Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERNAL CONVERSION RADIOISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of Neutron-Induced Fission Cross Sections of U, Am, and Cm at n{sub T}OF

Neutron induced fission cross sections of several isotopes have been measured at the CERN n{sub T}OF spallation neutron facility. Between them some measurements involve isotopes ({sup 233}U, {sup 241}Am, {sup 243}Am, {sup 245}Cm) relevant for applications to nuclear technologies. The n{sub T}OF facility delivers neutrons with high instantaneous flux and in a wide energy range, from thermal up to 250 MeV. The experimental apparatus consists of an ionization chamber that discriminates fission fragments and {alpha} particles coming from natural radioactivity of the samples. All the measurements were performed referring to the standard cross section of {sup 235}U.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-induced fission cross section of {sup 234}U and {sup 237}Np measured at the CERN Neutron Time-of-Flight (n{sub T}OF) facility

A high-resolution measurement of the neutron-induced fission cross section of {sup 234}U and {sup 237}Np has been performed at the CERN Neutron Time-of-Flight facility. The cross sections have been determined in a wide energy range from 1 eV to 1 GeV using the evaluated {sup 235}U cross section as reference. In these measurements the energy determination for the {sup 234}U resonances could be improved, whereas previous discrepancies for the {sup 237}Np resonances were confirmed. New cross-section data are provided for high neutron energies that go beyond the limits of prior evaluations, obtaining important differences in the case of {sup 237}Np.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The {sup 237}Np(n,f) cross section at the CERN n-TOF facility

The {sup 237}Np(n,f) cross sections have been measured at the n-TOF facility relative to the {sup 235}U and {sup 238}U fission cross sections. The n-TOF spallation neutron source at CERN is characterized by a high intensity flux, an excellent time resolution and an extensive neutron energy range (from eV to GeV). A fast ionization chamber was used as a fission fragment detector with efficiency better than 97%. Preliminary {sup 237}Np(n,f) cross sections have been deduced in the energy range from 20 keV to 10 MeV and are found in good agreement with data from literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Endovascular Brachytherapy in the Femoropopliteal Segment Using {sup 192}Ir and {sup 188}Re

This report presents a review of the literature on endovascular brachytherapy (EVBT) after percutaneous transluminal angioplasty (PTA) in the femoropopliteal segment. We summarize the pathophysiological changes induced by PTA and EVBT within the vessel wall, technical considerations regarding various radiation sources and their application, the impact of stents on the radial dose profile, recommendations for dosimetry of beta and gamma sources, results of experimental and clinical trials, and the medication required before, during, and after EVBT. We aim to help to identify patients who are eligible for EVBT, to choose an appropriate technical approach, and to initiate adequate antiplatelet and anticoagulant therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postlumpectomy Focal Brachytherapy for Simultaneous Treatment of Surgical Cavity and Draining Lymph Nodes

Purpose: The primary objective was to investigate a novel focal brachytherapy technique using lipid nanoparticle (liposome)-carried {beta}-emitting radionuclides (rhenium-186 [{sup 186}Re]/rhenium-188 [{sup 188}Re]) to simultaneously treat the postlumpectomy surgical cavity and draining lymph nodes. Methods and Materials: Cumulative activity distributions in the lumpectomy cavity and lymph nodes were extrapolated from small animal imaging and human lymphoscintigraphy data. Absorbed dose calculations were performed for lumpectomy cavities with spherical and ellipsoidal shapes and lymph nodes within human subjects by use of the dose point kernel convolution method. Results: Dose calculations showed that therapeutic dose levels within the lumpectomy cavity wall can cover 2- and 5-mm depths for {sup 186}Re and {sup 188}Re liposomes, respectively. The absorbed doses at 1 cm sharply decreased to only 1.3% to 3.7% of the doses at 2 mm for {sup 186}Re liposomes and 5 mm for {sup 188}Re liposomes. Concurrently, the draining sentinel lymph nodes would receive a high focal therapeutic absorbed dose, whereas the average dose to 1 cm of surrounding tissue received less than 1% of that within the nodes. Conclusions: Focal brachytherapy by use of {sup 186}Re/{sup 188}Re liposomes was theoretically shown to be capable of simultaneously treating the lumpectomy cavity wall and draining sentinel lymph nodes with high absorbed doses while significantly lowering dose to surrounding healthy tissue. In turn, this allows for dose escalation to regions of higher probability of containing residual tumor cells after lumpectomy while reducing normal tissue complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Pneumopathy in the Rat After Intravenous Application of {sup 188}Re-Labeled Microspheres

Purpose: To determine the dose dependence and kinetics of pneumopathy after systemic administration of rhenium-188 ({sup 188}Re)-labeled microspheres in a rat model. Methods and Materials: {sup 188}Re-microspheres were injected intravenously into adult Wistar rats (n = 54, age, 8 {+-} 2 months). The rats were divided into 6 groups according to the intended absorbed dose in the lung (maximum 60 Gy). Gamma camera scans were used to estimate the individual whole lung doses. One control group (n = 5) received nonlabeled microspheres. The breathing rate was measured before and weekly after the treatment using whole body plethysmography until 24 weeks. An increase in the breathing rate by 20% compared with the individual pretreatment control value was defined as the quantal endpoint for dose-effect analyses. Results: A biphasic increase in the breathing rate was observed. The first impairment of lung function occurred in Weeks 3-6. For late changes, the interval to onset was clearly dose dependent and was 17 weeks (10-30 Gy) and 10 weeks (50-60 Gy), respectively. The incidence of the response was highly dependent on the estimated lung dose. The median effective dose for an early and late response was virtually identical (19.9 {+-} 0.6 Gy and 20.4 {+-} 3.1 Gy, respectively). A significant correlation was found between the occurrence of an early and a late effect in the same rat, suggesting a strong consequential component. Conclusions: The effects of radiolabeled microspheres can be studied longitudinally in a rat model, using changes in the breathing rate as the functional, clinically relevant response. The isoeffective doses from the present study using radionuclide administration and those from published investigations of homogeneous external beam radiotherapy are almost similar.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Data Sheets for A = 207

Evaluated nuclear structure and decay data for all nuclei within the A=207 mass chain are presented. The experimental data are evaluated and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities, and other nuclear properties are recommended. Inconsistencies and discrepancies that exist in the literature are noted. This work supersedes the earlier evaluation by M.J. Martin (1993Ma73), published in Nuclear Data Sheets70, 315 (1993).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of laser irradiation of nanoparticles in aqueous uranium salt solutions on nuclide activity

This paper presents an experimental study of the effect of laser irradiation of aqueous uranyl chloride solutions containing gold nanoparticles on the activity of the uranium series radionuclides {sup 234}Th, {sup 234m}Pa, and {sup 235}U. The solutions were exposed to femtosecond Ti:sapphire laser pulses and to the second or third harmonic of a Nd:YAG laser (150-ps pulses) at a peak intensity in the medium of {approx}10{sup 12} W cm{sup -2}. The activities of the radionuclides in the irradiated solutions were shown to differ markedly from their equilibrium values. The sign of the deviation depends on the laser wavelength. The measured activity deviations can be interpreted as evidence that laser exposure of nanoparticles accelerates the alpha and beta decays of the radionuclides. The observed effects are accounted for in terms of a mechanism that involves resonant enhancement of optical waves by metallic nanoparticles. (interaction of laser radiation with matter)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{sup 196}Hg and the 'magical quartet' of the extended U{sub {nu}}(6/12) x U{sub {pi}}(6/4) supersymmetry

We present the results of a {gamma}{gamma} angular correlation experiment investigating the nucleus {sup 196}Hg and compare these with a theoretical description of {sup 196}Hg within the U{sub {nu}}(6/12) x U{sub {pi}}(6/4) extended supersymmetry. To populate excited {sup 196}Hg states, we used the Cologne FN Tandem accelerator inducing the reaction {sup 194}Pt({alpha},2n){sup 196}Hg and analyzed the {gamma} decays of levels up to an excitation energy of 2.4 MeV with the HORUS cube spectrometer. The new results on this mercury isotope allow a comparison between the experimental data and the supersymmetrical predictions and show good agreement. This way we can add {sup 196}Hg as a fifth supermultiplet member to the so-called magical quartet consisting of {sup 194,195}Pt and {sup 195,196}Au.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conclusive evidence of quasifission in reactions forming the {sup 210}Rn compound nucleus

Fission fragment mass ratio distributions have been measured for the reactions {sup 16}O+{sup 194}Pt and {sup 24}Mg+{sup 186}W, both leading to the same compound nucleus, {sup 210}Rn, at near-barrier energies. The measured fission fragment mass ratio variances for {sup 16}O+{sup 194}Pt and {sup 24}Mg+{sup 186}W are compared with the calculations assuming compound nucleus formation. Mass variances of fragments from the {sup 24}Mg+{sup 186}W reaction show a dramatic deviation from the compound nucleus behavior. This suggests strong evidence for onset of the quasifission process in this reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of the {pi}h{sub 11/2} band in the stable nucleus {sup 193}Ir

Excited states in the stable nucleus {sup 193}Ir have been investigated through an in-beam {gamma}-ray spectroscopic technique following the {sup 192}Os({sup 7}Li, {alpha}2n) reaction at a beam energy of 44 MeV. A level scheme built on the {pi}h{sub 11/2} isomer has been extended to high-spin states using eleven newly observed {gamma} transitions. The {pi}h{sub 11/2} band is proposed to be formed by coupling an h{sub 11/2} proton to a core with large triaxial deformation. Three-quasiparticle states are suggested in {sup 193}Ir on referring to the similar states in {sup 187}Ir. The features of signature splitting in the {pi}h{sub 11/2} bands of {sup 187-193}Ir are discussed with the help of total Routhian surface calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of Highly Excited Long-Lived Isomers in Neutron-Rich Hafnium and Tantalum Isotopes through Direct Mass Measurements

A study of cooled {sup 197}Au projectile-fragmentation products has been performed with a storage ring. This has enabled metastable nuclear excitations with energies up to 3 MeV, and half-lives extending to minutes or longer, to be identified in the neutron-rich nuclides {sup 183,184,186}Hf and {sup 186,187}Ta. The results support the prediction of a strongly favored isomer region near neutron number 116.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fully self-consistent calculations of nuclear Schiff moments

We calculate the Schiff moments of the nuclei {sup 199}Hg and {sup 211}Rn in completely self-consistent odd-nucleus mean-field theory by modifying the Hartree-Fock-Bogoliubov code hfodd. We allow for arbitrary shape deformation and include the effects of nucleon dipole moments alongside those of a pion-exchange nucleon-nucleon interaction that violates charge-parity (CP) symmetry. The results for {sup 199}Hg differ significantly from those of previous calculations when the CP-violating interaction is of isovector character.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Rhenium-188, Gemcitabine, and 5-Fluorouracil on Cholangiocellular Carcinoma Cells: An In Vitro Study

The purpose of this study was to compare the beneficial effects of radioactive stents and radioactive stents plus additional chemotherapy in the palliative treatment of cholangiocellular carcinomas. Cholangiocellular carcinoma cells (TFK-1 cells) were treated either with 8 Gy (RTB group) or 16 Gy (RTA group) {sup 188}Re or with {sup 188}Re irradiation (8 Gy) combined with either gemcitabine (8 Gy/Gem) or 5-fluorouracil (8 Gy/5-FU) at a dosage of 20 {mu}g/ml medium for 4 days and subsequently compared with an untreated control group. Proliferation kinetics were assessed on days 4, 7, 11, 18, 25, and 32. Colony formation assays were performed on days 7, 18, and 32 and cell cycle distribution was examined on days 4, 7, 11, 15, 25, and 39. Cell proliferation kinetics showed the lowest cell numbers in the 8 Gy/5-FU group (control, 15,390,000; RTA group, 8,394,000; RTB group, 5,609,000; 8 Gy/Gem group, 423,000; and 8 Gy/5-FU group, 297,667). In contrast, clonogenic activity on day 32 was lower in the 8 Gy/Gem group (control, 29.3 colonies; RTB group, 23.1 colonies; 8 Gy/5-FU group, 21.5 colonies; 8 Gy/Gem, 3.3 colonies; and even augmented in the RTA group, with 37.7 colonies). Cell cycle distribution showed similar curves for all groups on slightly different levels except for the 8 Gy/5-FU group, which showed a relatively augmented percentage of cells on day 7 in the G2 M cycle phase and on day 4 in the S phase. In conclusion, irradiation (8 Gy) with {sup 188}Re administered, e.g., via coated stents, combined with Gem could be a valid option for the treatment of CCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Scatter Contribution and Distance Error by Iterative Methods for Strength Determination of HDR {sup 192}Ir Brachytherapy Source

High-dose rate (HDR) {sup 192}Ir brachytherapy sources are commonly used for management of malignancies by brachytherapy applications. Measurement of source strength at the hospital is an important dosimetry requirement. The use of 0.6-cm{sup 3} cylindrical ionization chamber is one of the methods of measuring the source strength at the hospitals because this chamber is readily available for beam calibration and dosimetry. While using the cylindrical chamber for this purpose, it is also required to determine the positioning error of the ionization chamber, with respect to the source, commonly called a distance error (c). The contribution of scatter radiation (M{sub s}) from floor, walls, ceiling, and other materials available in the treatment room also need to be determined accurately so that appropriate correction can be applied while calculating the source strength from the meter reading. Iterative methods of Newton-Raphson and least-squares were used in this work to determine scatter contribution in the experimentally observed meter reading (pC/s) of a cylindrical ionization chamber. Monte Carlo simulation was also used to cross verify the results of the least-squares method. The experimentally observed, least-squares calculated and Monte Carlo estimated values of meter readings from HDR {sup 192}Ir brachytherapy source were in good agreement. Considering procedural simplicity, the method of least-squares is recommended for use at the hospitals to estimate values of f (constant of proportionality), c, and M{sub s} required to determine the strength of HDR {sup 192}Ir brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

A Study of Experimental Measurements of Dosimetric Parameters in HDR IR-192 Source

Thermoluminescent dosimeters have been used to perform dosimetry measurements for the widely used Ir-192 microSelectron-HDR source with an improved polystyrene phantom. Radial dose functions and anisotropy functions, main parameters of 2D dose-rate formalism from the TG-43U1 protocol, have been obtained experimentally. Measurement results are compared with that of the Monte Carlo calculations reported, and no difference has been found between them.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fission Product Yields of {sup 233}U, {sup 235}U, {sup 238}U and {sup 239}Pu in Fields of Thermal Neutrons, Fission Neutrons and 14.7-MeV Neutrons

The yields of more than fifteen fission products have been carefully measured using radiochemical techniques, for {sup 235}U(n,f), {sup 239}Pu(n,f) in a thermal spectrum, for {sup 233}U(n,f), {sup 235}U(n,f), and {sup 239}Pu(n,f) reactions in a fission neutron spectrum, and for {sup 233}U(n,f), {sup 235}U(n,f), {sup 238}U(n,f), and {sup 239}Pu(n,f) for 14.7 MeV monoenergetic neutrons. Irradiations were performed at the EL3 reactor, at the Caliban and Prospero critical assemblies, and at the Lancelot electrostatic accelerator in CEA-Valduc. Fissions were counted in thin deposits using fission ionization chambers. The number of fission products of each species were measured by gamma spectrometry of co-located thick deposits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Actinide Neutron-Induced Fission Cross Section Measurements At LANSCE

Fission cross sections of a range of actinides have been measured at the Los Alamos Neutron Science Center (LANSCE) in support of nuclear energy applications in a wide energy range from sub thermal energies up to 200 MeV. Parallel-plate ionization chambers are used to measure fission cross sections ratios relative to the {sup 235}U standard while incident neutron energies are determined using the time-of-flight method. Recent measurements include the {sup 233,238}U, {sup 239-242}Pu and {sup 243}Am neutron-induced fission cross sections. Obtained data are presented in comparison with existing evaluations and previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗