Search NASASearch

SEARCH · Search NASA

Results for “IES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analytical evaluation of a surface integral expressing the coupling between interior and exterior volumes in a FE-IE approach

Recently an approach which combines the finite element technique and an integral equation to determine the fields scattered by inhomogeneous bodies of complicated shape has been proposed. Basically, a mathematical surface which encloses the scatterers is introduced, thus dividing the space into an interior and an exterior volume, in which the finite element technique and an integral equation for EM scattering, respectively, are applied. The integral equation is set up for the tangential components of the fields at the surface, while the interior volume the unknowns are the total fields. Continuity of the tangential fields at the boundary, as required by Maxwell's equations, is imposed, thus coupling the two methods to obtain a consistent solution. The coupling term is expressed by a surface integral formed by the dot product of a FE basis function and an IE testing function, or viceversa. By choosing the boundary to be a surface of revolution and by making a convenient selection of IE basis (testing) functions, it is possible to evaluate the integrals analytically on surfaces such as curved triangles, curved quadrilaterals and curved pentagons. We will illustrate the salient steps involved in setting up and carrying out these integrals and discuss what class of basis (testing) functions and analytic surfaces of revolution they are applicable to. Analytic calculations offer the advantage of better accuracy than purely numerical ones, and, when combined with them, often shed light on issues of numerical convergence and limiting values. Furthermore, they may reduce computation time and storage requirements.

Zuffada, C.

Imaging Electron Spectrometer (IES) Electron Preprocessor (EPP) Design

The Aerospace Corporation developed the Electron PreProcessor (EPP) to support the Imaging Electron Spectrometer (IES) that is part of the RAPID experiment on the ESA/NASA CLUSTER mission. The purpose of the EPP is to collect raw data from the IES and perform processing and data compression on it before transferring it to the RAPID microprocessor system for formatting and transmission to the CLUSTER satellite data system. The report provides a short history of the RAPID and CLUSTER programs and describes the EPP design. Four EPP units were fabricated, tested, and delivered for the original CLUSTER program. These were destroyed during a launch failure. Four more EPP units were delivered for the CLUSTER II program. These were successfully launched and are operating nominally on orbit.

Fennell, J. F.

On the Extended Emission of the Anomalous X-ray Pulsar IE 1547.0-5408

We present an analysis of the extended emission around the anomalous X-ray pulsar IE 1547.0-5408 using four XMM-Newton observations taken with the source in varying states of outburst as well as in quiescence. We find that the extended emission flux is highly variable and strongly correlated with the flux of the magnetar. Based on this result, as well as on spectral and energetic considerations, we conclude that the extended emission is dominated by a dust-scattering halo and not a pulsar wind nebula (P-VVN), as has been previously argued. We obtain an upper limit on the 2-10 keV flux of a possible PWN of 4.7 x 10(exp -14) erg/s/sq cm, three times less than the previously claimed value, implying an efficiency for conversion of spin-down energy into nebular luminosity of <9 x 10(exp -4) .

Olausen, S. A.

Forward-Looking IED Detector Ground Penetrating Radar

There have been many developments of mine or metal detectors based on ground penetrating radar techniques, usually in hand-held or rover-mounted devices. In most mine or metal detector applications, conditions are in a stationary mode and detection speed is not an important factor. A novel, forward-looking, stepped-frequency ground penetrating radar (GPR) has been developed with a capability to detect improvised explosive devices (IEDs) at vehicular speeds of 15 to 20 mph (24 to 32 km/h), 10 to 20 m ahead of the vehicle, to ensure adequate time for response. The GPR system employs two horn antennas (1.7 to 2.6 GHz, 20 dBi) as transmit and receive. The detector system features a user-friendly instantaneous display on a laptop PC and is a low-power-consumption (3 W) compact system with minimal impact on vehicle operations. In practice, the whole GPR system and a laptop PC can be powered by plugging into a cigarette lighter of a vehicle. The stepped-frequency continuous-wave (CW) radar scans frequency from 1.7 to 2.6 GHz in 1,000 steps of 0.9 MHz, with the full frequency scan in 60 ms. The GPR uses a bi-static configuration with one horn antenna used as a transmitter and the other used as a receiver so that isolation between transmitter and receiver is improved. Since the horn antennas (20 dBi) are mounted on the roof of a vehicle at a shallow inclination angle (15 to 25 with respect to horizontal), there is a first-order reduction in ground reflection so that a significant amount of the total reflected power received by the GPR comes from the scattering of RF energy off of buried objects. The stepped-frequency technique works by transmitting a tone at a particular frequency, while the received signal is mixed with the transmitted tone. As a result, the output of the mixer produces a signal that indicates the strength of the received signal and the extent to which it is in phase or out of phase with the transmitted tone. By taking measurements of the phase relationship between the transmitted and received signals over a wide frequency range, an interference pattern is produced showing all target reflections. When a Fourier transform is performed on this pattern, the result is a time-domain representation of targets. Among the advantages of this technique over impulse radar is the ability to transmit and receive much more total energy, and to use non-damped, highly focused horn antennas. The novelty of the IED detector GPR has been achieved by miniaturization of GPR electronics (single electronics board, 10x5x2 cm), low power consumption (3 W), faster signal processing capability, and minimal impact on vehicle operations.

Kim, Soon Sam

Rapid X-ray and optical variability in the X-ray selected BL Lacertae object IE 1402.3 + 0416

Results from X-ray and optical observations of the X-ray-discovered BL Lac object 1E 1402.3 + 0416 are presented, where the X-ray measurements were carried out with the Channel Multiplier Array (CMA) and Medium Energy experiment (ME) detectors on board Exosat. These measurements revealed an intensity decrease by a factor of two on a time scale of a few hours. At maximum flux, the source was significantly greater than at the time of the Einstein Image Proportional Counter (IPC) discovery observation. The 2-6 keV X-ray spectrum was determined by the ME experiment, and IPC, HRI, and CMA data were subsequently compared. The source varied over the years by a factor of five; its brightest state was within the last three years. It is noted that a redshift greater than 0.2 would require that anisotropic emission mechanisms be invoked.

Giommi, P.

No Nd-142 Excess in the Early Archean Isua Gneiss IE 715-28

There is abundant evidence for the existence of 146Sm in the early solar system and for preservation of effects in the 146Sm-142Nd system in differentiated meteorites ([1]; see recent discussion in Stewart et al. 1994). Information from the 182Hf-182W system, as revised by new careful work [2-3] also indicates that the Earth s core formed relatively early. It is in principle possible for early-formed crust and mantle reservoirs on Earth to have preserved evidence for 146Sm if such reservoirs were produced with high Sm/Nd fractionation and if they have remained isolated and closed since ~4.3 Ga. The mean life of 146Sm of 149 Ma is sufficiently long to make this an intriguing possibility.

Papanastassiou, D. A.

Handbook for Dynamic Data Acquisition and Analysis - IES Recommended Practices 012.1

The original motivation for this Handbook came from personnel of The Aerospace Corporation (TAC), who are technical advisors to the Air Force Space and Missile Systems Center. Over the preceding two decades, TAC has observed a seemingly endless series of errors and anomalies in the acquisition and analysis of structural dynamic and aeroacoustic data.

Shock vibration acoustic noise

Evidence for Water Ie on the Moon: Results for Anomalous Polar Craters from the LRO Mini-RF Imaging Radar

The Mini-RF radar instrument on the Lunar Reconnaissance Orbiter spacecraft mapped both lunar poles in two different RF wavelengths (complete mapping at 12.6 cm S-band and partial mapping at 4.2 cm X-band) in two look directions, removing much of the ambiguity of previous Earth- and spacecraft-based radar mapping of the Moon's polar regions. The poles are typical highland terrain, showing expected values of radar cross section (albedo) and circular polarization ratio (CPR). Most fresh craters display high values of CPR in and outside the crater rim; the pattern of these CPR distributions is consistent with high levels of wavelength-scale surface roughness associated with the presence of block fields, impact melt flows, and fallback breccia. A different class of polar crater exhibits high CPR only in their interiors, interiors that are both permanently dark and very cold (less than 100 K). Application of scattering models developed previously suggests that these anomalously high-CPR deposits exhibit behavior consistent with the presence of water ice. If this interpretation is correct, then both poles may contain several hundred million tons of water in the form of relatively "clean" ice, all within the upper couple of meters of the lunar surface. The existence of significant water ice deposits enables both long-term human habitation of the Moon and the creation of a permanent cislunar space transportation system based upon the harvest and use of lunar propellant.

polar

Asymmetric Magnetosphere Deformation Driven by Hot Flow Anomaly(ies)

We present a case study of a large deformation of the magnetopause on November 26, 2008. The investigation is based on observations of five THEMIS spacecraft located at the dawn flank in the magnetosphere and magnetosheath, on Cluster measurements at the dusk magnetosheath, and is supported by ACE solar wind monitoring. The main revelation of our study is that the interaction of the IMF discontinuity with the bow shock creates either one very elongated hot flow anomaly (HFA) or a pair of them that is (are) simultaneously observed at both flanks. Whereas the dusk HFA is weak and does not cause observable deformation of the magnetopause, the pressure variations connected with the dawn HFA lead to a magnetopause displacement by approx. = 5 R(sub E) outward from its nominal position. This is followed by a rapid inward motion of the magnetopause approx. = 4 R(sub E) inward with respect to the model location. The surface deformation is so large that the outermost THEMIS spacecraft was in the magnetosphere, whereas the spacecraft located 9 R(sub E) inbound entered into the magnetosheath at the same time. The whole event lasted about 5 minutes.

hot flow anomaly

Real-time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy

BACKGROUND: Infarct exclusion (IE) surgery, a technique of left ventricular (LV) reconstruction for dyskinetic or akinetic LV segments in patients with ischemic cardiomyopathy, requires accurate volume quantification to determine the impact of surgery due to complicated geometric changes. METHODS AND RESULTS: Thirty patients who underwent IE (mean age 61+/-8 years, 73% men) had epicardial real-time 3-dimensional echocardiographic (RT3DE) studies performed before and after IE. RT3DE follow-up was performed transthoracically 42+/-67 days after surgery in 22 patients. Repeated measures ANOVA was used to compare the values before and after IE surgery and at follow-up. Significant decreases in LV end-diastolic (EDVI) and end-systolic (ESVI) volume indices were apparent immediately after IE and in follow-up (EDVI 99+/-40, 67+/-26, and 71+/-31 mL/m(2), respectively; ESVI 72+/-37, 40+/-21, and 42+/-22 mL/m(2), respectively; P:<0.05). LV ejection fraction increased significantly and remained higher (0.29+/-0.11, 0.43+/-0.13, and 0.42+/-0.09, respectively, P:<0.05). Forward stroke volume in 16 patients with preoperative mitral regurgitation significantly improved after IE and in follow-up (22+/-12, 53+/-24, and 58+/-21 mL, respectively, P:<0.005). New York Heart Association functional class at an average 285+/-144 days of clinical follow-up significantly improved from 3.0+/-0.8 to 1.8+/-0.8 (P:<0.0001). Smaller end-diastolic and end-systolic volumes measured with RT3DE immediately after IE were closely related to improvement in New York Heart Association functional class at clinical follow-up (Spearman's rho=0.58 and 0.60, respectively). CONCLUSIONS: RT3DE can be used to quantitatively assess changes in LV volume and function after complicated LV reconstruction. Decreased LV volume and increased ejection fraction imply a reduction in LV wall stress after IE surgery and are predictive of symptomatic improvement.

Non-NASA Center

Influence of Exercise Modality on Cerebral-Ocular Hemodynamics and Pressures

Background: Moderate and high intensity aerobic or resistance exercise has clearly identified benefits for cardiac, muscle, and bone health. However, the impact of such exercise - either as a mitigating or an exacerbating factor - on the development of the visual impairment and intracranial pressure syndrome (VIIP) is unknown. Accordingly, our aim was to characterize the effect of an acute bout of resistance (RE), moderate-intensity continuous (CE), and high-intensity interval exercise (IE) during a cephalad fluid shift on cerebral-ocular hemodynamics and pressures. Methods: 10 male subjects (36 plus or minus 9 years) completed 4 testing days in a 15 degree head-down tilt (HDT): (1) assessment of maximum volume of O (sub 2), (2) RE session (4 sets of 12 repetition maximum leg press exercise), (3) CE session (30 minutes of cycling at 60 percent maximum volume of O (sub 2)), and (4) IE session (4 by 4-minute intervals of exercise at 85 percent maximum volume of O (sub 2) with 3-minute active rest periods). During each session, blood flow (Vivid-e, GE Healthcare) in extracranial arteries (common carotid artery, CCA; internal carotid artery, ICA; external carotid artery, ECA and vertebral artery, VA), and mean blood flow velocity in middle cerebral artery (MCA), internal jugular pressure (IJP; VeinPress), and intraocular pressure (IOP; Icare PRO) were measured at rest, at the end of each resistance or interval set, and every 5 minutes during continuous exercise. Translaminar pressure gradient (TLPG) was estimated by subtracting IJP from IOP. Results: There were no differences across days in pre-exercise resting blood flows or pressures. IOP decreased slightly from HDT rest (20.2 plus or minus 2.3 millimeters of mercury) to exercise (RE: 19.2 plus or minus 2.8 millimeters of mercury; CE: 18.9 plus or minus 3.2 millimeters of mercury; IE: 20.1 plus or minus 2.8 millimeters of mercury), while IJP decreased during CE (31.6 plus or minus 9.5 millimeters of mercury) and RE (32.0 plus or minus 8.1 millimeters of mercury), and increased during IE (35.1 plus or minus 9.5 millimeters of mercury) from HDT rest (33.3 plus or minus 6.5 millimeters of mercury). Estimated TLPG was increased during IE only. Compared to RE and CE, IE resulted in the greatest increase in MCA blood flow velocity and extracranial artery blood flow. Conclusions: These preliminary results suggest that high-intensity IE acutely increases cerebral blood flow, IJP, and TLPG. Alterations in TLPG is one mechanism that may contribute to optic nerve sheath edema in astronauts. Accordingly, acutely raising IOP and/or orbital pressure during exercise could optimize cerebral-ocular pressures during spaceflight.

Scott, J.