SEARCH · Search NASA
Results for “ICP MASS SPECTROSCOPY”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Research Program for Fission Product/Dust Transport in HTGR’s
High and Very High Temperatures Gas Reactors (HTGRs/VHTRs) have five barriers to fission product (FP) release: the TRISO fuel coating, the fuel elements, the core graphite, the primary coolant system, and the reactor building. This project focused on measurements and computations of FP diffusion in graphite, FP adsorption on graphite and FP interactions with dust particles of arbitrary shape. Diffusion Coefficients of Cs and Iodine in two nuclear graphite were obtained by the release method and use of Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) and Instrumented Neutron Activation Analysis (INAA). A new mathematical model for fission gas release from nuclear fuel was also developed. Several techniques were explored to measure adsorption isotherms, notably a Knudsen Effusion Mass Spectrometer (KEMS) and Instrumented Neutron Activation Analysis (INAA). Some of these measurements are still in progress. The results will be reported in a supplemental report later. Studies of FP interactions with dust and shape factors for both chain-like particles and agglomerates over a wide size range were obtained through solutions of the diffusion and transport equations. The Green's Function Method for diffusion and Monte Carlo technique for transport were used, and it was found that the shape factors are sensitive to the particle arrangements, and that diffusion and transport of FPs can be hindered. Several journal articles relating to the above work have been published, and more are in submission and preparation.
Collaborative Proposal: DUSEL R&D at the Kimballton Underground Facility (ICP-MS Confirmation, Material Assay, and Radon Reduction)
Experiments measuring rare events, such as neutrinoless double beta (0{nu}{beta}{beta}) decay, and those searching for, or measuring very weakly interacting particles, such as low energy solar neutrino experiments or direct dark matter searches, require ever lower backgrounds; particularly those from radioactive contamination of detector materials. The underground physics community strives to identify and develop materials with radioactive contamination at permissible levels, and to remove radioactive contaminants from materials, but each such material represents a separate dedicated research and development effort. This project attempted to help these research communities by expanding the capabilities in the United States, for indentifying low levels of radioactive contamination in detector materials through gamma ray spectroscopy. Additionally the project tried to make a cross comparison between well established gamma ray spectroscopy techniques for identifying radioactive contaminations and Inductively Coupled Plasma Mass Spectroscopy, which is a relatively new method for searching for uranium and thorium in materials. The project also studied the removal of radioactive radon gas for laboratory air, which showed that an inexpensive technologically simple radon scrubber can potentially be used for homes or businesses with high radon levels even after the employment of other mitigation techniques.
Separation of thorium (IV) from lanthanide concentrate (LC) and water leach purification (WLP) residue
Thorium (IV) content in industrial residue produced from rare earth elements production industry is one of the challenges to Malaysian environment. Separation of thorium from the lanthanide concentrate (LC) and Water Leach Purification (WLP) residue from rare earth elements production plant is described. Both materials have been tested by sulphuric acid and alkaline digestions. Th concentrations in LC and WLP were determined to be 1289.7 ± 129 and 1952.9±17.6 ppm respectively. The results of separation show that the recovery of Th separation from rare earth in LC after concentrated sulphuric acid dissolution and reduction of acidity to precipitate Th was found 1.76-1.20% whereas Th recovery from WLP was less than 4% after concentrated acids and alkali digestion processes. Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) was used to determine Th concentrations in aqueous phase during separation stages. This study indicated that thorium maybe exists in refractory and insoluble form which is difficult to separate by these processes and stays in WLP residue as naturally occurring radioactive material (NORM)
Combined Methods of Analysis of Metal-Containing Raw Material (Review)
Methods of analysis of reusable metal-containing material (RMR) are considered in the review: X-ray fluorescence, atomic absorption spectrophotometry, and atomic emission and mass spectrometry with inductively coupled plasma. Peculiarities of the applied methods are shown, and a method of analysis with consideration of the specificity of RMR should be developed for every object. In the most cases, the methods of sample processing harmonized with the applied method of analysis and sample content.
Magnetite nanoparticles coated glass wool for As(V) removal from drinking water
Arsenic (As) removal from contaminated groundwater is a key environmental concern worldwide. In this study, glass wool was coated with magnetite nanoparticles under argon gas flow and magnetite coated glass wool have been investigated for application as an adsorbent for As(V) removal from water. The adsorbent was characterized by using Scanning Electron Microscopy (SEM) and arsenic contaminated water treated with adsorbent was analyzed by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The ICP-MS results showed that 10 g/L of adsorbent removed 99.4% of As(V) within 5 hours at pH-7 and initial arsenic concentration of 360µg/L. Adsorption kinetics data fitted well in pseudo-first-order kinetics model with high correlation coefficient (R{sup 2} = 0.995). As magnetite nanoparticles coated glass wool showed favorable adsorption behavior for As(V), it can be a promising tool for water purification.
Elevated levels of plasma Big endothelin-1 and its relation to hypertension and skin lesions in individuals exposed to arsenic
Chronic arsenic (As) exposure affects the endothelial system causing several diseases. Big endothelin-1 (Big ET-1), the biological precursor of endothelin-1 (ET-1) is a more accurate indicator of the degree of activation of the endothelial system. Effect of As exposure on the plasma Big ET-1 levels and its physiological implications have not yet been documented. We evaluated plasma Big ET-1 levels and their relation to hypertension and skin lesions in As exposed individuals in Bangladesh. A total of 304 study subjects from the As-endemic and non-endemic areas in Bangladesh were recruited for this study. As concentrations in water, hair and nails were measured by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The plasma Big ET-1 levels were measured using a one-step sandwich enzyme immunoassay kit. Significant increase in Big ET-1 levels were observed with the increasing concentrations of As in drinking water, hair and nails. Further, before and after adjusting with different covariates, plasma Big ET-1 levels were found to be significantly associated with the water, hair and nail As concentrations of the study subjects. Big ET-1 levels were also higher in the higher exposure groups compared to the lowest (reference) group. Interestingly, we observed that Big ET-1 levels were significantly higher in the hypertensive and skin lesion groups compared to the normotensive and without skin lesion counterpart, respectively of the study subjects in As-endemic areas. Thus, this study demonstrated a novel dose–response relationship between As exposure and plasma Big ET-1 levels indicating the possible involvement of plasma Big ET-1 levels in As-induced hypertension and skin lesions. -- Highlights: ► Plasma Big ET-1 is an indicator of endothelial damage. ► Plasma Big ET-1 level increases dose-dependently in arsenic exposed individuals. ► Study subjects in arsenic-endemic areas with hypertension have elevated Big ET-1 levels. ► Study subjects with arsenic-induced skin lesions show elevated plasma Big ET-1 levels. ► Arsenic-induced hypertension and skin lesions may be linked to plasma Big ET-1 levels.
Cs absorption capacity and selectivity of crystalline and amorphous Hf and Zr phosphates
Removal of radioactive Cs from sodium-rich solutions is a technical challenge that goes back to post World War II nuclear waste storage and treatment; and interest in this topic was reinvigorated by the Fukushima-Daiichi nuclear power plant disaster, 10 years ago. Since the 1960's there has been considerable focus on layered Zr phosphates as robust inorganic sorbents for separation of radionuclides such as Cs. Here we present synthesis and characterization, and direct comparison of Cs sorption capacity and selectivity of four related materials: 1) crystalline α-Zr phosphate and α-Hf phosphate, and 2) amorphous analogues of these. Powder X-ray diffraction, thermogravimetry, solid-state 31P magic angle spinning nuclear magnetic resonance (MAS-NMR) spectroscopy, and compositional analysis (inductively coupled plasma optical emission spectroscopy and mass spectroscopy, ICP OES and ICP MS) provided formulae; respectively M(HPO4)2∙1H2O and M(HPO4)2∙4H2O (M = Hf, Zr) for crystalline and amorphous analogues. Maximum Cs loading, competitive Cs-Na selectivity and maximum Cs-Na loading followed by the above characterizations plus 133Cs MAS-NMR spectroscopy revealed that amorphous analogues are considerably better Cs-sorbents (based on maximum Cs-loading and selectivity over Na) than the well-studied crystalline Zr-analogue. Additionally, crystalline α-Hf phosphate is better Cs-sorbent than crystalline α-Zr phosphate. All these studies consistently show that Hf phosphate is less crystallize than Zr phosphate, when obtained under similar or identical synthesis conditions. We attribute this to lower solubility of Hf phosphate compared to Zr phosphate, preventing ‘defect healing’ during the synthesis process.
Metal vapor target for precise studies of ion-atom collisions
Although different ion-atom collisions have been studied in various contexts, precise values of cross-sections for many atomic processes were seldom obtained. One of the main uncertainties originates from the value of target densities. In this paper, we describe a unique method to measure a target density precisely with a combination of physical vapor deposition and inductively coupled plasma optical emission spectrometry. This method is preliminarily applied to a charge transfer cross-section measurement in collisions between highly charged ions and magnesium vapor. The final relative uncertainty of the target density is less than 2.5%. This enables the precise studies of atomic processes in ion-atom collisions, even though in the trial test the deduction of precise capture cross-sections was limited by other systematic errors.
Compilation of LLNL CUP-2 Data
The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results indicate that the CUP-2 standard has a natural isotopic ratio, and does not appear to have been isotopically enriched or depleted in any way, and was not contaminated by a source of uranium with a non-natural isotopic composition. Furthermore, the lack of 233 U and 236 U above the instrumental detection limit indicates that this sample was not exposed to a neutron flux, which would have generated one or both of these isotopes in measurable concentrations.
Characterization Techniques for TRU Waste from the Analytical Laboratory Hot Cells at Idaho National Laboratory - 19610
Since the first reactor went hot in 1942, there has been a never ending desire to improve the nuclear reactor and the fuel that it burns. The Idaho National Laboratory has been a key player in reactor and fuel development. As more research projects begin, the spectrum of waste parameters grows. Over the years, the Analytical laboratory (AL) at the INL Materials and Fuels Complex (MFC) has supported a large range of various research projects. Each project brings its own challenge and analytical technique that, in turn, yields its own unique waste parameters. The AL Hot Cells at INL consist of 6 small cells that can support around 12 different fuel research projects at a time along with infrastructure and environmental samples. Each different project yields different levels of transuranic (TRU) material, RCRA constituents, dose, and contamination levels. The waste parameters from each project dictate a path forward for the waste as Low-Level Waste (LLW), Contact Handled TRU (CH-TRU), Mixed Contact Handled TRU (M-CH-TRU), Remote Handled TRU (RH-TRU), or Mixed Remote Handled TRU (M-RHTRU). With visual examination techniques and process knowledge as an aid, there have been waste handling methods developed that allow debris and sample material to be segregated. Unique characterization mechanisms have been applied for each debris and sample material that are generally more accurate than smear and surface contamination data. For debris found in the Hot Cells, analytical data is gathered and conservatively summarized for each fuel type and research method. This consists of data from Quadrupole Inductively Coupled Plasma Mass Spectrometry (Q-ICP-MS), Gamma Spectroscopy, and some data verification through Thermal Ionization Mass Spectrometry (TIMS) and Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS). This data gives a range of TRU isotope concentrations. Fuel age is taken into account to determine the dominant TRU activity isotopes. Cesium concentrations are also gathered. Each parameter/fuel type then ties a measured Cesium number to TRU content based on historical analytical data. Debris in the hot cells is segregated by project and packaged in individual 2 gallon metal paint cans. Each can is counted by gamma spectroscopy in a calculated and measured geometry. Using process knowledge to determine the fuel or project type, newly counted cesium numbers can be applied to the historic analytical data and TRU content can be estimated. The TRU content allows waste debris to be segregated between CH-TRU and RH-TRU. Packaging techniques can allow for the minimization of RHTRU waste. Sample material received into the AL must be dissolved into a liquid matrix in order to be analyzed in most cases. When analysis is complete, these liquids go through a consolidation, complexation, neutralization, and solidification process where real time analytical data can be used to calculate TRU content and RCRA constitutes. These calculations allow for no further analytical data to be gathered. The waste matrix is considered stable and acceptable by all Acceptable Knowledge (AK) documents. The unique techniques used in characterizing and handling the Analytical Laboratories Hot Cell waste can be applied to various situations and various laboratories. They allow for more accurate data for waste constituents and also for the minimization of RH-TRU waste. (authors)
Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations
The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.
Systems-based approach to understanding Technetium immobilization in the subsurface - 15326
The purpose of this work is to identify the chemical and biological reactions that occur and potentially influence the mobility of Technetium (Tc-99) in the subsurface. Tc-99 is a by-product of nuclear fission processes and has a relatively long half-life (t{sub 1/2}=212,000 years); additionally, it is highly soluble and mobile in groundwater and is most often remediated through pump and treat systems. The oxidized form of Tc-99 [Pertechnetate, Tc(VII)O{sub 4}-] is highly soluble and very mobile, while the reduced form of Tc-99 [Technetium-oxide, Tc(IV)O{sub 2}·nH{sub 2}O] is insoluble. Historically, complex interactions within the subsurface have made clean-up efforts for Tc-99 challenging. It is thought that environmental bacteria play a role in reducing contaminants to less soluble forms but it is difficult to predict or estimate the interactions and impacts of the complex, mixed microbial communities found in the environment. We have set up controlled batch experiments to examine a selection of organisms (Anaeromyxobacter dehalogenans strain CP-C, Geobacter sulfurreducens strain PAC, Geobacter daltonii strain FRC-32, and Shewanella oneidensis strain MR1) that have known metal reducing capabilities, for their ability to reduce Tc-99 to less soluble forms. An additional organism, Cellulomonas strain ES6 was chosen based on its origin of isolation from the Hanford site. Organisms were evaluated under anaerobic conditions both as isolates and in mixed consortia with and without the presence of iron-bearing mineral substrate. Experiments were monitored using spectroscopy, qPCR, volatile organic acid (VOA) analysis, and inductively coupled plasma-optical emission spectroscopy (ICP-OES) and mass spectrometer techniques (ICP-MS). Initial data collected has shown that the presence and type of substrate may increase the reduction of Tc-99 to less mobile forms. Data collected from these experiments will allow for (a) a better understanding of the mobility of Tc-99 in the subsurface, (b) better predictions of contaminant fate and transport over time, and (c) the development of long term remediation strategies for Tc-99. Additionally, information collected will be used to develop a systems-based metabolic model with predictive capabilities. (authors)
Enhancement of electrical parameters in solar grade monocrystalline silicon by external gettering through sacrificial silicon nanowire layer
Highlights: • Silicon nanowire-based gettering process decreases the metallic impurity concentration. • Gettering process ameliorates the transport parameters of silicon substrates. • The electrical properties of silicon solar cells are significantly improved. - Abstract: In this work, we report a simple and efficient purification technique of solar grade silicon wafers suitable for high efficiency and low-cost silicon solar cells. This gettering method requires the elaboration of silicon nanowire thin layer followed by an annealing treatment and removing impurity loaded silicon nanowires. ICP-AES analysis shows a significant decrease in the metallic impurity concentration resulting considerable enhancement in the silicon purity grade. Electrical characterizations reveal a global decrease of the majority carrier concentration and a substantial improvement of the minority carrier lifetime. Furthermore, the application of this novel gettering process induces an enhancement in the silicon solar cell electrical parameters. These results give evidence of the effectiveness of the proposed purification method to produce efficient solar cells starting from low-quality silicon wafers.
Solid solution between Al-ettringite and Fe-ettringite (Ca{sub 6}[Al{sub 1-x}Fe{sub x}(OH){sub 6}]{sub 2}(SO{sub 4}){sub 3}.26H{sub 2}O)
The solid solution between Al- and Fe-ettringite Ca{sub 6}[Al{sub 1-x}Fe{sub x}(OH){sub 6}]{sub 2}(SO{sub 4}){sub 3}.26H{sub 2}O was investigated. Ettringite phases were synthesized at different Al/(Al + Fe)-ratios (= X{sub Al,total}), so that X{sub Al} increased from 0.0 to 1.0 in 0.1 unit steps. After 8 months of equilibration, the solid phases were analyzed by X-ray diffraction (XRD) and thermogravimetric analysis (TGA), while the aqueous solutions were analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). XRD analyses of the solid phases indicated the existence of a miscibility gap between X{sub Al,total} = 0.3-0.6. Some of the XRD reflections showed two overlapping peaks at these molar ratios. The composition of the aqueous solutions, however, would have been in agreement with both, the existence of a miscibility gap or a continuous solid solution between Al- and Fe-ettringite, based on thermodynamic modeling, simulating the experimental conditions.
Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry
Laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA) inductively coupled plasma (ICP) mass spectrometry (MS) were utilized for microspatial analyses of a prehistoric bear (Ursus arctos) tooth dentine. The distribution of selected trace elements (Sr, Ba, Fe) was measured on a 26 mmx15 mm large and 3 mm thick transverse cross section of a canine tooth. The Na and Mg content together with the distribution of matrix elements (Ca, P) was also monitored within this area. The depth of the LIBS craters was measured with an optical profilometer. As shown, both LIBS and LA-ICP-MS can be successfully used for the fast, spatially resolved analysis of prehistoric teeth samples. In addition to microchemical analysis, the sample hardness was calculated using LIBS plasma ionic-to-atomic line intensity ratios of Mg (or Ca). To validate the sample hardness calculations, the hardness was also measured with a Vickers microhardness tester.
Utilizing rare earth elements as tracers in high TDS reservoir brines in CCS applications
In this paper we report the result of research associated with the testing of a procedures necessary for utilizing natural occurring trace elements, specifically the Rare Earth Elements (REE) as geochemical tracers in Carbon Capture and Storage (CCS) applications. Trace elements, particularly REE may be well suited to serve as in situ tracers for monitoring geochemical conditions and the migration of CO₂-charged waters within CCS storage systems. We have been conducting studies to determine the efficacy of using REE as a tracer and characterization tool in the laboratory, at a CCS analogue site in Soda Springs, Idaho, and at a proposed CCS reservoir at the Rock Springs Uplift, Wyoming. Results from field and laboratory studies have been encouraging and show that REE may be an effective tracer in CCS systems and overlying aquifers. In recent years, a series of studies using REE as a natural groundwater tracer have been conducted successfully at various locations around the globe. Additionally, REE and other trace elements have been successfully used as in situ tracers to describe the evolution of deep sedimentary Basins. Our goal has been to establish naturally occurring REE as a useful monitoring measuring and verification (MMV) tool in CCS research because formation brine chemistry will be particularly sensitive to changes in local equilibrium caused by the addition of large volumes of CO₂. Because brine within CCS target formations will have been in chemical equilibrium with the host rocks for millions of years, the addition of large volumes of CO₂ will cause reactions in the formation that will drive changes to the brine chemistry due to the pH change caused by the formation of carbonic acid. This CO₂ driven change in formation fluid chemistry will have a major impact on water rock reaction equilibrium in the formation, which will impart a change in the REE fingerprint of the brine that can measured and be used to monitor in situ reservoir conditions. Our research has shown that the REE signature imparted to the formation fluid by the introduction of CO₂ to the formation, can be measured and tracked as part of an MMV program. Additionally, this REE fingerprint may serve as an ideal tracer for fluid migration, both within the CCS target formation, and should formation fluids migrate into overlying aquifers. However application of REE and other trace elements to CCS system is complicated by the high salt content of the brines contained within the target formations. In the United States by regulation, in order for a geologic reservoir to be considered suitable for carbon storage, it must contain formation brine with total dissolved solids (TDS) > 10,000 ppm, and in most cases formation brines have TDS well in excess of that threshold. The high salinity of these brines creates analytical problems for elemental analysis, including element interference with trace metals in Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) (i.e. element mass overlap due to oxide or plasma phenomenon). Additionally, instruments like the ICP-MS that are sensitive enough to measure trace elements down to the parts per trillion level are quickly oversaturated when water TDS exceeds much more than 1,000 ppm. Normally this problem is dealt with through dilution of the sample, bringing the water chemistry into the instruments working range. However, dilution is not an option when analyzing these formation brines for trace metals, because trace elements, specifically the REE, which occur in aqueous solutions at the parts per trillion levels. Any dilution of the sample would make REE detection impossible. Therefore, the ability to use trace metals as in situ natural tracers in high TDS brines environments requires the development of methods for pre-concentrating trace elements, while reducing the salinity and associated elemental interference such that the brines can be routinely analyzed by standard ICP-MS methods. As part of the Big Sky Carbon Sequestration Project the INL-CAES has developed a rapid, easy to use process that pre-concentrates trace metals, including REE, up to 100x while eliminating interfering ions (e.g. Ba, Cl). The process is straightforward, inexpensive, and requires little infrastructure, using only a single chromatography column with inexpensive, reusable, commercially available resins and wash chemicals. The procedure has been tested with synthetic brines (215,000 ppm or less TDS) and field water samples (up to 5,000 ppm TDS). Testing has produced data of high quality with REE capture efficiency exceeding 95%, while reducing interfering elements by > 99%.
Role of Ti Content on the Occurrence of the 3309-cm{sup –1} Peak in FTIR Absorption Spectra of Ruby Samples
The study is based on the determination of trace elements in ruby samples, Ti in particular, using laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS). The samples were then divided into three groups: high (≥ 200 ppma), moderate (100–200 ppma), and low (≤ 50 ppma) Ti content. In addition, X-ray absorption spectroscopy (XAS) was employed to confirm that the Ti oxidation state was Ti{sup 4+}. The heat experiment conditions were set at 800, 1200, and 1650°C to investigate the transformation of the –OH vibration in the FTIR spectra of ruby samples. The FTIR spectra showed that samples containing a low Ti concentration did not show the 3309-cm{sup –1} absorption peak either before or after heating at any of the designed temperatures. An obvious 3309-cm{sup –1} peak appeared only in samples with a moderate to high Ti content after heating at ≥ 1200°C. The results also suggest that, in addition of Ti{sup 4+}, the occurrence of the 3309-cm{sup –1} peak in the FTIR spectra is strongly affected by the charge compensation of –OH in Al sites, i.e., the structural –OH; thus, the structural –Ti–OH stretching in the ruby samples. Hence, for gemological identification, the 3309-cm{sup –1} peak can be applied to indicate whether a ruby has undergone heat treatment if those samples contain enough Ti ions in their structure, i.e., Ti ≥ 100 ppma. This condition is usually found in ruby samples from major deposits such as Mong Hsu and Mogok, Myanmar; Luc Yen, Vietnam; and Montopuez, Mozambique.