Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Cyclable Variable Path Length Multilevel Structures for Lossless Ion Manipulations (SLIM) Platform for Enhanced Ion Mobility Separations

Ion mobility-mass spectrometry (IMS-MS) is increasingly used to analyze complex samples and provide structural information of unknown compounds. As the complexity of samples increases, there is a need to improve the resolution of IMS-MS instruments to increase the rate of molecular identification. In this work, we evaluated a cyclable and variable-pathlength multilevel Structures for Lossless Ion Manipulations (SLIM) platform to achieve a higher resolving power than previously possible. This new multilevel SLIM platform has eight separation levels connected by ion escalators and a path length of ~88 meters (~11 meters per level). Our new multilevel SLIM can also be operated in an ‘ion cycling’ mode where a set of return ion escalators transport ions from the eighth back to the first level, allowing even longer path lengths (and higher IMS resolution). The platform has been improved to enhance the ion transmission and IMS separation quality by reducing the spacing between SLIM boards as well as board thickness, reducing the ions’ escalator residence time. Compared to the previous generation, the new multilevel SLIM demonstrated a better transmission for a set of phosphazene ions, especially for the low-mobility ions. The new multilevel SLIM achieved better resolving powers than our previous 4-level SLIM. The collision cross-section-based resolving power of the SLIM platform was tested using a pair of singly-charged reverse sequence peptides (SDGRG 1+ , GRGDS 1+ ). We achieved 1100 resolving power using 88 meters of path length (i.e., 8 levels) and 1400 following an additional pass through the eight levels (i.e., 16 levels or 173.5 m). The multilevel SLIM was further evaluated to demonstrate the enhanced separation for a positively and negatively charged brain total lipid extract sample. Finally, the new multilevel SLIM enables much higher resolving powers for a wide range of ion mobilities, improved transmission for low-mobility ions, and the ability to perform even higher resolving power for ions of interest.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Resolving Lipid Structures for Threat-Agnostic Signatures

Development of threat-agnostic biosignatures is critical for the detection of and response to biological threats that go beyond the historical list-based approach. Lipids are a class of structurally diverse biomolecules that hold great promise as relevant threat-agnostic biosignatures, yet the fundamental challenge of resolving and decoding structural differences among lipids remains an obstacle in the pursuit of signature development. Structural analysis of complex lipids remains stymied due to spectral complexity and the inability to resolve low abundance lipids. To address these challenges, we integrated ozonolysis with ion mobility mass spectrometry (IMS-MS) analysis to determine the structural information for complex lipid species and (2) reduced lipid sample complexity prior to introduction into the IMS-MS using normal phase high pressure liquid chromatography (HPLC) to enable the ozonolysis of low abundance lipids. We applied these new capabilities to define the lipid structures in antimicrobial resistant (AMR) and antimicrobial susceptible (AMS) biothreat organism Yersinia pestis and cells infected with Severe Acute Respiratory Syndrome coronavirus 2 (SARS-CoV-2) variants.

59 BASIC BIOLOGICAL SCIENCES↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Structure for Lossless Ion Manipulations (SLIM) High Charge Capacity Array of Traps

Enhancing the sensitivity of low abundance ions in a complex mixture without sacrificing experiment throughput is highly desirable. This work demonstrates a way to greatly improve the sensitivity of ion mobility (IM) selected ions by accumulating them in an array of high-capacity ion traps located inside a novel structures for lossless ion manipulations ion mobility spectrometer (SLIM-IMS) module. The array of ion traps used in this work consisted of seven independently controllable traps. Each trap was 386 mm long and possessed a charge capacity of ~4.5×10 8 charges, with a linear range extending to ~2.5×10 8 charges. Each ion trap could be used to extract a peak (or ions over a mobility range) from an ion mobility separation based on arrival time. Ions could be stored without losses for long times (>100 s) and then released all at once or one trap at a time. It was possible to accumulate large ion populations by extracting and storing ions over repeated IM separations. We report enrichment of up to seven individual ion distributions could be performed using the seven independently controllable ion traps. Additionally, the ion trapping process effectively compressed ion populations into narrow peaks, which provides a greatly improved basis for subsequent ion manipulations. The array of high charge-capacity ion traps provides a flexible addition to SLIM and a powerful tool for IMS-MS applications requiring high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Software Tools for Lipid Identification from Ion Mobility Spectrometry–Mass Spectrometry Lipidomics Data

The unambiguous identification of lipids is a critical component of lipidomics studies and greatly impacts the interpretation and significance of analyses as well as the ultimate biological understandings derived from measurements. The level of structural detail that is available for lipid identifications is largely determined by the analytical platform being used. Mass spectrometry (MS) coupled with liquid chromatography (LC) is the predominant combination of analytical techniques used for lipidomics studies, and these methods can provide fairly detailed lipid identification. More recently, ion mobility spectrometry (IMS) has begun to see greater adoption in lipidomics studies thanks to the additional dimension of separation that it provides and the added structural information that can support lipid identification. At present, relatively few software tools are available for IMS-MS lipidomics data analysis, which reflects the still limited adoption of IMS as well as the limited software support. This fact is even more pronounced for isomer identifications, such as the determination of double bond positions or integration with MS-based imaging. In this review, we survey the landscape of software tools that are available for the analysis of IMS-MS-based lipidomics data and we evaluate lipid identifications produced by these tools using open-access data sourced from the peer-reviewed lipidomics literature.

59 BASIC BIOLOGICAL SCIENCES↗

Refining PeakDecoder Version 2

Novel computational tools for processing multidimensional mass spectrometry (MS) data are necessary to enable deeper and automated detection and quantification of metabolites in complex backgrounds. Multidimensional MS data includes measurements from liquid chromatography (LC) and ion mobility spectrometry (IM) separations, and precursor and fragment ion spectra collected in data-independent acquisition (DIA) mode. PeakDecoder is an artificial intelligence (AI)-based software that enables automated interpretation of this kind of data to identify and quantify individual metabolites in complex mixtures. The goal of this project was to improve and re-implement PeakDecoder in a better suited programming language to enable its commercialization.

97 MATHEMATICS AND COMPUTING↗