Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°–10° to 1°–2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear interferometer systems and methods

Nonlinear interferometers include a nonlinear optical medium that is situated to produce a conjugate optical beam in response to a pump beam and a probe beam. The pump, probe, and conjugate beams propagate displaced from each other along a common optical path. One of the beams is selectively phase shifted, and the beams are then returned to the nonlinear medium, with the selectively phase shift beam phase shifted again. The nonlinear medium provides phase sensitive gain to at least one of the probe or conjugate beams, and the amplified beam is detected to provide an estimate of the phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.

47 OTHER INSTRUMENTATION↗

A phase contrast imaging–interferometer system for detection of multiscale electron density fluctuations on DIII-D

Heterodyne interferometry and phase contrast imaging (PCI) are robust, mature techniques for measuring low-k and high-k electron density fluctuations, respectively. This work describes the first-ever implementation of a combined PCI–interferometer. The combined system uses a single 10.6 μm probe beam, two interference schemes, and two detectors to measure electron density fluctuations at large spatiotemporal bandwidth (10 kHz <f < 5 MHz and 0 cm{sup -1} ≤k ≤ 20 cm{sup -1}), allowing simultaneous measurement of ion- and electron-scale instabilities. Further, correlating our interferometer’s measurements with those from DIII-D’s pre-existing, toroidally separated interferometer allows core-localized, low-n MHD studies that may otherwise be inaccessible via external magnetic measurements. The combined diagnostic’s small port requirements and minimal access restrictions make it well-suited to the harsh neutron environments and limited port space expected in next-step devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)

In this work, a novel combined diagnostic capable of measuring multiscale density fluctuations that extend from magnetohydrodynamic (MHD) to the lower range of electron temperature gradient turbulence has been designed, installed, and operated at DIII-D. The combined diagnostic was constructed by adding a heterodyne interferometer to the pre-existing phase contrast imaging (PCI) system, both of which measure line-integrated electron density fluctuations. The port-space footprint is minimized via use of a single 10.6 μm probe beam. With temporal bandwidths in excess of 1 MHz, the PCI measures high-k (1.5 cm -1 < |k R | ≤ 25 cm -1 ) fluctuations with sensitivity 3×10 13 m -2 /$\sqrt{kHz}$, while the interferometer simultaneously measures low-k (|k R | < 5 cm -1 ) fluctuations with sensitivity 3×10 14 m -2 /$\sqrt{kHz}$. The intentional mid-k overlap has been empirically verified with sound-wave calibrations and allows quantitative investigation of multiscale effects that are predicted to be significant in the reactor-relevant T e ~ T i regime. Lastly, via correlation with the primary DIII-D interferometer, the toroidal mode numbers of core-localized MHD can be measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor system that uses embedded optical fibers

Sensor systems including an interferometer system are disclosed herein. In a general embodiment, the sensor system includes an optical fiber that is embedded into a sample, where the optical fiber has a reflective tip. The optical fiber is optically coupled to a sensor and a detector of the laser interferometer system. The sensor system further includes a computing device or circuit that is configured to receive electrical signals generated by the detector. The laser source is configured to emit light, which is coupled into the optical fiber. The light travels through the optical fiber until the light reaches the reflective tip, where it is reflected back through the optical fiber. The detector is impacted by the reflected light, and generates an electrical signal based upon the reflected light. The computing device generates a value that is indicative of a behavior of the sample based upon the electrical signal.

Chavez, Marcus Alexander↗

An upgraded interferometer-polarimeter system for broadband fluctuation measurements

Measuring high-frequency fluctuations (above tearing mode frequencies) is important for diagnosing instabilities and transport phenomena. The Madison Symmetric Torus interferometer-polarimeter system has been upgraded to utilize improved planar-diode mixer technology. The new mixers reduce phase noise and allow more sensitive measurements of fluctuations at high frequency. Typical polarimeter rms phase noise values of 0.05°–0.07° are obtained with 400 kHz bandwidth. The low phase noise enables the resolution of fluctuations up to 250 kHz for polarimetry and 600 kHz for interferometry. The importance of probe beam alignment for polarimetry is also verified; previously reported tolerances of ≤0.1 mm displacement for equilibrium and tearing mode measurements minimize contamination due to spatial misalignment to within acceptable levels for chords near the magnetic axis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design of a line velocity interferometer for any reflector for inertial confinement experiments on the Z-machine

A line VISAR (Velocity Interferometer System for Any Reflector) has been designed and commissioned at the Sandia National Laboratory’s Z-machine. The instrument consists of an F/2 collection system, beam transport, and an interferometer table that contains two Mach–Zehnder type interferometers and an eight channel Gated Optical Imaging (GOI) system. The VISAR probe laser operates at the 532 nm wavelength, and the GOI bandpass is 540–600 nm. The output of each interferometer is passed to an optical streak camera with four selectable sweep speeds. The system is designed with three interchangeable optics modules to select a full field of view of 1 mm, 2 mm, or 4 mm. The optical beam transport system connects the target image plane to the interferometers and the gated optical imagers. The target is integrated into a sacrificial final optics assembly that is integral to the transport beamline.

Datte, P.↗

Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX

A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. Furthermore, to study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ghost fringe removal techniques using Lissajous data presentation

A VISAR (Velocity Interferometer System for Any Reflector) is a Dopplervelocity interferometer which is an important optical diagnostic in shockwave experiments at the national laboratories, used to measureequation of state(EOS) of materials under extreme conditions. Unwanted reflection of laser light from target windows can produce an additional component to the VISAR fringe record that can distort and obscure the true velocity signal. When accurately removing this so-called ghost artifact component is essential for achieving high accuracy EOSmeasurements, especially when the true light signal is only weakly reflected from the shock front. Independent of the choice of algorithm for processing the raw data into a complex fringe signal, we have found it beneficial to plot this signal as a Lissajous and seek the proper center of this path, even under time varying intensity which can shift the perceived center. Moreover, the ghost contribution is then solved by a simple translation in the complex plane that recenters the Lissajous path. For continuous velocity histories, we find that plotting the fringe magnitude vs nonfringing intensity and optimizing linearity is an invaluable tool for determining accurate ghost offsets. For discontinuous velocity histories, we have developed graphically inspired methods which relate the results of two VISARs having different velocity per fringe proportionalities or assumptions of constant fringe magnitude to find the ghost offset. The technique can also remove window reflection artifacts in generic interferometers, such as in the metrology of surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗