Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydronic heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heat Pump Retrofits for Central Plant Hydronic Heating Systems: A Software Toolkit for Screening and Design

Retrofitting existing central plants with high-efficiency heat pump technologies can play a crucial role in achieving long-term planning goals. Modern heat pump technologies are able to use waste heat recovery to meet a building's heating demand, but there is a lack of accessible tools designed for non-HVAC experts, such as building owners, to quickly and easily conduct what-if analysis, e.g., estimating retrofit costs and payback period for their partial or full equipment replacement. This paper introduces an open-source software toolkit designed to facilitate the initial screening and decision-making of heat pump retrofits in existing central plants using a building's yearly load profile from metered or utility bill data. The toolkit evaluates the technical and economic viability of replacing traditional central plant equipment with various options including water-to-water or air-to-water heat pumps, which can provide efficient and lower-cost heating and cooling. It allows users to compare current central plant configurations with retrofit scenarios, assessing energy consumption, life-cycle costs, and environmental impact. The toolkit offers (1) a web-based tool designed for user-friendly access by a broad audience and (2) Python-based source code for researchers and engineers conducting parametric studies and design parameter optimization. The toolkit compares a typical central plant configuration to a configuration that uses a heat pump to supply hydronic heating and cooling. The output metrics include energy consumption and output of each equipment, life-cycle cost analyses and metrics, and environmental impact of the system.

Excell, L↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Experimental study of a tri-functional propane hydronic heat pump

This study investigates the performance of a propane hydronic heat pump system for space cooling, heating, and water heating applications, focusing on various operational conditions, with a total refrigerant charge below 1200 g. Cooling performance was evaluated at different outdoor temperatures, compressor stages (capacity levels), and water flow rates. The results showed that the coefficient of performance (COP) for cooling was higher at lower outdoor temperatures, with peak values exceeding 5.0 under low-stage operation and lower water flow rate. The cooling capacity increased with higher flow rates and compressor stages, reaching 12 kW. Space heating performance, evaluated at ambient temperatures ranging from −8.3 °C to 16.7 °C, revealed a decrease in COP with lower temperatures. However, high-stage operation maintained higher heating capacities even at low temperatures. The system demonstrated high Heating Seasonal Performance Factors (HSPF), exceeding 10.0. For water heating, the COP decreased with lower ambient temperatures and higher supply water temperatures. The system efficiently heated an 189-L water tank, outperforming conventional water heaters, with process COPs exceeding 4.0 under cooling-season conditions. Despite some efficiency loss due to defrosting at low temperatures, the propane heat pump consistently delivered strong performance. Seasonal energy efficiency ratios (SEER) and seasonal heating COP values indicated significant overall efficiency. The study concludes that propane is a promising refrigerant for heat pump systems, with future research needed to future reduce total system charge and optimize system performance through advanced controls and heat exchanger designs.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installation package for integrated programmable electronic controller and hydronic subsystem - solar heating and cooling

A description is given of the Installation, Operation, and Maintenance Manual and information on the power panel and programmable microprocessor, a hydronic solar pump system and a hydronic heating hot water pumping system. These systems are integrated into various configurations for usages in solar energy management, control and monitoring, lighting control, data logging and other solar related applications.

Source record↗

Klickitat Valley Health Central Utility Plant Modernization

This project replaced legacy heating and cooling equipment at Klickitat Valley Health (KVH), a rural hospital in Goldendale, Washington. Work included constructing a new chiller building, installing modern hydronic piping systems, replacing the main Emergency Department air handler (Air Handlining Unit (AHU-1)), upgrading electrical systems, and converting the Emergency Department wing from electric reheat to hydronic heating and cooling. Commissioning, testing, adjusting, and balancing were completed under this grant. These upgrades improve energy efficiency, operational resilience, and system reliability while preparing the campus for future electrification and renewable energy integration. They also support growth in healthcare services for a rural population. The project directly reduces energy costs and provides a foundation for future decarbonization measures, including a FEMA-funded microgrid and a large-scale ground source heat pump (GSHP) project. These follow-on initiatives would not have been possible without the hydronic backbone built through this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Considerations for Ground Source Heat Pumps in Cold Climates: Preprint

Remote, cold climates present challenges to finding safe and affordable options to heat homes. In Alaska, residential ground source heat pumps (GSHPs) have been gaining in popularity to fill this gap. However, there is little research on their long-term performance or effect on soil temperatures. The extended heating season and cold soils of Alaska provide a harsh testing ground for GSHPs, even those designed and marketed for colder climates. The large and unbalanced heating load of cold climates creates a challenging environment for GSHPs. In 2013 the Cold Climate Housing Research Center (CCHRC) installed a GSHP at its Research and Testing Facility (RTF) in Fairbanks, Alaska. The heat pump replaced an oil-fired condensing boiler heating a 464 m2 office space via an in-floor hydronic radiant heating system. The ground heat exchanger (GHE) was installed in moisture-rich silty soils underlain with permafrost near 0°C. The intent of the installation was to observe and monitor the system over a 10-year period in order to develop a better understanding of the performance of GSHPs in sites with permafrost and to help inform future design. As of this writing, the heat pump system has been running for seven heating seasons. The efficiency in those seven heating seasons has been variable with ups and downs that have been difficult to explain. This paper seeks to understand the variability in performance as well as make recommendations for GSHP use in other cold climates.

cold climate↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Preliminary design package for residential heating/cooling system: Rankine air conditioner redesign

A summary of the preliminary redesign and development of a marketable single family heating and cooling system is presented. The interim design and schedule status of the residential (3-ton) redesign, problem areas and solutions, and the definition of plans for future design and development activities were discussed. The proposed system for a single-family residential heating and cooling system is a single-loop, solar-assisted, hydronic-to-warm-air heating subsystem with solar-assisted domestic water heating and a Rankine-driven expansion air-conditioning subsystem.

Source record↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗