New Hybrid Model for Evaluating the Frequency-Dependent Leakage Inductance of a Variable Inductance Transformer (VIT)

Skin and proximity effects can cause a significant drop in the effective leakage inductance of a transformer when the operating frequency is increased. Although the magnetic image method-based double-2-D model can calculate the lowfrequency leakage inductance with sufficient accuracy, it is inherently a frequency-independent model. While Dowell’s 1-D model uses frequency-dependent relations to account for both skin and proximity effects, its accuracy is severely affected by the assumed winding geometry. In this paper, a hybrid model is proposed that uses superposition to combine a modified Dowell’s model with the double-2-D model. The proposed model is investigated on a variable inductance transformer (VIT)—a partially-filled transformer whose leakage inductance can be varied by moving one of the windings mechanically. The frequency-dependent leakage inductances of the VIT evaluated using the hybrid model are in excellent agreement with the corresponding finite element method (FEM) simulated and experimentally measured values, thereby validating the proposed hybrid model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Transformer with Variable Leakage and Magnetizing Inductances

This paper introduces the concept of a novel variable inductance transformer (VIT) whose leakage and magnetizing inductances can be varied dynamically and independently to aid the advancement of research in isolated power electronic converters. In this transformer, the leakage inductance can be varied by varying the length of overlap between the primary and secondary windings, while the magnetizing inductance can be varied by varying the air gap between the core legs. Individual controls for the two inductances ensure that one can be varied independent of the other, as needed to satisfy different power conversion objectives. In this paper, the analytical models of the variable leakage and magnetizing inductances are presented. Analytical results are compared with those obtained from Finite Element Method (FEM) and an experimental prototype of a VIT. Analytical solutions of the variable leakage inductance present an error of less than 2.35 % when compared to FEM solutions, while the analytical solutions of the variable magnetizing inductance present a maximum error of 1.82 % when compared to experimental measurements.

image method, leakage inductance, magnetizing indu↗

Transformer Leakage Inductance Design Methodology

The leakage inductance exhibited by a transformer depends on its winding geometry, which generally involves the selection of several key design parameters in addition to the winding structure and the interleaving configuration. With few resources explaining the effects of these design choices on the observed leakage inductance, numerous trial-and-error iterations become necessary to realize the desired leakage inductance. This paper explores more than a hundred winding geometries feasible in a 2-winding transformer comprising the same magnetic core, number of turns, and wire gauge, and finds the leakage inductance for each unique design using 2-D finite element method (FEM) simulations in association with the semi-analytical double- 2-D model. These leakage inductances are plotted and further analyzed to understand the effects of different design parameters on the effective leakage inductance. The results presented herein and the conclusions drawn from this research can serve as a valuable resource for future design practitioners from both industry and academia.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Kinetic Inductance Ammeter with Coplanar Waveguide Input Structure for Magnetic Flux Focusing

We propose a multiplexible kinetic inductance ammeter, which uses a high-quality-factor, superconducting, lumped-element, kinetic inductance resonator as a current sensor, a short, superconducting coplanar waveguide (CPW) for current input, and a CPW transmission line for the sensor readout. The resonator consists of an interdigitated capacitor and a superconducting loop that inductively couples to the input CPW. Current running through the central line of the input CPW generates magnetic fields which are focused into the gaps of the input CPW. These magnetic fields can be measured collectively as the magnetic flux through the superconducting loop. The kinetic inductance of the superconducting loop depends on the screening current for the magnetic flux, so the input current is converted to a change in the frequency of the resonator. We analyze the response and noise of a kinetic inductance ammeter with a high-resistivity NbN loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Controlling hollow relativistic electron beam orbits with an inductive current divider

A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I{sub 2}-I{sub 1}), while the average force on the envelope (the beam width) is proportional to the beam current I{sub b} = (I{sub 2} + I{sub 1}). The values of I{sub 1} and I{sub 2} depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. Solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle-in-cell simulations of electron beam control using an inductive current divider

Kinetic, time-dependent, electromagnetic, particle-in-cell simulations of the inductive current divider are presented. The inductive current divider is a passive method for controlling the trajectory of an intense, hollow electron beam using a vacuum structure that inductively splits the beam’s return current. The current divider concept was proposed and studied theoretically in a previous publication [Phys. Plasmas 22, 023107 (2015)] A central post carries a portion of the return current (I 1 ) while the outer conductor carries the remainder (I 2 ) with the injected beam current given by I b =I 1 +I 2 . The simulations are in agreement with the theory which predicts that the total force on the beam trajectory is proportional to (I 2 -I 1 ) and the force on the beam envelope is proportional to I b . For a fixed central post, the beam trajectory is controlled by varying the outer conductor radius which changes the inductance in the return-current path. The simulations show that the beam emittance is approximately constant as the beam propagates through the current divider to the target. As a result, independent control over both the current density and the beam angle at the target is possible by choosing the appropriate return-current geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Nonlinear Regression Method for Composite Protection Modeling of Induction Motor Loads

Protection equipment are used to prevent damages to induction motor loads by isolating those from the power network in the event of severe faults. Modeling the response of induction motor loads and their protection is vital for power system planning and operation, especially in understanding system's response moments after a fault has occurred. This article proposes an optimization based framework to generate composite protection models for commercial building motor loads. Introducing a mathematical abstraction, the task of finding a suitable (simplified) model of the composite protection scheme is formulated as a nonlinear regression problem. Numerical examples are provided to illustrate the application of the framework.

Kundu, Soumya↗

Wireless current sensing by near field induction from a spin transfer torque nano-oscillator

We demonstrate that spin transfer torque nano-oscillators (STNO) can act as wireless sensors for local current. The STNO acts as a transducer that converts weak direct currents into microwave field oscillations that we detect using an inductive coil. We detect direct currents in the range of 300–700 μA and report them wirelessly to a receiving induction coil at distances exceeding 6.5 mm. This current sensor could find application in chemical and biological sensing and industrial inspection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of non-equilibrium phenomena in inductively coupled plasma generators

This article addresses the modeling of non-equilibrium phenomena in inductively coupled plasma discharges. In the proposed computational model, the electromagnetic induction equation is solved together with the set of Navier-Stokes equations in order to compute the electromagnetic and flow fields, accounting for their mutual interaction. Semi-classical statistical thermodynamics is used to determine the plasma thermodynamic properties, while transport properties are obtained from kinetic principles, with the method of Chapman and Enskog. Particle ambipolar diffusive fluxes are found by solving the Stefan-Maxwell equations with a simple iterative method. Two physico-mathematical formulations are used to model the chemical reaction processes: (1) A Local Thermodynamics Equilibrium (LTE) formulation and (2) a thermo-chemical non-equilibrium (TCNEQ) formulation. In the TCNEQ model, thermal non-equilibrium between the translational energy mode of the gas and the vibrational energy mode of individual molecules is accounted for. The electronic states of the chemical species are assumed in equilibrium with the vibrational temperature, whereas the rotational energy mode is assumed to be equilibrated with translation. Three different physical models are used to account for the coupling of chemistry and energy transfer processes. Numerical simulations obtained with the LTE and TCNEQ formulations are used to characterize the extent of non-equilibrium of the flow inside the Plasmatron facility at the von Karman Institute. Each model was tested using different kinetic mechanisms to assess the sensitivity of the results to variations in the reaction parameters. A comparison of temperatures and composition profiles at the outlet of the torch demonstrates that the flow is in non-equilibrium for operating conditions characterized by pressures below 30 000 Pa, frequency 0.37 MHz, input power 80 kW, and mass flow 8 g/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of axial‐induction‐based wind plant control using an engineering and a high‐order wind plant model

Abstract Wind turbines are typically operated to maximize their performance without considering the impact of wake effects on nearby turbines. Wind plant control concepts aim to increase overall wind plant performance by coordinating the operation of the turbines. This paper focuses on axial‐induction‐based wind plant control techniques, in which the generator torque or blade pitch degrees of freedom of the wind turbines are adjusted. The paper addresses discrepancies between a high‐order wind plant model and an engineering wind plant model. Changes in the engineering model are proposed to better capture the effects of axial‐induction‐based control shown in the high‐order model. Copyright © 2015 John Wiley & Sons, Ltd.

Annoni, Jennifer↗

Induction time of a polymorphic transformation

When a solution is supersaturated with respect to multiple polymorphs, the polymorph with the lowest nucleation barrier will form first. If this is a metastable polymorph, it will persist until the induction of nuclei of a lower free-energy phase, marking the onset of a polymorphic transformation. Induction of a more stable polymorph can occur under two conditions: a.) during steady-state nucleation, or b.) after complete crystal growth of the metastable phase. Using the theory of competing stochastic processes, we derive the rare probability of forming a higher-barrier, more-stable polymorph during steady-state nucleation, and use this to explain variations in crystallization products between repeat experiments, which may underlie the phenomenon of "Disappearing Polymorphs". We also derive the induction time of a stable phase from a solution equilibrated with a metastable phase, and show that once the stable phase nucleates, bulk metastable crystals will spontaneously ripen onto nanoscale nuclei or seeds of a more stable phase, thermodynamically driving dissolution-reprecipitation processes. Existing strategies to prolong or shorten the lifetimes of transient metastable phases are reviewed and interpreted within the context of polymorphic induction. Finally, the analyses in this work are conducted from classical nucleation and crystal growth theories, suggesting that paradigms shifts to 'non-classical' nucleation theories may not be necessary to rationalize multistage crystallization.

36 MATERIALS SCIENCE↗

Simulation of injector dynamics during steady inductive helicity injection current drive in the HIT-SI experiment

We present simulations of inductive helicity injection in the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) device that treats the entire plasma volume in a single dynamic MHD model. A new fully 3D numerical tool, the PSI-center TETrahedral mesh code, was developed that provides the geometric flexibility required for this investigation. Implementation of a zero-β Hall MHD model using PSI-TET will be presented including formulation of a new self-consistent magnetic boundary condition for the wall of the HIT-SI device. Results from simulations of HIT-SI are presented focusing on injector dynamics that are investigated numerically for the first time. Asymmetries in the plasma loading between the two helicity injectors and progression of field reversal in each injector are observed. Analysis indicates cross-coupling between injectors through confinement volume structures. Injector impedance is found to scale with toroidal current at fixed density, consistent with experimental observation. Comparison to experimental data with an injector drive frequency of 14.5 kHz shows good agreement with magnetic diagnostics. Global mode structures from Bi-Orthogonal decomposition agree well with experimental data for the first four modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet

Purpose: Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. Methods: In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. Results: The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. Conclusions: The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of Tantalum Content During Vacuum Induction Melting and Electroslag Remelting of a Novel Martensitic Steel

The need for materials with superior thermal and mechanical properties while mitigating cost increases interest in new complex alloy compositions which brings challenges to manufacturing processes. In this investigation, vacuum induction melting (VIM) and electroslag remelting (ESR) of a novel tantalum (Ta)-containing martensitic steel was performed using standard industry practices at a laboratory scale. A 25 pct loss of Ta was measured from the VIM electrode to the ESR ingot using X-ray fluorescence. Several tools were used for broad characterization of the ingots, including LECO for chemistry analysis, scanning electron microscopy, and electron probe microanalysis for observation of the precipitate and inclusion phases post-VIM and post-ESR as well as computational modeling of the ESR process for the calculation of macrosegregation and inclusion travel. It was found that a significant amount of Ta{sub 2}O{sub 5} inclusions formed during VIM and were transferred to the slag during ESR. While ESR was particularly successful at decreasing the number density of inclusions by 95 pct, additional efforts are needed with regard to vacuum leak rate and purity of stock material when melting novel advanced steels.

36 MATERIALS SCIENCE↗

Cold crucible induction melter studies for making glass ceramic waste forms: A feasibility assessment

Glass ceramics are being developed to immobilize fission products, separated from used nuclear fuel by aqueous reprocessing, into a stable waste form suitable for disposal in a geological repository. This work documents the glass ceramic formulation at bench scale and for a scaled melter test performed in a pilot-scale (approximately 1/4 scale) cold crucible induction melter (CCIM). Melt viscosity, electrical conductivity, and crystallization behavior upon cooling were measured on a small set of compositions to select a formulation for melter testing. Property measurements also identified a temperature range for melter operation and cooling profiles necessary to crystallize the targeted phases in the waste form. Bench scale and melter run results successfully demonstrate the processability of the glass ceramic using the CCIM melter technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast wave direct electron heating in advanced inductive and ITER baseline scenario discharges in DIII-D

Fast Wave (FW) heating and electron cyclotron heating (ECH) are used in the DIII-D tokamak to study plasmas with low applied torque and dominant electron heating characteristic of burning plasmas. FW heating via direct electron damping has reached the 2.5 MW level in high performance ELMy H-mode plasmas. In Advanced Inductive (AI) plasmas, core FW heating was found to be comparable to that of ECH, consistent with the excellent first-pass absorption of FWs predicted by ray-tracing models at high electron beta. FW heating at the ∼2 MW level to ELMy H-mode discharges in the ITER Baseline Scenario (IBS) showed unexpectedly strong absorption of FW power by injected neutral beam (NB) ions, indicated by significant enhancement of the D-D neutron rate, while the intended absorption on core electrons appeared rather weak. The AI and IBS discharges are compared in an effort to identify the causes of the different response to FWs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron energy distributions and electron impact source functions in Ar/N{sub 2} inductively coupled plasmas using pulsed power

In plasma materials processing, such as plasma etching, control of the time-averaged electron energy distributions (EEDs) in the plasma allows for control of the time-averaged electron impact source functions of reactive species in the plasma and their fluxes to surfaces. One potential method for refining the control of EEDs is through the use of pulsed power. Inductively coupled plasmas (ICPs) are attractive for using pulsed power in this manner because the EEDs are dominantly controlled by the ICP power as opposed to the bias power applied to the substrate. In this paper, we discuss results from a computational investigation of EEDs and electron impact source functions in low pressure (5–50 mTorr) ICPs sustained in Ar/N{sub 2} for various duty cycles. We find there is an ability to control EEDs, and thus source functions, by pulsing the ICP power, with the greatest variability of the EEDs located within the skin depth of the electromagnetic field. The transit time of hot electrons produced in the skin depth at the onset of pulse power produces a delay in the response of the EEDs as a function of distance from the coils. The choice of ICP pressure has a large impact on the dynamics of the EEDs, whereas duty cycle has a small influence on time-averaged EEDs and source functions.