flow rates are required compared to helium for complete fluidization and mixing, and that vibrational fluidization may provide equivalent mixing while eliminating the need to flow large amounts of excess hydrogen. Analysis of the total energy required for heat-up and steady-state operations for a variety of conditions and assumptions shows that the dual-chamber concept requires the same or more energy than the single chamber concept. With no clear energy savings, the added mass and complexity of the dual-chamber makes it unlikely that this design concept will provide any added benefit to the overall ISRU oxygen production system.

Linne, Diane↗

How Low Can You Go? Maximum Constraints on Hydrogen Concentrations Prior to the Great Oxidation Event

Shaw postulates that Earth's early atmosphere was rich in reducing gases such as hydrogen, brought to Earth via impact events. This commentary seeks to place constraints on this idea through a very brief review of existing geological and geochemical upper limits on the reducing power of Earth's atmosphere prior to the rise of oxygen. While these constraints place tight limits on this idea for rocks younger than 3.8 Ga, few constraints exist prior to that time, due to a paucity of rocks of that age. The time prior to these constraints is also a time frame for which the proposal is most plausible, and for which it carries the greatest potential to explain other mysteries. Given this potential, several tests are suggested for the H2-rich early Earth hypothesis.

Earth's early atmosphere↗

Resolution of the discrepancy between Balmer alpha emission rates, the solar Lyman beta flux, and models of geocoronal hydrogen concentration

New satellite Balmer alpha measurements and solar Lyman beta flux and line profile measurements, together with new measurements of the zodiacal light intensity used in correcting both ground and satellite Balmer alpha measurements for the effects of the Fraunhofer line in the zodiacal light, have been used in a reevaluation of the long-standing discrepancy between ground-based Balmer alpha emission rates and other geocoronal hydrogen parameters. The solar Lyman beta line center flux is found to be (4.1 plus or minus 1.3) billion photons per sq cm per sec per angstrom at S(10.7) equals 110 and, together with a current hydrogen model which has 92,000 atoms per cu cm at 650 km for T(inf) equals 950 K, gives good agreement between calculated Balmer alpha emission rates and the ground-based and satellite measurements.

Levasseur, A.-C.↗

Hydrogen Concentrations on C-Class Asteroids Derived from Remote Sensing

We present spectroscopic observations of 16 asteroids from 1.9-3.6 microns collected from the United Kingdom Infrared Telescope (UKIRT) from 1996-2000. Of these 16 asteroids, 11 show some evidence of a 3 microns hydrated mineral absorption feature greater than 2(sigma) at 2.9 microns. Using relations first recognized for carbonaceous chondrite powders by Miyamoto and Zolensky and Sato et al., we have determined the hydrogen to silicon ratio for these asteroids and calculated their equivalent water contents, assuming all the hydrogen was in water. The asteroids split into 2 groups, roughly defined as equivalent water contents approx. greater than 7% (8 asteroids, all with 3 microns band depths approx. greater than 20%) and approx. greater than 3% for the remaining 8 asteroids. This latter group includes some asteroids for which a weak but statistically significant 3 microns band of non-zero depth exists. The G-class asteroids in the survey have higher water contents, consistent with CM chondrites. This strengthens the connection between CM chondrites and G asteroids that was proposed by Burbine. We find that the 0.7 microns and 3 microns band depths are correlated for the population of target objects.

Rivkin, A. S.↗

Hydrogen Concentrations on C-class Asteroids Derived from Remote Sensing

We present spectroscopic observations of 16 asteroids from 1.9-3.6 microns collected from the United Kingdom Infrared Telescope (UKIRT) from 1996-2000. Of these 16 asteroids, 11 show some evidence of a 3 micron hydrated mineral absorption feature greater than 2 sigma at 2.9 microns. Using relations first recognized for carbonaceous chondrite powders by Miyamoto and Zolensky (1994) and Sato et al. (1997), we have determined the hydrogen to silicon ratio for these asteroids and calculated their equivalent water contents, assuming all the hydrogen was in water. The asteroids split into 2 groups, roughly defined as equivalent water contents greater than approximately 7% (8 asteroids, all with 3 micron band depths greater than approximately 20%) and less than approximately 3% for the remaining 8 asteroids. This latter group includes some asteroids for which a weak but statistically significant 3 micron band of non-zero depth exists. The G-class asteroids in the survey have higher water contents, consistent with CM chondrites. This strengthens the connection between CM chondrites and G asteroids that was proposed by Burbine (1998). We find that the 0.7 micron and 3 micron band depths are correlated for the population of target objects.

Rivkin, A. S.↗