A Novel Triple Inverter Design for CMOS Clocks and Oscillators.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Multiple purpose inverter design based on phase demodulated inverter circuit selected from state-of-the-art assessment of ten inverter circuits
This final report briefly reviews the main technical accomplishments of the INVERT award, summarizes existing or planned publications or transitions from the effort, and lastly reviews T2M strategies resulting from the program. Specifically, under the award, our team studied three main technical areas and performed one preliminary T2M study on the cost-benefit analysis of Inverse Design Methods and one major software release (the Maryland Inverse Design Benchmark Suite).
A class of simple resonantly commutated inverters are investigated for use in a high power (100 KW - 1000 KW) high frequency (10 KHz - 20 KHz) AC power distribution system. The Mapham inverter is found to provide a unique combination of large thyristor turn-off angle and good utilization factor, much better than an alternate 'current-fed' inverter. The effects of loading the Mapham inverter entirely with rectifier loads are investigated by simulation and with an experimental 3 KW 20 KHz inverter. This inverter is found to be well suited to a power system with heavy rectifier loading.
Not Available
The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.
Explore the source record for details and available documents.
Design of medium power dc to 115 volt, 60 Hertz ac inverter
In this digest a 50kW string PV inverter formed using all SiC semiconductor devices is presented. The inverter design includes additively manufactured power block, symmetrical Y-core inductors for ac side filter, and advanced inverter functionality for grid support. This inverter utilizes the conventional three-phase Voltage Source Inverter topology and optimizes the design for SiC based devices. This paper presents the full functional validation of the designed inverter along with quantification of the efficiency and power density. The performance of the inverter for high dc-bus voltage without multi-level topology to exploit SiC advantages is also presented in this digest. The full paper will include details of inverter design, optimization and further experimental validation.
As wind and solar displace synchronous generators whose inertia stabilizes the AC grid frequency on fast time scales, it has been proposed to use energy storage systems (ESSs) to mitigate frequency transient events. Such events require a rapid surge of power from the ESS, but they occur only rarely. The high temperature tolerance of SiC MOSFETs and diodes presents an opportunity for innovative ESS inverter designs. Herein we investigate a SiC ESS inverter design such that the SiC device ratings are obeyed during mild frequency events but are exceeded during rare, major events, for a potentially more economical inverter design. In support of this proposal we present: 1. An analysis of four years of grid frequency events in the U.S. Western Interconnection. 2. A switch-level ESS inverter simulation using SiC devices with detailed loss estimates. 3. Thermal analysis of the SiC power modules during a worst-case frequency event, showing that the modules can likely withstand the brief overcurrent. This analysis supports the conclusion that it may be advantageous for economical designs (acknowledging the increased risks) to undersize the SiC switches when designing inverters to perform active power control for grid frequency support. Such a strategy may result in SiC-based designs being more competitive with less costly silicon IGBT-based designs.
The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.
Design verification tests for logic and low level circuits, and preliminary single-phase breadboard of pulse width modulated static inverter
The software consists of control algorithms which control a single phase DC-AC inverter.
The development of an inverted core fast reactor aims to generate 60 MWth for about 30 Effective Full Power Years without refueling. The reactor design is a transportable reactor using UO{sub 2} fuel and lead-bismuth-eutectic cooled designed for marine applications and is intended to improve the reactor performances compared to the normal core design: better condition for passive cooling system capability by lower core pressure drop, taking advantage of potential power uprate from the lower maximum fuel temperature. Systematic design processes are presented in this work: fuel pin geometry selection, fuel assembly (FA) design, and core design. A relationship between pressure drops, coolant velocity, maximum fuel temperature, coolant channel diameter, and fuel volume fraction was introduced in a single graph used as a tool to select fuel pin geometry. Fuel fabrication capability also took place in consideration of FA design which led to 7 holes per FA, and two-dimensional temperature distribution studies were also carried out. Core design processes including radial zoning, axial zoning, and core optimization were conducted using Monte Carlo code MCS, which is UNIST CORE laboratory in-house code. The current core design uses 3 fuel enrichment levels and 3 FA types to control the local power distribution and power shift during its lifetime. (authors)
Distributed PV has important effects on overcurrent, overvoltage and islanding protection. These effects are more difficult to analyze because the faulted behavior of PV inverters is less well understood than for rotating machines. Full transient models of the inverter can be accurate, but that approach requires inverter design details and simulation software that doesn’t easily interoperate with utility protection system software. Further, anomalous model behaviors often emerge at different grid conditions, and these are difficult to fix in a proprietary model. Testing provides another approach to characterize inverters, validate models or answer questions of application. This earlier work found major impacts from the inverter design, firmware, operating point and balance-of-system components. Our objective is to characterize PV inverters from black-box testing, leading to standard test reports that could provide parameter sets for widely-implemented models in software tools. The tool vendors can then develop standard inverter models, as they did for rotating machines and exciters. Besides fully detailed transient models, inverters can be represented with steady-state current sources, dynamically controlled current sources or non-linear frequency-dependent black boxes. Type-test data could support the last three kinds of model. Short circuit and sag tests would encompass the basic fault types, reporting the maximum transient and rms currents over all power levels and points-on-wave within four time ranges : 1) 0 to 1 cycles, for close and latch consideration 2) 1 to 4 cycles, for equipment withstand 3) 4 to 30 cycles, for interrupt ratings 4) 30 cycles and beyond, for backup protection analysis Open circuit tests would vary output power and power factor, and report the maximum rms voltage from 1 to 10 cycles after the event. Without models, the type-test data could also provide upper limits on the expected overvoltages and overcurrents.
In a lithium-ion battery, electrons are released from the anode and go through an external electronic circuit to power devices, while ions simultaneously transfer through internal ionic media to meet with electrons at the cathode. Inspired by the fundamental electrochemistry of the lithium-ion battery, we envision a cell that can generate a current of ions instead of electrons, so that ions can be used for potential applications in biosystems. Based on this concept, we report an ‘electron battery’ configuration in which ions travel through an external circuit to interact with the intended biosystem whereas electrons are transported internally. As a proof-of-concept, we demonstrate the application of the electron battery by stimulating a monolayer of cultured cells, which fluoresces a calcium ion wave at a controlled ionic current. Electron batteries with the capability to generate a tunable ionic current could pave the way towards precise ion-system control in a broad range of biological applications
The Characterizing Emerging Technologies project focuses on developing, improving and validating characterization methods for PV modules, inverters and embedded power electronics. Characterization methods and associated analysis techniques are at the heart of technology assessments and accurate component and system modeling. Outputs of the project include measurement and analysis procedures that industry can use to accurately model performance of PV system components, in order to better distinguish and understand the performance differences between competing products (module and inverters) and new component designs and technologies (e.g., new PV cell designs, inverter topologies, etc.).