Chemical composition, pressure and temperature of the Martian atmosphere from data of infrared spectroscopy
Infrared spectroscopy to determine temperature, pressure, and chemical composition of Martian atmosphere
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Infrared spectroscopy to determine temperature, pressure, and chemical composition of Martian atmosphere
Infrared spectroscopic measurements on Mars atmosphere by Mariners 6 and 7
IR spectroscopy and lasers for analysis of atmosphere in air pollution research and monitoring
To recycle the mixed plastic wastes (MPW), it is important to obtain the compositional information online in real time. We present a sensing framework based on a convolutional neural network (CNN) and mid-infrared spectroscopy (MIR) for the rapid and accurate characterization of MPW. The MPW samples are placed on a moving platform to mimic the industrial environment. The MIR spectra are collected at the rate of 100 Hz, and the proposed CNN architecture can reach an overall prediction accuracy close to 100%. Therefore, the proposed method paves the way toward the online MPW characterization in industrial applications where high throughput is needed.
Phylloquinone (PhQ) is a molecule involved in photosynthetic electron transfer, where the local protein environment is known to tune the properties of PhQ through various noncovalent interactions. In this work, we determine how hydrogen bonding, one of these noncovalent interactions, alters the vibrational potential energy surface of PhQ. In addition, this work demonstrates how hydrogen bonding to PhQ manifests in ultrafast multidimensional vibrational spectra, which is an important step towards using ultrafast vibrational based spectroscopies to probe PhQ embedded in the binding pocket of photosynthetic reaction centers.
Reactive organic fluid - mineral interactions at elevated temperatures contribute to the evolution of planetary matter. One of the less studied but important transformations in this regard involves the reactions of formic acid with naturally occurring clays such as sodium montmorillonite. To advance a mechanistic understanding of these interactions, we use ReaxFF reactive molecular dynamics simulations in conjunction with infrared (IR) spectroscopy and X-ray scattering experiments to investigate the speciation behavior of water-formic acid mixtures on sodium montmorillonite interfaces at 473 K and 1 atm. Using a newly developed reactive forcefield, we show that the experimental IR spectra of unreacted and reacted mixture can be accurately reproduced by ReaxFF/MD. We further benchmark the simulation predictions of sodium carbonate and bicarbonate formation in the clay interlayers using Small and Wide-Angle X-ray Scattering measurements. Subsequently, leveraging the benchmarked forcefield, we interrogate the pathway of speciation reactions with emphasis on carbonate, formate, and hydroxide groups elucidating the energetics, transition states, intermediates, and preferred products. Further, we also delineate the differences in reactivities and catalytic effects of clay edges, facets, and interlayers owing to their local chemical environments, which have far reaching consequences in their speciation behavior. The experimental and simulation approaches described in this study and the transferable forcefields can be applied translationally to advance the science of clay-fluid interactions for several applications including subsurface fluid storage and recovery and clay-pollutant dynamics.
The infrared spectrometer and radiometer for the Mariner-Jupiter-Saturn mission is described. Results of Nimbus and Mariner 9 IR spectroscopy of earth and Mars are used as examples to demonstrate the power and diversity of the technique. Determinations of planetary surface compositions, surface temperatures, vertical temperature profiles, surface pressures, and atmospheric constituents are summarized. Applications to Jupiter and Saturn are briefly mentioned.
We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.
The infrared absorption of argon (200 to 760 torr) and hydrogen chloride (2 to 6 torr) mixtures is reexamined in the missing Q branch region (spectral region between 2860 and 3010 wavelength/cm) at temperatures ranging from 195 to 298 K. The temperature dependence of two absorption features of the argon hydrogen chloride complex, at 2887 and 2879 wavelength/cm, leads to a bond energy estimate that depends on the assumptions made about the internal degrees of freedom of the complex. It is shown that agreement with experiment can be reached for well depths near 1.2 kcal/mole. This result is relatively insensitive to the choice of the vibrational frequencies and anharmonicities, but does depend on the extent to which the energy level manifolds are truncated to avoid molecular excitation in excess of the bond energy. The bond energy is found to deviate from the commonly accepted value of 0.4 kcal/mole. Possible causes for the discrepancy are considered.
Lattice vibrations and optical and infrared spectroscopy investigation
Two-dimensional infrared spectroscopy of vibrational probes at an electrode surface shows promise for studying the structural dynamics at an active electrochemical interface. This interface is a complex environment where the solution structures in response to the applied potential. A strategy for achieving the necessary monolayer sensitivity is to use a plasmonically active electrode, which enhances the electromagnetic fields that produce the spectroscopic response. Here, in this study, we show how the coupling between the plasmon and the vibrations of the molecular monolayer impacts the FTIR and 2D IR spectroscopy, with an emphasis on the electrochemical potential difference spectra. We show how mixing between the vibrational and plasmonic states gives rise to the distortions that are observed in these measurements. This provides an important step toward 2D IR measurements of vibrational probes at the electrochemical interface as a tool for probing the structural dynamics in the double layer.
Astronomical infrared spectroscopy from aircraft
Infrared (IR) spectroscopy is a powerful method for mapping chemical heterogeneity on the microscale. Synchrotron IR radiation uniquely provides a high brightness and broad bandwidth to further extend the capabilities of IR spectroscopic imaging. However, the diffraction-limited spatial resolution of IR spectroscopy is insufficient for studies requiring submicrometer spatial differentiation. Optical photothermal IR (O-PTIR) microscopy is a powerful, emerging method that overcomes the IR diffraction limit in IR hyperspectral imaging by employing a modulated IR beam and a visible probe laser beam to detect local temperature-induced modulation at the visible diffraction limit. In this work, we extend the spectral range of photothermal infrared measurements by incorporating a synchrotron IR source, demonstrating a combined synchrotron-based O-PTIR modality that enables high spatial resolution far-field chemical imaging spanning the entire mid-IR range. Both optical- and fluorescence-detected photothermal modalities were performed using a step-scan interferometer, demonstrating improved spectral range (541-4000 cm-1) when compared to optical photothermal microscopy with commercial laser sources (800-1800 cm-1 for this particular source) and improved spatial resolution, when compared to synchrotron microspectroscopy measurements. Following these initial validation studies, synchrotron Fourier-transform fluorescence-detected photothermal IR spectroscopy in combination with synchrotron microspectroscopy measurements was used to differentiate cells in mouse brain tissue sections, which requires submicron spatial resolutions beyond those accessible by IR spectroscopy alone.
Optical and infrared spectroscopic studies of single crystal fluoride perovskites and potassium compounds to determine transmission spectra and ferroelectricity
Mid-infrared spectroscopy enables biochemical sensing by identifying vibrational molecular fingerprints, but it faces limitations in instrumentation portability and analytical sensitivity. Optical metasurfaces with strong mid-infrared photonic resonances provide an attractive solution towards on-chip spectrometry and sensitive molecular detection, yet their static nature hinders their anticipated impact. Here, we introduce and demonstrate dynamically tunable silicon membrane metasurfaces exhibiting high-Q transmissive resonances in the fingerprint region. By harnessing silicon’s thermo-optical properties, we achieve continuous modulation of coupling-induced transparency (CIT) modes that emerge upon the interference of quasi-bound states in the continuum (q-BICs) and surface lattice modes (SLMs). We measure a spectral tuning rate of 0.06 cm −1 K −1 by continuously sweeping the sharp CIT resonances over a 23.5 cm −1 spectral range across a temperature range of 300–700 K. In the current proof‑of‑concept implementation, the dynamic transmission control enables non-contact chemical analysis of polymer films by detecting characteristic absorption bands of polystyrene (1450 and 1492 cm −1 ) and poly(methyl methacrylate) (1730 cm −1 ) without requiring conventional spectrometers. When analyte molecules fill the metasurface-generated photonic cavities, we demonstrate vibrational strong coupling between the poly(methyl methacrylate)’s carbonyl band and the CIT mode, manifested in a Rabi splitting of ~43 cm −1 . Our results establish a new photonic platform that unites spectral precision, strong field enhancement, and reconfigurability, offering diverse potential for compact mid-infrared spectroscopy, molecular sensing, and programmable polaritonic photonics.
The infrared spectroscopy experiment on Mariner 9 obtained data over much of Mars. Interpretation of the thermal emission of Mars in terms of atmospheric temperatures, wind fields and dynamics, surface temperatures, surface pressure and topography, mineral composition, and minor atmospheric constituents including isotopic ratios, as well as a search for unexpected phenomena are reported.
Infrared spectroscopy provides unique insights into the chemistry and dynamics of the atmospheres of Jupiter, Saturn, and Titan. In 1991 we obtained data at J, H, K, and M and made repeated observations of Titan's albedo as the satellite orbited Saturn. The J albedo is 12% +/- 3% greater than the albedo measured in 1979; the H and K albedos are the same. There was no evidence for variations at any wavelength over the eastern half of Titan's orbit. We also obtained low resolution (R=50) spectra of Titan between 3.1 and 5.1 microns. The spectra contain evidence for CO and CH3D absorptions. Spectra of Callisto and Ganymede in the 4.5 micron spectral region are featureless and give albedos of 0.08 and 0.04 respectively. If Titan's atmosphere is transparent near 5 microns, its surface albedo there is similar to Callisto's. In 1992 and 1993 we obtained further spectroscopic data of Titan with the UKIRT CGS4 spectrometer. We discovered two unexpected and unexplained spectral features in the 3-4 micron spectrum of Titan. An apparent emission feature near the 3 micron (nu sub 3) band of methane indicated temperatures higher than known to be present in Titan's upper stratosphere and may be caused by unexpected non-LTE emission. An absorption feature near 3.47 microns may be caused by absorption in solid grains or aerosols in Titan's clouds. The feature is similar but not identical to organics in the interstellar matter and in comets.