Search NASA⌕ Search

SEARCH · Search NASA

Results for “ICP mass spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nanoscale trace-element zoning in pyrite framboids and implications for paleoproxy applications

Pyrite framboids (spherical masses of nanoscale pyrite) are among the earliest textures of pyrite to form in sediments. It has been proposed that their trace-element (TE) contents can be used to track the TE composition of the water column in which they formed. However, it is not clear how these TEs are associated with the framboidal pyrite grains. For instance, it is important to know whether they are incorporated uniformly or are enriched in different regions of the framboid. Here, we used high-resolution scanning transmission electron microscopy to identify chemical zoning within pyrite framboids. We found that initial, nanoscale pyrite euhedral crystals, which make up the volumetric majority of the framboids, are covered/infilled by later pyrite that templates on the earlier pyrite. Further, this later pyrite is enriched in TEs, suggesting that many TEs are incorporated in pyrite relatively late (during early diagenesis; not in the water column). This observation suggests that although chemical analyses of pyrite framboids may provide ocean-water chemistry trends through time, the details are complex. Specifically, the TEs found in pyrite may be linked to adsorption onto organic matter, detrital material, and authigenic minerals such as Fe- and Mn-oxide phases followed by desorption in the sediments or release via dissolution and incorporation into pyrite as overgrowths on the initial nanoscale euhedral crystals that make up framboids. While the use of pyrite chemistry to understand past ocean conditions remains promising, and even diagenetic additions may not preclude the utility of pyrite for reconstructing ancient ocean conditions, care must be taken in interpretations because the end concentration may be influenced by diagenesis.

58 GEOSCIENCES↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

High Precision and Spatial Resolution Chemical Interrogation of Planetary Materials Using fs-LA/LIBS in Tandem With Multi-Collector ICP-MS

Combining femtosecond laser ablation (fs-LA) with laser-induced breakdown spectroscopy (LIBS), together with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS), can provide remarkable insights into the composition, structure, and therefore geologic history of planetary materials and their terrestrial analogs. Using the Applied Spectra iX-fs-Tandem LA-LIBS Instrument and the Nu SP1700 MC-ICP-MS housed within the Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center, we present preliminary tandem fs-LA-(MC)-ICP-MS/LIBS measurements of planetary analog materials. The synergistic integration of fs-LA-LIBS offers high spatial resolution elemental mapping, enabling the identification of microscale variations within samples. Simultaneously, the MC-ICP-MS can deliver precise isotopic analyses, and integrating the two datasets yields a wealth of geochemical information for a given sample. LA-based chemical mapping experiment designs are contingent on the information sought (i.e., quantitative, or semi-quantitative) and the preferred or available volume of material removed for the analysis. For example, occasionally, there are significant limitations in the depth of ablation due to the sample value, the amount of material available, or simply the need to coordinate with other in-situ techniques. In these limited sample scenarios, the “depth-controlled” chemical maps allow for precise post-mapping ion-polishing of the sample, while the isotopic and elemental maps can be used for targeting future analyses (e.g., conventional LA analyses, SIMS analyses, and micro milling for solution ICP-MS/TIMS). The emerging methodology will establish a powerful tool for investigation of astromaterials and materials returned by future planetary sample science missions.

Jacob B Setera↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Crosslinked Polyethyleneimine Gel Polymer Interface to Improve Cycling Stability of RFBs

Redox flow batteries are considered a promising technology for grid energy storage. However, capacity decay caused by crossover of active materials is a universal challenge for many flow battery systems, which are based on various chemistries. In this paper, using the vanadium redox flow battery as an example, we demonstrate a new gel polymer interface (GPI) consisting of crosslinked polyethyleneimine with a large amount of amino and carboxylic acid groups introduced between the positive electrode and the membrane. The GPI functions as a key component to prevent vanadium ions from crossing the membrane, thus supporting stable long-term cycling. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements were conducted to investigate the effect of GPI on the electrochemical properties of graphitic carbon electrodes (GCFs) and redox reaction of catholyte. X-ray photoelectron spectroscopy (XPS) and 1 H nuclear magnetic resonance (NMR) spectra demonstrated that the crosslinked GPI is chemically stable for 100 cycles without dissolution of polymers and swelling in the strong acidic electrolytes. Results from inductively coupled plasma mass spectrometry (ICP-MS), Fourier-transform infrared (FTIR) spectroscopy, and energy-dispersive X-ray (EDX) spectroscopy proved that the GPI is effective in maintaining the concentration of vanadium species in their respective half-cells, resulting in improved cycling stability because of it prevents active species from crossing the membrane and stabilizes the oxidation states of active species.

Lim, Hyung-Seok↗

The impact of gas purity on observed reactivity with NO using inductively coupled plasma tandem mass spectrometry

Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.5%) with and without a gas purifier to reduce H 2 O impurities to <100 pptV. Experiments were performed using V, Ce, Tl and Th to investigate the effects of purified NO at various flowrates (0.22–1.49 mL min -1 ). Purified NO was shown to significantly mitigate oxy-hydride interferences, improve total ion sensitivity (notable at high gas flows), and shift product distributions advantageously. The reduction in oxy-hydride species results in a product distribution favoring the major expected products, where signals were shown to increase by an order of magnitude. Reduced background and increased signal for the major expected products provides avenues for improving various analytical applications of ICP-MS/MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

The Center for Isotope Cosmochemistry and Geochronology (CICG) at the NASA Johnson Space Center, led by Justin Simon, applies novel elemental and isotopic analytical techniques to understand solar system formation, from processes occurring during the earliest Solar Nebula, to the evolution of planetary bodies during planet formation and differentiation. CICG consists of an integrated suite of labs including dedicated spaces for specialized handling and preparation of meteorites and planetary return samples, metal-free clean chemistry, and mass spectrometry. In addition to a Thermo-Scientific Triton thermal ionization mass spectrometer (TIMS) for high precision isotopic analyses in processed samples, CICG houses two additional mass spectrometry instruments with added laser ablation capabilities for high spatial resolution in-situ measurements: (1) a Thermo-Scientific Element-XR inductively coupled mass spectrometer (ICP-MS) with a Teledyne Photon Machines Analyte Excite+ laser ablation system, and (2) a Nu Sapphire 1700 multi-collector ICP-MS, a large geometry instrument with a multi-pole collision cell for interference removal, with an Applied Spectra J200 tandem laser induced breakdown spectroscopy (LIBS) femto-second laser ablation system. We detail the analytical capabilities of CICG in the context of current and future research projects related to the studies of protoplanetary disk evolution via early-formed Solar System solids, volatile abundances and distribution within the inner solar system, and geochemical and temporal investigations related to planet formation and differentiation. We also highlight opportunities through the relationship with the Center of the Advancement of Space Safety and Mission Assurance Research (CASSMAR) at the University of Texas at El Paso. CICG is open to collaborations and participates in the NASA Facility for Astromaterials Research (NFAR) program, which accepts research proposals for access to the unique facility capabilities.

Jacob B. Setera↗

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Organic matter concentration and composition of experimentally burned open air and muffle furnace vegetation chars across differing burn severity and feedstock types from Pacific Northwest, USA (v4).

This dataset represents results from an experimental study designed to compare how the chemical composition of organic matter changes across different burn conditions and feedstock materials. The dataset provides both solid and dissolved phase bulk concentration and organic matter characterization data from experimentally generated chars. Chars were created in a closed muffle furnace or on an open burn table from four different feedstock species representing vegetation commonly impacted by fire regimes across the Pacific Northwest, USA. This data can be used to compare how different burn conditions may influence resultant organic matter chemistry and help further our understanding of potential biogeochemical impacts on river corridors post-fire. This dataset is comprised of one data package readme, one data dictionary (dd), one file level metadata (flmd), fourteen burn table videos, burn table video metadata and three folders containing (A) data; (B) metadata and protocols; and (C) photos. The folder names and the file name of the data package readme include a version number which will be updated with future iterations of this data package. The data folder includes (1) solid carbon and solid nitrogen; (2) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) and total dissolved nitrogen (TN); (3) pH; (4) thermocouple time series temperature; (5) methods codes; (6) installation methods; (7) excitation emissions matrix (EEM) methods information; (8) a folder of excitation emissions matrix (EEM) fluorescence and absorbance spectra in dissolved organic matter and EEMs processing instructions; (9) solid state carbon-13 and solution state phosphorus nuclear magnetic resonance (13-C NMR and 31-P NMR) data and methods; (10) benzene polycarboxylic acid (BPCA) concentration and stable isotope data; (11) FTICR-MS methods; (12) Inductively coupled plasma (ICP) data for total calcium, magnesium, iron, aluminum, potassium, phosphorus, sodium, and sulfur along with sodium hydroxide-ethylenediaminetetraacetic acid (sodium hydroxide-EDTA) extractable calcium, magnesium, iron, aluminum, potassium, phosphorus, and sulfur; (13) a folder of phosphorus, carbon, and nitrogen X-ray absorption near edge structure (P-XANES, N-XANES, C-XANES) data for samples and standards; (14) P-XANES, N-XANES, C-XANES methods; (15) molybdate reactive phosphorus; and (16) folder of high resolution characterization of organic matter via 21 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The FTICR folder contains .txt data files and a subfolder containing instruments for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. The metadata and protocols folder includes (1) international geo-sample number (IGSN) mapping file (2) burn and laboratory metadata; (3) burn protocol; (4) laboratory protocol; (5) vegetation collection metadata; and (6) vegetation collection protocol. The folder contains photos of the solid chars. All files are .csv, .txt, .pdf, .jpg, .jpeg, .R, .ref, or .mp4. The data package was originally published October 2022 (v1). It was updated April 2023 (v2; new data files), September 2023 (v3; new and corrected data files), and September 2024 (v4; new and added/updated files). Metadata files were also updated to reflect these changes. See the change history section in the readme for more details.

54 ENVIRONMENTAL SCIENCES↗

Microstructural Changes and Pb Mobility During the Zircon to Reidite Transformation: Implications for Planetary Impact Chronology

Impact events modify and leave behind a complex history of rock metamorphism on terrestrial planets. Evidence for an impact event may be recorded in physical changes to minerals, such as mineral deformation and formation of high P-T polymorphs, but also in the form of chemical fingerprints, such as enhanced elemental diffusion and isotopic mixing. Here we explore laboratory shock-induced physical and chemical changes to zircon and feldspar, the former of which is of interest because its trace elements abundances and isotope ratios are used extensively in geochemistry and geochronology. To this end, a granular mixture of Bishop Tuff sanidine and Kuehl Lake zircon, both with well characterized Pb isotope compositions, was prepared and then shocked via a flat plate accelerator. The peak pressure of the experiment, as calculated by the impedance matching method, was ~24 GPa although a broader range of P-T conditions is anticipated due to starting sample porosity. Unshocked and shocked materials were characterized via scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and Raman spectroscopy. These methods show that the starting zircon material had abundant metamict regions, and the conversion of the feldspar to glass in the post-shock material. Analyses of the shocked product also yielded multiple occurrences of the high-pressure ZrSiO 4 polymorph reidite, with some domains up to 300 μm across. The possibility of U-Pb system disturbance was evaluated via laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and secondary ion mass spectrometry (SIMS). The isotopic data reveal that disturbance of the U-Pb geochronometer in the reidite was minimal (<2% for the main U-Pb geochronometers). To better constrain the P-T conditions during the shock experiment, we complement impedance matching pressure calculations with iSALE2D impact simulations. The simulated results yield a range of P-T conditions experienced during the experiment and show that much of the sample may have reached >30 GPa, which is consistent with formation of reidite. In the recovered shocked material, we identified lamellae of reidite, some of which interlock with zircon lamellae. Reidite {112} twins were identified, which we interpret to have formed to reduce stress between the crystal structure of the host zircon and reidite. These two findings support the interpretation that shear transformation enabled the transition of zircon to reidite. The size and presence of reidite found here indicate that this phase is probably common in impact-shocked crustal rocks that experienced ~25 to ~35 GPa, especially when the target material has porosity. Additionally, shock loading of the zircon and transformation to reidite at these pressures in porous materials is unlikely to significantly disturb the U-Pb system in zircon and that the reidite inherits the primary U and Pb elemental and isotopic ratios from the zircon.

Bishop Tuff↗