Search NASASearch

SEARCH · Search NASA

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.

Shock compression of FeOOH and implications for iron-water interactions in super-earth magma oceans

Iron(Fe)-water reactions in a magma ocean can influence water storage and density of planets. These reactions can form Fe-O-H phases, whose density, melting, and electronic properties at planetary interior conditions are important for informing planetary models. Here, we study natural goethite (α-FeOOH) that is shock-compressed along its principal Hugoniot. Analysis of our velocity interferometer system for any reflector (VISAR) results extends the equation of state to over 800 GPa. X-ray diffraction and VISAR reflectivity results indicate the onset of melting occurs at ~95 GPa with complete melting by 166 GPa, which may be relevant to low seismic velocity anomalies observed above the core-mantle boundary. Analysis of X-ray emission spectroscopy results up to 285 GPa shows the spin crossover of Fe, with dominantly low spin Fe above ~265 GPa in the melt, supporting formation of dense basal magma oceans in terrestrial planets. Using our measured FeOOH densities, we model planetary interiors up to 10 Earth masses. Assuming FeOOH forms via iron-water reactions, the radius decreases by up to 28%, while the density increases by up to 165% compared to the unreacted cases, providing an avenue to investigate water storage and evolution in super-Earths and sub-Neptunes.

Zhang, Yanyao [Stanford Univ., CA (United States)]

Shock compression of crystalline TeO 2 to the high-pressure fluid regime: Insights from ab initio molecular dynamics simulations

The shock response of fully-dense and porous crystalline tellurium dioxide (TeO 2 ⁠) to the high-pressure and high-temperature fluid regime was investigated within the framework of density functional theory with Mermin’s generalization to finite temperatures. The principal and porous shock Hugoniot curves were predicted from canonical ab initio molecular dynamics (AIMD) simulations, with the phase space sampled along isotherms up to 80 000 K, for densities ranging from ρ = 3 to 17 g/cm 3 . The polymorphs investigated are α-TeO 2 paratellurite (⁠P4 1 2 1 2), TeO 2 cotunnite (⁠Pnma⁠), and TeO 2 post-cotunnite (⁠P2 1 /m⁠). Based on the discontinuity found in the calculated U s – u p slope of TeO 2 post-cotunnite at a shock velocity of U s ≃ 8.35km/s and a particle velocity of u p ≃ 3.64 km/s, the shock melting temperature and pressure are predicted to be ≃ 6500 K and ≃ 170 GPa. Results from the AIMD simulations are in line with the static compression data of TeO 2 paratellurite and cotunnite, and with the recent shock Hugoniot data for single-crystal α- TeO 2 for pressures up to 85 GPa, obtained using the inclined-mirror method and the velocity interferometer system for any reflector combined with powder gun and two-stage light-gas gun.

74 ATOMIC AND MOLECULAR PHYSICS

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION

Shock propagation in aerogel and TPP foams for inertial fusion energy target design

Achieving practical inertial fusion energy (IFE) requires the development of target designs with well-characterized microstructure and compression response. We measured shock dynamics in low-density (17.5–500 mg/cm 3 ) aerogel and two-photon polymerization (TPP) foams using x-ray phase contrast imaging (XPCI) methods and the Velocity Interferometer System for Any Reflector. By analyzing shock front evolution, we examined how target type and density influence shock propagation and energy dissipation. Talbot-XPCI shows that aerogels support a smooth, bowed shock front due to their homogeneous nanometer-scale pore network. In contrast, TPP foams exhibit irregular, stepwise propagation driven by interactions with their periodic micrometer-scale lattice. Shock velocity follows a power-law relation: aerogels deviate from classical ρ −1/2 scaling due to pore-collapse dissipation, while TPP foams follow the trend with larger uncertainties from density variations. Comparisons with xRAGE simulations reveal systematic underestimation of shock speeds. These results provide the first experimental constraints on shock propagation in TPP foams over a wide density range and highlight the influence of internal structure on anisotropic shock behavior. Our findings support improved benchmarking of EOS and hydrodynamic models and inform the design of foam architectures that promote implosion symmetry in IFE capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Optimization of VISAR Mirrors for NIF Targets

The velocity interferometer system for any reflector (VISAR) is a key diagnostic at the National Ignition Facility that is used for measuring propagation and velocities of shocks through a sample for several high energy density campaigns. To support simultaneous measurements with VISAR and other diagnostics, optical mirrors are used to divert the VISAR signal off axis from the primary diagnostic line of sight, which can then be used for other measurements. Here, in this study, we describe our work on investigating issues with these mirrors to support complex new target geometries and signal variance due to system aging and more demanding polling rates. This paper also describes the key mitigation efforts performed to improve both the flatness and reflectivity of these commonly used mirrors.

National Ignition Facility

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]

Real-Time GPU-Accelerated OFDR With an Integrated Auxiliary Interferometer

A GPU-accelerated optical frequency domain reflectometry (OFDR) system with an improved integrated auxiliary interferometer is proposed. Unlike conventional approaches that require separate auxiliary interferometers and multiple detection channels, the proposed OFDR system embeds this functionality directly into the signal via an intentional beat component. This enables self-calibration of laser nonlinearity while maintaining a cost-effective hardware configuration. Building on this simplified configuration, the system leverages GPU acceleration with an NVIDIA RTX 4070 Ti to achieve real-time performance, delivering high-throughput signal processing for continuous OFDR interrogation. The signal processing pipeline comprises signal capture, resampling for nonlinearity compensation, and frequency shift computation, all optimized for parallel execution. Hardware benchmarking demonstrates substantial acceleration over CPU implementations, achieving up to a 45× speedup for resampling and frequency shift computations and enabling processing latencies below 30 ms. Thermal response validation is conducted under two complementary scenarios: localized heating using a water bath and cryogenic-temperature conditions using liquid nitrogen. Under localized heating, the system achieves an accuracy of 0.249 °C with a thermal sensitivity of 5.971 GHz/°C, while cryogenic-temperature validation demonstrates a frequency shift response with a sensitivity of 2.383 GHz/°C and an accuracy of 2.04 °C. The high acceleration of the proposed GPU-accelerated OFDR system and its accuracy are achieved by exploiting CUDA-based stride indexing, enabling efficient parallel segmentation and processing of large datasets without additional memory copies. The benchmarking results confirm the robustness, accuracy, and deployability of the proposed OFDR system across a wide temperature range, establishing it as a practical platform for real-time distributed fiber sensing in structurally dynamic environments.

Harb, Salah [Lawrence Berkeley National Laboratory

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors

Dissipation Enables Strongly Detuning-Dependent Interference in Pulsed Dynamical Decoupling

One of the defining features of pulsed dynamical decoupling is its suppression of a driven qubit's sensitivity to static detuning errors between the drive field and qubit resonance. In this paper, we show that dissipation, in the form of excited-state decay, can change this behavior entirely, producing an interference signal with a strong detuning dependence. This signal arises from decay during driven evolution and relies on coherence retained by the qubit after such a decay event. We develop analytical and numerical models that capture the underlying mechanism and observe this same dissipation-induced detuning dependence experimentally in both a free-space strontium atom interferometer and a superconducting transmon qubit system. We also use this dissipation-induced detuning dependence as the basis for a new spectroscopic technique called Dissipative Carr-Purcell Spectroscopy (DCPS) and compare it with a traditional Ramsey sequence. Our results establish a regime of pulsed dynamical decoupling in which dissipation reshapes, rather than merely degrades, coherent control, and we expect these dynamics to be relevant to a wide range of quantum systems.

DeRose, Kenneth [Northwestern U.; Fermilab] (ORCID

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION

Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D

Real-time and adaptive plasma control is crucial for robust tokamak operation, requiring sensitivity and tolerance measurements of the plasma state. This paper presents the implementation of an integrated real-time plasma monitoring framework on the DIII-D tokamak to support advanced control approaches, including machine-learning (ML) methods. The system is built on the SHIELD framework, a high-performance modular architecture that provides a unified pipeline for integrating diverse diagnostics. The framework leverages high-bandwidth digitizers, fast numerical processing, and deterministic, low-latency interconnects to stream high-fidelity data from diagnostics such as electron cyclotron emission (ECE), beam emission spectroscopy (BES), CO interferometers, and a visible tangential divertor camera (TangTV). The system’s validity is demonstrated through direct comparisons of real-time and offline data. Furthermore, we present two key applications of the developed plasma monitoring system with ML-based plasma control strategies, including real-time divertor detachment and active Alfvén Eigenmode control. As a result, this work presents a robust and scalable approach for integrating high-frequency, multidimensional diagnostics into advanced control algorithms for future fusion devices.

AI/ML

Real-time reconstruction and control of pedestal-top electron density using RMP and gas puff at KSTAR

We report the experimental results of controlling the pedestal-top electron density by applying resonant magnetic perturbation (RMP) with in-vessel control coils and the main gas puff in the 2024-2025 KSTAR experimental campaign. The density is reconstructed using a parameterized $ψ_N$ grid and five channels of line-averaged density measured by the two-colored interferometer (TCI). The reconstruction procedure is accelerated by deploying a multi-layer perceptron to run in approximately 120 µ s and is sufficiently fast for real-time control. A proportional-integral controller was adopted, with the controller gains estimated from the system identification procedure. The experimental results demonstrate that the developed controller can follow a dynamic target while exclusively using both actuators. The absolute percentage errors between the electron density at $ψ_N$ = 0.89 and the target were approximately 1.5% median and a 2.5% average, respectively. The developed controller can even lower the density by using the pump-out mechanism under RMP, and it can follow a more dynamic range of density targets than a single actuator controller. The developed controller will enable experimental scenario exploration within a shot by dynamically setting the density target or maintaining a constant electron density within a discharge.

EFIT

Development of magnetic field monitoring system for the MAGIS-100 experiment

The MAGIS-100 collaboration is building a long-baseline atom interferometer designed to investigate dark matter, novel forces, gravitational waves, and quantum science. A major design challenge is external, time-varying magnetic fields, the effect of which can mimic gravitational waves or expected dark matter signals. Several mitigations will be enacted, including mu-metal shielding and a suite of magnetometers. This presentation will discuss the development of a magnetic field monitoring system based on commercial magneto-inductive sensors to be installed at several points along the interferometer.

Arce, Edwin [Unlisted; Fermilab]