Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTS, LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Deployment Gamma Instruments Laboratory Exercise

The instructional goals for this session are to provide participants with a thorough understanding of gamma-ray spectroscopy techniques and to familiarize them with the operation and performance of the NCV-owned gamma-ray instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of SimulCam, a standoff Raman system for scientific support of SuperCam operations on Mars

During the development activities of SuperCam Calibration Target, target intended for one of the two first Raman instruments to be deployed on another planetary body, our group developed a laboratory instrument that could simulate to some extent the Raman capabilities of one of such instruments and could provide data with similar quality. The use of this kind of laboratory instruments has demonstrated its utility in the evaluation of potential calibration targets or anticipating the science outcome that an instrument could provide. The present work describes our laboratory setup to support SuperCam, evaluating similarities between both instruments, despite of differences in the hardware. Evaluation of data gathered by SuperCam on Mars and the availability of one replica of SuperCam’s Calibration Target allowed the comparison on the same set of targets, demonstrating how similar Signal-to-Noise Ratio (SNR) could be achieved from both instruments. The higher energy per pulse on SimulCam is compensated by a greater analytical footprint and the use of smaller collection optics. The results show how spectra obtained at representative distances of SuperCam are comparable. Operational principles are also comparable in terms of time resolution, and close in terms of spectral resolution. This similarity has allowed different science support works using SimulCam data, as well as the support to Mars detections using our setup. We provide examples of this support that will be shared with the community in different papers, as well as examples of possible operations activities that could benefit from experiments performed with SimulCam. We show how this setup can complement the two laboratory replicas in Los Alamos and Toulouse in providing support data to different experiments.

47 OTHER INSTRUMENTATION↗

SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation that is designed to operate on live cables up to 1000 volts and with a bandwidth of 48 MHz. Initial evaluation by the Pacific Northwest National Laboratory (PNNL) of the Live Wire system indicated that a broader bandwidth (BW) SSTDR may be better for many kinds of flaws. This led PNNL to develop an SSTDR laboratory instrument suitable for tests up to 500 MHz bandwidth. Testing on energized cables is also desirable for online monitoring systems so an inductive clamshell coupler was developed that allows energized cables to be tested up to at least 5 kV and likely higher voltage levels. Dielectric spectroscopy and tan delta testing plus various laboratory destructive tests were included in this data acquisition campaign directed to feed a machine learning (ML) study. With these kinds of developments, online energized cable tests may be possible with industrial adoption of such hardware advances but it will be completely impractical to have highly skilled data analysts continually examine these complex signals for indications of damage or compromised conditions. If online testing is to be implemented in new test hardware, it must be accompanied by software that can interpret the signals and alert plant operators of changing or degraded conditions. The thermally aged, shielded cable investigated here was separately treated for ML analysis. Visual analysis of electrical data showed generally increasing peaks where the cable entered and exited the oven. These peaks were not exactly aligned with expected locations, but these differences were attributed to velocity of propagation calibration errors. Only supervised ML was applied to the thermally aged data as this data was only available shortly before the committed publication date of this report. The supervised ML was structured to divide the 0 to 70-day responses as ‘normal’ from 0 to 35 days or ‘anomalous’ from 36 to 70 days, based on cable tensile elongation at break (EAB) insulation characterization. Using 80% of the data for training and 20% for testing, the supervised ML predicted normal versus anomalous was 70% accurate. Important conclusions include: • Accuracy to predict the presence of cable damage is improved from the 2023 effort by more training data. Weighted accuracies for comparisons among the instruments ranged from 67 to 89 % for unsupervised ML and 71 to 99% for supervised ML. • Based on the synthetic data tests, the unsupervised models are more generalizable to unseen anomalies. The Multi-Layer Perceptron classifier (MLP) model reported as high as 99.7% accuracy on the test data, but this dropped to 58.3% when tested on the synthetic data. In contrast, the unsupervised Pointwise model only achieved 89.7% accuracy on the experimental data but reported 78.3% accuracy on the synthetic data. • The best anomaly indicators are higher frequency (400 MHz BW) FDR data. Other tests may be interesting but for this study, this was the best predicter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

Dataset for Cruz-O'Byrne et al (2026): "Divergent biogeochemical responses in upland coastal forest soils to repeated flooding and shifts in water chemistry"

Hydrologic disturbances from accelerated sea-level rise and the increasing frequency and intensity of storms and tidal flooding are altering biogeochemical processes in upland coastal forests, transforming these ecosystems into wetlands. However, the initial effects of flooding on belowground biogeochemistry and the mechanisms driving greenhouse gas dynamics and soil organic matter stability during the early stages of this transition remain poorly understood. This dataset presents the results of a mesocosm experiment conducted in a controlled, highly instrumented laboratory environment, in which freshwater and brackish water pulses were applied to intact soil monoliths from a temperate upland coastal forest to examine how floodwater chemistry influences soil biogeochemistry and organo-mineral interactions. All data files are plain-text CSV (comma-separated value), and no special software is required to read them. Details about the content of each file are available in the document “Dataset_readme”. The dataset consists of the following data: • rcruzobyrne_moisture: Soil volumetric water content (VWC) • rcruzobyrne_GHG: Headspace greenhouse gas (GHG) concentration and fluxes • rcruzobyrne_methane_isotopes: Headspace methane isotope signature • rcruzobyrne_porewater: Porewater chemistry • rcruzobyrne_CDOM: Porewater colored dissolved organic matter (CDOM) • rcruzobyrne_FTIR: Soil Fourier-transform infrared (FTIR) spectroscopy Details of the experimental setup, data collection, and data analysis are provided in the manuscript by Cruz-O’Byrne et al (2026) Divergent biogeochemical responses in upland coastal forest soils to repeated flooding and shifts in water chemistry. Biogeochemistry. https://doi.org/10.1007/s10533-026-01340-0

EARTH SCIENCE > ATMOSPHERE > GREENHOUSE GAS↗

A 291-day Evaluation of the Performance of a Consumer-grade Temporal Radon Detector

Affordable, accurate, and robust temporal measurement devices are desirable for screening and assessment of radon levels in private homes and workplaces. This research expands upon prior research, using the RadonFTlab RadonEye device through a comparison of multiple samples of this instrument with a laboratory-grade instrument, the Saphymo AlphaGUARD, over a more extensive period than reported previously. Data were collected over 291 d in a poorly ventilated basement space in an occupied building. Environmental conditions varied naturally, changing both the radon source term and radon entry into the space approximating typically deployed conditions. The R-squared linear regression correlation coefficient and relative sensitivities of each RadonEye with the AlphaGUARD were computed. Altogether temporal and diurnal variations were also studied. The sensitivities of all RadonEyes and the AlphaGUARD agreed to within 22% throughout the entire deployment period.

47 OTHER INSTRUMENTATION↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

This document describes the development of a field programable gate array (FPGA) radio frequency system on a chip (RF SoC) adaptation and evaluation of the single-board device to perform both Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR) for offline and online cable testing. The work builds on and leverages the work of Pacific Northwest National Laboratory (PNNL) in airport millimeter wave technology by using the same development hardware employed in that program. The work is performed under sponsorship from the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program and the task objective is to confirm and demonstrate feasibility to adapt FPGA technology for a cost-effective multiplexed single-board electronic module to perform cable tests that are equivalent to commercial and laboratory test instruments for FDR and SSTDR cable tests. The developed 2-channel (extendable to 7 channels) system was compared to dedicated and proven test instruments and shown to produce equivalent results on a range of cables and with a range of damage types. The FPGA reflectometry test board is one of several technologies that could facilitate implementation of online monitoring of safety critical cable systems.

42 ENGINEERING↗

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY↗

Downwelling Shortwave and Longwave Irradiance from CC-RIDER on Mount Soledad

The Clouds and Climate - Remote Integrated Deployment of Radiometers (CC-RIDER) is a suite of five Eppley Laboratory (Inc.) instruments that was deployed during EPCAPE at the secondary Mount Soledad site in La Jolla, CA. A primary and backup Precision Spectral Pyranometer (PSP Primary, PSP Backup) measured broadband downwelling shortwave irradiance in the spectral interval 280-2800 nm. A third Precision Spectral Pyranometer (PSP NIR) was fitted with a near-infrared long pass filter and measured downwelling shortwave irradiance in the spectral interval 780-2800 nm. A Total Ultraviolet Radiometer (TUVR) measured broadband downwelling broadband ultraviolet irradiance in the spectral interval 295-385 nm. A Precision Infrared Radiometer (PIR) Pyrgeometer measured downwelling broadband longwave irradiance in the spectral interval 3.5 - 50 microns. Data collection began on 18 April 2023 at 21:31 UTC and ended on 20 February 2024 at 22:34 UTC. Data were recorded by a Campbell Scientific (Inc.) CR1000X datalogger in one-minute intervals, for a total of 443584 data records. The datalogger was solar powered enabling data collection to proceed without interruption from start to finish.

Clouds and Climate – Remote Integrated DEployement↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2025 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2025 edition includes updates to the appendices to describe the current instrumentation of the NREL-SRRL.

14 SOLAR ENERGY↗

Standard Operating Procedure for Optimal Deployment of Meteorological Instrumentation Within the Solar Radiation Research Laboratory: 2024 Edition

The objective of the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) is to collect and use high-quality solar radiation data sets for research leading to the widespread adoption of solar technologies. To appropriately populate and track the diverse array of instruments at the NREL-SRRL, NREL has established a Standard Operating Procedure (SOP) for optimal instrument deployment within the SRRL for both the Baseline Measurement System (BMS) and the Research Measurement System (RMS). Using best practices methodologies, the NREL-SRRL maintains a varied and extensive array of solar monitoring equipment to test, evaluate, and characterize the solar sensors used by federal and international agencies as well as the solar industry to determine the solar resource. The SOP provides the industry with guidance for solar resource assessment and is used for procedures in the long-term continuous monitoring of legacy instruments alongside state-of-the-art instruments. Based on the SOP, instruments are annually evaluated for continued deployment. Instruments that do not meet the SOP criteria are decommissioned, and new instruments that meet the criteria are deployed. Streamlining and optimizing the use of this facility ensures that the lab continues to be a world-leading solar calibration and measurement facility. This 2024 edition includes updates to the appendices to reflect the instrument changes from one year to another.

14 SOLAR ENERGY↗

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Targeted Observations of Blowing Snow during SAIL (SAIL-TOBS) Field Campaign Report

Blowing snow research at high-latitude U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility observatories and mobile campaigns demonstrated the need for ground truth during falling and blowing snow events. The purpose of the Targeted Observations of Blowing Snow during SAIL (SAIL-TOBS) field campaign was to affordably deploy additional instruments to observe mixed-phase and frozen hydrometeors, including falling and blowing snow, during the second winter of the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign. Instruments included two installations of the Open Snowflake Camera for Research and Education (OSCRE), one at the Gothic, Colorado main site (second ARM Mobile Facility [AMF2]) and a second at the Kettle Ponds external field site in support of the Study of Precipitation, the Lower Atmosphere and Surface for Hydrometeorology (SPLASH) campaign. Two FlowCapt FC4 acoustic mass flux sensors were also deployed at AMF2 in proximity to OSCRE on top of the instrumented hill (Figure 1).

54 ENVIRONMENTAL SCIENCES↗

Multimodal Ambient Pressure Sample Environment for the HIPPIE Solid-Gas Endstation at MAX IV Laboratory

The HIPPIE APXPS instruments have undergone several major upgrades, such as developing a dedicated solid gas endstation to specialize in multimodal ambient pressure sample environments centered around X-ray photoelectron spectroscopy. Herein, the technical specifications of the HIPPIE solid gas endstation are detailed; upgrades to the laser heating and gas systems, as well as the addition of an offline 1 bar reactor, are introduced. To demonstrate how the endstation is currently being utilized, scientific examples of all upgrades are presented, as well as science cases using infrared reflection-adsorption spectroscopy. The HIPPIE solid gas endstation is maturing into an instrument offering bespoke sample environments aimed at pushing experimental capabilities, especially in the time-resolved domain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Method Optimization with Categorical and Constrained Continuous Parameters

Traditional approaches to analytical method optimization (e.g., univariate and “guess-and-check”) can be time-consuming, costly, and often fail to identify true optima within the parameter space. Previous work defined and implemented a generalized technique for method optimization for continuous method parameters, but a knowledge gap remains for the incorporation of categorical variables into these advanced method optimization schemes. This work presents and validates a generalized optimization approach that incorporates both continuous and categorical variables while also utilizing a multivariate, multiobjective optimization scheme with Karush–Kuhn–Tucker conditions to bound the optimization space to solutions within the physical limitations of the parameter space. Method optimization from a case study using GC–MS for the analysis of 11 analytical standards with objectives to minimize peak width and maximize peak height resulted in a 3 orders of magnitude improvement in the average peak height and a 2 orders of magnitude improvement in the average peak width compared to the least optimal (but reasonable) instrumental parameters utilized in this study. This approach to optimization allows for a customizable method optimization in which users can include both continuous and categorical variables to achieve objectives specific to their analytical goals. This approach significantly reduces the labor and cost associated with traditional method development approaches and can be applied in a variety of scientific fields across a range of laboratory techniques (e.g., instrument method development, sample preparation, and extraction techniques).

Amorphous materials↗