Search NASA⌕ Search

SEARCH · Search NASA

Results for “IGBT Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Energy Efficient Electronics Cooling Project

Parker Precision Cooling Business Unit was awarded a Department of Energy grant (DE-EE0000412) to support the DOE-ITP goal of reducing industrial energy intensity and GHG emissions. The project proposed by Precision Cooling was to accelerate the development of a cooling technology for high heat generating electronics components. These components are specifically related to power electronics found in power drives focused on the inverter, converter and transformer modules. The proposed cooling system was expected to simultaneously remove heat from all three of the major modules listed above, while remaining dielectric under all operating conditions. Development of the cooling system to meet specific customer's requirements and constraints not only required a robust system design, but also new components to support long system functionality. Components requiring further development and testing during this project included pumps, fluid couplings, cold plates and condensers. All four of these major categories of components are required in every Precision Cooling system. Not only was design a key area of focus, but the process for manufacturing these components had to be determined and proven through the system development.

42 ENGINEERING↗

Multi-Objective Optimization for Power Electronics used in Grid-Tied Energy Storage Systems

Multi-objective optimization is used to find a nondominated set of solutions for two conflicting performance metrics or objective functions. These functions are dependent variables in the system, controlled by a set of independent variables called decision variables. The decision variables represent the inputs to the problem, chosen by the system designer, and are values listed in the solution set. In this study, a multi-objective genetic algorithm compared insulated-gate bipolar transistor (IGBT) failure rate to filter and cooling system costs. This study demonstrated the use of multi-objective optimization for energy storage systems. IGBT failure rate was compared to its associated filter and cooling-system costs as part of the DC-AC inverter power electronics system in a battery energy storage system (BESS). The independent or decision variables were determined to be switching frequency and thermal resistance of a heat sink, R sink . The final results indicated that high values of switching frequency increased the effects of R sink . Future work will add additional objective functions and decision variables to the study to optimize additional components in the power electronics system and BESS.

25 ENERGY STORAGE↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Power module packaging with double sided planar interconnection and heat exchangers

A double sided cooled power module package having a single phase leg topology includes two IGBT and two diode semiconductor dies. Each IGBT die is spaced apart from a diode semiconductor die, forming a switch unit. Two switch units are placed in a planar face-up and face-down configuration. A pair of DBC or other insulated metallic substrates is affixed to each side of the planar phase leg semiconductor dies to form a sandwich structure. Attachment layers are disposed on outer surfaces of the substrates and two heat exchangers are affixed to the substrates by rigid bond layers. The heat exchangers, made of copper or aluminum, have passages for carrying coolant. The power package is manufactured in a two-step assembly and heating process where direct bonds are formed for all bond layers by soldering, sintering, solid diffusion bonding or transient liquid diffusion bonding, with a specially designed jig and fixture.

33 ADVANCED PROPULSION SYSTEMS↗

650V SiC Integrated Power Module for Automotive Inverters

The Delphi team, including CREE/Wolfspeed for SiC power devices, with packaging by Delphi supported by Oak Ridge National Laboratory, and guidance from Volvo and other OEMs resulted in a robust, high performance integrated double-side cooled SiC-based Power Module that meets or exceeds the targets identified by DOE in the original FOA. The double-side cooled packages were designed to be scalable for voltages up to 800V and for phase currents up to 500Arms and that can be paralleled for currents up to 90Arms. These modules were confirmed and demonstrated in a traction drive inverter intended for an inverter for a specific OEM vehicle application and showed improved performance as compared to inverter systems with silicon based IGBTs and Diode with losses 70% lower at lower currents and up to 40% lower at peak current levels. This teaming resulted in a WBG integrated power module to be used in an inverter manufactured in Kokomo, Indiana, which will be manufacturable in volume at a cost that will enable reduced vehicle to cost improved performance, particularly by reducing weight and space-claim for the power electronics, as well as improving reliability overall. The targeted use of this developed power module is for a vehicle traction drive to be manufactured in the CY 2021 timeframe. The direct impact of this project will accelerate commercialization of advanced wide bandgap power semiconductor technology for electrified vehicles of all types, increasing their energy efficiency and marketability. In turn, more efficient and more marketable electrified vehicles will have the overall impact of reducing greenhouse gas emissions and other air pollutants, along with reducing our nation’s dependence on foreign energy sources.

33 ADVANCED PROPULSION SYSTEMS↗

A pulse-burst laser system for Thomson scattering on NSTX-U

A pulse-burst laser system has been built for Thomson scattering on NSTX-U, and is currently being integrated into the NSTX-U Thomson scattering diagnostic system. The laser will be operated in three distinct modes. The base mode is continuous 30 Hz rep rate, and is the standard operating mode of the laser. The base mode will be interrupted to produce a "slow burst" (specified 1 kHz rep rate for 50 ms) or a "fast burst" (specified 10 kHz rep rate for 5 ms). The combination of base mode→ interruption→ burst mode is new and has not been implemented on any previous pulse-burst laser system. Laser pulsing is halted for a set period (~ 1 minute) following a burst to allow the YAG rods to cool; this type of operation is called a heat-capacity laser. The laser is Nd:YAG operated at 1064 nm, q-switched to produce ≥ 1.5 J pulses with ~ 20 ns FWHM. It is flashlamp pumped, with dual-rod oscillator (9 mm) and dual-rod amplifier (12 mm). Variable pulsewidth drive of the flashlamps is accomplished by IGBT (insulated gate bipolar transistor) switching of electrolytic capacitor banks. Direct control of the laser Pockels cell drive enables optimal pulse energy extraction. The laser system has demonstrated compliance with all specifications, and is capable of exceeding design specifications by significant margins, e.g., higher rep rates for longer burst periods. Burst operation of this laser system will be used to capture fast time evolution of the electron temperature and density profiles during events such as ELMs, the L-H transition, and various MHD modes.

47 OTHER INSTRUMENTATION↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Disruptive Approach to Electric Vehicle Power Electronics Final Report

This project developed and demonstrated a new power electronics technology for electric vehicle drivetrains, that achieved significant improvements in power density and efficiency over standard drive cycles, relative to the commercial state of the art. In particular, the prototype measured loss and efficiency curves demonstrated a reduction in total loss over the US EPA US06 drive cycle by a factor of four. Similar reductions are observed for urban (UDDS) and highway (HWFET) drive cycles. Further, the project demonstrated a significant reduction in the total film capacitor requirements, by over an order of magnitude; this was achieved through fundamental improvements in converter circuit topologies. These nonincremental technology advances can lead to significant improvements in temperature rise, reliability, cost, and cooling system size and weight. These results were achieved through a new proposed composite converter architecture, and were demonstrated in a boost-type system similar to that employed by Toyota, Ford, and Honda. A 30 kW silicon prototype achieved a US06 average efficiency of 97.5%, which represents a reduction in average loss by a factor of approximately four relative to the 92.5% average efficiency of the commercial state of the art. A silicon carbide prototype achieved similar efficiency, while also achieving power densities of 23 kW/L (volumetric) and 20 kW/kg (gravimetric) in a boost dc-dc system including magnetics and film capacitors. This was achieved with a SiC switching frequency of 240 kHz, which allowed employment of planar magnetics. These power densities are roughly four times better than the commercial state of the art, and significantly exceed the DOE APEEM 2020 goals. In addition to the composite boost system, a SiC inverter was demonstrated at the 800 V 30 kW level. This inverter was demonstrated driving a permanent magnet machine over the US 06 drive cycle. The replacement of 1200 V Si IGBTs with 1200 V SiC MOSFETs led to improvement of CAFE average efficiency from 98.7% to 99.5%, which corresponds to a reduction of average loss by a factor of approximately two. The modular nature of the composite converter architecture opens the possibility of reuse of one or more converter modules during charging operations, providing a path for onboard charging capability at significant power levels while significantly reducing the volume and weight of the added charger module. This project demonstrated an integrated Level II charger whose add-on specific weight was approximately four times better than the DOE PHEV charger 2022 targets.

33 ADVANCED PROPULSION SYSTEMS↗