Search NASASearch

SEARCH · Search NASA

Results for “INSTRUMENT & FEATURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanical design of a parallel flexure-based RADSI instrument for curved x-ray mirror metrology

Modern synchrotron x-ray beamlines demand reflective optics with higher surface profile accuracy to achieve diffraction-limited focusing. This necessitates advanced metrology instruments capable of delivering repeatable measurements in the nanometer to sub-nanometer range. Slope ranges exceeding 15 mrad (0.86°) and greater pose significant challenges for mirror metrology using conventional interferometric methods. Here, to address this, we present a new relative angle determinable stitching interferometry instrument featuring a parallel flexure-based mechanical design. This approach enhances vibration and thermal stability while maintaining a compact and lightweight system. Initial measurements of a cylindrical mirror with a 16 m radius of curvature and a slope range of 5 mrad demonstrate nanometer-level repeatability. Comprehensive system characterization suggests the potential for achieving sub-nanometer repeatability with further refinement to the instrument.

36 MATERIALS SCIENCE

The GammaTPC Gamma-Ray Telescope Concept

We present GammaTPC, a transformative 0.1-10 MeV $\gamma$-ray instrument concept featuring a tracker using a liquid argon time projection chamber (LAr TPC) technology with the novel GAMPix high spatial resolution and ultra low power charge readout. These enable an economical instrument with unprecedented effective area and sensitivity. We discuss the design and technology in some detail, including how a LAr TPC can be staged in space. Finally, we present a first study of the sensitivity of the instrument in the Compton regime using a new framework for analyzing Compton telescope data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Report on the "Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments"

An international group of researchers gathered for the “Symposium on Advancements in Simulating Neutron Scattering Instruments and Experiments” at Oak Ridge National Laboratory (ORNL) on October 29- 30, 2024. The symposium highlighted state-of-the-art advancements in neutron scattering instrument simulations and the development of digital twins for scattering instruments. This document summarizes the recurring themes from the 19 talks and discussions. A key focus was on the role of neutronics simulations in the design, analysis, and performance optimization of neutron instruments. Presentations featured the most widely used software packages, such as McStas, McVine, Vitess, and MCNP. Another major theme addressed the analysis and interpretation of experimental neutron data, where materials models and simulations play a critical role. Talks on relevant software tools, including NCrystal, OCLimax, and Paradyse, were delivered by their respective developers. During the symposium, both talks and breakout sessions explored strategies to enhance the interplay between neutronics simulations and materials models. A key question emerged: How can we develop a RealTime Explainable Digital Twin of a neutron scattering experiment? Discussions include the idea that the Digital Twin concept has implications for instrument control and testing. Through this symposium, we gained valuable insights into the challenges and requirements for developing a Real-Time Explainable Digital Twin of a neutron scattering experiment. The discussions and presentations paved the way for future innovations in this rapidly advancing field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE

Fiber-Optic Sensing for Earthquake Hazards Research, Monitoring, and Early Warning

The use of fiber‐optic sensing systems in seismology has exploded in the past decade. Despite an ever‐growing library of ground‐breaking studies, questions remain about the potential of fiber‐optic sensing technologies as tools for advancing if not revolutionizing earthquake‐hazards‐related research, monitoring, and early warning systems. A working group convened to explore these topics; we comprehensively examined the application of fiber optics in various aspects of earthquake hazards, encompassing earthquake source processes, crustal imaging, data archiving, and technological challenges. There is great potential for fiber‐optic systems to advance earthquake monitoring and understanding, but to fully unlock their capabilities requires continued progress in key areas of research and development, including instrument testing and validation, increased dynamic range for applications focused on larger earthquakes, and continued improvement in subsurface and source imaging methods. A key current stumbling block results from the lack of clear data archiving requirements, and we propose an initial strategy that balances data volume requirements with preserving key data for a broad range of future studies. In addition, we demonstrate the potential for fiber‐optic sensing to impact monitoring efforts by documenting the data completeness in a number of long‐term experiments. Finally, we outline the features of a instrument testing facility that would enable progress toward reliable and standardized distributed acoustic sensing data. Overcoming these current obstacles would facilitate progress in fiber‐optic sensing and unlock its potential application to a broad range of earthquake hazard problems.

58 GEOSCIENCES

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS

Landsat Instrument Suite (LandIS) Sensor Design for the Landsat 10 Mission

Landsat 10 will be the upcoming mission in the 50+ year Landsat series of Earth observation platforms. The centerpiece of the observatory will be a super-spectral imager known as the Landsat Instrument Suite (LandIS). The sensor will feature 26 spectral channels from the visible through near-, short-wave, and thermal infrared wavelengths with spatial resolutions of 10, 20, and 60 meters on the ground, depending on the band. These enhancements over the legacy Landsat instruments will ensure data continuity with the existing archive and will expand upon the core Landsat capabilities to enable new applications in Earth science. After a competitive procurement, NASA selected the design submitted by the Raytheon Company for the LandIS instrument. The innovative Raytheon instrument concept utilizes an advanced whiskbroom architecture to fulfill the strict radiometric, spatial, and geometric image quality requirements demanded by the Landsat 10 mission and fits within restrictive mass, volume, and power constraints. The instrument will continue the Landsat directive to image all daylit land and near-shore water areas, along with select nighttime imaging. On-board calibration source data will ensure high radiometric and geometric accuracy and stability consistent with previous missions to enable continuity in data products available to users. This paper discusses the driving requirements for LandIS and provides a description of the chosen design and operations concept of the instrument.

Requirements

High-Resolution Sampling of a River Plume Front with Uncrewed Underwater and Aerial Vehicles

Sampling fast-propagating oceanic features is inherently challenging and demands versatile instrumentation and innovative strategies. This paper introduces a novel sampling strategy designed to capture such phenomena, exemplified by a river plume front. Our method revolves around modifying the preprogrammed pathway of an uncrewed underwater vehicle (UUV) to dynamically track and three-dimensionally sample the evolution of the front. To enable the UUV to follow the feature, we adapt the use of a drifting gateway buoy to be positioned and trapped at the front’s convergence zone, allowing underway navigation relative to the buoy. In our demonstration, we showcase the effectiveness of this strategy by successfully conducting over 30 crossings of a river plume front within a 6-h window. The UUV sensors allowed a comprehensive assessment of key front characteristics, including density, velocity, and turbulence. Supplemental drone footage contributed to the overall picture and facilitated the transformation of the dataset into a front-following reference frame. This article provides an in-depth description of the deployment strategy and required postcollection data processing, including frontal crossing detection, the assessment of the frontal orientation from drone footage, and defining the plume bottom boundaries using backscatter intensity contours.

autonomous observations

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM

Building Datasets and Training Methods for ML Based Magnet Quench Detection

Detecting quenches in superconducting (SC) magnets during training is a challenging process that involves capturing physical events that occur at different frequencies and appear as various signal features. These events may be correlated across instrumentation type, thermal cycle, and ramp. These events together build a more complete picture of continuous processes occurring in the magnet, and may allow us to flag potential precursors for quench detection. We present our work on building an automatic machine learning (ML) based quench detection system. We build upon our existing work on unsupervised auto-encoders for acoustic sensors and quench antenna (QA) by first establishing a supervised ML training pipeline. We show the results of an event tagging, analysis, and simulation framework on our QA and acoustic data which are used concurrently to build a training dataset for a supervised implementation. We then show how this supervised training can be used as a prior in a semi-supervised framework and compare this to the unsupervised neural network auto-encoder performance.This allows us to have a more concrete understanding of the performance of our algorithms relative to physical events occurring in the magnet, and also provides a baseline software tool to generically evaluate our quench prediction autoencoders under completely unsupervised, supervised, and semi-supervised training conditions.

Khan, Maira [Fermilab]

Quantitative approaches for multiscale structural analysis with atomic resolution electron microscopy

Atomic-resolution imaging with scanning transmission electron microscopy is a powerful tool for characterizing the nanoscale structure of materials, in particular features such as defects, local strains, and symmetry-breaking distortions. In addition to advanced instrumentation, the effectiveness of the technique depends on computational image analysis to extract meaningful features from complex datasets recorded in experiments, which can be complicated by the presence of noise and artifacts, small or overlapping features, and the need to scale analysis over large representative areas. Here, we present image analysis approaches which synergize real and reciprocal space information to efficiently and reliably obtain meaningful structural information with picometer scale precision across hundreds of nanometers of material from atomic-resolution electron microscope images. Damping superstructure peaks in reciprocal space allows symmetry-breaking structural distortions to be disentangled from other sources of inhomogeneity and measured with high precision. Real-space fitting of the wavelike signals resulting from Fourier filtering enables absolute quantification of lattice parameter variations and strain, as well as the uncertainty associated with these measurements. Implementations of these algorithms are made available as an open source python package.

36 MATERIALS SCIENCE

Ultracold cryogenic TEM with liquid helium and high stability

Cryogenic transmission electron microscopy has revolutionized structural biology and materials science. To image below liquid nitrogen temperatures, various liquid helium stages have been constructed but have proven to be complex and unstable, making high-resolution imaging challenging. This problem is even more pronounced in side-entry specimen holders common on modern transmission electron microscopes. Here, we introduce an ultracold liquid helium transmission electron microscope side-entry specimen holder, featuring continuous cryogen flow and vibration decoupling. This instrument is compatible with modern aberration-corrected microscopes and achieves sub-25 K base temperature, ±2 mK thermal stability over many hours, and atomic resolution—setting the stage for a new era of cryogenic electron microscopy.

42 ENGINEERING

The Design and Use of Calorimeters For Characterization of High-Enthalpy Flows in Arc-Heated Test Facilities

High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.

D Mark Smith

Rapid Generation of Tandem Mass Spectrometry Reference Libraries Using Immediate Drop-on-Demand Liquid Handling Coupled to an Open Port Sampling Interface

In metabolomics, tandem MS (MS2) fragmentation libraries are important for the identification of unknown features, but generating these libraries takes many valuable hours of instrument and operator time. Here, an immediate droplet-on-demand/open port sampling interface was used to rapidly acquire tandem MS of standards arrayed in a 96-well plate format. A workflow was developed for automated, high-throughput control of MS2 library generation. Pure standard mass spectral libraries were collected on Orbitrap and Q-TOF mass spectrometers for 192 compounds using 6 different collision energies with a throughput of 4 and 7.8 s/spectrum, respectively. Libraries were acquired using different solvent additives, precursor adducts, and ion polarities.

Cahill, John [ORNL] (ORCID:0000000298664010)

FY26 Mid-Year Report Self-Diagnostic Capabilities for Neutron Instruments

This year we will transfer the latest version of INCC6 with last year’s self-diagnostic features to the IAEA. In FY25 we completed the development of three automated self diagnostic features into INNC6. The completion of these features marked the final stable version of INCC 6.0 ready for release to the IAEA and other users. In the first half of the Fiscal Year 2026 we have worked with LANL’s Feynman Center and Export Control office to attain a license for exporting INCC6 to the IAEA. We have successfully attained the export license for INCC6, and contacts at the IAEA have been granted permission to receive INCC6. We are in the final stage of writing the version 6 user manual. Once this is complete, we will deliver INCC6 to the IAEA for testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Precision measurements of EFT parameters and BAO peak shifts for the Lyman- α forest

We present precision measurements of the bias parameters of the one-loop power spectrum model of the Lyman- α (Ly- α ) forest, derived within the effective field theory (EFT) of large-scale structure. We fit our model to the three-dimensional flux power spectrum measured from the ACCEL 2 hydrodynamic simulations. The EFT model fits the data with an accuracy of below 2% up to k = 2 h Mpc − 1 . Further, we analytically derive how nonlinearities in the three-dimensional clustering of the Ly- α forest introduce biases in measurements of the baryon acoustic oscillations (BAOs) scaling parameters in radial and transverse directions. From our EFT parameter measurements, we obtain a theoretical error budget of Δ α ∥ = − 0.2 % ( Δ α ⊥ = − 0.3 % ) for the radial (transverse) parameters at redshift z = 2.0 . This corresponds to a shift of − 0.3 % (0.1%) for the isotropic (anisotropic) distance measurements. We provide an estimate for the shift of the BAO peak for Ly- α -quasar cross-correlation measurements assuming analytical and simulation-based scaling relations for the nonlinear quasar bias parameters resulting in a shift of − 0.2 % ( − 0.1 % ) for the radial (transverse) dilation parameters, respectively. This analysis emphasizes the robustness of Ly- α forest BAO measurements to the theory modeling. We provide informative priors and an error budget for measuring the BAO feature—a key science driver of the currently observing Dark Energy Spectroscopic Instrument (DESI). Our work paves the way for full-shape cosmological analyses of Ly- α forest data from DESI and upcoming surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST. Published by the American Physical Society 2025

de Belsunce, Roger (ORCID:0000000336604028)

APPL Hyperspectral_Imaging_Dataset_for_Heritability_Analysis_in_Populus_trichocarpa

This dataset contains hyperspectral imaging data collected at the Advanced Plant Phenotyping Laboratory (APPL) at Oak Ridge National Laboratory. Natural variants of Populus trichocarpa were imaged using a high-throughput hyperspectral phenotyping pipeline to quantify spectral reflectance traits for downstream quantitative genetics analyses. The dataset includes hyperspectral image files and derived reflectance data products suitable for extracting spectral features across the measured wavelength range (e.g., VNIR and/or SWIR, depending on instrument configuration), along with associated sample metadata (e.g., genotype identifiers, experimental design factors, and imaging run identifiers). These data were generated to support analyses of broad-sense heritability of hyperspectral traits and their relationships with biochemical phenotypes (including lignin traits from Py-MBMS).

APPL

Geochemistry of Mars with Laser-Induced Breakdown Spectroscopy (LIBS): ChemCam, SuperCam, and MarSCoDe

Laser-induced breakdown spectroscopy (LIBS) has been used to explore the chemistry of three regions of Mars on respective missions by NASA and CNSA, with CNES contributions. All three LIBS instruments use ~100 mm diameter telescopes projecting pulsed infrared laser beams of 10–14 mJ to enable LIBS at 2–10 m distances, eliminating the need to position the rover and instrument directly onto targets. Over 1.3 million LIBS spectra have been used to provide routine compositions for eight major elements and several minor and trace elements on >3000 targets on Mars. Onboard calibration targets common to all three instruments allow careful intercomparison of results. Operating over thirteen years, ChemCam on Curiosity has explored lacustrine sediments and diagenetic features in Gale crater, which was a long-lasting (>1 My) lake during Mars’ Hesperian period. SuperCam on Perseverance is exploring the ultramafic igneous floor, fluvial–deltaic features, and the rim of Jezero crater. MarSCoDe on the Zhurong rover investigated for one year the local blocks, soils, and transverse aeolian ridges of Utopia Planitia. The pioneering work of these three stand-off LIBS instruments paves the way for future space exploration with LIBS, where advantages of light-element (H, C, N, O) quantification can be used on icy regions.

47 OTHER INSTRUMENTATION