Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFERENCE GRATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Josephson junction interference grating.

The maximum current through multiple Josephson structures as a function of applied magnetic field is presented. Particular emphasis is placed on the Josephson penetration depth effects and geometrical considerations. The symmetrical and asymmetrical current feed two-, three-, four-, and five-junction gratings are analyzed and discussed. The Josephson penetration depth is shown to control the amplitude of the interference and diffraction patterns of the interference grating. In addition the interior-junction-length/interference-loop-area product is shown to control the operating mode of the interference grating. The dependence of the magnetic field sensitivity and interference pattern amplitude on the number of junctions is discussed.

Stuehm, D. L.↗

Real time pre-detection dynamic range compression

A real time, pre-detection optical dynamic range compression system uses a photorefractive crystal, such as BaTiO3 or LiNbO3, in which light induced scattering from crystal inhomogeneities of the optical input occurs as a nonlinear function of the input intensity. The greater the intensity, the faster random interference gratings are created to scatter the incident light. The unscattered portion of the optical signal is therefore reduced in dynamic range over time. The amount or range of dynamic range compression may be controlled by adjusting the time of application of the unscattered crystal output to the photodetector with regard to the time of application of the optical input to the crystal.

Liu, Hua-Kuang↗

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike↗

Fabrication of optical reflecting diffraction gratings by light-interference phenomenon

Features of technique: major reduction in cost of fabrication; gratings exhibit low stray or scattered radiation, improve signal noise ratio, and eliminate false spectral-lines; gratings can be fabricated free of optical aberrations, with high groove frequencies, and on practically any surface geometry; and fabrication time has been reduced.

Caruso, A. J.↗

Optically-Tuned Far-Infrared Device

Spacing of visible interference pattern determines frequency of infrared radiation. Variable photoconductivity grating formed by interference of two visible laser beams intersecting on surface of proposed AlGaAs device substituted for fixed metal grating. Proposed device provides higher output-power density and greater tunability.

Katz, Joseph↗

Coherent gradient sensing method and system for measuring surface curvature

A system and method for determining a curvature of a specularly reflective surface based on optical interference. Two optical gratings are used to produce a spatial displacement in an interference field of two different diffraction components produced by one grating from different diffraction components produced by another grating. Thus, the curvature of the surface can be determined.

Rosakis, Ares J.↗

Single-shot magnon interference in a magnon-superconducting-resonator hybrid circuit

Magnon interference is a hallmark of coherent magnon interactions. In this work, we demonstrate single-shot magnon interference using up to four magnon pulses in two remotely coupled yttrium iron garnet spheres mediated by a coplanar superconducting resonator. By exciting one YIG sphere with injected microwave pulses, we achieve coherent energy exchange between the two spheres, facilitating their interference processes, including Rabi-like oscillation with a single pulse, constructive and destructive interference with two pulses, and interference peak sharpening with up to four pulses—analogous to diffraction grating in optical interference. The resulting interference patterns can be precisely controlled by changing the frequency detuning and time delay of the magnon pulses. The demonstration of time-domain coherent control of remote magnon interference opens new pathways for advancing coherent information processing through multi-operation, circuit-integrated hybrid magnonic networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of dynamic theory to describe experimental results from volume holography

The general applicability of dynamic theory to the description of the recording and readout characteristics of volume (thick) hologram gratings is indicated. In dynamic theory (as opposed to static theory), the volume nature of the thick holographic grating allows the interference of an incident light beam with its own diffracted beam inside the recording medium. This effect causes the continuous recording of another grating that alters the initial one, producing a resultant grating that is not uniform through the thickness of the recording material and a grating whose writing and reading characteristics may vary dramatically, depending on the recording material and the experimental conditions. A large number of diverse types of writing, reading, and angular-selectivity behavior have been reported. The dynamic theory of thick-hologram writing and reading is shown to predict qualitatively all of these various types of experimental behavior.

Magnusson, R.↗

Transient Relativistic Plasma Grating to Tailor High-Power Laser Fields, Wakefield Plasma Waves, and Electron Injection

In this work, we show the first experiment of a transverse laser interference for electron injection into the laser plasma accelerators. Simulations show such an injection is different from previous methods, as electrons are trapped into later acceleration buckets other than the leading ones. With optimal plasma tapering, the dephasing limit of such unprecedented electron beams could be potentially increased by an order of magnitude. In simulations, the interference drives a relativistic plasma grating, which triggers the splitting of relativistic-intensity laser pulses and wakefield. Consequently, spatially dual electron beams are accelerated, as also confirmed by the experiment.

43 PARTICLE ACCELERATORS↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Colliding Pulse Mode Locking and Nonequilibrium Carrier Dynamics within Vertical External-Cavity Surface-Emitting Lasers

The complex nonlinear dynamics of colliding counterpropagating ultrashort laser pulses circulating in a vertical external-cavity surface-emitting ring laser cavity are captured by a first-principles quantum-mechanical microscopic model coupled to an intracavity beam propagator. Furthermore, our numerical simulations establish that overall mode locking stability is sensitive to relative phases and delays of the pulses impinging on the semiconductor saturable absorber mirror. Delay offsets of the counterpropagating pulses lead to asymmetric carrier recovery and instability, often leading in turn to single unidirectional circulating pulses. Although computationally challenging, we also include transverse effects and show that the influence of interference patterns from spatial gratings written by the counterpropagating pulses is significant in stabilizing the modelocked pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved photoionization mass spectrometer

Improved spectrometer for gas analysis lessens the intensity problem that occurs in obtaining dispersed ultraviolet radiation. A filter, consisting of a selectively transmitting gas cell, a thin film or mirror, or a predispersing grating, alleviates problems of interference from higher-order spectral lines and from scattered ultraviolet light.

Poshchenrieder, W. P.↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗