Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS

Integrate a combined Structures of Lossless Ion Manipulations (SLIM) module that incorporates both constant (not time-varying) field (CF) and oscillatory (time-varying) field (OF) IM separation stages into an Agilent 6560 IM-QTOF mass spectrometer system. Once the SLIM module has been integrated into the Agilent system, its performance will be evaluated using a variety of different samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS - CRADA 413 (Final Report)

Developing new technologies that enhance our abilities to identify molecular signatures is important for the health of the public, the environment, and national security. Deploying these novel technologies requires multiple stages of validation and evaluation. This project focused on evaluating a technology developed at PNNL named Structures for Lossless Ion Manipulations (SLIM) in the context of a commercially available ion mobility mass spectrometer instrument from Agilent Technologies. There is a benefit to integrating the recently developed SLIM module into a real-world instrument platform. Data from the combined instrument will provide new standards for characterizing samples using ion mobility. These standards, related to both the drift time of ions and their resulting collisional cross sections (CCS) will be of value in characterizing samples from both humans and environmental samples, such as soil microbiomes. Because no previous instrument has been designed and implemented to simultaneously analyze the same sample in both constant and oscillating drift fields, the project will provide a new research capability that will support research in a wide variety of applications. The evaluation approach included measuring the resolving power, mass range, sensitivity, and accuracy of two SLIM variations (constant and oscillating fields). Although SLIM performed similarly to the commercial instrument in terms of sensitivity, mass range, and accuracy the resolving power of SLIM far exceeded that of the commercially-available instrument. This validation will provide critically useful data to our commercial partners which they can use to reach informed decisions on the advantages of the SLIM technology such as the outstanding performance and the low cost of manufacturing.

42 ENGINEERING↗

Analysis and Compensation of Tx and Rx IQ Imbalances in Uplink IM-OFDMA Systems

Index modulation-based orthogonal division multiple access (IM-OFDMA) has recently been proposed as a potential technique for future wireless communication systems due to its superior spectral efficiency and error performance over conventional multiple access schemes. However, its performance is still under investigation by researchers in light of a variety of scenarios and assumptions. Following this direction, in this Article, the individual and joint effects of the transmitter (Tx) and receiver (Rx) in-phase and quadrature imbalances (IQI) on the bit-error-rate (BER) performance of the uplink IM-OFDMA scheme are investigated by considering whether each user's RF front-end is identical or not. Moreover, to reduce the detrimental effect of IQI, a preamble-based estimation and compensation method is proposed for IM-OFDMA. Closed-form expressions for the average BER of IM-OFDMA are obtained by considering the physical effect of the Tx and Rx IQI. Also, using Monte Carlo simulations, the derived expressions are verified under different system configurations. Furthermore, analytical and simulation results reveal that Tx and Rx IQI cause an error floor in the BER performance of IM-OFDMA schemes. However, the proposed estimation and compensation method not only reduces the impact of IQI but also leads to a better BER performance compared to the case of no IQI, which mainly refers to the frequency diversity caused by the IQI.

42 ENGINEERING↗

Nanowell-mediated multidimensional separations combining nanoLC with SLIM IM-MS for rapid, high-peak-capacity proteomic analyses

Mass spectrometry (MS)–based analysis of complex biological samples is essential for biomedical research and clinical diagnostics. The separation prior to MS plays a key role in the overall analysis, with separations having larger peak capacities often leading to more identified species and improved confidence in those identifications. High-resolution ion mobility (IM) separations enabled by Structures for Lossless Ion Manipulation (SLIM) can provide extremely rapid, high-resolution separations and are well suited as a second dimension of separation following nanoscale liquid chromatography (nanoLC). However, existing sample handling approaches for offline coupling of separation modes require microliter-fraction volumes and are thus not well suited for analysis of trace biological samples. We have developed a novel nanowell-mediated fractionation system that enables nanoLC-separated samples to be efficiently preconcentrated and directly infused at nanoelectrospray flow rates for downstream analysis. When coupled with SLIM IM-MS, the platform enables rapid and high-peak-capacity multidimensional separations of small biological samples. In this study, peptides eluting from a 100 nL/min nanoLC separation were fractionated into ~?60 nanowells on a microfluidic glass chip using an in-house–developed robotic system. The dried samples on the chip were individually reconstituted and ionized by nanoelectrospray for SLIM IM-MS analysis. Using model peptides for characterization of the nanowell platform, we found that at least 80% of the peptide components of the fractionated samples were recovered from the nanowells, providing up to ~tenfold preconcentration for SLIM IM-MS analysis. The combined LC-SLIM IM separation peak capacities exceeded 3600 with a measurement throughput that is similar to current one-dimensional (1D) LC-MS proteomic analyses.

Dou, Maowei↗

Fundamental Studies of New Ionization Technologies and Insights from IMS-MS

Exceptional ion mobility spectrometry mass spectrometry (IMS-MS) developments by von Helden, Jarrold, and Clemmer provided technology that gives a view of chemical/biological compositions previously not achievable. The ionization method of choice used with IMS-MS has been electrospray ionization (ESI). In this special issue contribution, we focus on fundamentals of heretofore unprecedented means for transferring volatile and nonvolatile compounds into gas-phase ions singly and multiply charged. These newer ionization processes frequently lead to different selectivity relative to ESI and, together with IMS-MS, may provide a more comprehensive view of chemical compositions directly from their original environment such as surfaces, e.g., tissue. Similarities of results using solvent- and matrix-assisted ionization are highlighted, as are differences between ESI and the inlet ionization methods, especially with mixtures such as bacterial extracts. Selectivity using different matrices is discussed, as are results which add to our fundamental knowledge of inlet ionization as well as pose additional avenues for inquiry. IMS-MS provides an opportunity for comparison studies relative to ESI and will prove valuable using the new ionization technologies for direct analyses. Our hypothesis is that some ESI-IMS-MS applications will be replaced by the new ionization processes and by understanding mechanistic aspects to aid enhanced source and method developments this will be hastened. .

74 ATOMIC AND MOLECULAR PHYSICS↗

False alarms and the IMS infrasound network: Understanding the factors influencing the creation of false events

The International Monitoring System (IMS) infrasound network has been designed to acquire the necessary data to detect and locate explosions in the atmosphere with a yield equivalent to 1 kiloton of TNT anywhere on Earth. A major associated challenge is the task of automatically processing data from all IMS infrasound stations to identify possible nuclear tests for subsequent review by analysts. This paper is the first attempt to quantify the false alarm rate (FAR) of the IMS network, and in particular to assess how the FAR is affected by the numbers and distributions of detections at each infrasound station. To ensure that the results are sufficiently general, and not dependent entirely on one detection algorithm, the assessment is based on two detection algorithms that can be thought of as end members in their approach to the trade-off between missed detections and false alarms. The results show that the FAR for events formed at only two arrays is extremely high (ranging from 10’s to 100’s of false events per day across the IMS network, depending on the detector tuning). It is further shown that the FAR for events formed at three or more IMS arrays is driven by ocean-generated waves (microbaroms), despite efforts within both detection algorithms for avoiding these signals, indicating that further research into this issue is merited. Overall, the results highlight the challenge of processing data from a globally sparse network of stations to detect and form events. On the basis of these results, it is shown that further work on understanding signal and noise characteristics is needed before attempting to automatically form events detected at only two arrays on the global network. In particular, more work is required to reduce false alarms caused by the detection of microbarom signals.

47 OTHER INSTRUMENTATION↗

Using STAX data to predict IMS radioxenon concentrations

The noble gas collection and measurement stations in the International Monitoring System (IMS) are heavily influenced by releases from medical isotope production facilities. The ability to reliably model the movement of radioxenon from the points of release to these IMS samplers has improved enough that a routine aspect of the analysis of IMS radioxenon data should be the prediction of the effect of releases from civilian nuclear facilities on the sample concentrations. In this work, predicted concentrations at IMS noble gas systems in Germany and Sweden based on measured releases from Institute for Radioelements (IRE) in Belgium and atmospheric transport modeling for a four-month period are presented and discussed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development of Intelligent Monitoring System (IMS) Modules for the Aquistore CO 2 Storage Project

The monitoring data generated at a CO 2 storage site can quickly result in large amounts of data, often requiring significant labor- and time-intensive efforts to process and analyze before being able to make operational decisions. Implementing an intelligent monitoring system (IMS) can reduce the associated data-processing and analysis costs, which can thereby improve the efficiency of the monitoring process and enable real-time operational decision-making. The Energy & Environmental Research Center (EERC) has completed a 3-year project focused on developing an IMS comprising new workflows, algorithms, and a user interface for the automation and integration of geologic carbon dioxide (CO 2 ) storage site-monitoring and simulation data. The design for the IMS was based on using injection and monitoring data acquired from Aquistore, an operating CO 2 storage project. Managed by the Petroleum Technology Research Centre, the Aquistore Project is injecting CO 2 captured from SaskPower’s coal-fired Boundary Dam Power Station into a deep saline formation for geologic storage. Using data from the Aquistore Project provided a real-world basis to develop an IMS.

47 OTHER INSTRUMENTATION↗

Secrecy Analysis of Uplink IM-OFDMA Systems in the Presence of IQ Imbalance

This article introduces the secrecy analysis of the index modulation-based orthogonal frequency division multiple access (IM-OFDMA) schemes by considering the in-phase and quadrature imbalance (IQI) presence at the users' RF front ends. In particular, by assuming the existence of an eavesdropper, the secrecy performance of the considered uplink multiple-access system is investigated through the strictly positive secrecy capacity and secrecy outage probability, and closed-form expressions are derived for both quantities. Moreover, the secrecy performance is conducted regarding IQI compensation based on a preamble-based estimation method. Further, analysis of the impact of the different parameters of IM-OFDMA, IQI, and estimation method is included via analytical and simulation-based results. In conclusion, the results reveal that IM-OFDMA is more reliable in secrecy performance than OFDMA, regardless of whether IQI is present. Also, IQI compensation can lead to a better secrecy performance compared to the case of no IQI.

42 ENGINEERING↗

Dual-Phase Malicious User Detection Scheme for IM-OFDMA Systems Using IQ Imbalance

Physical-layer security techniques have contributed to the achievement of various security objectives in an efficient and lightweight manner. Thus, these techniques have been widely considered for limited-resource networks such as Internet of Things networks. Among the different security objectives, malicious user detection by exploiting physical-layer parameters has demonstrated efficient performance. In this work, malicious user detection in the recently proposed index modulation-based orthogonal frequency division multiple access (IM-OFDMA) is addressed. The proposed malicious user detection scheme exploits the hardware impairments, especially the in-phase and quadrature imbalance parameters, for both legitimate and malicious users to design a dual-phase efficient detection scheme. The proposed scheme accounts for the special characteristics of IM-OFDMA transmission that are different from other multiple-access techniques. The performance of the proposed scheme was evaluated considering detection probability and false alarm probability performance metrics. Moreover, closed-form expressions of these metrics were derived for both phases and were validated by Monte Carlo simulation results under different configurations of IM-OFDMA systems.

Alaca, Ozgur [ORNL] (ORCID:0000000153713758)↗

Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modification of conventional peak shapes to accurately represent spectral asymmetry: High-Resolution X-ray photoelectron spectra of [C 4 C 1 Pyrr][NTf 2 ] and [C 8 C 1 Im][NTf 2 ] ionic liquids

X-ray photoelectron spectroscopy (XPS) is one of the most widely used techniques for surface characterization. Analysis of XPS data is challenging and requires the analyst to fit the data with synthetic line shapes to reach physically meaningful interpretations. Experimental spectral envelopes, however, are complex and display asymmetric features that are often ignored or attributed to additional chemical components. The high-resolution XPS spectra of [C 4 C 1 Pyrr][NTf 2 ] and [C 8 C 1 Im][NTf 2 ] all exhibit a degree of asymmetry which is systematically observed at the higher binding energy side of photoemission envelopes. Here, we present the development of a refined fitting procedure for XPS spectra of these ionic liquid-based systems which include (a) Shirley background offset necessary to account for the insulator-like region and (b) spectral asymmetry in C 1s and N 1s regions. Further, Shirley and trapezoid components are applied to compensate for inelastic scattering taking place during electron transitions as high as 7.8 eV above the start of the fitting region in C 1s high-resolution spectrum. To demonstrate the fitness of this model, we present an analysis of a 2:1 mixture of [C 4 C 1 Pyrr][NTf 2 ]: [C 8 C 1 Im][NTf 2 ].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

IMS observations of infrasound and acoustic-gravity waves produced by the January 2022 volcanic eruption of Hunga, Tonga: A global analysis

The 15 January 2022 Hunga, Tonga, volcano's explosive eruption produced the most powerful blast recorded in the last century, with an estimated equivalent TNT yield of 100–200 megatons. The blast energy was propagated through the atmosphere as various wave types. The most prominent wave was a long-period (>2000 s) surface-guided Lamb wave with energy comparable to that of the 1883 Krakatoa Lamb wave; both were clearly observed by pressure sensors (barometers) worldwide. Internal gravity, acoustic-gravity, and infrasound waves were captured in great detail by the entire infrasound component of the International Monitoring System (IMS). For instance, infrasound waves (<300 s period) were seen to circumnavigate Earth up to eight times. Atmospheric waves captured by the IMS infrasound network and selected barometers near the source provide insight on Earth's impulse response at planetary scales.

58 GEOSCIENCES↗

LC-IMS-MS Feature Finder

The LC-IMS-MS Feature Finder finds LC-IMS-MS features and conformers using deisotoped features from DeconTools.

Gibbons, Bryson↗

Screening IMS Seismic Detections using Dynamic Correlation Processor: Progress report for 2020

LLNL completed the FY20 workplan entailing application of the Dynamic Correlation Processor (DCP) to International Monitoring System (IMS) primary seismic data in 2019 and 2020. The effective analysis period was curtailed to January 1 through November 12, 2019 due to a data compression change that rendered later data unusable. Fixing the data compression error is a priority for our data source, and we plan to extend the period of data analysis when the fix is implemented. We found that the percentage overlap between detections generated by the International Data Centre (IDC) DFX software and detections generated by DCP varied widely by station. Overlap is 30-40% at some stations, suggesting that a large percentage of DFX detections could be screened (removed) from the detection-event association algorithm. However, detection overlap was much lower, a few percent, at many stations and the percentage overlap was low at stations known to have many mines and other local sources of seismicity. Unexpectedly low detection overlap at many stations prompted us to examine results for the ARCES station in detail. There is considerable mine activity near ARCES, but our initial FY20 analysis found only ~2% DCP/DFX detection overlap. Differences in the pre-processing (e.g. beam recipes) used by DCP and DFX appear to be the cause of low detection overlap at ARCES. DCP uses wideband filters to improve detector robustness and the IDC uses narrow-band pre-filtering to improve sensitivity. After reprocessing ARCES using the IDC beam recipe, DCP/DFX overlap increased to ~74%. This result shows that we must reprocess the IMS network using the IDC station-specific beam recipes if we are to effectively screen DFX detections and improve automatic event building performance at the IDC.

58 GEOSCIENCES↗

Evaluation of the PhaseNet Model Applied to the IMS Seismic Network

Producing a complete and accurate set of signal detections is essential for automatically building and characterizing seismic events of interest for nuclear explosion monitoring. Signal detection algorithms have been an area of research for decades, but still produce large quantities of false detections and misidentify real signals that must be detected to produce a complete global catalog of events of interest. Deep learning methods have shown promising capabilities in effectively characterizing seismic signals for complex tasks such as identifying phase arrival times. We use the PhaseNet model, a UNet-based Neural Network, trained on local distance data from northern California to predict seismic arrivals on data from the International Monitoring System (IMS) global network. We use an analyst-curated bulletin generated from this data set to compare the performance of PhaseNet to that of the Short-Term Average/Long-Term Average (STA/LTA) algorithm. We find that PhaseNet has the potential of outperforming traditional processing methods and recommend the training of a new model with the IMS data to achieve optimal performance.

58 GEOSCIENCES↗

Tidally Excited Modes and δ Scuti Pulsations in the Eclipsing Triple Star IM Persei

IM Per is a triple star system whose eclipsing pair masses and radii are accurate to within 1%. The Transiting Exoplanet Survey Satellite (TESS) light curve of the program target exhibits partial eclipses and multiple oscillations with millimagnitude-level amplitudes. It is found that the oscillations affect eclipse timing measurements. Binary modeling of the high-quality TESS data indicates that the eclipsing components of the triple system are twin dwarfs with parameters of M {sub 2}/M {sub 1} = 0.995, R {sub 2}/R {sub 1} = 0.901, and Δ(T{sub eff,1}–T{sub eff,2}) = 12 K in an eccentric (e = 0.049), detached configuration. The third light of l {sub 3} = 0.054 may mostly come from a G-type tertiary companion. Our predicted parallax of 1.52 ± 0.09 mas is concurrent with the Gaia measurement of 1.52 ± 0.05 mas. Multifrequency analysis of the outside-eclipse residuals reveals 22 significant pulsation signals: 4 in the gravity-mode region (0.03−2.22 day{sup −1}) and 18 in the pressure-mode region (9.19−25.12 day{sup −1}). Of the low frequencies, f {sub 11} and f {sub 14} are orbital harmonics that can be identified as tidally excited modes. The pulsation periods and constants for the high frequencies, and the position in the Cepheid instability strip demonstrate that the pulsating component of IM Per is a δ Sct variable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗