Nuclear Data Sheets for A = 116
This evaluation for A = 116 updates one by J. Blachot, (2001Bl07) published in Nuclear Data Sheets 92, 455 (2001)
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This evaluation for A = 116 updates one by J. Blachot, (2001Bl07) published in Nuclear Data Sheets 92, 455 (2001)
It is studied how the threshold current of InGaAs/AlGaAs quantum-well injection heterolasers emitting near the wavelength λ = 0.7 μm changes under irradiation by thermal neutrons. It is found that the threshold pump current decreases at small doses (10{sup -2} neutron cm{sup -2}), while doses exceeding 6 × 10{sup 7} neutron cm{sup -2} cause an increase in this current and degradation of the structure. It is found that the main reasons for an increase in the threshold current at high irradiation doses are the nuclear reactions of the {sub 49}In{sup 115} (n, γ) → {sub 49}In{sup 116} type and the β-decay of the {sub 49}In{sup 116} isotope, which results in the appearance of {sub 50}Sn{sup 116} atoms. (lasers)
During the MAESTRO program, carried out between 2011 and 2014 in MINERVE zero power reactor, common Gen-II and Gen-III light water reactor materials were irradiated. For some of these materials, the decay of their activation products was also measured by γ spectrometry. Initially devoted to the measurement of the integral capture cross section by activation and reactivity-oscillation method, these results can also provide useful information on decay data of various radionuclides. This approach of this experiment led to a common roadmap shared by the Experimental Physics Section and the Henri Becquerel National Laboratory to improve decay data in nuclear data libraries. Results discussed in this paper concern the relative emission intensities of the main γ rays of {sup 116m}In. Six irradiations of samples with various physical forms of {sup nat}In were carried out. Measurements were analyzed using decay data from several evaluations and it is shown that γ ray activities are not consistent. Analyses were carried out to provide new relative γ emission intensities from these measurements. The {sup 116m}In half-life has also been measured and shows a good agreement with existing values. Finally, an overview of the foreseen results on additional decay data from the MAESTRO program is given. (authors)
The experimental study on the thorium-loaded accelerator-driven system (ADS) is conducted in the Kyoto Univ. Critical Assembly (KUCA). The experiments are carried out in both the critical and subcritical states for attaining the reaction rates of the thorium capture and fission reactions. In the critical system, the thorium plate irradiation experiment is carried out for the thorium capture and fission reactions. From the results of the measurements, the thorium fission reactions are obtained apparently in the critical system, and the C/E values of reaction rates show the accuracy of relative difference of about 30%. In the ADS experiments with 14 MeV neutrons and 100 MeV protons, the subcritical experiments are carried out in the thorium-loaded cores to obtain the capture reaction rates through the measurements of {sup 115}In(n, {gamma}){sup 116m}In reactions. The results of the experiments reveal the difference between the reaction rate distributions for the change in not only the neutron spectrum but also the external neutron source. The comparison between the measured and calculated reaction rate distributions demonstrates a discrepancy of the accuracy of reaction rate analyses of thorium capture reactions through the thorium-loaded ADS experiments with 14 MeV neutrons. Hereafter, kinetic experiments are planned to be carried out to deduce the delayed neutron decay constants and subcriticality using the pulsed neutron method. (authors)
The presence of substantial systematic discrepancies between the results of different experiments devoted to determining cross sections for partial photoneutron reactions-first of all, ({gamma}, n), ({gamma}, 2n), and ({gamma}, 3n) reactions-is a strong motivation for studying the reliability and authenticity of these data and for developing methods for taking into account and removing the discrepancies in question. In order to solve the first problem, we introduce objective absolute criteria involving transitional photoneutron-multiplicity functions F{sub 1}, F{sub 2}, F{sub 3}, Horizontal-Ellipsis ; by definition, their values cannot exceed 1.0, 0.5, 0.33, Horizontal-Ellipsis , respectively. With the aim of solving the second problem, we propose a new experimental-theoretical approach. In this approach, reaction cross sections are evaluated by simultaneously employing experimental data on the cross section for the total photoneutron yield, {sigma}{sup expt}({gamma}, xn) = {sigma}{sup expt}({gamma}, n) + 2{sigma}{sup expt}({gamma}, 2n) + 3{sigma}{sup expt}({gamma}, 3n) + Horizontal-Ellipsis , which are free from drawbacks plaguing experimental methods for sorting neutrons in multiplicity, and the results obtained by calculating the functions F{sub theor}{sup 1}, F{sub theor}{sup 2}, F{sub theor}{sup 3}, Horizontal-Ellipsis on the basis of the modern model of photonuclear reactions. The reliability and authenticity of data on the cross sections for ({gamma}, n), ({gamma}, 2n), and ({gamma}, 3n) partial reactions-{sigma}{sup eval}({gamma}, in) = F{sub i}{sup theor}{sigma}{sup expt}({gamma}, xn)-were evaluated for the {sup 90}Zr, {sup 115}In, {sup 112,114,116,117,118,119,120,122,124}Sn, {sup 159}Tb, and {sup 197}Au nuclei.
Lithium indium diselenide, 6 LiInSe 2 or LISe, is a newly developed neutron detection material that shows both semiconducting and scintillating properties. The 24% atomic density of 6 Li yields a thermal neutron mean free path of only 920 μm. This paper reports on the performance of LISe crystals in scintillation mode for its potential use as a converter screen for thermal/cold neutron imaging. The spatial resolution of LISe, determined using a 10% value of the Modulation Transfer Function (MTF), was found to not scale linearly with thickness. Crystals having a thickness of 450 μm or larger resulted in an average spatial resolution of 67 μm, and the thinner crystals exhibited an increase in spatial resolution down to the Nyquist frequency of the CCD. The highest measured spatial resolution of 198 μm thick LISe (27 μm) outperforms a commercial 50 μm thick ZnS(Cu): 6 LiF scintillation screen (100 μm) by more than a factor of three. For the thicknesses considered in this study, it has been found that the light yield of LISe did not scale with its thickness, suggesting the need for optimizing the synthesis to enhance the scintillation mechanism. Absorption measurements indicate that the 6 Li concentration is uniform throughout the samples and its absorption efficiency as a function of thickness follows general nuclear theory, indicating that the variation in apparent brightness is likely due to a combination of particle escape, light transport, and activation of the scintillation mechanisms. As a result, the presence of 115 In and its long-lived 116 In activation product did not result in ghosting (memory of past neutron exposure), demonstrating potential for using LISe for imaging transient systems.
In this work, the DC and RF performance of a 20 nm gate length novel metal oxide semiconductor high electron mobility transistor (MOSHEMT) on Silicon substrate is studied using Sentaurus TCAD tool. The proposed MOSHEMT device features a novel T-gate structure, heavily doped In{sub 0.52}Ga{sub 0.48}As source/drain regions, delta doped planes on both sides of the In{sub 0.75}Ga{sub 0.25}As/InAs/In{sub 0.75}Ga{sub 0.25}As composite channel, a multi layer cap and a very thin layer of HfO{sub 2} as gate dielectric. The TCAD simulation results obtained at room temperature using hydrodynamic carrier transport model indicates that the 20 nm gate length proposed MOSHEMT device is capable of providing a peak drain current of 2450 mA/mm at V{sub DS} = 0.6 V and the peak transconductance obtained for the proposed device is 2900 mS/mm. The f{sub T} and f{sub max} obtained for the L{sub g} = 20 nm proposed MOSHEMT on Silicon substrate are 372 and 480 GHz respectively. At 300 K, the measured Hall mobility of the electrons in the quantum well channel is 9600 cm{sup 2}/(V s). The on state resistance (R{sub ON}) obtained for the L{sub g} = 20 nm proposed device is 116 Ohm μm. These devices are undoubtedly, the most suitable candidates for future sub millimetre wave applications.