The use of the ion probe mass spectrometer in the measurement of hydrogen concentration gradients in Monel K 500

The ion probe mass spectrometer was used to measure hydrogen concentration gradients in cathodically charged Monel K 500. Initial work with the ion probe involved the calibration of the instrument and the establishment of a suitable experimental procedure for this application. Samples of Monel K 500 were cathodically charged in a weak sulfuric acid solution. By varying the current density, different levels of hydrogen were introduced into the samples. Hydrogen concentration gradients were taken by ion sputtering on the surface of these samples and monitoring the behavior of the hydrogen mass peak as a function of time. An attempt was made to determine the relative amounts of hydrogen in the bulk and grain boundaries by analyzing a fresh fracture surface with a higher proportion of grain boundary area. It was found that substantially more hydrogen was detected in the grain boundaries than in the bulk, confirming the predictions of previous workers. A sputter rate determination was made in order to establish the rate of erosion.

Truhan, J. J., Jr.↗

Measuring Hydrogen Concentrations in Metals

Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.

Danford, M. D.↗

Bulk Insolation Models as Predictors for Locations for High Lunar Hydrogen Concentrations

In this study we consider the bulk effects of surface illumination on topography (insolation) and the possible thermodynamic effects on the Moon's hydrogen budget. Insolation is important as one of the dominant loss processes governing distributions of hydrogen volatiles on the Earth, Mars and most recently Mercury. We evaluated three types of high latitude > 65 deg., illumination models that were derived from the Lunar Observing Laser Altimetry (LOLA) digital elevation models (DEM)'s. These models reflect varying accounts of solar flux interactions with the Moon's near-surface. We correlate these models with orbital collimated epithermal neutron measurements made by the Lunar Exploration Neutron Detector (LEND). LEND's measurements derive the Moon's spatial distributions of hydrogen concentration. To perform this analysis we transformed the topographic model into an insolation model described by two variables as each pixels 1) slope and 2) slope angular orientation with respect to the pole. We then decomposed the illumination models and epithermal maps as a function of the insolation model and correlate the datasets.

Hydrogen Concentrations↗

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

Evaluation of Heat Recuperation in a Concentric Hydrogen Reduction Reactor

Heat recuperation in an ISRU reactor system involves the recovery of heat from a reacted regolith batch by transferring this energy into a batch of fresh regolith. One concept for a hydrogen reduction reactor is a concentric chamber design where heat is transferred from the inner, reaction chamber into fresh regolith in the outer, recuperation chamber. This concept was tested and analyzed to define the overall benefit compared to a more traditional single chamber batch reactor. Data was gathered for heat-up and recuperation in the inner chamber alone, simulating a single chamber design, as well as recuperation into the outer chamber, simulating a dual chamber design. Experimental data was also used to improve two analytical models, with good agreement for temperature behavior during recuperation, calculated mass of the reactor concepts, and energy required during heat-up. The five tests, performed using JSC-1A regolith simulant, also explored the effectiveness of helium gas fluidization, hydrogen gas fluidization, and vibrational fluidization. Results indicate that higher hydrogen volumetric flow rates are required compared to helium for complete fluidization and mixing, and that vibrational fluidization may provide equivalent mixing while eliminating the need to flow large amounts of excess hydrogen. Analysis of the total energy required for heat-up and steady-state operations for a variety of conditions and assumptions shows that the dual-chamber concept requires the same or more energy than the single chamber concept. With no clear energy savings, the added mass and complexity of the dual-chamber makes it unlikely that this design concept will provide any added benefit to the overall ISRU oxygen production system.

Linne, Diane↗

How Low Can You Go? Maximum Constraints on Hydrogen Concentrations Prior to the Great Oxidation Event

Shaw postulates that Earth's early atmosphere was rich in reducing gases such as hydrogen, brought to Earth via impact events. This commentary seeks to place constraints on this idea through a very brief review of existing geological and geochemical upper limits on the reducing power of Earth's atmosphere prior to the rise of oxygen. While these constraints place tight limits on this idea for rocks younger than 3.8 Ga, few constraints exist prior to that time, due to a paucity of rocks of that age. The time prior to these constraints is also a time frame for which the proposal is most plausible, and for which it carries the greatest potential to explain other mysteries. Given this potential, several tests are suggested for the H2-rich early Earth hypothesis.

Earth's early atmosphere↗

Resolution of the discrepancy between Balmer alpha emission rates, the solar Lyman beta flux, and models of geocoronal hydrogen concentration

New satellite Balmer alpha measurements and solar Lyman beta flux and line profile measurements, together with new measurements of the zodiacal light intensity used in correcting both ground and satellite Balmer alpha measurements for the effects of the Fraunhofer line in the zodiacal light, have been used in a reevaluation of the long-standing discrepancy between ground-based Balmer alpha emission rates and other geocoronal hydrogen parameters. The solar Lyman beta line center flux is found to be (4.1 plus or minus 1.3) billion photons per sq cm per sec per angstrom at S(10.7) equals 110 and, together with a current hydrogen model which has 92,000 atoms per cu cm at 650 km for T(inf) equals 950 K, gives good agreement between calculated Balmer alpha emission rates and the ground-based and satellite measurements.

Levasseur, A.-C.↗

Hydrogen Concentrations on C-Class Asteroids Derived from Remote Sensing

We present spectroscopic observations of 16 asteroids from 1.9-3.6 microns collected from the United Kingdom Infrared Telescope (UKIRT) from 1996-2000. Of these 16 asteroids, 11 show some evidence of a 3 microns hydrated mineral absorption feature greater than 2(sigma) at 2.9 microns. Using relations first recognized for carbonaceous chondrite powders by Miyamoto and Zolensky and Sato et al., we have determined the hydrogen to silicon ratio for these asteroids and calculated their equivalent water contents, assuming all the hydrogen was in water. The asteroids split into 2 groups, roughly defined as equivalent water contents approx. greater than 7% (8 asteroids, all with 3 microns band depths approx. greater than 20%) and approx. greater than 3% for the remaining 8 asteroids. This latter group includes some asteroids for which a weak but statistically significant 3 microns band of non-zero depth exists. The G-class asteroids in the survey have higher water contents, consistent with CM chondrites. This strengthens the connection between CM chondrites and G asteroids that was proposed by Burbine. We find that the 0.7 microns and 3 microns band depths are correlated for the population of target objects.

Rivkin, A. S.↗

Hydrogen Concentrations on C-class Asteroids Derived from Remote Sensing

We present spectroscopic observations of 16 asteroids from 1.9-3.6 microns collected from the United Kingdom Infrared Telescope (UKIRT) from 1996-2000. Of these 16 asteroids, 11 show some evidence of a 3 micron hydrated mineral absorption feature greater than 2 sigma at 2.9 microns. Using relations first recognized for carbonaceous chondrite powders by Miyamoto and Zolensky (1994) and Sato et al. (1997), we have determined the hydrogen to silicon ratio for these asteroids and calculated their equivalent water contents, assuming all the hydrogen was in water. The asteroids split into 2 groups, roughly defined as equivalent water contents greater than approximately 7% (8 asteroids, all with 3 micron band depths greater than approximately 20%) and less than approximately 3% for the remaining 8 asteroids. This latter group includes some asteroids for which a weak but statistically significant 3 micron band of non-zero depth exists. The G-class asteroids in the survey have higher water contents, consistent with CM chondrites. This strengthens the connection between CM chondrites and G asteroids that was proposed by Burbine (1998). We find that the 0.7 micron and 3 micron band depths are correlated for the population of target objects.

Rivkin, A. S.↗

Hydrogen Concentrations on C-class Asteroids from Remote Sensing

We present spectroscopic observations of 16 asteroids from 1.9-3.6 microns, collected from the United Kingdom Infrared Telescope (UKIRT) from 1996-2000. Of these 16 asteroids, 11 show some evidence of a 3-micron hydrated mineral absorption feature greater than 2 sigma at 2.9 microns. Using relations first recognized for carbonaceous chondrite powders by Miyamoto and Zolensky (1994) and Sato et al. (1997), we have determined the hydrogen/silicon ratio for these asteroids and calculated their equivalent water contents, assuming all the hydrogen was in water. The asteroids split into two groups, roughly defined as equivalent water contents of greater than approx. 7% (eight asteroids) and less than approx. 3 % (the remaining eight asteroids). This latter group includes some asteroids for which there is a small but statistically significant 3-micron band of non-zero depth. The G-class asteroids in the survey have higher water contents, consistent with CM chondrites. This strengthens the connection between CM chondrites and G asteroids that was proposed by Burbine (1998). We find that the 0.7-micron and 3-micron band depths are correlated for the population of target objects.

Rivkin, A. S.↗

Materials Compatibility Testing in Concentrated Hydrogen Peroxide

Materials test methods from the 1960's have been used as a starting point in evaluating materials for today's space launch vehicles. These established test methods have been modified to incorporate today's analytical laboratory equipment. The Orbital test objective was to test a wide range of materials to incorporate the revolution in polymer and composite materials that has occurred since the 1960's. Testing is accomplished in 3 stages from rough screening to detailed analytical tests. Several interesting test observations have been made during this testing and are included in the paper. A summary of the set-up, test and evaluation of long-term storage sub-scale tanks is also included. This sub-scale tank test lasted for a 7-month duration prior to being stopped due to a polar boss material breakdown. Chemical evaluations of the hydrogen peroxide and residue left on the polar boss surface identify the material breakdown quite clearly. The paper concludes with recommendations for future testing and a specific effort underway within the industry to standardize the test methods used in evaluating materials.

Boxwell, R.↗