Search NASASearch

SEARCH · Search NASA

Results for “INSTRUMENTS FOR MEASURING PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Physics of Hard Spheres Experiment on MSL-1: Required Measurements and Instrument Performance

The Physics of HArd Spheres Experiment (PHaSE), one of NASA Lewis Research Center's first major light scattering experiments for microgravity research on complex fluids, flew on board the Space Shuttle's Microgravity Science Laboratory (MSL-1) in 1997. Using colloidal systems of various concentrations of micron-sized plastic spheres in a refractive index-matching fluid as test samples, illuminated by laser light during and after crystallization, investigations were conducted to measure the nucleation and growth rate of colloidal crystals as well as the structure, rheology, and dynamics of the equilibrium crystal. Together, these measurements support an enhanced understanding of the nature of the liquid-to-solid transition. Achievement of the science objectives required an accurate experimental determination of eight fundamental properties for the hard sphere colloidal samples. The instrument design met almost all of the original measurement requirements, but with compromise on the number of samples on which data were taken. The instrument performs 2-D Bragg and low angle scattering from 0.4 deg. to 60 deg., dynamic and single-channel static scattering from 10 deg. to 170 deg., rheology using fiber optics, and white light imaging of the sample. As a result, PHaSE provided a timely microgravity demonstration of critical light scattering measurement techniques and hardware concepts, while generating data already showing promise of interesting new scientific findings in the field of condensed matter physics.

Doherty, Michael P.

Performance of the EGRET astronomical gamma ray telescope

On April 5, 1991, the Space Shuttle Atlantis carried the Compton Gamma Ray Observatory (CGRO) into orbit, deploying the satellite on April 7. The EGRET instrument was activated on April 15, and the first month of operations was devoted to verification of the instrument performance. Measurements made during that month and in the subsequent sky survey phase have verified that the instrument time resolution, angular resolution, and gamma ray detection efficiency are all within nominal limits.

Nolan, P. L.

Using Lunar Observations to Validate Pointing Accuracy and Geolocation, Detector Sensitivity Stability and Static Point Response of the CERES Instruments

Validation of in-orbit instrument performance is a function of stability in both instrument and calibration source. This paper describes a method using lunar observations scanning near full moon by the Clouds and Earth Radiant Energy System (CERES) instruments. The Moon offers an external source whose signal variance is predictable and non-degrading. From 2006 to present, these in-orbit observations have become standardized and compiled for the Flight Models -1 and -2 aboard the Terra satellite, for Flight Models-3 and -4 aboard the Aqua satellite, and beginning 2012, for Flight Model-5 aboard Suomi-NPP. Instrument performance measurements studied are detector sensitivity stability, pointing accuracy and static detector point response function. This validation method also shows trends per CERES data channel of 0.8% per decade or less for Flight Models 1-4. Using instrument gimbal data and computed lunar position, the pointing error of each detector telescope, the accuracy and consistency of the alignment between the detectors can be determined. The maximum pointing error was 0.2 Deg. in azimuth and 0.17 Deg. in elevation which corresponds to an error in geolocation near nadir of 2.09 km. With the exception of one detector, all instruments were found to have consistent detector alignment from 2006 to present. All alignment error was within 0.1o with most detector telescopes showing a consistent alignment offset of less than 0.02 Deg.

Daniels, Janet L.

Operation and performance of the OSSE instrument

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Arthur Holly Compton Gamma Ray Observatory is described. An overview of the operation and control of the instrument is given, together with a discussion of typical observing strategies used with OSSE and basic data types produced by the instrument. Some performance measures for the instrument are presented that were obtained from pre-launch and in-flight data. These include observing statistics, continuum and line sensitivity, and detector effective area and gain stability.

Cameron, R. A.

Accuracy of total ozone retrieval from NOAA SBUV/2 measurements: Impact of instrument performance

The National Oceanic and Atmospheric Administration/National Environmental Satellite Data and Information Service (NOAA/NESDIS) has been collecting and evaluating the solar backscattered ultraviolet (SBUV/2) instrument data from NOAA 9 and NOAA 11 spacecraft since March 1985. Over 5 years (March 1985 to October 1990) of NOAA 9 (version 5.0) and over 4 years (January 1989 to June 1993) of NOAA 11 (version 6.0) reprocessed data are now available to the scientific community to study geophysical phenomena involving ozone. This paper examines the impact of the instrument performance on total ozone retrieval from the two instruments. We estimate that at the end of October 1990 the total postlaunch error for NOAA 9 due to instrument alone is -2.2%. A significant fraction of this error (-1.9%) is due to diffuser degradation which is not accounted for in the version 5 reprocessing. The estimate for NOAA 11 total postlaunch instrument error, at the end of June 1993, is -0.4%.

Ahmad, Z.

Model Engine Performance Measurement From Force Balance Instrumentation

A large scale model representative of a low-noise, high bypass ratio turbofan engine was tested for acoustics and performance in the NASA Lewis 9- by 15-Foot Low-Speed Wind Tunnel. This test was part of NASA's continuing Advanced Subsonic Technology Noise Reduction Program. The low tip speed fan, nacelle, and an un-powered core passage (with core inlet guide vanes) were simulated. The fan blades and hub are mounted on a rotating thrust and torque balance. The nacelle, bypass duct stators, and core passage are attached to a six component force balance. The two balance forces, when corrected for internal pressure tares, measure the total thrust-minus-drag of the engine simulator. Corrected for scaling and other effects, it is basically the same force that the engine supports would feel, operating at similar conditions. A control volume is shown and discussed, identifying the various force components of the engine simulator thrust and definitions of net thrust. Several wind tunnel runs with nearly the same hardware installed are compared, to identify the repeatability of the measured thrust-minus-drag. Other wind tunnel runs, with hardware changes that affected fan performance, are compared to the baseline configuration, and the thrust and torque effects are shown. Finally, a thrust comparison between the force balance and nozzle gross thrust methods is shown, and both yield very similar results.

Jeracki, Robert J.

The Solar Orbiter SPICE Instrument An Extreme UV imaging spectrometer

Aims. The Spectral Imaging of the Coronal Environment (SPICE) instrument is a high-resolution imaging spectrometer operating at extreme ultraviolet wavelengths. In this paper, we present the concept, design, and pre-launch performance of this facility instrument on the ESA/NASA Solar Orbiter mission. Methods. The goal of this paper is to give prospective users a better understanding of the possible types of observations, the data acquisition, and the sources that contribute to the instrument’s signal. Results. The paper discusses the science objectives, with a focus on the SPICE-specific aspects, before presenting the instrument’s design, including optical, mechanical, thermal, and electronics aspects. This is followed by a characterisation and calibration of the instrument’s performance. The paper concludes with descriptions of the operations concept and data processing. Conclusions. The performance measurements of the various instrument parameters meet the requirements derived from the mission’s science objectives. The SPICE instrument is ready to perform measurements that will provide vital contributions to the scientific success of the Solar Orbiter mission.

M. Anderson

An evolution of X-ray astronomy instrumentation

This paper describes the growth of X-ray astronomy instrumentation from simple, single function, instruments performing survey measurements with crude spectral, spatial and temporal resolution to complex, multiple detector, instruments capable of observing selected phenomena and sources with extremely fine resolution. Examples of solar X-ray instrumentation that are discussed include OSO-IV, Apollo Telescope Mount and proposed Solar Maximum Mission instruments. Stellar X-ray instrumentation examples include UHURU, Astronomy Netherlands Satellite and HEAO-B instruments. Design details are provided and instrument parameters are compared to illustrate the evolutionary process.

Jagoda, N.

Flight motor set 360L007 (STS-33R)

Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane

Measurement of OH, H2SO4, MSA, NH3 and DMSO Aboard the NASA P-3B Aircraft

This project involved the installation of a downsized multichannel mass spectrometer instrument on the NASA P-3B aircraft and its subsequent use on the PEM-Tropics B mission. The new instrument performed well, measuring a number of difficult-to-measure compounds and providing much new photochemical and sulfur data as well as possibly uncovering a new nighttime DMSO source. The details of this effort are discussed.

Eisele, Fred

A Ground-Based Profiling Differential Absorption LIDAR System for Measuring CO2 in the Planetary Boundary Layer

Ground-based LIDAR observations can potentially provide continuous profiles of CO2 through the planetary boundary layer and into the free troposphere. We will present initial atmospheric measurements from a prototype system that is based on components developed by the telecommunications industry. Preliminary measurements and instrument performance calculations indicate that an optimized differential absorption LIDAR (DIAL) system will be capable of providing continuous hourly averaged profiles with 250m vertical resolution and better than 1 ppm precision at 1 km. Precision increases (decreases) at lower (higher) altitudes and is directly proportional to altitude resolution and acquisition time. Thus, precision can be improved if temporal or vertical resolution is sacrificed. Our approach measures absorption by CO2 of pulsed laser light at 1.6 microns backscattered from atmospheric aerosols. Aerosol concentrations in the planetary boundary layer are relatively high and are expected to provide adequate signal returns for the desired resolution. The long-term goal of the project is to develop a rugged, autonomous system using only commercially available components that can be replicated inexpensively for deployment in a monitoring network.

Andrews, Arlyn E.

Microwave radiometer for subsurface temperature measurement

A UHF radiometer, operating at a frequency of 800 MHz, was modified to provide an integral, three frequency voltage standing wave ratio (VSWR) circuit in the radio frequency (RF) head. The VSWR circuit provides readings of power transmission at the antenna-material interface with an accuracy of plus or minus 5 percent. The power transmission readings are numerically equal to the emissivity of the material under observation. Knowledge of material emissivity is useful in the interpretation of subsurface apparent temperatures obtained on phantom models of biological tissue. The emissivities of phantom models consisting of lean beefsteak were found to lie in the range 0.623 to 0.779, depending on moisture content. Radiometric measurements performed on instrumented phantoms showed that the radiometer was capable of sensing small temperature changes occurring at depths of at least 19 to 30 mm. This is consistent with previously generated data which showed that the radiometer could sense temperatures at a depth of 38 mm.

Porter, R. A.

Executive and communications services to support the IPAD environment

The principal purposes of the prototype executive software are to provide a system independent interface to the underlying host system and to allow for extension to full IPAD executive services as described in the preliminary design. A basic set of functions is included in the prototype to meet the requirements of the other components of the prototype, principally IPID, the IPAD data management system. The functions were chosen so that they would be readily built on any of the proposed host systems with minimal redesign and execution overhead. The functions fall into five categories: access to host data, access to data files, access to communication services, data transformation, and instrumentation for performance measurement. Communication services provide message delivery between processes in a network of heterogeneous computers. Data transformation services and communication services ensure data type validity and data integrity of messages exchanged between processes.

Tanner, J. G.

Surface finish measurement studies

The performance of stylus instruments for measuring the topography of National Transonic Facility (NTF) model surfaces both for monitoring during fabrication and as an absolute measurement of topography was evaluated. It was found that the shop-grade instruments can damage the surface of models and that their use for monitoring fabrication procedures can lead to surface finishes that are substantially out of range in critical areas of the leading edges. The development of a prototype light-scattering instrument which would allow for rapid assessment of the surface finish of a model is also discussed.

Teague, E. C.

CCD camera system for cometary research

The objective is to upgrade the NASA/GSFC 36 inch telescope instrumentation, primarily with a new charge coupled device (CCD) camera system, to permit an effective monitoring program of cometary activity by means of narrowband imaging and spectroscopic techniques. Researchers have twice taken delivery of the CCD camera system from Princeton Scientific Instruments and twice returned it within six weeks for repair. During the times they had the camera system in the lab, they measured the instrumental performance of the TEK 512 x 512 CCD chip (e.g., readout noise, dark current, etc) and developed the complete operational software for the camera system plus several useful observing and data reduction routines for use at the telescope. The CCD camera system is controlled by an IBM-AT computer. The peripheral equipment and software to permit the efficient transfer of large amounts of data to the LASP's computers (VAXs) and subsequent timely reductions are also in place. The Io torus (S II) emission was monitored with a Fabry-Perot scanning spectrometer, in conjunction with the International Jupiter Watch. The CCD camera system will be coupled to a narrowband interference filter imager and a long-slit spectrograph to provide regular and well-calibrated spatial and spectral observations of comets.

Oliversen, R. J.

A technique for improving the calibration of large-area sphere sources

A new technique for improving the accuracy of radiance calibrations for large-area integrating-sphere sources has been investigated. Such sources are used to calibrate numerous aircraft and spacecraft remote sensing instruments. Recent measurements performed at NIST and NASA Goddard Space Flight Center have demonstrated that the uncertainty of sphere-source radiance measurements can be improved from the present 5 to 10 percent level to a 1 to 2 percent level. Silicon detectors with bandpass filters mounted in front of them and calibrated for absolute spectral responsivity can be used to confirm and to monitor the absolute radiance of a sphere source.

Walker, James H.

Statistical Process Control and Capability Study on the Water Content Measurements in NASA Glenn's Icing Research Tunnel

The Icing Research Tunnel (IRT) at NASA Glenn Research Center follows the recommended practice for icing tunnel calibration outlined in SAE's ARP5905 document. The calibration team has followed the schedule of a full calibration every five years with a check calibration done every six months following. The liquid water content of the IRT has maintained stability within in the specifications presented to customers that the variation is within +/- 10% of the calibrated, target measurement. With recent measurements and instrumentation errors, a more thorough assessment of error source was desired. By constructing statistical process control charts, the ability to determine how the instrument varies in the short term, mid term, and long term was gained. The control charts offer a view of instrument error, facility error, or installation changes. It was discovered that there was a shift from target to mean baseline thus leading to the study of the overall capability indices of the liquid water content measuring instrument to perform within specifications defined in the IRT. This presentation describes data processing procedures for the Multi-Element Sensor in the IRT, including collision efficiency corrections, canonical correlation analysis, Chauvenet's Criterion for rejection of data, distribution check of data, and mean, median and mode for construction of control charts. Further data is presented to describe the repeatability of the IRT with the Multi-Element Sensor and the ability to maintain a stable process for the defined calibration schedule.

Timko, Emily N.