Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUSTRIAL RADIOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Safety and security of radioactive sources in industrial radiography in Bangladesh

Malicious use of radioactive sources can involve dispersal of that material through an explosive device. There has been recognition of the threat posed by the potential malicious misuse of NDT radioactive source by terrorists. The dispersal of radioactive material using conventional explosives, referred to as a 'dirty bomb', could create considerable panic, disruption and area access denial in an urban environment. However, as it is still a relatively new topic among regulators, users, and transport and storage operators worldwide, international assistance and cooperation in developing the necessary regulatory and security infrastructure is required. The most important action in reducing the risk of radiological terrorism is to increase the security of radioactive sources. This paper presents safety and security considerations for the transport and site storage of the industrial radiography sources as per national regulations entitled 'Nuclear Safety and Radiation Control Rules-1997'.The main emphasis was put on the stages of some safety and security actions in order to prevent theft, sabotage or other malicious acts during the transport of the packages. As a conclusion it must be mentioned that both safety and security considerations are very important aspects that must be taking in account for the transport and site storage of radioactive sources used in the practice of industrial radiography. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

X-ray digital industrial radiography (DIR) for local liquid velocity (V{sub LL}) measurement in trickle bed reactors (TBRs): Validation of the technique

Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (V{sub LL}) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the V{sub LL} within TBRs.

42 ENGINEERING↗

General Overview of Mobile Sources Used for Well Logging and Industrial Radiography Applications

Mobile sources is a term most commonly used to describe radioactive sources that are used in applications requiring frequent transportation. Such radioactive sources are in common use world-wide where typical applications include radiographic non-destructive evaluation (NDE) and oil and gas well logging, among others requiring lesser amounts of radioactivity. This report provides a general overview of mobile sources used for well logging and industrial radiography applications including radionuclides used, equipment, and alternative technologies. Information presented here has been extracted from a larger study on common mobile radiation sources and their use.

47 OTHER INSTRUMENTATION↗

Defect Detection of Industrial Radiography Images of Ammonia Pipes by a Sparse Coding Model

Pipeline transportation systems for liquid anhydrous ammonia require periodic inspections for pipe defects. Defects such as crack-like flaws, including those due to stress corrosion and fatigue crack growth and fatigue of welded joints, can be tested by in situ radiography testing (RT). It is required that the detection technique should reveal the defect region without any significant distortion. Imaging noise such as that due to radiation scattering reduces contrast over the whole or part of the image, causing a reduction in image quality. Various image processing methods can be utilized to improve the outcome of RT of pipes. The sparse coding model is a powerful contrast improvement algorithm, but it tends to eliminate imaging details, passing them off as noise. We present a novel implementation of the sparse coding model based on a probabilistic interpretation to improve defect detection in ammonia pipelines radiography images. The performance of this procedure was evaluated in radiographic images of defect and corrosion regions for different pipe types. For ammonia pipes, the technique was found to offer a significant improvement in defect detection while preserving imaging details.

42 ENGINEERING↗

Shortened processing time technique for color industrial radiography

Improved processing method reduces time required to generate a color radiograph. Prior to, or after exposure to penetrating radiation, the emulsion side of the film is flashed to a colored light which produces the hue changes in the processed radiograph. Agitation of the film during processing assures uniformity of results.

Lapinski, N. P.↗

Scatter Signal Elimination by Localized Primary Modulation in Industrial Computed Radiography

In industrial computed radiography, same as the other projection imaging systems, quantitative integrated information of total beam path including the object is carried by primary part of the beam. It is well known that the accuracy of the image useful data carried by the primary part degrades by scattered part of the beam. In order to have the beam path quantitative information accurately, it is essential to obtain the primary part of the total signal purely. In current study, a practical approach using localized primary modulation has been proposed to extract the primary signal. A semi-transparent beam attenuation grid was used as the beam intensity modulator. Efficiency and accuracy of the approach was practically validated through thickness measurement of metallic planar steps as an illustrative example. Simplified practical implementation and availability of the required accessories are some of advantages of the proposed approach. The results are indicative of the fact that this approach can also be applied as a new technique in thickness measurement, yielding a noticeable accuracy improvement in the most radiography methods. A procedure is included to explain the approach implementation for thickness measurement in computed radiography systems. The procedure overcomes some practical limitations and difficulties of the approach adaptation for computed radiography.

42 ENGINEERING↗

Tests of cosmic ray radiography for power industry applications

In this report, we assess muon multiple scattering tomography as a non-destructive inspection technique in several typical areas of interest to the nuclear power industry, including monitoring concrete degradation, gate valve conditions, and pipe wall thickness. This work is motivated by the need for imaging methods that do not require the licensing, training, and safety controls of x-rays, and by the need to be able to penetrate considerable overburden to examine internal details of components that are otherwise inaccessible, with minimum impact on industrial operations. In some scenarios, we find that muon tomography may be an attractive alternative to more typical measurements.

36 MATERIALS SCIENCE↗

INDUSTRY ENGAGEMENT TO ESTABLISH A ROBUST SECURITY APPROACH TO MOBILE RADIOACTIVE SOURCES

The mobile radiological sources used in the well-logging and radiography industries are of sufficient curie quantities to be categorized as desirable material for malicious actors. Beyond the security risk posed by these sources, there is also an understanding of the potential damage, both reputational and monetary, that a lost source would have on the licensee and the industry overall. Identifying and communicating the risk these sources pose with impacted stakeholders is a critical first step in developing a security approach. Common day-to-day operations within both industries drive the unique security challenge of mobile sources. From storage facilities, transportation vehicles, temporary storage locations, and use in the field, each phase creates challenges regarding source control and accountability. All aspects of the operational use of these sources needs to be fully understood in order to address security equipment enhancements, policies, procedures, and training. This paper will leverage more than ten years of experience that ORS has gained working closely with industry partners and mobile radiological source users across the well-logging and radiography industries. It will identify the risk posed by mobile radiological sources, clearly define the operational phases of each industry, identify security best practices of mobile sources, and discuss what long-term, sustainable security looks like within these industries. In addition, it will explore areas of a robust security approach that are not commonly given priority in these industries, such as alarm adjudication and response.

Office of Radiological Security↗

New mesh-type phantoms and their dosimetric applications, including emergencies

Committee 2 of the International Commission on Radiological Protection (ICRP) has constructed mesh-type adult reference computational phantoms by converting the voxel-type ICRP Publication 110 adult reference computational phantoms to a high-quality mesh format, and adding those tissues that were below the image resolution of the voxel phantoms and therefore not included in the Publication 110 phantoms. The new mesh phantoms include all the necessary source and target tissues for effective dose calculations, including the 8–40-µm-thick target layers of the alimentary and respiratory tract organs, thereby obviating the need for supplemental organ-specific stylised models (e.g. respiratory airways, alimentary tract organ walls and stem cell layers, lens of the eye, and skin basal layer). To see the impact of the new mesh-type reference phantoms, dose coefficients for some selected external and internal exposures were calculated and compared with the current reference values in ICRP Publications 116 and 133, which were calculated by employing the Publication 110 phantoms and the supplemental stylised models. The new mesh phantoms were also used to calculate dose coefficients for industrial radiography sources near the body, which can be used to estimate the organ doses of the worker who is accidentally exposed by an industrial radiography source; in these calculations, the mesh phantoms were deformed to reflect the size of the worker, and also to evaluate the effect of posture on dose coefficients.

Kim, C.H.↗

Experimental Measurement of Scatter to Primary Ratio by Localized Primary Modulation in Industrial Computed Radiography

The scatter-to-primary ratio (SPR), can serve as an important parameter for performing the scatter correction procedures or build up factor determination in radiography projections. In this work an experimental technique is presented based on localized primary modulation for direct SPR measurement. As illustrative examples, the SPR is measured for steel and aluminum step wedges to demonstrate the applicability of the presented technique in computed radiography. As a required parameter, the effective transmission factor of the modulator is measured using primary beam stopping concept over a calibration block. This technique has significant advantages such as a straight forward theory, simplified applicability in industrial site conditions, beam hardening consideration as well as automation possibility. The technique works by a single image acquisition, without image data loss in the interested area.

42 ENGINEERING↗

X-ray backscatter imaging for aerospace applications

Scatter x-ray imaging (SXI) is a real time, digital, x-ray backscatter imaging technique that allows radiographs to be taken from one side of an object. This x-ray backscatter imaging technique offers many advantages over conventional transmission radiography that include single-sided access and extremely low radiation fields compared to conventional open source industrial radiography. Examples of some applications include the detection of corrosion, foreign object debris, water intrusion, cracking, impact damage and leak detection in a variety of material such as aluminum, composites, honeycomb structures, and titanium.

07 ISOTOPE AND RADIATION SOURCES↗

Security of Mobile Radiological Sources: Overview of Industry Applied Technologies

Small radiological sources used in industrial settings recurrently require transit between job sites. Securing these sources, while stationary, can be addressed with standard security approaches and equipment. Transport of these sources increases the risk and complexity of managing and maintaining control of these sources. Implementing methodologies to securely monitor and locate sources improves response and resolution of anomalous events during transit. The Mobile Source Transit Security (MSTS) system was developed to improve security and provide situational awareness of these mobile sources throughout their job cycle. The MSTS development effort focused on creating a set of systems that could be successfully implemented in industrial radiography and well-logging applications. The MSTS team worked to address source presence and location through use and storage. The MSTS system monitors radiological sources as they move from the base of operations to the job site and back. The system provides near-real-time monitoring of the mobile source location and status and early notification of source loss or theft by transmitting operational status and alerting anomalous conditions over telematic links worldwide. The MSTS system can trigger an armed response or initiation of search and recovery operations and will automatically alert management and responsible staff if a radioactive source is lost or stolen whether it is on-site, in transport, or in storage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A review of computer aided interpretation technology for the evaluation of radiographs of aluminum welds

Industrial radiography is a well established, reliable means of providing nondestructive structural integrity information. The majority of industrial radiographs are interpreted by trained human eyes using transmitted light and various visual aids. Hundreds of miles of radiographic information are evaluated, documented and archived annually. In many instances, there are serious considerations in terms of interpreter fatigue, subjectivity and limited archival space. Quite often it is difficult to quickly retrieve radiographic information for further analysis or investigation. Methods of improving the quality and efficiency of the radiographic process are being explored, developed and incorporated whenever feasible. High resolution cameras, digital image processing, and mass digital data storage offer interesting possibilities for improving the industrial radiographic process. A review is presented of computer aided radiographic interpretation technology in terms of how it could be used to enhance the radiographic interpretation process in evaluating radiographs of aluminum welds.

Lloyd, J. F., Sr.↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

End of Life Decisions for Sealed Radioactive Sources

Sealed radioactive sources are encountered in a wide variety of settings – from household smoke detectors and instrument check sources, through fixed industrial gauges, industrial radiography and well logging sources, to irradiators and medical teletherapy devices. In general, the higher the level of activity in the sealed source, the stricter the regulatory control that is applied to its use, control and ultimate disposition. Lower levels of attention and oversight can and do lead to sources ending up in the wrong place – as orphan sources in uncontrolled storage, disposed in a sanitary landfill, melted down in metal recycling operations and incorporated into consumer products, or handled by an unsuspecting member of the public. There are a range of issues that contribute to the problem of improper disposal of sealed sources, and, in particular, to disused source disposal. General licensed sources and devices are particularly at risk of being disposed incorrectly. Higher activity general licensed sources, although required to be registered with the Nuclear Regulatory Commission (NRC) or Agreement State, receive limited regulatory oversight and are not tracked on a national scale. Users frequently do not consider the full life-cycle costs when procuring sources or devices and discover that they cannot afford to package, transport and dispose of their sources properly. The NRC requirements for decommissioning funding plans and financial assurance are not adequate to cover sealed source transport and disposal costs fully. While there are regulatory limits for storage of disused sources, enforcement is limited and there is no financial incentive for owners to dispose of the sources. In some cases, the lack of availability of approved Department of Transportation (DOT) Type B shipping casks also presents a barrier to sealed source disposal. The report of the Disused Sources Working Group does an excellent job of framing these issues. This article reviews both the issues and the report’s recommendations, which are designed to improve sealed source control and encourage proper disposal of disused sources.

disused source↗

Epidemiologic Study of One Million American Workers and Military Veterans Exposed to Ionizing Radiation

A pilot study was completed demonstrating the feasibility of conducting an epidemiologic study assessing cancer and other disease mortality among nearly one million US veterans and workers exposed to ionizing radiation, a population 10 times larger than atomic bomb survivor study with high statistical power to evaluate low dose rate effects. Among the groups enumerated and/or studied were: (1) 194,000 Department of Energy Uranium Workers; (2) 6,700 Rocketdyne Radiation Workers; (3) 7,000 Mound Radiation Workers; (4) 156,000 DOE Plutonium Workers; (5) 212,000 Nuclear Power Plant Workers; (6) 130,000 Industrial Radiography Workers; (7) 1.7 million Medical Workers and (8) 135,000 Atomic Veterans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Survey Report on Commercial Off-The-Shelf (COTS) Tracking Tools

Radioactive/nuclear (R/N) materials are integral parts of many business sectors such as medicine, industry, and research. In the United States alone, approximately 3 million packages containing R/N materials are shipped annually via highways, rail, air, and water. These materials are utilized in medical diagnostics and treatments, industrial radiography, and scientific research. The secure and efficient transportation of R/N materials is paramount to public safety and national security. Recent incidents involving the loss of R/N materials during transportation highlight significant security and safety concerns. For instance, in December 2024, a package containing four encapsulated Selenium-75 sources was reported lost in transit from the Czech Republic to Madrid, raising alarms about the security of such shipments. Similarly, a Germanium-68 pin source was reported lost in transit in New Jersey in December 2024, underscoring the risks associated with transporting radioactive materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗